Abstract:
PURPOSE:Acquisition of high-resolution imaging data using multiple excitations without the sensitivity to fluctuations of the transverse magnetization phase, which is a major problem of multi-shot MRI. THEORY AND METHODS:The concept of superresolution MRI based on microscopic tagging is analyzed using an analogy with the optical method of structured illumination. Sinusoidal tagging is shown to provide subpixel resolution by mixing of neighboring spatial frequency (k-space) bands. It represents a phaseless modulation added on top of the standard Fourier encoding, which allows the phase fluctuations to be discarded at an intermediate reconstruction step. Improvements are proposed to correct for tag distortions due to magnetic field inhomogeneity and to avoid the propagation of Gibbs ringing from intermediate low-resolution images to the final image. The method was applied to diffusion-weighted EPI. RESULTS:Artifact-free superresolution images can be obtained despite a finite duration of the tagging sequence and related pattern distortions by a field map based phase correction of band-wise reconstructed images. The ringing effect present in the intermediate images can be suppressed by partial overlapping of the mixed k-space bands in combination with an adapted filter. High-resolution diffusion-weighted images of the human head were obtained with a three-shot EPI sequence despite motion-related phase fluctuations between the shots. CONCLUSION:Due to its phaseless character, tagging-based sub-pixel encoding is an alternative to k-space segmenting in the presence of unknown phase fluctuations, in particular those due to motion under strong diffusion gradients. Proposed improvements render the method practicable in realistic conditions.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Hennel F,Tian R,Engel M,Pruessmann KPdoi
10.1002/mrm.27209subject
Has Abstractpub_date
2018-12-01 00:00:00pages
2384-2392issue
6eissn
0740-3194issn
1522-2594journal_volume
80pub_type
杂志文章abstract:PURPOSE:To investigate for the first time the feasibility of aortic four-dimensional (4D) flow at 7T, both contrast enhanced (CE) and non-CE. To quantify the signal-to-noise ratio (SNR) in aortic 4D flow as a function of field strength and CE with gadobenate dimeglumine (MultiHance). METHODS:Six healthy male volunteer...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25317
更新日期:2015-05-01 00:00:00
abstract::Noise in the composite magnitude signal from multiple-coil systems is usually assumed to follow a noncentral χ distribution when sum of squares is used to combine images sensed at different coils. However, this is true only if the variance of noise is the same for all coils, and no correlation exists between them. We ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.23020
更新日期:2012-02-01 00:00:00
abstract:PURPOSE:To test octafluorocyclobutane (OFCB) as an inhalation contrast agent for fluorine-19 MRI of the lung, and to compare the image quality of OFCB scans with perfluoropropane (PFP) scans THEORY AND METHODS: After normalizing for the number of signal averages, a theoretical comparison between the OFCB signal-to-nois...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28473
更新日期:2021-02-01 00:00:00
abstract:PURPOSE:To evaluate the role of true diffusion and flow-related pseudodiffusion in cerebral blood flow (CBF) quantification using arterial spin labeling (ASL) with single-shot or segmented 3D gradient and spin echo (GRASE) readouts. THEORY:The extended phase graph (EPG) algorithm, originally designed to model the effe...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27058
更新日期:2018-08-01 00:00:00
abstract::The prebolus technique allows one to quantify perfusion in the human heart with a low variability by means of MRI. In this study the prebolus technique was used to determine quantitative perfusion values in the human heart under adenosine stress and to measure the myocardial perfusion reserve (MPR). Twelve healthy vol...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21020
更新日期:2006-10-01 00:00:00
abstract:PURPOSE:To develop a fast and accurate method for 3D T2 mapping of prostate cancer using undersampled acquisition and dictionary-based fitting. METHODS:3D high-resolution T2 -weighted images (0.9 × 0.9 × 3 mm3 ) were obtained with a multishot T2 -prepared balanced steady-state free precession (T2 -prep-bSSFP) acquisit...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27540
更新日期:2019-03-01 00:00:00
abstract::The goal of this work was to develop an MRI method for mapping the clearance of interstitial macromolecular plasma proteins after their extravasation from permeable blood vessels. To that end, a well-defined window of exposure to elevated blood levels was generated by inducing rapid clearance of macromolecular contras...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10638
