Abstract:
PURPOSE:To measure the apparent diffusion coefficients (ADC) of five main metabolites in the human brain at 3T with PRESS and STEAM, avoiding measurement biases because of cross-terms. Cross-terms arise from interactions between slice-selection and spoiler gradients in the localized spectroscopy sequence and the diffusion gradients. METHODS:Diffusion-weighted spectra were acquired from the prefrontal cortex in five healthy subjects using STEAM (echo time [TE]/mixing time [TM]/pulse repetition time [TR] = 21.22/105/3000 ms, b-values = 0 and 3172 s/mm2 ) and PRESS (TE/TR = 54.2/3000 ms, b-values = 0 and 2204 s/mm2 ). Diffusion weighting was applied using bipolar gradients in three orthogonal directions. Post-processed spectra were analyzed with LCModel, and the trace/3 ADC values were calculated. RESULTS:Comparable trace/3 ADC values (0.14-0.18 µm2 /ms) were obtained for five main metabolites with both methods. These metabolites were quantified with Cramér-Rao lower bounds below 15%. CONCLUSION:The ADC values of the five main metabolites were successfully measured in the human brain at 3T with eliminated directional dependence. Both STEAM and PRESS can be used to probe the diffusivity of metabolites in normal brain and various pathologies on the clinical scanner with slightly higher precision achieved with STEAM for glutamate and myo-inositol. Magn Reson Med 79:2896-2901, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Deelchand DK,Auerbach EJ,Marjańska Mdoi
10.1002/mrm.26969subject
Has Abstractpub_date
2018-06-01 00:00:00pages
2896-2901issue
6eissn
0740-3194issn
1522-2594journal_volume
79pub_type
杂志文章abstract::Steady-state free precession (SSFP) methods have gained widespread recognition for their ability to provide fast scans at high signal-to-noise ratio. This paper demonstrates that such methods are also capable of reflecting functional information, particularly blood oxygenation state. It is well known that SSFP signals...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20393
更新日期:2005-03-01 00:00:00
abstract::Quantitative 1H MRS to determine cerebral metabolite patterns and MRI to determine CSF flow were applied to 12 patients with ventricular dilation-Group A, cortical atrophy (N = 5); or Group B, hydrocephalus (N = 7)- and in 9 normal controls. While mean brain water (Group A = 80% +/- 6; Group B = 86% +/- 5; normal = 85...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910370317
更新日期:1997-03-01 00:00:00
abstract::Hyperpolarized (HP) 129Xe can be dissolved in biologically compatible lipid emulsions while maintaining sufficient polarization for in vivo vascular imaging. For xenon in Intralipid 30%, in vitro spectroscopy at 2 T yielded a chemical shift of 197 +/- 1 ppm with reference to xenon gas, a spin-lattice relaxation time T...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199905)41:5<1058::aid-mrm2
更新日期:1999-05-01 00:00:00
abstract:PURPOSE:To design, construct, and evaluate quantitative MR phantoms that mimic MRI signals from the liver with simultaneous control of three parameters: proton-density fat fraction (PDFF), R 2 ∗ ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28452
更新日期:2021-02-01 00:00:00
abstract::To quantify metabolite and cation concentrations using NMR spectroscopy, the volumes of intracellular and extracellular spaces must be known. We describe a simple 31P NMR spectroscopic method that employs dimethyl methylphosphonate (DMMP) as a marker of total water space and phenylphosphonate (PPA) as a marker of extr...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910320206
更新日期:1994-08-01 00:00:00
abstract::The long readout times of single-shot acquisitions and the high field strengths desired for functional MRI (fMRI) using blood oxygenation level-dependent (BOLD) contrast make functional scans sensitive to magnetic field inhomogeneity. If it is not corrected during image reconstruction, field inhomogeneity can cause ge...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20079
更新日期:2004-06-01 00:00:00
abstract:PURPOSE:To achieve artifact-suppressed whole-brain pass-band-balanced steady-state free precession functional MRI from a single functional magnetic resonance imaging (fMRI) scan. METHODS:A complete and practical data acquisition sequence for alt-SSFP fMRI was developed. First, multishot flyback-echo-planar imaging (EP...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25797
更新日期:2016-05-01 00:00:00
abstract::A radiofrequency (RF) time-domain electron paramagnetic resonance (EPR) instrument operating at 300, 600, and 750 MHz was used to image tumor hypoxia with high spatial and temporal resolution. A high-speed signal-averaging Peripheral Component Interconnect (PCI) board with flexibility in the input signal level and the...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21194
