Steady state of echo-shifted sequences with radiofrequency phase cycling.

Abstract:

:Due to a delayed echo-formation, echo-shifted gradient echo sequences (ES-GRE) allow for an enhanced T(2)*-weighting at short repetition times. While they are in use with and without RF spoiling, analytical solutions are only known for the latter. The signal formation in the former could only be assessed in approximative form, so far. In this article an exact analytical solution is presented for TR-periodic ES-GRE sequences with RF phase cycling. Besides providing a better numerical performance, it should be useful for systematic sequence development. The relation to recent approximative solutions is discussed.

journal_name

Magn Reson Med

authors

Ganter C

doi

10.1002/mrm.21010

subject

Has Abstract

pub_date

2006-10-01 00:00:00

pages

923-6

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

56

pub_type

杂志文章
  • Echo-planar imaging with prospective slice-by-slice motion correction using active markers.

    abstract::Head motion is a fundamental problem in functional magnetic resonance imaging and is often a limiting factor in its clinical implementation. This work presents a rigid-body motion correction strategy for echo-planar imaging sequences that uses micro radiofrequency coil "active markers" for real-time, slice-by-slice pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22780

    authors: Ooi MB,Krueger S,Muraskin J,Thomas WJ,Brown TR

    更新日期:2011-07-01 00:00:00

  • Whole-body continuously moving table fat-water MRI with dynamic B0 shimming at 3 Tesla.

    abstract:PURPOSE:The purpose of this work was to develop a rapid and robust whole-body fat-water MRI (FWMRI) method using a continuously moving table (CMT) with dynamic field corrections at 3 Tesla. METHODS:CMT FWMRI was developed at 3 Tesla with a multiecho golden angle (GA) radial trajectory and dynamic B0 field shimming. Wh...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25848

    authors: Sengupta S,Smith DS,Gifford A,Welch EB

    更新日期:2016-07-01 00:00:00

  • Wavelet transform-based Wiener filtering of event-related fMRI data.

    abstract::The advent of event-related functional magnetic resonance imaging (fMRI) has resulted in many exciting studies that have exploited its unique capability. However, the utility of event-related fMRI is still limited by several technical difficulties. One significant limitation in event-related fMRI is the low signal-to-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200011)44:5<746::aid-mrm13>3.0.c

    authors: LaConte SM,Ngan SC,Hu X

    更新日期:2000-11-01 00:00:00

  • Composite MRA: statistical approach to generate an MR angiogram from multiple contrasts.

    abstract:PURPOSE:To develop a method to use information from multiple MRI contrasts to produce a composite angiogram with reduced sequence-specific artifacts and improved vessel depiction. METHODS:Bayesian posterior vessel probability was determined as a function of black blood (BB), contrast enhanced angiography (CE-MRA), and...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27966

    authors: Kim D,Edjlali M,Turski P,Johnson KM

    更新日期:2020-03-01 00:00:00

  • Wavelet packet denoising of magnetic resonance images: importance of Rician noise at low SNR.

    abstract::Wavelet packet analysis is a mathematical transformation that can be used to post-process images, for example, to remove image noise ("denoising"). At a very low signal-to-noise ratio (SNR <5), standard magnitude magnetic resonance images have skewed Rician noise statistics that degrade denoising performance. Since th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199903)41:3<631::aid-mrm29

    authors: Wood JC,Johnson KM

    更新日期:1999-03-01 00:00:00

  • Triple diffusion encoding MRI predicts intra-axonal and extra-axonal diffusion tensors in white matter.

    abstract:PURPOSE:To demonstrate how triple diffusion encoding (TDE) MRI can be applied to separately estimate the intra-axonal and extra-axonal diffusion tensors in white matter (WM). METHODS:Using a TDE pulse sequence with an axially symmetric b-matrix, diffusion MRI data were acquired at 3T for 3 healthy adults with an axial...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28084

    authors: Ramanna S,Moss HG,McKinnon ET,Yacoub E,Helpern JA,Jensen JH

    更新日期:2020-06-01 00:00:00

  • Robust 4D flow denoising using divergence-free wavelet transform.

