Accelerated J-resolved 1 H-MRSI with limited and sparse sampling of ( k , t 1 , t 2 -space.

Abstract:

PURPOSE:To accelerate the acquisition of J-resolved proton magnetic resonance spectroscopic imaging (1 H-MRSI) data for high-resolution mapping of brain metabolites and neurotransmitters. METHODS:The proposed method used a subspace model to represent multidimensional spatiospectral functions, which significantly reduced the number of parameters to be determined from J-resolved 1 H-MRSI data. A semi-LASER-based (Localization by Adiabatic SElective Refocusing) echo-planar spectroscopic imaging (EPSI) sequence was used for data acquisition. The proposed data acquisition scheme sampled k , t 1 , t 2 -space in variable density, where t1 and t2 specify the J-coupling and chemical-shift encoding times, respectively. Selection of the J-coupling encoding times (or, echo time values) was based on a Cramer-Rao lower bound analysis, which were optimized for gamma-aminobutyric acid (GABA) detection. In image reconstruction, parameters of the subspace-based spatiospectral model were determined by solving a constrained optimization problem. RESULTS:Feasibility of the proposed method was evaluated using both simulated and experimental data from a spectroscopic phantom. The phantom experimental results showed that the proposed method, with a factor of 12 acceleration in data acquisition, could determine the distribution of J-coupled molecules with expected accuracy. In vivo study with healthy human subjects also showed that 3D maps of brain metabolites and neurotransmitters can be obtained with a nominal spatial resolution of 3.0 × 3.0 × 4.8 mm3 from J-resolved 1 H-MRSI data acquired in 19.4 min. CONCLUSIONS:This work demonstrated the feasibility of highly accelerated J-resolved 1 H-MRSI using limited and sparse sampling of k , t 1 , t 2 -space and subspace modeling. With further development, the proposed method may enable high-resolution mapping of brain metabolites and neurotransmitters in clinical applications.

journal_name

Magn Reson Med

authors

Tang L,Zhao Y,Li Y,Guo R,Clifford B,El Fakhri G,Ma C,Liang ZP,Luo J

doi

10.1002/mrm.28413

subject

Has Abstract

pub_date

2021-01-01 00:00:00

pages

30-41

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

85

pub_type

杂志文章
  • Spin-lattice relaxation time measurements using hybrid CSI--phantom study.

    abstract::The spin-lattice relaxation time T1 of multicomponent tissues is often determined by fitting relaxation data to monoexponential functions. This process can lead to large errors in the relaxation time. We describe a procedure using chemical-shift imaging (CSI) which separates the NMR signal into water and lipid compone...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910130307

    authors: Hornak JP,Smith AC,Szumowski J

    更新日期:1990-03-01 00:00:00

  • Fast 1H spectroscopic imaging using a multi-element head-coil array.

    abstract::Fast proton magnetic resonance spectroscopic imaging (MRSI) using a multi-element head-coil array is examined with respect to three aspects: the coil design, the use of an appropriate signal combination method, and the design of the MRSI pulse sequence itself. An eight-element head-coil array has been developed to inc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400204

    authors: Schäffter T,Börnert P,Leussler C,Carlsen IC,Leibfritz D

    更新日期:1998-08-01 00:00:00

  • Parallel MRI reconstruction using variance partitioning regularization.

    abstract::Multiple receivers can be utilized to enhance the spatiotemporal resolution of MRI by employing the parallel imaging technique. Previously, we have reported the L-curve Tikhonov regularization technique to mitigate noise amplification resulting from the geometrical correlations between channels in a coil array. Nevert...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21356

    authors: Lin FH,Wang FN,Ahlfors SP,Hämäläinen MS,Belliveau JW

    更新日期:2007-10-01 00:00:00

  • Dynamic oxygen-enhanced MRI reflects diffusing capacity of the lung.

    abstract::The purpose of this study was to demonstrate the feasibility of dynamic oxygen-enhanced MRI in a clinical setting. We hypothesized that dynamic oxygen enhancement can reflect the regional diffusing capacity of the lung. Ten patients with pulmonary emphysema and seven healthy volunteers were examined with a respiratory...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10168

    authors: Ohno Y,Hatabu H,Takenaka D,Van Cauteren M,Fujii M,Sugimura K

    更新日期:2002-06-01 00:00:00

  • Interactive coronary MRI.

