Measurement of cerebral blood flow by volume-selective 19F NMR spectroscopy.

Abstract:

:A stimulated echo sequence was used to obtain 19F NMR spectra from within a 4-ml voxel in a cat brain. The time dependence of the 19F NMR signal from an inert gas (CHF3) was used to calculate the blood flow in the voxel. The position of the voxel was selected using a 1H MR image.

journal_name

Magn Reson Med

authors

van Zijl PC,Ligeti L,Sinnwell T,Alger JR,Chesnick AS,Moonen CT,McLaughlin AC

doi

10.1002/mrm.1910160316

subject

Has Abstract

pub_date

1990-12-01 00:00:00

pages

489-95

issue

3

eissn

0740-3194

issn

1522-2594

journal_volume

16

pub_type

杂志文章
  • High-frequency subband compressed sensing MRI using quadruplet sampling.

    abstract:PURPOSE:To present and validate a new method that formalizes a direct link between k-space and wavelet domains to apply separate undersampling and reconstruction for high- and low-spatial-frequency k-space data. THEORY AND METHODS:High- and low-spatial-frequency regions are defined in k-space based on the separation o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24592

    authors: Sung K,Hargreaves BA

    更新日期:2013-11-01 00:00:00

  • High-fidelity, accelerated whole-brain submillimeter in vivo diffusion MRI using gSlider-spherical ridgelets (gSlider-SR).

    abstract:PURPOSE:To develop an accelerated, robust, and accurate diffusion MRI acquisition and reconstruction technique for submillimeter whole human brain in vivo scan on a clinical scanner. METHODS:We extend the ultra-high resolution diffusion MRI acquisition technique, gSlider, by allowing undersampling in q-space and radio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28232

    authors: Ramos-Llordén G,Ning L,Liao C,Mukhometzianov R,Michailovich O,Setsompop K,Rathi Y

    更新日期:2020-10-01 00:00:00

  • Fast lipid-suppressed MR temperature mapping with echo-shifted gradient-echo imaging and spectral-spatial excitation.

    abstract::The water proton resonance frequency (PRF) is temperature dependent and can thus be used for magnetic resonance (MR) thermometry. Since lipid proton resonance frequencies do not depend on temperature, fat suppression is essential for PRF-based temperature mapping. The efficacy of echo-shifted (TE > TR) gradient-echo i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199907)42:1<53::aid-mrm9>3

    authors: de Zwart JA,Vimeux FC,Delalande C,Canioni P,Moonen CT

    更新日期:1999-07-01 00:00:00

  • A semiautomatic method for rapid segmentation of velocity-encoded myocardial magnetic resonance imaging data.

    abstract:PURPOSE:To develop a semiautomatic method for rapid segmentation of myocardial tissue phase mapping (TPM) data. METHODS:Manual segmentation of the myocardium was performed at end-diastole and end-systole. The points in both user-defined masks were then automatically tracked over the entire cardiac cycle using temporal...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26486

    authors: Espe EKS,Skårdal K,Aronsen JM,Zhang L,Sjaastad I

    更新日期:2017-09-01 00:00:00

  • Analysis and correction of motion artifacts in diffusion weighted imaging.

    abstract::For diffusion-weighted magnetic resonance imaging and under circumstances where patient movement can be modeled as rigid body motion, it is shown both theoretically and experimentally that translations and rotations produce phase errors which are zero- and first-order, respectively, in position. While a navigator echo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320313

    authors: Anderson AW,Gore JC

    更新日期:1994-09-01 00:00:00

  • Kinetic modeling of hyperpolarized (13)C pyruvate metabolism in tumors using a measured arterial input function.

    abstract::Mathematical models are required to estimate kinetic parameters of [1-(13)C] pyruvate-lactate interconversion from magnetic resonance spectroscopy data. One- or two-way exchange models utilizing a hypothetical approximation to the true arterial input function (AIF), (e.g. an ideal 'box-car' function) have been used pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24546

    authors: Kazan SM,Reynolds S,Kennerley A,Wholey E,Bluff JE,Berwick J,Cunningham VJ,Paley MN,Tozer GM

    更新日期:2013-10-01 00:00:00

  • Quantification of punctate iron sources using magnetic resonance phase.

