T1 measurements in the human myocardium: the effects of magnetization transfer on the SASHA and MOLLI sequences.

Abstract:

PURPOSE:Quantitative mapping of the native T1 of the heart using the modified look-locker inversion recovery (MOLLI) technique provides high quality diagnostic information without requiring contrast agents. Previous work has considered the effects of T2 relaxation on MOLLI T1 measurements, finding that the T1 measured by MOLLI is biased, and that Saturation-recovery single-Shot Acquisition generates a more precise T1. However, despite detailed experiments and simulation the exact relaxation times observed in vivo remain unexplained, but might be due to magnetization transfer (MT). METHODS:We used an MT simulation based on the Bloch-McConnell equations to evaluate the most common MOLLI and saturation-recovery single-shot acquisition sequence variants. RESULTS:For myocardial tissue we find that the T1 measured by saturation-recovery single-shot acquisition is insensitive to MT and T2, whereas MT reduces the T1 measured by MOLLI (>10%) in addition to the effects due to T2 relaxation. CONCLUSIONS:The consequences of this T1 underestimation by MOLLI are relevant. Increases in the actual T1 and T2 and decreases in MT will all result in an increase in T1 measured by MOLLI. Myocardial infarction demonstrates increased native T1 and T2 and decreased MT, indicating that these biases enhance the sensitivity of MOLLI to detect this and possibly other cardiovascular disease states.

journal_name

Magn Reson Med

authors

Robson MD,Piechnik SK,Tunnicliffe EM,Neubauer S

doi

10.1002/mrm.24867

subject

Has Abstract

pub_date

2013-09-01 00:00:00

pages

664-70

issue

3

eissn

0740-3194

issn

1522-2594

journal_volume

70

pub_type

杂志文章
  • Strategy for the spectral filtering of myo-inositol and other strongly coupled spins.

    abstract::A multiple quantum filter strategy is presented for spectrally discriminating metabolites with strongly coupled spins from those whose spins are either uncoupled or weakly coupled. The strategy also includes a means for selectively suppressing the background multiplets of metabolites that also have strongly coupled sp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10697

    authors: Kim H,Wild JM,Allen PS

    更新日期:2004-02-01 00:00:00

  • Triple diffusion encoding MRI predicts intra-axonal and extra-axonal diffusion tensors in white matter.

    abstract:PURPOSE:To demonstrate how triple diffusion encoding (TDE) MRI can be applied to separately estimate the intra-axonal and extra-axonal diffusion tensors in white matter (WM). METHODS:Using a TDE pulse sequence with an axially symmetric b-matrix, diffusion MRI data were acquired at 3T for 3 healthy adults with an axial...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28084

    authors: Ramanna S,Moss HG,McKinnon ET,Yacoub E,Helpern JA,Jensen JH

    更新日期:2020-06-01 00:00:00

  • Sliding time of flight: sliding time of flight MR angiography using a dynamic image reconstruction method.

    abstract:PURPOSE:To obtain three-dimensional (3D) MR angiography having high contrast between vessel and stationary background tissue, a novel technique called sliding time of flight (TOF) is proposed. METHODS:The proposed method relies on the property that flow-related enhancement (FRE) is maximized at the blood-entering slic...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25215

    authors: Choi J,Seo H,Lim Y,Han Y,Park H

    更新日期:2015-03-01 00:00:00

  • NMR investigation of hydroxyethyl starch-induced aggregation of human erythrocytes.

    abstract::Aggregation of human erythrocytes at physiological hematocrit by hydroxyethyl starch (HES) was investigated with a 1H nuclear magnetic resonance method which measures the erythrocyte mean water exchange time, tau a. A relationship that takes into account the effect of the aggregate as the water-exchanging unit was use...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050108

    authors: Caines GH,Goldstein JH

    更新日期:1987-07-01 00:00:00

  • Dynamic changes in water ADC, energy metabolism, extracellular space volume, and tortuosity in neonatal rat brain during global ischemia.

    abstract::To obtain a better understanding of the mechanisms underlying early changes in the brain water apparent diffusion coefficient (ADC) observed in cerebral ischemia, dynamic changes in the ADC of water and in the energy status were measured at postnatal day 8 or 9 in neonatal rat brains after cardiac arrest using 1H MRS/...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360110

    authors: van der Toorn A,Syková E,Dijkhuizen RM,Vorísek I,Vargová L,Skobisová E,van Lookeren Campagne M,Reese T,Nicolay K

