SENSE reconstruction for multiband EPI including slice-dependent N/2 ghost correction.

Abstract:

PURPOSE:Sensitivity encoding (SENSE) reconstruction of multiband echo planar imaging (EPI) may cause artifacts when simultaneously excited slices require different phase correction to remove the EPI-specific ghost shifted by half of the matrix size (N). We propose a simplified solution of this problem that combines SENSE unfolding with the EPI phase correction in the image domain. THEORY AND METHODS:Slice-dependent phase correction was included in equations linking folded slice images reconstructed separately from even and odd echoes of all receivers with the true images of each slice. Compared with the previously proposed combination of ghost suppression with SENSE based on a direct image fit to echo data, our method reduces the problem complexity by N(2) /4. It was applied to reconstruct images of phantoms and human brain. RESULTS:The proposed method tolerates high differences of phase correction between slices, which may result, e.g., from anisotropic gradient delay. It suppresses artifacts better than standard SENSE even when the latter is repeated with the ghost correction targeting each of the slices and works significantly faster than the direct fit version of ghost-correcting SENSE. CONCLUSION:With the proposed modification SENSE allows a rapid separation of slices simultaneously acquired with EPI even when the phase correction needed for each slice is different. Magn Reson Med 76:873-879, 2016. © 2015 Wiley Periodicals, Inc.

journal_name

Magn Reson Med

authors

Hennel F,Buehrer M,von Deuster C,Seuven A,Pruessmann KP

doi

10.1002/mrm.25915

subject

Has Abstract

pub_date

2016-09-01 00:00:00

pages

873-9

issue

3

eissn

0740-3194

issn

1522-2594

journal_volume

76

pub_type

杂志文章
  • Self-navigated 4D cartesian imaging of periodic motion in the body trunk using partial k-space compressed sensing.

    abstract:PURPOSE:To enable fast and flexible high-resolution four-dimensional (4D) MRI of periodic thoracic/abdominal motion for motion visualization or motion-corrected imaging. METHODS:We proposed a Cartesian three-dimensional k-space sampling scheme that acquires a random combination of k-space lines in the ky/kz plane. A p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26406

    authors: Küstner T,Würslin C,Schwartz M,Martirosian P,Gatidis S,Brendle C,Seith F,Schick F,Schwenzer NF,Yang B,Schmidt H

    更新日期:2017-08-01 00:00:00

  • Aortic 4D flow: quantification of signal-to-noise ratio as a function of field strength and contrast enhancement for 1.5T, 3T, and 7T.

    abstract:PURPOSE:To investigate for the first time the feasibility of aortic four-dimensional (4D) flow at 7T, both contrast enhanced (CE) and non-CE. To quantify the signal-to-noise ratio (SNR) in aortic 4D flow as a function of field strength and CE with gadobenate dimeglumine (MultiHance). METHODS:Six healthy male volunteer...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25317

    authors: Hess AT,Bissell MM,Ntusi NA,Lewis AJ,Tunnicliffe EM,Greiser A,Stalder AF,Francis JM,Myerson SG,Neubauer S,Robson MD

    更新日期:2015-05-01 00:00:00

  • Flexible cardiac T1 mapping using a modified Look-Locker acquisition with saturation recovery.

    abstract::A modified Look-Locker acquisition using saturation recovery (MLLSR) for breath-held myocardial T(1) mapping is presented. Despite its reduced dynamic range, saturation recovery enables substantially higher imaging efficiency than conventional inversion recovery T(1) mapping because it does not require time for magnet...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24137

    authors: Song T,Stainsby JA,Ho VB,Hood MN,Slavin GS

    更新日期:2012-03-01 00:00:00

  • Coronary MR angiography using image-based respiratory motion compensation with inline correction and fixed gating efficiency.