更新日期:2007-04-01 00:00:00
abstract:PURPOSE:To develop velocity-selective (VS) MR angiography (MRA) protocols for arteriography and venography with whole-brain coverage. METHODS:Tissue suppression using velocity-selective saturation (VSS) pulse trains is sensitive to radiofrequency field (B1 +) inhomogeneity. To reduce its sensitivity, we replaced the l...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26864
更新日期:2018-04-01 00:00:00
abstract::19F NMR imaging of the perfluorocarbon emulsion Fluosol has been used to study regional variations in oxygen tension in rat liver and spleen. We have used the linear dependence of spin lattice relaxation rate (1/T1) on the partial oxygen pressure (pO2) of Fluosol to determine the oxygen tension in the reticuloendothel...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910290405
更新日期:1993-04-01 00:00:00
abstract::In this work we aimed to study the possibility of using supervised classifiers to quantify the main components of carotid atherosclerotic plaque in vivo on the basis of multisequence MRI data. MRI data consisting of five MR weightings were obtained from 25 symptomatic subjects. Histological micrographs of endarterecto...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20828
更新日期:2006-04-01 00:00:00
abstract:PURPOSE:To remove nuisance signals (e.g., water and lipid signals) for (1) H MRSI data collected from the brain with limited and/or sparse (k, t)-space coverage. METHODS:A union-of-subspace model is proposed for removing nuisance signals. The model exploits the partial separability of both the nuisance signals and the...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25635
更新日期:2016-02-01 00:00:00
abstract:PURPOSE:To investigate for the first time the feasibility of aortic four-dimensional (4D) flow at 7T, both contrast enhanced (CE) and non-CE. To quantify the signal-to-noise ratio (SNR) in aortic 4D flow as a function of field strength and CE with gadobenate dimeglumine (MultiHance). METHODS:Six healthy male volunteer...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25317
更新日期:2015-05-01 00:00:00
abstract:PURPOSE:To introduce a new outer volume suppression (OVS) technique that uses a single pulse and rotating gradients to accomplish frequency-swept excitation. This new technique, which is called gradient rotating outer volume excitation (GROOVE), produces a circular or elliptical suppression band rather than suppressing...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25101
更新日期:2015-01-01 00:00:00
abstract::Gadobutrol (Gd-Bt; Gadovist(R), Schering AG) is a 1-M Gadolinium (Gd)-based contrast agent. Its higher Gd concentration allows for reduction of injection volumes in first pass contrast-enhanced MR angiography (CE-MRA) and should increase bolus sharpness and image quality. However, ambivalent results were reported. In ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21345
更新日期:2008-01-01 00:00:00
abstract::Two single-shot volume imaging techniques are described. The first, single-echo echo-volume imaging, is essentially the echo-volume imaging (EVI) sequence suggested by Mansfield (J. Phys. C. 10, L55 (1977)). The second is a multi-spin-echo approach in which one plane of k-space is collected during each spin echo. In b...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910320518
更新日期:1994-11-01 00:00:00
abstract::In vivo effective relaxation rates in normal rat liver were evaluated for four dextran coated iron oxide agents: monocrystalline iron oxide nanocolloid (MION) with a mean particle diameter of 3.9 nm, a polycrystalline agent (PION) with a larger mean diameter of 12 nm, and these two agents labeled with the asialofetuin...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910370613
更新日期:1997-06-01 00:00:00
abstract::High-resolution magic-angle spinning has become a valuable tool to study biologic samples; however, there are only a few high-resolution magic-angle spinning methodologies that have been explored specifically to deal with small semisolid biomaterials such as tissues. Here, we report a novel high-resolution (1)H NMR sp...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22231
更新日期:2010-02-01 00:00:00
abstract::Assuming that the SSFP magnetization response maintains a steady state which is periodic in the presence of diffusion, we can solve for the diffusion effect in such sequences. Formulating a Fourier series decomposition solution to the Bloch-Torrey equation and imposing the steady-state condition, analytical expression...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910190209