更新日期:2003-11-01 00:00:00
abstract:PURPOSE:To propose a phase error correction scheme for monopolar time-interleaved multi-echo gradient echo water-fat imaging that allows accurate and robust complex-based quantification of the proton density fat fraction (PDFF). METHODS:A three-step phase correction scheme is proposed to address a) a phase term induce...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26485
更新日期:2017-09-01 00:00:00
abstract:PURPOSE:High field T2* -weighted MR images of the cerebral cortex are increasingly used to study tissue susceptibility changes related to aging or pathologies. This paper presents a novel automated method for the computation of quantitative cortical measures and group-wise comparison using 7 Tesla T2* -weighted magnitu...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25397
更新日期:2015-07-01 00:00:00
abstract::Perfusion imaging with pulsed arterial spin labeling techniques, like flow-sensitive alternating inversion recovery (FAIR), may suffer from inflow of fresh, i.e., unlabeled, spins. Inflow of fresh spins is caused by the arrival of unlabeled spins in the image slice and can lead to underestimation of the perfusion if n...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20480
更新日期:2005-06-01 00:00:00
abstract::The long readout times of single-shot acquisitions and the high field strengths desired for functional MRI (fMRI) using blood oxygenation level-dependent (BOLD) contrast make functional scans sensitive to magnetic field inhomogeneity. If it is not corrected during image reconstruction, field inhomogeneity can cause ge...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20079
更新日期:2004-06-01 00:00:00
abstract:PURPOSE:To integrate markerless head motion tracking with prospectively corrected neuroanatomical MRI sequences and to investigate high-frequency motion correction during imaging echo trains. METHODS:A commercial 3D surface tracking system, which estimates head motion by registering point cloud reconstructions of the ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27705
更新日期:2019-07-01 00:00:00
abstract:PURPOSE:Sensitivity encoding (SENSE) reconstruction of multiband echo planar imaging (EPI) may cause artifacts when simultaneously excited slices require different phase correction to remove the EPI-specific ghost shifted by half of the matrix size (N). We propose a simplified solution of this problem that combines SEN...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25915
更新日期:2016-09-01 00:00:00
abstract::Traditionally, the method of nonlinear least squares (NLLS) analysis has been used to estimate the parameters obtained from exponential decay data. In this study, we evaluated the use of Bayesian probability theory to analyze such data; specifically, that resulting from intravoxel incoherent motion NMR experiments. An...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910290510
更新日期:1993-05-01 00:00:00
abstract::Brain water diffusion in response to transient global ischemia (12 min), reperfusion (60 min), and cardiac arrest was monitored by localized proton magnetic resonance spectroscopy. The trace of the apparent diffusion coefficient tensor (ADC(Av)) was determined at high temporal resolution (10 sec) to assess the putativ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199910)42:4<798::aid-mrm23
更新日期:1999-10-01 00:00:00
abstract:PURPOSE:Correlation imaging is a previously developed high-speed MRI framework that converts parallel imaging reconstruction into the estimate of correlation functions. The presented work aims to demonstrate this framework can provide a speed gain over parallel imaging by estimating k-space variant correlation function...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26818
更新日期:2018-03-01 00:00:00
abstract:PURPOSE:Conventional 31 P chemical shift imaging is time-consuming and yields only limited spatial resolution. The purpose of this study was to demonstrate feasibility of 31 P echo-planar spectroscopic imaging (EPSI) in vivo at 7T. METHODS:A 3D 31 P EPSI sequence with trapezoidal-shaped gradient pulses was implemented...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26785
更新日期:2018-03-01 00:00:00
abstract::Fast proton magnetic resonance spectroscopic imaging (MRSI) using a multi-element head-coil array is examined with respect to three aspects: the coil design, the use of an appropriate signal combination method, and the design of the MRSI pulse sequence itself. An eight-element head-coil array has been developed to inc...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910400204
更新日期:1998-08-01 00:00:00