    abstract:PURPOSE:To investigate four-dimensional flow denoising using the divergence-free wavelet (DFW) transform and compare its performance with existing techniques. THEORY AND METHODS:DFW is a vector-wavelet that provides a sparse representation of flow in a generally divergence-free field and can be used to enforce "soft" ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25176

    authors: Ong F,Uecker M,Tariq U,Hsiao A,Alley MT,Vasanawala SS,Lustig M

    更新日期:2015-02-01 00:00:00

  • In vivo study of microbubbles as an MR susceptibility contrast agent.

    abstract::The potential application of gas microbubbles as a unique intravascular susceptibility contrast agent for MRI has not been fully explored. In this study, the MR susceptibility effect of an ultrasound microbubble contrast agent, Optison, was studied with rat liver imaging at 7 T. Optison suspension in two different dos...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20181

    authors: Wong KK,Huang I,Kim YR,Tang H,Yang ES,Kwong KK,Wu EX

    更新日期:2004-09-01 00:00:00

  • Evidence for enhanced functional activity of cervical cord in relapsing multiple sclerosis.

    abstract::Functional MRI (fMRI) was used to assess proprioceptive-associated cervical cord activity in 24 relapsing multiple sclerosis (MS) patients and 10 controls. Cord and brain conventional and diffusion tensor (DT) MRI were also acquired. fMRI was performed using a block design during a proprioceptive stimulation consistin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21595

    authors: Agosta F,Valsasina P,Rocca MA,Caputo D,Sala S,Judica E,Stroman PW,Filippi M

    更新日期:2008-05-01 00:00:00

  • T2 of endotoxin lung injury with and without methylprednisolone treatment.

    abstract::NMR relaxation times (T1 and T2) and the water content (WC) of in vitro rat lungs were measured during the course of endotoxin lung injury in rats. Measurements of normal lungs, untreated endotoxin-injured lungs, and endotoxin-injured lungs treated with methylprednisolone (MPSL) were compared. The untreated endotoxin ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910150204

    authors: Shioya S,Haida M,Tsuji C,Ono Y,Miyairi A,Fukuzaki M,Ohta Y,Yamabayashi H

    更新日期:1990-08-01 00:00:00

  • Sensitivity enhancement and reduction of Gibbs artifact in T2-weighted imaging using variable tip angle excitation.

    abstract::Introduction of a Gaussian weighting function into the phase encoding of the spin-echo imaging method via variable tip angle excitation, with concomitant optimization of the recycle delay, is shown to increase the sensitivity of T2-weighted imaging by up to 40%. In addition, the Gibbs artifact associated with sharp bo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910210216

    authors: Webb AG,Clarkson RB

    更新日期:1991-10-01 00:00:00

  • Safety and technique of ferumoxytol administration for MRI.

    abstract::Ferumoxytol is an ultrasmall superparamagnetic iron oxide agent marketed for the treatment of anemia. There has been increasing interest in its properties as an MRI contrast agent as well as greater awareness of its adverse event profile. This mini-review summarizes the current state of knowledge of the risks of ferum...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.26151

    authors: Vasanawala SS,Nguyen KL,Hope MD,Bridges MD,Hope TA,Reeder SB,Bashir MR

    更新日期:2016-05-01 00:00:00

  • Statistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise.

    abstract::This work helps elucidate how background noise introduces statistical artifacts in the distribution of the sorted eigenvalues and eigenvectors in diffusion tensor MRI (DT-MRI) data. Although it was known that sorting eigenvalues (principal diffusivities) by magnitude introduces a bias in their sample mean within a hom...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200007)44:1<41::aid-mrm8>3.0.co;

    authors: Basser PJ,Pajevic S

    更新日期:2000-07-01 00:00:00

  • Iterative reweighted linear least squares for accurate, fast, and robust estimation of diffusion magnetic resonance parameters.

    abstract:PURPOSE:Diffusion-weighted magnetic resonance imaging suffers from physiological noise, such as artifacts caused by motion or system instabilities. Therefore, there is a need for robust diffusion parameter estimation techniques. In the past, several techniques have been proposed, including RESTORE and iRESTORE (Chang e...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25351

    authors: Collier Q,Veraart J,Jeurissen B,den Dekker AJ,Sijbers J

    更新日期:2015-06-01 00:00:00

  • Improved myo-inositol detection through Carr-Purcell PRESS: a tool for more sensitive mild cognitive impairment diagnosis.