更新日期:1991-06-01 00:00:00
abstract::Calculations and experiments that provide support for our previously stated theorem are presented: If two coils simultaneously receiving magnetic resonance signals from the same anatomic region exhibit zero mutual inductance, there can be no correlation of the noise. It is shown that correlation does not exist even in...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910200105
更新日期:1991-07-01 00:00:00
abstract:PURPOSE:Diabetic nephropathy (DN) is the leading cause of renal failure; however, current clinical tests are insufficient for assessing this disease. DN is associated with changes in renal metabolites, so we evaluated the utility of chemical exchange saturation transfer (CEST) imaging to detect changes characteristic o...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26045
更新日期:2016-11-01 00:00:00
abstract::Problems with in vivo proton spectroscopy include strong water and lipid signals, and the very complicated structures of the spectra. Multiple-quantum experiments can be designed to overcome these difficulties. Using a volume selective refocusing technique, one can demonstrate how multiple-quantum experiments can be p...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910060311
更新日期:1988-03-01 00:00:00
abstract::Magnetic resonance images of the lungs of a guinea pig have been produced using hyperpolarized helium as the source of the MR signal. The resulting images are not yet sufficiently optimized to reveal fine structural detail within the lung, but the spectacular signal from this normally signal-deficient organ system off...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910330219
更新日期:1995-02-01 00:00:00
abstract::The proton T(1) was measured at 132 μT in ex vivo prostate tissue specimens from radical prostatectomies of 35 patients with prostate cancer. Each patient provided two specimens. The NMR and MRI measurements involved proton repolarization, a field of typically 150 mT and detection of the 5.6-kHz signal with a supercon...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24177
更新日期:2012-04-01 00:00:00
abstract::Multiple-slice perfusion imaging by continuous arterial spin labeling (CASL) is made possible by amplitude modulation (AM) of the labeling RF pulse, but perfusion sensitivity is reduced relative to the single-slice technique. A computer model of the Bloch equations for velocity driven adiabatic fast passage was develo...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20604
更新日期:2005-09-01 00:00:00
abstract::Diffusion-weighted imaging suffers from motion artifacts and relatively low signal quality due to the long echo times required to permit the diffusion encoding. We investigated the inclusion of a noncylindrical fourth gradient coil, dedicated entirely to diffusion encoding, into the imaging system. Standard three-axis...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22971
更新日期:2011-12-01 00:00:00
abstract::This article introduces a novel method named "Parallel Imaging and Noquist in Tandem" (PINOT) for accelerated image acquisition of cine cardiac magnetic resonance imaging. This method combines two prior information formalisms, the SPACE-RIP implementation of parallel imaging and the Noquist method for reduced-data ima...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22696
更新日期:2011-04-01 00:00:00
abstract::Algorithms to reliably detect motion in navigator echoes are crucial to many MRI motion suppression techniques. The accuracy of these algorithms is affected by noise and deformation of navigator echo profile caused by physiologic motion. This study compared the performance of algorithms based on correlation and least ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910360120
更新日期:1996-07-01 00:00:00
abstract::The mechanics of the macrocirculation are examined as a basis for imaging blood flow within the system. The macrocirculation is defined as that part of the circulation in which inertial forces are not negligible compared to viscous forces and as such in human subjects comprises the heart and large blood vessels. Becau...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910140204
更新日期:1990-05-01 00:00:00
abstract::The commercial synthetic homopolypeptide polyaspartate (average MW = 30,000, approximately 220 monomers) in solution quantitatively binds up to 40 mol Gd3+ ions per mole of polyaspartate. The water proton relaxivity of the solutions is far higher than that of clinically used or commonly investigated gadolinium(III) co...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910310109
更新日期:1994-01-01 00:00:00