    abstract:PURPOSE:The purpose of this study was to evaluate a new inline motion compensation approach called image-based navigation with Constant Respiratory efficiency UsIng Single End-expiratory threshold (iNAV-CRUISE) for coronary MR angiography (CMRA). METHODS:The CRUISE gating technique was combined with iNAV motion correc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26678

    authors: Henningsson M,Smink J,van Ensbergen G,Botnar R

    更新日期:2018-01-01 00:00:00

  • Saturated double-angle method for rapid B1+ mapping.

    abstract::For in vivo magnetic resonance imaging at high field (> or =3 T) it is essential to consider the homogeneity of the active B(1) field (B(1)+), particularly if surface coils are used for RF transmission. A new method is presented for highly rapid B(1)+ magnitude mapping. It combines the double angle method with a B(1)-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20896

    authors: Cunningham CH,Pauly JM,Nayak KS

    更新日期:2006-06-01 00:00:00

  • Vessel-specific quantification of blood oxygenation with T2-relaxation-under-phase-contrast MRI.

    abstract:PURPOSE:Measurement of venous oxygenation (Yv) is a critical step toward quantitative assessment of brain oxygen metabolism, a key index in many brain disorders. The present study aims to develop a noninvasive, rapid, and reproducible method to measure Yv in a vessel-specific manner. THEORY:The method, T2-Relaxation-U...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24750

    authors: Krishnamurthy LC,Liu P,Ge Y,Lu H

    更新日期:2014-03-01 00:00:00

  • Fast 3D ultrashort echo-time spiral projection imaging using golden-angle: A flexible protocol for in vivo mouse imaging at high magnetic field.

    abstract:PURPOSE:To develop a fast three-dimensional (3D) k-space encoding method based on spiral projection imaging (SPI) with an interleaved golden-angle approach and to validate this novel sequence on small animal models. METHODS:A disk-like trajectory, in which each disk contained spirals, was developed. The 3D encoding wa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26263

    authors: Castets CR,Lefrançois W,Wecker D,Ribot EJ,Trotier AJ,Thiaudière E,Franconi JM,Miraux S

    更新日期:2017-05-01 00:00:00

  • Pulmonary artery imaging under free-breathing using golden-angle radial bSSFP MRI: a proof of concept.

    abstract:PURPOSE:To evaluate the feasibility of an improved motion and flow robust methodology for imaging the pulmonary vasculature using non-contrast-enhanced, free-breathing, golden-angle radial MRI. METHODS:Healthy volunteers (n = 10, age 46 ± 11 years, 50% female) and patients (n = 2, ages 27 and 84, both female) were ima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27177

    authors: Fyrdahl A,Vargas Paris R,Nyrén S,Holst K,Ugander M,Lindholm P,Sigfridsson A

    更新日期:2018-11-01 00:00:00

  • Fast 1H spectroscopic imaging using a multi-element head-coil array.

    abstract::Fast proton magnetic resonance spectroscopic imaging (MRSI) using a multi-element head-coil array is examined with respect to three aspects: the coil design, the use of an appropriate signal combination method, and the design of the MRSI pulse sequence itself. An eight-element head-coil array has been developed to inc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400204

    authors: Schäffter T,Börnert P,Leussler C,Carlsen IC,Leibfritz D

    更新日期:1998-08-01 00:00:00

  • Robust estimation of spatially variable noise fields.

    abstract::Consideration of spatially variable noise fields is becoming increasingly necessary in MRI given recent innovations in artifact identification and statistically driven image processing. Fast imaging methods enable study of difficult anatomical targets and improve image quality but also increase the spatial variability...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22013

    authors: Landman BA,Bazin PL,Smith SA,Prince JL

    更新日期:2009-08-01 00:00:00

  • The phenomenon of separate intra- and extracellular resonances of difluorophosphate in 31P and 19F NMR spectra of erythrocytes.

    abstract::Trifluoroacetate and trifluoroacetamide, when added to a suspension of human red blood cells, give rise to separate 19F NMR signals from the intra- and extracellular species. This phenomenon has recently been exploited for measuring the membrane potential of erythrocytes. However, the separation of the peaks was incor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910180119

    authors: Xu AS,Potts JR,Kuchel PW

    更新日期:1991-03-01 00:00:00

  • Conversion of arterial input functions for dual pharmacokinetic modeling using Gd-DTPA/MRI and 18F-FDG/PET.