abstract::The chemical shift of water and fat resonances in proton MRI allows separation of water and fat signal from chemical shift encoded data. This work describes an automatic method that produces separate water and fat images as well as quantitative maps of fat signal fraction and T2* from complex multiecho gradient-recall...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.23185
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Quantitative evaluation of dynamic contrast enhanced MRI (DCE-MRI) allows for estimating perfusion, vessel permeability, and tissue volume fractions by fitting signal intensity curves to pharmacokinetic models. These compart mental models assume rapid equilibration of contrast agent within each voxel. However, ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26995
更新日期:2018-07-01 00:00:00
abstract:PURPOSE:Lung pO2 mapping with (3)He MRI assumes that the sources of signal decay with time during a breath-hold are radiofrequency depolarization and oxygen-dependent T1 relaxation, but the method is sensitive to other sources of spatio-temporal signal change such as diffusion. The purpose of this work was to assess th...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24779
更新日期:2014-03-01 00:00:00
abstract::Two NMR experiments are described that use ac field gradients to measure flow velocities. Both experiments perform no spacial localization; instead, fluid velocity is converted to a resonance frequency shift. Thus, by Fourier transformation of a single FID or echo train the distribution of velocities is available. The...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910040308
更新日期:1987-03-01 00:00:00
abstract:PURPOSE:To accelerate the acquisition of J-resolved proton magnetic resonance spectroscopic imaging (1 H-MRSI) data for high-resolution mapping of brain metabolites and neurotransmitters. METHODS:The proposed method used a subspace model to represent multidimensional spatiospectral functions, which significantly reduc...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28413
更新日期:2021-01-01 00:00:00
abstract:PURPOSE:To assess the risk of radiofrequency (RF)-induced heating in patients with MR-conditional pacemaker (PM) systems, in the presence of another lead abandoned from a previous implant. METHODS:Four commercial pacemaker leads were placed beside a MR-conditional PM system, inside a human trunk simulator. The phantom...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25106
更新日期:2015-01-01 00:00:00
abstract::Mathematical models are required to estimate kinetic parameters of [1-(13)C] pyruvate-lactate interconversion from magnetic resonance spectroscopy data. One- or two-way exchange models utilizing a hypothetical approximation to the true arterial input function (AIF), (e.g. an ideal 'box-car' function) have been used pr...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24546
更新日期:2013-10-01 00:00:00
abstract::Homogeneous soft tissue, as regards its magnetic relaxation properties, is well-modeled by solutions of cross-linked protein (see Koenig and Brown, Prog. NMR Spectr. 22, 487 (1991)). Interactions at the solute-solvent interface alter the hydrodynamics of solvent water, and also couple the solute and solvent proton Zee...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910300606
更新日期:1993-12-01 00:00:00
abstract::The manufacturing of intravascular imaging coils poses several challenges. Due to their size, it can be difficult to incorporate local matching networks and signal amplifiers. The goal of this study is to investigate tuning and amplification strategies for intravascular coils and to assess the signal-to-noise benefits...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24134
更新日期:2012-11-01 00:00:00
abstract:PURPOSE:To improve multichannel compressed sensing (CS) reconstruction for MR proton resonance frequency (PRF) shift thermography, with application to MRI-induced RF heating evaluation and MR guided high intensity focused ultrasound (MRgFUS) temperature monitoring. METHODS:A new compressed sensing reconstruction is pr...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27666
更新日期:2019-06-01 00:00:00
abstract::A pulse sequence is presented for obtaining a single image with combined T1/T2 weighting. T2 relaxation is made to increase intensity, in cooperation with the effect of T1 relaxation, by providing T2 weighting with a 90 degrees-180 degrees-90 degrees driven inversion pulse triplet in an inversion recovery method. Unli...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910150307
更新日期:1990-09-01 00:00:00
abstract:PURPOSE:To systematically evaluate the dependence of intravoxel-incoherent-motion (IVIM) parameters on the b-value threshold separating the perfusion and diffusion compartment, and to implement and test an algorithm for the standardized computation of this threshold. METHODS:Diffusion weighted images of the upper abdo...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25506
更新日期:2015-11-01 00:00:00