    abstract::The acquisition of complete three-dimensional (3D), segmented gradient-echo data sets to visualize the coronary arteries can be both time consuming and sensitive to motion, even with use of multiple breath-holding or respiratory gating. An alternate hybrid approach is demonstrated here, in which real-time interactive ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400115

    authors: Hardy CJ,Darrow RD,Pauly JM,Kerr AB,Dumoulin CL,Hu BS,Martin KM

    更新日期:1998-07-01 00:00:00

  • The MR tomograph as a sound generator: fMRI tool for the investigation of the auditory cortex.

    abstract::An automatic fMRI protocol for the investigation of the human auditory cortex has been developed. For the activation of the auditory system, the scanner noise itself is the source of sound. Rapid switching of B0 gradients allows the generation of tones of defined frequencies and amplitude on a conventional scanner wit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400621

    authors: Bilecen D,Radü EW,Scheffler K

    更新日期:1998-12-01 00:00:00

  • Human whole blood T2 relaxometry at 3 Tesla.

    abstract::A precise understanding of human blood spin-spin relaxation is of major importance for numerous applications, particularly functional magnetic resonance imaging (fMRI), which is increasingly performed at 3 Tesla. It is well known that T2 measured from partially deoxygenated blood depends on the Carr-Purcell Meiboom-Gi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21858

    authors: Chen JJ,Pike GB

    更新日期:2009-02-01 00:00:00

  • A pitfall associated with lactate detection using stimulated-echo proton spectroscopy.

    abstract::At TE values of 136 ms, it has recently been shown that the lactate methyl signal, when obtained with a stimulated-echo (STE) sequence, is modulated at the zero-quantum (ZQ) frequency when TM is varied. Here we describe an additional modulation of the ZQ lactate signal, due to spin-spin coupling, that results in a 10-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170223

    authors: Sotak CH,Alger JR

    更新日期:1991-02-01 00:00:00

  • Capillarization of the sinusoids in liver fibrosis: noninvasive assessment with contrast-enhanced MRI in the rabbit.

    abstract::Sinusoidal capillarization induces microcirculatory changes in liver cirrhosis and fibrosis. The purpose of this study was to assess whether contrast-enhanced MRI can be used to demonstrate the effects of sinusoidal capillarization in liver fibrosis. Dynamic MRI after injection of a low-molecular-weight contrast agent...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10420

    authors: Van Beers BE,Materne R,Annet L,Hermoye L,Sempoux C,Peeters F,Smith AM,Jamart J,Horsmans Y

    更新日期:2003-04-01 00:00:00

  • Image contrast using the secondary and tertiary eigenvectors in diffusion tensor imaging.

    abstract::Diffusion tensor imaging (DTI) is a new imaging modality that can provide unique information on brain white matter anatomy. Measurements of water diffusion constant along multiple axes are fitted to a tensor model, from which the diffusion anisotropy and dominant fiber orientation can be estimated. Even though the ten...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20767

    authors: Zhang J,van Zijl PC,Mori S

    更新日期:2006-02-01 00:00:00

  • Numerical simulations of carotid MRI quantify the accuracy in measuring atherosclerotic plaque components in vivo.

    abstract:PURPOSE:Atherosclerotic carotid plaques can be quantified in vivo by MRI. However, the accuracy in segmentation and quantification of components such as the thin fibrous cap (FC) and lipid-rich necrotic core (LRNC) remains unknown due to the lack of a submillimeter scale ground truth. METHODS:A novel approach was take...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24905

    authors: Nieuwstadt HA,Geraedts TR,Truijman MT,Kooi ME,van der Lugt A,van der Steen AF,Wentzel JJ,Breeuwer M,Gijsen FJ

    更新日期:2014-07-01 00:00:00

  • Investigation of human cervical and upper thoracic spinal cord motion: implications for imaging spinal cord structure and function.

    abstract::Spinal cord (SC) motion is thought to be the dominant source of error in current diffusion and spinal functional MRI (fMRI) methods. However, until now, such motion has not been well characterized in three dimensions. While previous studies have predominantly examined motion in the superior/inferior (S/I) direction, t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21260

    authors: Figley CR,Stroman PW

    更新日期:2007-07-01 00:00:00

  • Proton NMR spectroscopy of solvent-saturable resonances: a new approach to study pH effects in situ.

    abstract::It is shown that the effect of pH changes can be measured in proton NMR spectra through the pH sensitivity of the signal intensities of metabolite protons exchanging with water. To observe this phenomenon, pulse sequences must be used that can sensitively observe these exchangeable protons under physiological conditio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400105

    authors: Mori S,Eleff SM,Pilatus U,Mori N,van Zijl PC

    更新日期:1998-07-01 00:00:00

  • Localized 1H NMR measurements of 2-pyrrolidinone in human brain in vivo.