    abstract::Iron-mediated tissue damage is present in cerebrovascular and neurodegenerative diseases and neurotrauma. Brain microbleeds are often present in these maladies and are assuming increasing clinical importance. Because brain microbleeds present a source of pathologic iron to the brain, the noninvasive quantification of ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22185

    authors: McAuley G,Schrag M,Sipos P,Sun SW,Obenaus A,Neelavalli J,Haacke EM,Holshouser B,Madácsi R,Kirsch W

    更新日期:2010-01-01 00:00:00

  • In vivo evaluation of intracellular pH and high-energy phosphate metabolites during regional myocardial ischemia in cats using 31P nuclear magnetic resonance.

    abstract::Phosphorus-31 nuclear magnetic resonance spectroscopy (31P NMR) was used to assess the temporal changes of high-energy phosphate metabolites in the region of acute myocardial ischemia of open-chest cats. Eight anesthetized cats were studied following ligation of the left anterior descending coronary artery. Creatine p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030209

    authors: Stein PD,Goldstein S,Sabbah HN,Liu ZQ,Helpern JA,Ewing JR,Lakier JB,Chopp M,LaPenna WF,Welch KM

    更新日期:1986-04-01 00:00:00

  • View-ordering in radial fast spin-echo imaging.

    abstract::Radial MRI sequences are frequently used to obtain images with reduced sensitivity to motion. To decrease imaging time, multiple spin-echo acquisitions can be incorporated into radial sequences. In this case, different radial lines of Fourier data have different TE times and the resulting images can contain streaking ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20031

    authors: Theilmann RJ,Gmitro AF,Altbach MI,Trouard TP

    更新日期:2004-04-01 00:00:00

  • Comprehensive approach for correction of motion and distortion in diffusion-weighted MRI.

    abstract::Patient motion and image distortion induced by eddy currents cause artifacts in maps of diffusion parameters computed from diffusion-weighted (DW) images. A novel and comprehensive approach to correct for spatial misalignment of DW imaging (DWI) volumes acquired with different strengths and orientations of the diffusi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10677

    authors: Rohde GK,Barnett AS,Basser PJ,Marenco S,Pierpaoli C

    更新日期:2004-01-01 00:00:00

  • Localized imaging using stimulated echoes.

    abstract::Stimulated-echo localized spectroscopy was combined with phase- and frequency-encoding gradients to obtain "zoom" or magnified images of specific organs in situ. The technique requires neither surface coils nor an imaging coil arrangement that exclusively isolates the target organ. This technique can be readily applie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050412

    authors: Mills P,Chew W,Litt L,Moseley M

    更新日期:1987-10-01 00:00:00

  • A single acquisition localization technique.

    abstract::A method is demonstrated for detection of magnetization from a selected region within the sensitive volume of a surface coil in a single acquisition. Composite pulses are described which eliminate signals from regions where magnetization is rotated 270 and 450 degrees. There is a loss of 1.3% or less of signal from re...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030221

    authors: Karczmar GS,Matson GB,Weiner MW

    更新日期:1986-04-01 00:00:00

  • Differentiation between cortical atrophy and hydrocephalus using 1H MRS.

    abstract::Quantitative 1H MRS to determine cerebral metabolite patterns and MRI to determine CSF flow were applied to 12 patients with ventricular dilation-Group A, cortical atrophy (N = 5); or Group B, hydrocephalus (N = 7)- and in 9 normal controls. While mean brain water (Group A = 80% +/- 6; Group B = 86% +/- 5; normal = 85...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370317

    authors: Bluml S,McComb JG,Ross BD

    更新日期:1997-03-01 00:00:00

  • Magnetic resonance imaging of blood vessels at high fields: in vivo and in vitro measurements and image simulation.

    abstract::Unusually high image contrast in vivo magnetic resonance imaging of the brain becomes observable at high magnetic fields when the blood oxygenation level is lowered. The cause of the contrast has been attributed to a magnetic susceptibility effect induced by paramagnetic deoxyhemoglobin in red cells. When the cylinder...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910160103

    authors: Ogawa S,Lee TM

    更新日期:1990-10-01 00:00:00

  • MR microscopy of lung airways with hyperpolarized 3He.

