Magnetic resonance angiography with hyperpolarized 129Xe dissolved in a lipid emulsion.

Abstract:

:Hyperpolarized (HP) 129Xe can be dissolved in biologically compatible lipid emulsions while maintaining sufficient polarization for in vivo vascular imaging. For xenon in Intralipid 30%, in vitro spectroscopy at 2 T yielded a chemical shift of 197 +/- 1 ppm with reference to xenon gas, a spin-lattice relaxation time T1 = 25.3 +/- 2.1 sec, and a T2* time constant of 37 +/- 5 msec. Angiograms of the abdominal and pelvic veins in the rat obtained with 129Xe MRI after intravenous injection of HP 129Xe/Intralipid 30% into the tail demonstrated signal-to-noise ratios between 8 and 29. An analysis of the inflow effect on time-of-flight images of two segments of the inferior vena cava yielded additional information. The mean blood flow velocity was 34.7 +/- 1.0 mm/sec between the junction of the caudal veins and the kidneys and 13.3 +/- 0.8 mm/sec at the position of the diaphragm. The mean volume flow rates in these segments were 7.2 +/- 3.4 ml/min and 11.0 +/- 2.8 ml/min, respectively. Intravenous delivery of HP 129Xe dissolved in a carrier may lead to novel biomedical applications of laser-polarized gases.

journal_name

Magn Reson Med

authors

Möller HE,Chawla MS,Chen XJ,Driehuys B,Hedlund LW,Wheeler CT,Johnson GA

doi

10.1002/(sici)1522-2594(199905)41:5<1058::aid-mrm2

subject

Has Abstract

pub_date

1999-05-01 00:00:00

pages

1058-64

issue

5

eissn

0740-3194

issn

1522-2594

pii

10.1002/(SICI)1522-2594(199905)41:5<1058::AID-MRM2

journal_volume

41

pub_type

杂志文章
  • New "multicolor" polypeptide diamagnetic chemical exchange saturation transfer (DIACEST) contrast agents for MRI.

    abstract::An array of 33 prototype polypeptides was examined as putative contrast agents that can be distinguished from each other based on the chemical exchange saturation transfer (CEST) mechanism. These peptides were chosen based on predictions of the chemical exchange rates of exchangeable amide, amine, and hydroxyl protons...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21683

    authors: McMahon MT,Gilad AA,DeLiso MA,Berman SM,Bulte JW,van Zijl PC

    更新日期:2008-10-01 00:00:00

  • Steady state of echo-shifted sequences with radiofrequency phase cycling.

    abstract::Due to a delayed echo-formation, echo-shifted gradient echo sequences (ES-GRE) allow for an enhanced T(2)*-weighting at short repetition times. While they are in use with and without RF spoiling, analytical solutions are only known for the latter. The signal formation in the former could only be assessed in approximat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21010

    authors: Ganter C

    更新日期:2006-10-01 00:00:00

  • A highly sensitive lactate editing technique for surface coil spectroscopic imaging in vivo.

    abstract::A lactate editing sequence based on the use of spin-locking pulses with surface coils is described. The sequence retains more than 90% of the available lactate magnetization and suppresses at least 95% of the lipid signal in a single scan and ca. 99.5% after a simple two step cycle. The technique allows simultaneous o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290320

    authors: Bourgeois D,Kozlowski P

    更新日期:1993-03-01 00:00:00

  • Dynamic liver imaging with iron oxide agents: effects of size and biodistribution on contrast.

    abstract::In vivo effective relaxation rates in normal rat liver were evaluated for four dextran coated iron oxide agents: monocrystalline iron oxide nanocolloid (MION) with a mean particle diameter of 3.9 nm, a polycrystalline agent (PION) with a larger mean diameter of 12 nm, and these two agents labeled with the asialofetuin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370613

    authors: Mandeville JB,Moore J,Chesler DA,Garrido L,Weissleder R,Weisskoff RM

    更新日期:1997-06-01 00:00:00

  • Flow-suppressed hyperpolarized 13 C chemical shift imaging using velocity-optimized bipolar gradient in mouse liver tumors at 9.4 T.

    abstract:PURPOSE:To optimize and investigate the influence of bipolar gradients for flow suppression in metabolic quantification of hyperpolarized 13 C chemical shift imaging (CSI) of mouse liver at 9.4 T. METHODS:The trade-off between the amount of flow suppression using bipolar gradients and T2* effect from static spins was ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26578

    authors: Lee H,Lee J,Joe E,Yang S,Song JE,Choi YS,Wang E,Joo CG,Song HT,Kim DH

    更新日期:2017-11-01 00:00:00

  • Interactive continuously moving table (iCMT) large field-of-view real-time MRI.