    abstract::Localized 1H NMR homonuclear J editing spectroscopy was used to measure the concentration of 2-pyrrolidinone (PRDN) in the human occipital lobe of five normal and six epileptic subjects taking vigabatrin. PRDN is a lactam cyclization product of gamma-aminobutyric acid (GABA). From a localized volume of 13.5 cm3 in the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199905)41:5<889::aid-mrm6>

    authors: Hyder F,Petroff OA,Mattson RH,Rothman DL

    更新日期:1999-05-01 00:00:00

  • Arrays of mutually coupled receiver coils: theory and application.

    abstract::Specialized receiver coils having a small sensitive region can provide an improvement in SNR for MR imaging and spectroscopy, at the expense of limiting the usable field of view. This work presents a technique for designing coil arrays that allows the size and location of the sensitive region to be selected remotely. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170128

    authors: Wright SM,Magin RL,Kelton JR

    更新日期:1991-01-01 00:00:00

  • Evaluation of multicontrast MRI including fat suppression and inversion recovery spin echo for identification of intra-plaque hemorrhage and lipid core in human carotid plaque using the mahalanobis distance measure.

    abstract::Intra-plaque hemorrhage (IPH) and lipid core, characteristics of rupture prone carotid plaques, are often visualized in vivo with MRI using T1 weighted gradient and spin echo, respectively. Increasing magnetic field strength may help to identify IPH and lipid core better. As a proof of concept, automatic segmentation ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23191

    authors: te Boekhorst BC,van 't Klooster R,Bovens SM,van de Kolk KW,Cramer MJ,van Oosterhout MF,Doevendans PA,van der Geest RJ,Pasterkamp G,van Echteld CJ

    更新日期:2012-06-01 00:00:00

  • Cerebral T1rho relaxation time increases immediately upon global ischemia in the rat independently of blood glucose and anoxic depolarization.

    abstract::Time-dependent changes of T1 in the rotating frame (T1rho), diffusion, T2, and magnetization transfer contrast on cardiac arrest-induced global ischemia in rat were investigated. T1rho, as acquired with spin lock amplitudes >0.6 G, started to increase 10-20 sec after cardiac arrest followed by an increase within 3-4 m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1228

    authors: Kettunen MI,Gröhn OH,Penttonen M,Kauppinen RA

    更新日期:2001-09-01 00:00:00

  • Cardiac tagging with breath-hold cine MRI.

    abstract::A method is presented for measuring myocardial deformation in a breath-hold with tagged cine MRI. Tagged cine images of human hearts are obtained in arbitrary oblique planes on a standard imager with as few as four heartbeats. The scan time has been reduced 16- to 64-fold from previous techniques. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910280214

    authors: McVeigh ER,Atalar E

    更新日期:1992-12-01 00:00:00

  • Improved myocardial tagging contrast.

    abstract::Myocardial tagging is a new noninvasive MRI method that allows the study of myocardial motion with high accuracy. However, with conventional tagging techniques tagging contrast is impaired at later heart phases due to longitudinal relaxation. An improved method, called Complementary SPAtial Modulation of Magnetization...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300207

    authors: Fischer SE,McKinnon GC,Maier SE,Boesiger P

    更新日期:1993-08-01 00:00:00

  • Low-power NMR volume selection by slicing z magnetization.

    abstract::A novel method for reducing the rf power requirements of selective pulses employed for z magnetization slice inversion in localized NMR spectroscopy is presented. Following slice preparation by the use of frequency-incremented sinc pulses, the slice gradient is reduced, which narrows the frequency width of the slice. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050610

    authors: Brereton IM,Brooks WM,Marshman MF,Field J,Doddrell DM

    更新日期:1987-12-01 00:00:00

  • Multi-band MR fingerprinting (MRF) ASL imaging using artificial-neural-network trained with high-fidelity experimental data.

    abstract:PURPOSE:We aim to leverage the power of deep-learning with high-fidelity training data to improve the reliability and processing speed of hemodynamic mapping with MR fingerprinting (MRF) arterial spin labeling (ASL). METHODS:A total of 15 healthy subjects were studied on a 3T MRI. Each subject underwent 10 runs of a m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28560

    authors: Fan H,Su P,Huang J,Liu P,Lu H

    更新日期:2021-04-01 00:00:00

  • Direct CSF injection of MnCl(2) for dynamic manganese-enhanced MRI.