    abstract::A technique using hyperpolarized (HP) 3He to image the small airways of the lung by using moderate flip angles and a short scanning period during early inspiration is demonstrated. Flip angles (alpha) ranging from 10-90 degrees were used in guinea pig experiments with scanning during the entire inspiration period. A s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390113

    authors: Chen XJ,Chawla MS,Hedlund LW,Möller HE,MacFall JR,Johnson GA

    更新日期:1998-01-01 00:00:00

  • Design of adiabatic selective pulses using optimal control theory.

    abstract::Optimal control theory has been applied in the past for the design of RF pulses for selective excitation. This was the outcome of having established the controllability of the MR spin system for the selective excitation problem. "Minimum distance" was the main formulation used for the solution. Because of their robust...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360311

    authors: Rosenfeld D,Zur Y

    更新日期:1996-09-01 00:00:00

  • Automatic segmentation of the brain and intracranial cerebrospinal fluid in T1-weighted volume MRI scans of the head, and its application to serial cerebral and intracranial volumetry.

    abstract::A new fully automatic algorithm for the segmentation of the brain and total intracranial cerebrospinal fluid (CSF) from T(1)-weighted volume MRI scans of the head, called Exbrain v.2, is described. The algorithm was developed in the context of serial intracranial volumetry. A brain mask obtained using a previous versi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10436

    authors: Lemieux L,Hammers A,Mackinnon T,Liu RS

    更新日期:2003-05-01 00:00:00

  • Correction for geometric distortion in echo planar images from B0 field variations.

    abstract::A method is described for the correction of geometric distortions occurring in echo planar images. The geometric distortions are caused in large part by static magnetic field inhomogeneities, leading to pixel shifts, particularly in the phase encode direction. By characterizing the field inhomogeneities from a field m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340111

    authors: Jezzard P,Balaban RS

    更新日期:1995-07-01 00:00:00

  • Simple measurement of scanner stability for functional NMR imaging of activation in the brain.

    abstract::Functional MR imaging (fMRI) of activation in the brain is one of the more demanding applications required of an NMR imaging instrument. Since the signal changes in activation imaging are quite small, any instrumental variations can easily compromise the fMRI contrast. The authors describe a simple method for measurin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360422

    authors: Weisskoff RM

    更新日期:1996-10-01 00:00:00

  • Validation of 13C NMR measurements of liver glycogen in vivo.

    abstract::The natural abundance 13C NMR intensity of the glycogen C1 resonance was measured in the surgically exposed liver of rabbits in vivo (n = 17) by integration from 98 to 104 ppm and compared double blindedly to the subsequent biochemical measurement. Coil loading was measured each time from a reference sphere at the coi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310602

    authors: Gruetter R,Magnusson I,Rothman DL,Avison MJ,Shulman RG,Shulman GI

    更新日期:1994-06-01 00:00:00

  • A novel bioreactor for combined magnetic resonance spectroscopy and optical imaging of metabolism in 3D cell cultures.

    abstract:PURPOSE:Fluorescence lifetime imaging microscopy (FLIM) of endogenous fluorescent metabolites permits the measurement of cellular metabolism in cell, tissue and animal models. In parallel, magnetic resonance spectroscopy (MRS) of dynamic nuclear (hyper)polarized (DNP) 13 C-pyruvate enables measurement of metabolism at ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27644

    authors: Cox BL,Erickson-Bhatt S,Szulczewski JM,Squirrell JM,Ludwig KD,Macdonald EB,Swader R,Ponik SM,Eliceiri KW,Fain SB

    更新日期:2019-05-01 00:00:00

  • A Bayesian approach for 4D flow imaging of aortic valve in a single breath-hold.

    abstract:PURPOSE:To develop and validate a data processing technique that allows phase-contrast MRI-based 4D flow imaging of the aortic valve in a single breath-hold. THEORY AND METHODS:To regularize the ill-posed inverse problem, we extend a recently proposed 2D phase-contrast MRI method to 4D flow imaging. Adopting an empiri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27386

    authors: Rich A,Potter LC,Jin N,Liu Y,Simonetti OP,Ahmad R

    更新日期:2019-02-01 00:00:00

  • Partial field-of-view spiral phase-contrast imaging using complex difference processing.