    abstract::Continuously moving table (CMT) MRI is a new method that is capable of generating 3D, seamless, large field-of-view (FOV) images by acquiring readouts along the patient superior-inferior axis as the subject is translated through the scanner. For applications that require artifact-free images, such as arterial-phase co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20848

    authors: Sabati M,Lauzon ML,Mahallati H,Frayne R

    更新日期:2006-05-01 00:00:00

  • Quantitative and qualitative fat analysis in human leg muscle of neuromuscular diseases by 1H MR spectroscopy in vivo.

    abstract::1H MR spectra were recorded from human gastrocnemius muscle at 63.86 MHz using the body coil of the Signa scanner as transmitter and a 3-in. surface coil as receiver. The fat content of the muscle was quantified relative to that of water in a selected volume or slice. The fat/water ratio was 0.05-0.07 for normal muscl...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910100206

    authors: Bárány M,Venkatasubramanian PN,Mok E,Siegel IM,Abraham E,Wycliffe ND,Mafee MF

    更新日期:1989-05-01 00:00:00

  • Proton MRI as a noninvasive tool to assess elastase-induced lung damage in spontaneously breathing rats.

    abstract::Elastase-induced changes in lung morphology and function were detected in spontaneously breathing rats using conventional proton MRI at 4.7 T. A single dose of porcine pancreatic elastase (75 U/100 g body weight) or vehicle (saline) was administered intratracheally (i.t.) to male Brown Norway (BN) rats. MRI fluid sign...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21051

    authors: Quintana HK,Cannet C,Zurbruegg S,Blé FX,Fozard JR,Page CP,Beckmann N

    更新日期:2006-12-01 00:00:00

  • MR-derived cerebral blood volume maps: issues regarding histological validation and assessment of tumor angiogenesis.

    abstract::In an effort to develop MRI methods for the evaluation of tumor angiogenesis (new blood vessel formation), MRI-derived cerebral blood volume (CBV) information has been compared to histologic measures of microvessel density (MVD). Although MVD is a standard marker of angiogenesis, it is not a direct correlate of the vo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1252

    authors: Pathak AP,Schmainda KM,Ward BD,Linderman JR,Rebro KJ,Greene AS

    更新日期:2001-10-01 00:00:00

  • Pattern recognition analysis of 1H NMR spectra from perchloric acid extracts of human brain tumor biopsies.

    abstract::Pattern recognition techniques (factor analysis and neural networks) were used to investigate and classify human brain tumors based on the 1H NMR spectra of chemically extracted biopsies (n = 118). After removing information from lactate (because of variable ischemia times), unsupervised learning suggested that the sp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390604

    authors: Maxwell RJ,Martínez-Pérez I,Cerdán S,Cabañas ME,Arús C,Moreno A,Capdevila A,Ferrer E,Bartomeus F,Aparicio A,Conesa G,Roda JM,Carceller F,Pascual JM,Howells SL,Mazucco R,Griffiths JR

    更新日期:1998-06-01 00:00:00

  • A flexible fast spin echo triple-echo Dixon technique.

    abstract:PURPOSE:To develop a flexible fast spin echo (FSE) triple-echo Dixon (FTED) technique. METHODS:An FSE pulse sequence was modified by replacing each readout gradient with three fast-switching bipolar readout gradients with minimal interecho dead time. The corresponding three echoes were used to generate three raw image...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26186

    authors: Son JB,Hwang KP,Madewell JE,Bayram E,Hazle JD,Low RN,Ma J

    更新日期:2017-03-01 00:00:00

  • Polymer thick film technology for improved simultaneous dEEG/MRI recording: Safety and MRI data quality.

    abstract:PURPOSE:To develop a 256-channel dense-array electroencephalography (dEEG) sensor net (the Ink-Net) using high-resistance polymer thick film (PTF) technology to improve safety and data quality during simultaneous dEEG/MRI. METHODS:Heating safety was assessed with temperature measurements in an anthropomorphic head pha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26116

    authors: Poulsen C,Wakeman DG,Atefi SR,Luu P,Konyn A,Bonmassar G

    更新日期:2017-02-01 00:00:00

  • Improved sensitivity to overlapping multiplet signals in in vivo proton spectroscopy using a multiecho volume selective (CPRESS) experiment.