    abstract::A 3-T study is presented, comparing the ability of two (1) H spectroscopy pulse sequences, Carr-Purcell point resolved spectroscopy (CPRESS; TE = 45 msec), and conventional PRESS (TE = 35 msec), to separate between groups of 20 normal control (NC) and 20 mild cognitive impairment (MCI) subjects. Both sequences showed ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22749

    authors: Hancu I,Gillen R,Cowan J,Zimmerman EA

    更新日期:2011-06-01 00:00:00

  • Identification of signal bias in the variable flip angle method by linear display of the algebraic Ernst equation.

    abstract::A novel linear parameterization for the variable flip angle method for longitudinal relaxation time T(1) quantification from spoiled steady state MRI is derived from the half angle tangent transform, τ, of the flip angle. Plotting the signal S at coordinates x=Sτ and y=S/τ, respectively, establishes a line that render...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22849

    authors: Helms G,Dathe H,Weiskopf N,Dechent P

    更新日期:2011-09-01 00:00:00

  • Dextran-magnetite: a contrast agent for sodium-23 MRI.

    abstract::Dextran-magnetite, a superparamagnetic compound, is a powerful relaxation reagent for sodium. Administered intravenously, it is confined mainly to the vasculature and eliminates the signal from plasma sodium, a significant component of the tissue sodium signal. Applications of dextran-magnetite for in vivo sodium imag...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910080406

    authors: Summers RM,Joseph PM,Renshaw PF,Kundel HL

    更新日期:1988-12-01 00:00:00

  • Iterative projection onto convex sets for quantitative susceptibility mapping.

    abstract:PURPOSE:Quantitative susceptibility map (QSM) reconstruction is ill posed due to the zero values on the "magic angle cone" that make the maps prone to streaking artifacts. We propose projection onto convex sets (POCS) in the method of steepest descent (SD) for QSM reconstruction. METHODS:Two convex projections, an obj...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25155

    authors: Deng W,Boada F,Poser BA,Schirda C,Stenger VA

    更新日期:2015-02-01 00:00:00

  • Development and optimization of hardware for delta relaxation enhanced MRI.

    abstract:PURPOSE:Delta relaxation enhanced magnetic resonance (dreMR) imaging requires an auxiliary B0 electromagnet capable of shifting the main magnetic field within a clinical 1.5 Tesla (T) MR system. In this work, the main causes of interaction between an actively shielded, insertable resistive B0 electromagnet and a 1.5T s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25014

    authors: Harris CT,Handler WB,Araya Y,Martínez-Santiesteban F,Alford JK,Dalrymple B,Van Sas F,Chronik BA,Scholl TJ

    更新日期:2014-10-01 00:00:00

  • Experimental encephalomyelitis modulates inositol and taurine in the spinal cord of Biozzi mice.

    abstract::In this high resolution magnetic resonance spectroscopic study of experimental allergic encephalomyelitis (EAE) and Semliki Forest virus (SFV) infection of the Biozzi AB/H mouse, marked increases in the initially low levels of N-trimethyl compounds in the spinal cord were observed during probable demyelinating episode...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320603

    authors: Preece NE,Amor S,Baker D,Gadian DG,O'Neill JK,Urenjak J

    更新日期:1994-12-01 00:00:00

  • Parallel MRI reconstruction using variance partitioning regularization.

    abstract::Multiple receivers can be utilized to enhance the spatiotemporal resolution of MRI by employing the parallel imaging technique. Previously, we have reported the L-curve Tikhonov regularization technique to mitigate noise amplification resulting from the geometrical correlations between channels in a coil array. Nevert...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21356

    authors: Lin FH,Wang FN,Ahlfors SP,Hämäläinen MS,Belliveau JW

    更新日期:2007-10-01 00:00:00

  • T1 measurements in the human myocardium: the effects of magnetization transfer on the SASHA and MOLLI sequences.

    abstract:PURPOSE:Quantitative mapping of the native T1 of the heart using the modified look-locker inversion recovery (MOLLI) technique provides high quality diagnostic information without requiring contrast agents. Previous work has considered the effects of T2 relaxation on MOLLI T1 measurements, finding that the T1 measured ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24867

    authors: Robson MD,Piechnik SK,Tunnicliffe EM,Neubauer S

    更新日期:2013-09-01 00:00:00

  • Spiral trajectory design: a flexible numerical algorithm and base analytical equations.