    abstract::MnCl(2) was injected intrathecally through the cisterna magna in rats, allowing infusion of divalent manganese ions (Mn(++)) into the CSF space and thence into the brain, without breaking the blood-brain barrier (BBB). Mn(++) uptake and washout dynamics in the brain were measured by serial T(1)-weighted MRI and EPI T(...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20047

    authors: Liu CH,D'Arceuil HE,de Crespigny AJ

    更新日期:2004-05-01 00:00:00

  • Transceive surface coil array for magnetic resonance imaging of the human brain at 4 T.

    abstract::As the static magnetic field strength used in human magnetic resonance imaging increases, the wavelength of the corresponding radiofrequency field becomes comparable to the dimensions of the coil and volume of interest. The dielectric resonance effects that arise in this full wavelength regime may be partially compens...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20583

    authors: Pinkerton RG,Barberi EA,Menon RS

    更新日期:2005-08-01 00:00:00

  • Perfusion-based functional magnetic resonance imaging with single-shot RARE and GRASE acquisitions.

    abstract::For perfusion-based functional magnetic resonance imaging, the previously introduced flow-sensitive alternating inversion recovery (FAIR) technique is combined with single-shot RARE (rapid acquisition with relaxation enhancement) and GRASE (gradient and spin echo) imaging sequences. The advantages of these sequences c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199901)41:1<132::aid-mrm18

    authors: Crelier GR,Hoge RD,Munger P,Pike GB

    更新日期:1999-01-01 00:00:00

  • Optimum flip-angles for exciting NMR with uncertain T1 values.

    abstract::T1 is often ill-determined. This means that an Ernst angle excitation often cannot be precisely defined for the simple pulse and acquire experiment. Here, published 31P T1 values of metabolites in human muscle, liver, heart, and brain are archived, some new data on heart and brain added, and overall confidence interva...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320120

    authors: Bottomley PA,Ouwerkerk R

    更新日期:1994-07-01 00:00:00

  • Visualization of free radical reactions in an aqueous sample irradiated by 290 MeV carbon beam.

    abstract::The detection of free radical reactions in a gelatin sample irradiated by a heavy-ion beam was tested using electron paramagnetic resonance (EPR) spectroscopic and MRI methods. Geometry and the amount of free radical generation in a sample are described. A reaction mixture containing glutathione and a nitroxyl radical...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21958

    authors: Matsumoto K,Nagata K,Yamamoto H,Endo K,Anzai K,Aoki I

    更新日期:2009-05-01 00:00:00

  • Fast, pseudo-continuous arterial spin labeling for functional imaging using a two-coil system.

    abstract::A fast, two-coil, pseudo-continuous labeling scheme is presented. This new scheme permits the collection of a multislice subtraction pair in <3 s, depending on the subject's arterial transit times. The method consists of acquiring both control and tag images immediately after a labeling period that matches the arteria...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10733

    authors: Hernandez-Garcia L,Lee GR,Vazquez AL,Noll DC

    更新日期:2004-03-01 00:00:00

  • Quantification of the pulse wave velocity of the descending aorta using axial velocity profiles from phase-contrast magnetic resonance imaging.

    abstract::The pulse wave velocity (PWV) of aortic blood flow is considered a surrogate for aortic compliance. A new method using phase-contrast (PC)-MRI is presented whereby the spatial and temporal profiles of axial velocity along the descending aorta can be analyzed. Seventeen young healthy volunteers (the YH group), six olde...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21034

    authors: Yu HY,Peng HH,Wang JL,Wen CY,Tseng WY

    更新日期:2006-10-01 00:00:00

  • High-resolution Fourier-encoded sub-millisecond echo time musculoskeletal imaging at 3 Tesla and 7 Tesla.

    abstract:PURPOSE:The feasibility of imaging musculoskeletal fibrous tissue components, such as menisci, ligaments, and tendons, with a conventional spoiled gradient echo technique is explored in vivo at 3 T and 7 T. METHODS:To this end, the echo time (TE1 ) of a conventional Fourier-encoded multicontrast three-dimensional SGPR...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24578

    authors: Deligianni X,Bär P,Scheffler K,Trattnig S,Bieri O

    更新日期:2013-11-01 00:00:00

  • In vivo whole-blood T2 versus HbO2 calibration by modulating blood oxygenation level in the femoral vein through intermittent cuff occlusion.

    abstract:PURPOSE:To investigate the feasibility of estimating calibration constants (K and T2o ) in vivo for converting whole-blood T2 to blood hemoglobin oxygen saturation (HbO2 ) according to the Luz-Meiboom model, 1/T2=1/T2o+K(1-HbO2)2, where K and T2o are relaxivity and transverse relaxation time of fully saturated blood, r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26885

    authors: Langham MC,Rodríguez-Soto AE,Schwartz N,Wehrli FW

    更新日期:2018-04-01 00:00:00