    更新日期:1996-07-01 00:00:00

  • Aortic wall shear stress in Marfan syndrome.

    abstract::The aim of this study was to quantify changes in thoracic aortic wall shear stress (WSS) in asymptomatic patients with Marfan syndrome (MFS) compared with healthy controls. WSS in the thoracic aorta was quantified based on time-resolved 3D phase contrast MRI with three-directional velocity encoding (4D flow MRI, tempo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24562

    authors: Geiger J,Arnold R,Herzer L,Hirtler D,Stankovic Z,Russe M,Langer M,Markl M

    更新日期:2013-10-01 00:00:00

  • Dynamic 13C NMR analysis of pyruvate and lactate oxidation in the in vivo canine myocardium: evidence of reduced utilization with increased work.

    abstract::In this work, substrate selection was monitored in the left ventricle of the canine myocardium by following pyruvate and lactate oxidation under in vivo conditions at basal and elevated workloads. These studies were conducted in the open chest model using dynamic 13C NMR techniques in the presence and absence of dichl...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380608

    authors: Rath DP,Zhu H,Tong X,Jiang Z,Hamlin RL,Robitaille PM

    更新日期:1997-12-01 00:00:00

  • Multislice and multicoil phase-sensitive inversion-recovery imaging.

    abstract::Phase-sensitive inversion-recovery (PSIR) imaging may provide enhanced T(1) contrast. However, clinical implementation of PSIR imaging is hindered because image reconstruction with this method often lacks robustness and requires manual intervention, particularly for data acquired in multiple slices and with phased-arr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20414

    authors: Ma J

    更新日期:2005-04-01 00:00:00

  • Sodium NMR imaging of lung water in rats.

    abstract::Coronal proton and sodium images of control rats and rats with either increased permeability edema produced by intravenous alloxan (300 mg/kg) or increased pressure edema produced by saline infusion (2 ml/min) were obtained. Axial chest CT images were used to monitor the development of pulmonary edema. Immediately aft...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060403

    authors: Kundel HL,Shetty A,Joseph PM,Summers RM,Kassab EA,Moore B

    更新日期:1988-04-01 00:00:00

  • Iterative projection onto convex sets for quantitative susceptibility mapping.

    abstract:PURPOSE:Quantitative susceptibility map (QSM) reconstruction is ill posed due to the zero values on the "magic angle cone" that make the maps prone to streaking artifacts. We propose projection onto convex sets (POCS) in the method of steepest descent (SD) for QSM reconstruction. METHODS:Two convex projections, an obj...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25155

    authors: Deng W,Boada F,Poser BA,Schirda C,Stenger VA

    更新日期:2015-02-01 00:00:00

  • A semiautomatic method for rapid segmentation of velocity-encoded myocardial magnetic resonance imaging data.

    abstract:PURPOSE:To develop a semiautomatic method for rapid segmentation of myocardial tissue phase mapping (TPM) data. METHODS:Manual segmentation of the myocardium was performed at end-diastole and end-systole. The points in both user-defined masks were then automatically tracked over the entire cardiac cycle using temporal...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26486

    authors: Espe EKS,Skårdal K,Aronsen JM,Zhang L,Sjaastad I

    更新日期:2017-09-01 00:00:00

  • Investigation of human cervical and upper thoracic spinal cord motion: implications for imaging spinal cord structure and function.

    abstract::Spinal cord (SC) motion is thought to be the dominant source of error in current diffusion and spinal functional MRI (fMRI) methods. However, until now, such motion has not been well characterized in three dimensions. While previous studies have predominantly examined motion in the superior/inferior (S/I) direction, t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21260

    authors: Figley CR,Stroman PW

    更新日期:2007-07-01 00:00:00

  • Design of adiabatic selective pulses using optimal control theory.

    abstract::Optimal control theory has been applied in the past for the design of RF pulses for selective excitation. This was the outcome of having established the controllability of the MR spin system for the selective excitation problem. "Minimum distance" was the main formulation used for the solution. Because of their robust...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360311

    authors: Rosenfeld D,Zur Y

    更新日期:1996-09-01 00:00:00

  • Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo.

    abstract::Brain water proton (1H2O) longitudinal relaxation time constants (T1) were obtained from three healthy individuals at magnetic field strengths (B0) of 0.2 Tesla (T), 1.0T, 1.5T, 4.0T, and 7.0T. A 5-mm midventricular axial slice was sampled using a modified Look-Locker technique with 1.5 mm in-plane resolution, and 32 ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21122

    authors: Rooney WD,Johnson G,Li X,Cohen ER,Kim SG,Ugurbil K,Springer CS Jr

    更新日期:2007-02-01 00:00:00

  • Fast maximum intensity projection algorithm using shear warp factorization and reduced resampling.