    abstract::Reaching the full potential of magnetic resonance imaging (MRI)-positron emission tomography (PET) dual modality systems requires new methodologies in quantitative image analyses. In this study, methods are proposed to convert an arterial input function (AIF) derived from gadolinium-diethylenetriaminepentaacetic acid ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24318

    authors: Poulin E,Lebel R,Croteau E,Blanchette M,Tremblay L,Lecomte R,Bentourkia M,Lepage M

    更新日期:2013-03-01 00:00:00

  • Multivendor implementation and comparison of volumetric whole-brain echo-planar MR spectroscopic imaging.

    abstract:PURPOSE:To assess volumetric proton MR spectroscopic imaging (MRSI) of the human brain on multivendor MRI instruments. METHODS:Echo-planar spectroscopic imaging was developed on instruments from three manufacturers, with matched specifications and acquisition protocols that accounted for differences in sampling perfor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25510

    authors: Sabati M,Sheriff S,Gu M,Wei J,Zhu H,Barker PB,Spielman DM,Alger JR,Maudsley AA

    更新日期:2015-11-01 00:00:00

  • Dynamic per slice shimming for simultaneous brain and spinal cord fMRI.

    abstract:PURPOSE:Simultaneous brain and spinal cord functional MRI is emerging as a new tool to study the central nervous system but is challenging. Poor B0 homogeneity and small size of the spinal cord are principal obstacles to this nascent technology. Here we extend a dynamic shimming approach, first posed by Finsterbusch, b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27388

    authors: Islam H,Law CSW,Weber KA,Mackey SC,Glover GH

    更新日期:2019-02-01 00:00:00

  • Cocaine administration decreases functional connectivity in human primary visual and motor cortex as detected by functional MRI.

    abstract::Functional magnetic resonance imaging (fMRI) was conducted to observe the effects of cocaine administration on the physiological fluctuations of fMRI signal in two brain regions. Seven long-term cocaine users with an average age of 32 years and 8 years of cocaine use history were recruited for the study. A T2*-weighte...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/(sici)1522-2594(200001)43:1<45::aid-mrm6>3

    authors: Li SJ,Biswal B,Li Z,Risinger R,Rainey C,Cho JK,Salmeron BJ,Stein EA

    更新日期:2000-01-01 00:00:00

  • Constrained length minimum inductance gradient coil design.

    abstract::A gradient coil design algorithm capable of controlling the position of the homogeneous region of interest (ROI) with respect to the current-carrying wires is required for many advanced imaging and spectroscopy applications. A modified minimum inductance target field method that allows the placement of a set of constr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390214

    authors: Chronik BA,Rutt BK

    更新日期:1998-02-01 00:00:00

  • Motion-adaptive spatio-temporal regularization for accelerated dynamic MRI.

    abstract::Accelerated magnetic resonance imaging techniques reduce signal acquisition time by undersampling k-space. A fundamental problem in accelerated magnetic resonance imaging is the recovery of quality images from undersampled k-space data. Current state-of-the-art recovery algorithms exploit the spatial and temporal stru...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24524

    authors: Asif MS,Hamilton L,Brummer M,Romberg J

    更新日期:2013-09-01 00:00:00

  • Quantifying the effect of dobutamine stress on myocardial Pi and pH in healthy volunteers: A 31 P MRS study at 7T.

    abstract:PURPOSE:Phosphorus spectroscopy (31 P-MRS) is a proven method to probe cardiac energetics. Studies typically report the phosphocreatine (PCr) to adenosine triphosphate (ATP) ratio. We focus on another 31 P signal: inorganic phosphate (Pi), whose chemical shift allows computation of myocardial pH, with Pi/PCr providing ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28494

    authors: Apps A,Valkovič L,Peterzan M,Lau JYC,Hundertmark M,Clarke W,Tunnicliffe EM,Ellis J,Tyler DJ,Neubauer S,Rider OJ,Rodgers CT,Schmid AI