    abstract::A method for volume selective proton spectroscopy is presented based on a multiecho sequence with short refocusing interval tcp. It is demonstrated, that by appropriate choice of tcp on the order of 4-6 ms, signals from overlapping multiplets like the glutamine and glutamate (Glu/Gln) resonances in spectra of the huma...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370603

    authors: Hennig J,Thiel T,Speck O

    更新日期:1997-06-01 00:00:00

  • Echo-time reduction for submillimeter resolution imaging with a 3D phase encode time reduced acquisition method.

    abstract::To achieve optimal image quality and highest spatial resolution for inner ear imaging with a 3D gradient echo sequence, it is necessary to minimize susceptibility dephasing effects by using very short TE. Fractional RF pulses and echoes can yield short TE for moderate spatial resolution; however, for voxel size of les...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330112

    authors: Ying K,Schmalbrock P,Clymer B

    更新日期:1995-01-01 00:00:00

  • Continuously moving table MRI with golden angle radial sampling.

    abstract:PURPOSE:Continuously moving table (CMT) MRI is a high throughput technique that has multiple applications in whole-body imaging. In this work, CMT MRI based on golden angle (GA, 111.246° azimuthal step) radial sampling is developed at 3 Tesla (T), with the goal of increased flexibility in image reconstruction using arb...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25531

    authors: Sengupta S,Smith DS,Welch EB

    更新日期:2015-12-01 00:00:00

  • SSFP signal with finite RF pulses.

    abstract::The theoretical description of steady state free precession (SSFP) sequences is generally well accepted and unquestioned, although it is based on instantaneously acting radiofrequency (RF) pulses. In practice, however, all excitation processes are finite, thereby questioning the overall validity of the common SSFP sig...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22116

    authors: Bieri O,Scheffler K

    更新日期:2009-11-01 00:00:00

  • A pitfall associated with lactate detection using stimulated-echo proton spectroscopy.

    abstract::At TE values of 136 ms, it has recently been shown that the lactate methyl signal, when obtained with a stimulated-echo (STE) sequence, is modulated at the zero-quantum (ZQ) frequency when TM is varied. Here we describe an additional modulation of the ZQ lactate signal, due to spin-spin coupling, that results in a 10-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170223

    authors: Sotak CH,Alger JR

    更新日期:1991-02-01 00:00:00

  • Magnitude image CSPAMM reconstruction (MICSR).

    abstract::Image reconstruction of tagged cardiac MR images using complementary spatial modulation of magnetization (CSPAMM) requires the subtraction of two complex datasets to remove the untagged signal. Although the resultant images typically have sharper and more persistent tags than images formed without complementary taggin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10523

    authors: NessAiver M,Prince JL

    更新日期:2003-08-01 00:00:00

  • High-resolution slice-selective Fourier velocity encoding in congenital heart disease using spiral SENSE with velocity unwrap.

    abstract::Quantification of peak velocity is important in the assessment of stenotic flow jets in patients with congenital heart disease. Phase-contrast magnetic resonance underestimates peak velocities. Hence, clinically Doppler ultrasound is used as the reference standard for assessing stenoses. It is possible to accurately m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24293

    authors: Steeden JA,Jones A,Pandya B,Atkinson D,Taylor AM,Muthurangu V

    更新日期:2012-06-01 00:00:00

  • Three-dimensional magnetization-prepared time-of-flight MR angiography of the carotid and vertebral arteries.

    abstract::Three-dimensional magnetization-prepared (MP) MR angiography (MRA) was applied to the carotid and vertebral arteries by using ECG triggering, a slab selective RF inversion pulse, centric phase encoding and acquisition during diastole. Both theoretically and experimentally, the MP MRA sequence was shown to perform well...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370219

    authors: Wilman AH,Huston J 3rd,Riederer SJ

    更新日期:1997-02-01 00:00:00

  • RAPID--a new method for fast imaging using a single slice of Z-magnetization.

    abstract::A single slice of z-magnetization is used to generate high-speed images. The slice selection step is achieved using two sin-sinc pulses. This procedure eliminates the need for continual slice gradient reversal, a requirement for the FLASH technique. The RAPID imaging method has less inherent T1 and/or T2 dependence th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050213

    authors: Brooks WM,Brereton IM,Doddrell DM

    更新日期:1987-08-01 00:00:00

  • Oxygen extraction fraction mapping at 3 Tesla using an artificial neural network: A feasibility study.