    abstract::Maximal intensity projection (MIP) is routinely used to view MRA and other volumetric angiographic data. The straightforward implementation of MIP is ray casting that traces a volumetric data set in a computationally expensive manner. This article reports a fast MIP algorithm using shear warp factorization and reduced...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10114

    authors: Fang L,Wang Y,Qiu B,Qian Y

    更新日期:2002-04-01 00:00:00

  • Fast mapping of myocardial blood flow with MR first-pass perfusion imaging.

    abstract::Accurate and fast quantification of myocardial blood flow (MBF) with MR first-pass perfusion imaging techniques on a pixel-by-pixel basis remains difficult due to relatively long calculation times and noise-sensitive algorithms. In this study, Zierler's central volume principle was used to develop an algorithm for the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21559

    authors: Goldstein TA,Jerosch-Herold M,Misselwitz B,Zhang H,Gropler RJ,Zheng J

    更新日期:2008-06-01 00:00:00

  • Sampling errors in projection reconstruction MRI.

    abstract::Certain kinds of artifacts have been reported when projection reconstruction (PR) techniques are used in magnetic resonance imaging (MRI). These will occur if the spacing between samples in k-space is too large. It has been suggested that PR requires finer k-space sampling than does two-dimensional Fourier reconstruct...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400317

    authors: Joseph PM

    更新日期:1998-09-01 00:00:00

  • Improved MRI R2 * relaxometry of iron-loaded liver with noise correction.

    abstract::Accurate and reproducible MRI R2 * relaxometry for tissue iron quantification is important in managing transfusion-dependent patients. MRI data are often acquired using array coils and reconstructed by the root-sum-square algorithm, and as such, measured signals follow the noncentral chi distribution. In this study, t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24607

    authors: Feng Y,He T,Gatehouse PD,Li X,Harith Alam M,Pennell DJ,Chen W,Firmin DN

    更新日期:2013-12-01 00:00:00

  • A strictly noninvasive MR setup dedicated to longitudinal studies of mechanical performance, bioenergetics, anatomy, and muscle recruitment in contracting mouse skeletal muscle.

    abstract::MR techniques have proven their ability to investigate skeletal muscle function in situ. Their benefit in terms of noninvasiveness is, however, lost in animal research, given that muscle stimulation and force output measurements are usually achieved using invasive surgical procedures, thereby excluding repeated invest...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22386

    authors: Giannesini B,Vilmen C,Le Fur Y,Dalmasso C,Cozzone PJ,Bendahan D

    更新日期:2010-07-01 00:00:00

  • Manganese-enhanced magnetic resonance imaging for in vivo assessment of damage and functional improvement following spinal cord injury in mice.

    abstract::In past decades, much effort has been invested in developing therapies for spinal injuries. Lack of standardization of clinical read-out measures, however, makes direct comparison of experimental therapies difficult. Damage and therapeutic effects in vivo are routinely evaluated using rather subjective behavioral test...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20888

    authors: Stieltjes B,Klussmann S,Bock M,Umathum R,Mangalathu J,Letellier E,Rittgen W,Edler L,Krammer PH,Kauczor HU,Martin-Villalba A,Essig M

    更新日期:2006-05-01 00:00:00

  • A comprehensive approach for correcting voxel-wise b-value errors in diffusion MRI.

    abstract:PURPOSE:In diffusion MRI, the actual b-value played out on the scanner may deviate from the nominal value due to magnetic field imperfections. A simple image-based correction method for this problem is presented. METHODS:The apparent diffusion constant (ADC) of a water phantom was measured voxel-wise along 64 diffusio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28078

    authors: Lee Y,Kettinger AO,Wilm BJ,Deichmann R,Weiskopf N,Lambert C,Pruessmann KP,Nagy Z

    更新日期:2020-06-01 00:00:00

  • Application of DENSE-MR-elastography to the human heart.

    abstract::Typically, MR-elastography (MRE) encodes the propagation of monochromatic acoustic waves in the MR-phase images via sinusoidal gradients characterized by a detection frequency equal to the frequency of the mechanical vibration. Therefore, the echo time of a conventional MRE sequence is typically longer than the vibrat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22124

    authors: Robert B,Sinkus R,Gennisson JL,Fink M

    更新日期:2009-11-01 00:00:00

  • Apparent propagator anisotropy from single-shell diffusion MRI acquisitions.