    abstract::Rapid flow imaging was achieved with a partial field of view (pFOV) spiral motion-encoded technique. The FOV and the acquisition time were reduced by a factor of 2 by undersampling k-space. The pFOV spiral k-space trajectory aliased signals from outside a circular ring whose radius was inversely proportional to the di...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20975

    authors: Nezafat R,Thompson RB,Derbyshire JA,McVeigh ER

    更新日期:2006-09-01 00:00:00

  • Comparison of diffusion- and T2-weighted MRI for the early detection of cerebral ischemia and reperfusion in rats.

    abstract::The sensitivity of diffusion-weighted MRI was compared to that of T2-weighted MRI following temporary middle cerebral artery occlusion (MCA-O) for 33 min followed by 4 h of reperfusion in rats. Diffusion-weighted spin-echo images using strong gradients (b value of 1413 s/mm2) demonstrated a significant increase in sig...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910180106

    authors: Mintorovitch J,Moseley ME,Chileuitt L,Shimizu H,Cohen Y,Weinstein PR

    更新日期:1991-03-01 00:00:00

  • Designing hyperbolic secant excitation pulses to reduce signal dropout in gradient-echo echo-planar imaging.

    abstract:PURPOSE:To design hyperbolic secant (HS) excitation pulses to reduce signal dropout in the orbitofrontal and inferior temporal regions in gradient-echo echo-planar imaging (GE-EPI) for functional MRI (fMRI) applications. METHODS:An algorithm based on Bloch simulations optimizes the HS pulse parameters needed to give t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25444

    authors: Wastling SJ,Barker GJ

    更新日期:2015-09-01 00:00:00

  • Radial single-shot STEAM MRI.

    abstract::Rapid MR imaging using the stimulated echo acquisition mode (STEAM) technique yields single-shot images without any sensitivity to resonance offset effects. However, the absence of susceptibility-induced signal voids or geometric distortions is at the expense of a somewhat lower signal-to-noise ratio than EPI. As a co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21401

    authors: Block KT,Frahm J

    更新日期:2008-04-01 00:00:00

  • Off-resonance-dependent slice profile effects in balanced steady-state free precession imaging.

    abstract::The purpose of this study was the simulation and measurement of balanced steady-state free precession (bSSFP) slice profiles for a detailed analysis of the influence of off-resonance effects on slice profile shape and bSSFP signal intensity. Due to the frequency response function of the bSSFP sequence, measurements th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21557

    authors: Staehle F,Leupold J,Hennig J,Markl M

    更新日期:2008-05-01 00:00:00

  • Fetal whole-heart 4D imaging using motion-corrected multi-planar real-time MRI.

    abstract:PURPOSE:To develop an MRI acquisition and reconstruction framework for volumetric cine visualization of the fetal heart and great vessels in the presence of maternal and fetal motion. METHODS:Four-dimensional (4D) depiction was achieved using a highly-accelerated multi-planar real-time balanced steady-state free prece...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27798

    authors: van Amerom JFP,Lloyd DFA,Deprez M,Price AN,Malik SJ,Pushparajah K,van Poppel MPM,Rutherford MA,Razavi R,Hajnal JV

    更新日期:2019-09-01 00:00:00

  • Direct comparison of in vivo versus postmortem second-order motion-compensated cardiac diffusion tensor imaging.

    abstract:PURPOSE:To directly compare in vivo versus postmortem second-order motion-compensated spin-echo diffusion tensor imaging of the porcine heart. METHODS:Second-order motion-compensated spin-echo cardiac diffusion tensor imaging was performed during systolic contraction in vivo and repeated upon cardiac arrest by bariumc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26871

    authors: Stoeck CT,von Deuster C,Fleischmann T,Lipiski M,Cesarovic N,Kozerke S

    更新日期:2018-04-01 00:00:00

  • Analysis by the Carr-Purcell-Meiboom-Gill sequence of the influence of P388 leukemia and of cis-diamminedichloroplatinum(II) nephrotoxicity on water compartmentalization in kidneys and spleens of mice.

    abstract::The multiexponential behavior of the decay curves obtained in vitro by a Carr-Purcell-Meiboom-Gill (CPMG) sequence from spleens and kidneys of mice is analyzed. The mice were inoculated with the acute lymphocytic P388 leukemic cells and treated with the anticancer drug cis-diamminedichloroplatinum(II), cis-Pt. Kidneys...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910070408

    authors: François A,Van Gerven L,Atassi G,Eisendrath H,Gielen M,Willem R

    更新日期:1988-08-01 00:00:00