    abstract:PURPOSE:The oxygen extraction fraction (OEF) is an important biomarker for tissue-viability. MRI enables noninvasive estimation of the OEF based on the blood-oxygenation-level-dependent (BOLD) effect. Quantitative OEF-mapping is commonly applied using least-squares regression (LSR) to an analytical tissue model. Howeve...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26749

    authors: Domsch S,Mürle B,Weingärtner S,Zapp J,Wenz F,Schad LR

    更新日期:2018-02-01 00:00:00

  • Temporal frequency analysis of dynamic MRI techniques.

    abstract::Dynamic imaging strategies often involve updating certain areas of k-space (i.e., the low spatial frequencies) more frequently than others. However, important dynamic signal changes may occur anywhere in k-space. In this study, a dynamic k-space sampling analysis method was developed to determine the energy error asso...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1074

    authors: Wu Y,Alexander AL

    更新日期:2001-04-01 00:00:00

  • The dependence of radiofrequency induced pacemaker lead tip heating on the electrical conductivity of the medium at the lead tip.

    abstract::Radiofrequency induced pacemaker lead tip heating is one of the main reasons magnetic resonance imaging (MRI) is contraindicated for patients with pacemakers. The objective of this work was to evaluate the dependence of pacemaker lead tip heating during MRI scanning on the electrical conductivity of the medium surroun...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23235

    authors: Langman DA,Goldberg IB,Judy J,Paul Finn J,Ennis DB

    更新日期:2012-08-01 00:00:00

  • x-f Choice: reconstruction of undersampled dynamic MRI by data-driven alias rejection applied to contrast-enhanced angiography.

    abstract::A technique for reconstructing dynamic undersampled MRI data, termed "x-f choice," was developed and applied to dynamic contrast-enhanced MR angiography (DCE-MRA). Regular undersampling in k-t space (a hybrid of k-space and time) creates aliasing in the conjugate x-f space that must be resolved. When regions in the ob...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21008

    authors: Malik SJ,Schmitz S,O'Regan D,Larkman DJ,Hajnal JV

    更新日期:2006-10-01 00:00:00

  • A double echo ultra short echo time (UTE) acquisition for respiratory motion-suppressed high resolution imaging of the lung.

    abstract:PURPOSE:Magnetic resonance imaging is a promising alternative to computed tomography for lung imaging. However, organ motion and poor signal-to-noise ratio, arising from short T2*, impair image quality. To alleviate these issues, a new retrospective gating method was implemented and tested with an ultra-short echo time...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26891

    authors: Delacoste J,Chaptinel J,Beigelman-Aubry C,Piccini D,Sauty A,Stuber M

    更新日期:2018-04-01 00:00:00

  • In vivo measurement of volumetric strain in the human brain induced by arterial pulsation and harmonic waves.

    abstract::Motion-sensitive phase contrast magnetic resonance imaging and magnetic resonance elastography are applied for the measurement of volumetric strain and tissue compressibility in human brain. Volumetric strain calculated by the divergence operator using a biphasic effective-medium model is related to dilatation and com...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24499

    authors: Hirsch S,Klatt D,Freimann F,Scheel M,Braun J,Sack I

    更新日期:2013-09-01 00:00:00

  • On the application of chemical shift-based multipoint water-fat separation methods in balanced SSFP imaging.

    abstract::Chemical shift-based multipoint water-fat separation methods have been applied in balanced steady-state free precession (bSSFP) sequences because of the high signal-to-noise-ratio (SNR) attainable. In this approach the echo formation is approximated to occur concurrently for both water and fat at an echo time (TE) equ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21303

    authors: Kim H,Pinus AB,Wang J,Murphy PS,Constable RT

    更新日期:2007-08-01 00:00:00

  • Flow-gated phase-contrast MRI using radial acquisitions.

    abstract::Phase-contrast (PC) MRI is a noninvasive method for imaging blood and tissue velocity. PC experiments are typically segmented into many cardiac cycles in order to obtain sufficient spatial and temporal resolution, and thus require a gating signal to properly combine the data from multiple cardiac cycles. Although the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20187

    authors: Thompson RB,McVeigh ER

    更新日期:2004-09-01 00:00:00

  • Design of universal parallel-transmit refocusing kT -point pulses and application to 3D T2 -weighted imaging at 7T.

    abstract:PURPOSE:T2 -weighted sequences are particularly sensitive to the radiofrequency (RF) field inhomogeneity problem at ultra-high-field because of the errors accumulated by the imperfections of the train of refocusing pulses. As parallel transmission (pTx) has proved particularly useful to counteract RF heterogeneities, u...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27001

    authors: Gras V,Mauconduit F,Vignaud A,Amadon A,Le Bihan D,Stöcker T,Boulant N

    更新日期:2018-07-01 00:00:00