    abstract:PURPOSE:The apparent propagator anisotropy (APA) is a new diffusion MRI metric that, while drawing on the benefits of the ensemble averaged propagator anisotropy (PA) compared to the fractional anisotropy (FA), can be estimated from single-shell data. THEORY AND METHODS:Computation of the full PA requires acquisition ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28620

    authors: Aja-Fernández S,Tristán-Vega A,Jones DK

    更新日期:2020-12-13 00:00:00

  • Factors influencing the accuracy and precision of velocity-encoded phase imaging.

    abstract::Velocity-encoded phase contrast imaging is being used increasingly in clinical imaging for quantization of blood flow. In this study, the accuracy and precision of ascending aorta flow measurements were found to depend on several subtle aspects of the scan prescription and image analysis. While the usual scan paramete...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910260115

    authors: Buonocore MH,Bogren H

    更新日期:1992-07-01 00:00:00

  • B factor dependence of the temporal characteristics of brain activation using dynamic apparent diffusion coefficient contrast.

    abstract::Functional MRI studies to date have been generally performed using the blood oxygenation level dependent (BOLD) contrast mechanism. Recently, it has been proposed that dynamic change in the apparent diffusion coefficient (ADC), measured using intravoxel incoherent motion (IVIM) weighting, can be used as a robust funct...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20293

    authors: Harshbarger TB,Song AW

    更新日期:2004-12-01 00:00:00

  • Relaxation effects of ferucarbotran-labeled mesenchymal stem cells at 1.5T and 3T: discrimination of viable from lysed cells.

    abstract::Human mesenchymal stem cells (hMSCs) were labeled with Ferucarbotran by simple incubation and cultured for up to 14 d. Iron content was determined by spectrometry and the intracellular localization of the contrast agent uptake was studied by electron and confocal microscopy. At various time points after labeling, rang...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22011

    authors: Henning TD,Wendland MF,Golovko D,Sutton EJ,Sennino B,Malek F,Bauer JS,McDonald DM,Daldrup-Link H

    更新日期:2009-08-01 00:00:00

  • Phase-sensitive inversion recovery for myocardial T1 mapping with motion correction and parametric fitting.

    abstract::The assessment of myocardial fibrosis and extracellular volume requires accurate estimation of myocardial T1 s. While image acquisition using the modified Look-Locker inversion recovery technique is clinically feasible for myocardial T1 mapping, respiratory motion can limit its applicability. Moreover, the conventiona...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24385

    authors: Xue H,Greiser A,Zuehlsdorff S,Jolly MP,Guehring J,Arai AE,Kellman P

    更新日期:2013-05-01 00:00:00

  • Evaluation of acute brain edema using quantitative magnetic resonance imaging: effects of pretreatment with dexamethasone.

    abstract::We developed a quantitative magnetic resonance imaging method to permit a rapid assessment of brain water content during osmotic brain edema produced by intraperitoneal (ip) injection of distilled water. Fifteen minutes after water injection, the normalized mean image intensity (MIn) from a spin-echo pulse sequence (T...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910240107

    authors: Olson JE,Katz-Stein A,Reo NV,Jolesz FA

    更新日期:1992-03-01 00:00:00

  • MR elastography for evaluating regeneration of tissue-engineered cartilage in an ectopic mouse model.

    abstract:PURPOSE:The purpose of the present study was to apply noninvasive methods for monitoring regeneration and mechanical properties of tissue-engineered cartilage in vivo at different growth stages using MR elastography (MRE). METHODS:Three types of scaffolds, including silk, collagen, and gelatin seeded by human mesenchy...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25745

    authors: Khalilzad-Sharghi V,Han Z,Xu H,Othman SF

    更新日期:2016-03-01 00:00:00

  • Diffusion-weighted imaging of the human optic nerve: a new approach to evaluate optic neuritis in multiple sclerosis.

    abstract::The apparent diffusion coefficient (ADC) in the optic nerve was measured from diffusion-weighted magnetic resonance imaging using an intravoxel incoherent motion (IVIM) sequence. The subjects were seven normal volunteers and eight patients with multiple sclerosis (MS) with a total of four optic nerves with acute neuri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380317

    authors: Iwasawa T,Matoba H,Ogi A,Kurihara H,Saito K,Yoshida T,Matsubara S,Nozaki A

    更新日期:1997-09-01 00:00:00