    abstract:PURPOSE:Spiral-based trajectories for magnetic resonance imaging can be advantageous, but are often cumbersome to design or create. This work presents a flexible numerical algorithm for designing trajectories based on explicit definition of radial undersampling, and also gives several analytical expressions for charact...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24675

    authors: Pipe JG,Zwart NR

    更新日期:2014-01-01 00:00:00

  • Integrated volume-selective/spectral editing 1H NMR and postdetection signal processing for the sensitive determination of lactate.

    abstract::A new volume selection/spectral editing pulse sequence (VOSING) is presented. The features specific to the technique are that the volume selection and the editing intervals coincide and that no decoupling is necessary. The pulse sequence can be applied under both homo- and heteronuclear conditions. Phantom experiments...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910080108

    authors: Knüttel A,Rommel E,Clausen M,Kimmich R

    更新日期:1988-09-01 00:00:00

  • Respiration based steering for high intensity focused ultrasound liver ablation.

    abstract:PURPOSE:Respiratory motion makes hepatic ablation using high intensity focused ultrasound (HIFO) challenging. Previous HIFU liver treatment had required apnea induced during general anesthesia. We describe and test a system that allows treatment of the liver in the presence of breathing motion. METHODS:Mapping a signa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24695

    authors: Holbrook AB,Ghanouni P,Santos JM,Dumoulin C,Medan Y,Pauly KB

    更新日期:2014-02-01 00:00:00

  • Diffusion/perfusion MR imaging of acute cerebral ischemia.

    abstract::In vivo echo-planar MR imaging was used to measure apparent diffusion coefficients (ADC) of cerebral tissues in a comprehensive noninvasive evaluation of early ischemic brain damage induced by occlusion of the middle cerebral artery (MCA) in a cat model of acute regional stroke. Within 10 min after arterial occlusion,...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190220

    authors: Kucharczyk J,Mintorovitch J,Asgari HS,Moseley M

    更新日期:1991-06-01 00:00:00

  • A computer simulation of nuclear magnetic resonance imaging.

    abstract::A modular, user-friendly computer simulation of NMR imaging was created for the DEC VAX computer. This simulation is novel in that complex imaging phenomena, such as chemical shifts and flow, may be easily studied. Other features include spin warp and backprojection imaging, movie generation, and simulation of image c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030302

    authors: Summers RM,Axel L,Israel S

    更新日期:1986-06-01 00:00:00

  • Accelerating magnetic resonance fingerprinting (MRF) using t-blipped simultaneous multislice (SMS) acquisition.

    abstract:PURPOSE:We incorporate simultaneous multislice (SMS) acquisition into MR fingerprinting (MRF) to accelerate the MRF acquisition. METHODS:The t-Blipped SMS-MRF method is achieved by adding a Gz blip before each data acquisition window and balancing it with a Gz blip of opposing polarity at the end of each TR. Thus the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25799

    authors: Ye H,Ma D,Jiang Y,Cauley SF,Du Y,Wald LL,Griswold MA,Setsompop K

    更新日期:2016-05-01 00:00:00

  • Selective excitation of two-dimensional arbitrarily shaped voxels with parallel excitation in spectroscopy.

    abstract::Parallel excitation is being studied intensively for applications in MR imaging and in particular for selecting arbitrary shapes as regions of interest. In this work, parallel excitation was applied to arbitrarily shaped voxel selection in spectroscopy and investigated for different excitation k-space trajectories (ra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23018

    authors: Snyder J,Haas M,Hennig J,Zaitsev M

    更新日期:2012-02-01 00:00:00

  • Parallel excitation for B-field insensitive fat-saturation preparation.

    abstract::Multichannel transmission has the potential to improve many aspects of MRI through a new paradigm in excitation. In this study, multichannel transmission is used to address the effects that variations in B(0) homogeneity have on fat-saturation preparation through the use of the frequency, phase, and amplitude degrees ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23238

    authors: Heilman JA,Derakhshan JD,Riffe MJ,Gudino N,Tkach J,Flask CA,Duerk JL,Griswold MA

    更新日期:2012-08-01 00:00:00