    更新日期:2021-03-01 00:00:00

  • Improved compressed sensing and super-resolution of cardiac diffusion MRI with structure-guided total variation.

    abstract:PURPOSE:Structure-guided total variation is a recently introduced prior that allows reconstruction of images using knowledge of the location and orientation of edges in a reference image. In this work, we demonstrate the advantages of a variant of structure-guided total variation known as directional total variation (D...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28245

    authors: Teh I,McClymont D,Carruth E,Omens J,McCulloch A,Schneider JE

    更新日期:2020-10-01 00:00:00

  • Toward 7T breast MRI clinical study: safety assessment using simulation of heterogeneous breast models in RF exposure.

    abstract:PURPOSE:To facilitate assessment of RF power deposition and temperature rise within the breast, we present a method to seamlessly join heterogeneous breast models with standard whole-body models and demonstrate simulations at 7 T. METHODS:Finite-difference time-domain electromagnetic and bioheat simulations are perfor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27395

    authors: Li X,Rispoli JV

    更新日期:2019-02-01 00:00:00

  • Multiclass imbalance learning: Improving classification of pediatric brain tumors from magnetic resonance spectroscopy.

    abstract:PURPOSE:Classification of pediatric brain tumors from 1 H-magnetic resonance spectroscopy (MRS) can aid diagnosis and management of brain tumors. However, varied incidence of the different tumor types leads to imbalanced class sizes and introduces difficulties in classifying rare tumor groups. This study assessed diffe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26318

    authors: Zarinabad N,Wilson M,Gill SK,Manias KA,Davies NP,Peet AC

    更新日期:2017-06-01 00:00:00

  • Hyperpolarized 13C NMR detects rapid drug-induced changes in cardiac metabolism.

    abstract:PURPOSE:The diseased myocardium lacks metabolic flexibility and responds to stimuli differently compared with healthy hearts. Here, we report the use of hyperpolarized 13C NMR spectroscopy to detect sudden changes in cardiac metabolism in isolated, perfused rat hearts in response to adrenergic stimulation. METHODS:Met...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25419

    authors: Khemtong C,Carpenter NR,Lumata LL,Merritt ME,Moreno KX,Kovacs Z,Malloy CR,Sherry AD

    更新日期:2015-08-01 00:00:00

  • Transcatheter intra-arterial perfusion (TRIP)-MRI biomarkers help detect immediate response to irreversible electroporation of rabbit VX2 liver tumor.

    abstract:PURPOSE:Irreversible electroporation (IRE) is a nonthermal tissue ablation technique that represents a promising treatment option for unresectable liver tumors, but the effectively treated zone cannot be reliably predicted. We investigate the potential benefit of transcatheter intra-arterial perfusion (TRIP) -MRI for t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28104

    authors: Figini M,Zhou K,Pan L,Sun C,Wang B,Hu S,Yang J,Shangguan J,Eresen A,Velichko Y,Yaghmai V,Zhang Z

    更新日期:2020-07-01 00:00:00

  • Macromolecule mapping of the brain using ultrashort-TE acquisition and reference-based metabolite removal.

    abstract:PURPOSE:To develop a practical method for mapping macromolecule distribution in the brain using ultrashort-TE MRSI data. METHODS:An FID-based chemical shift imaging acquisition without metabolite-nulling pulses was used to acquire ultrashort-TE MRSI data that capture the macromolecule signals with high signal-to-noise...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26896

    authors: Lam F,Li Y,Clifford B,Liang ZP

    更新日期:2018-05-01 00:00:00

  • Safety of gadolinium-DTPA: extended clinical experience.

    abstract::This review reports data on the general and renal tolerance of the paramagnetic contrast agent Gd-DTPA after intravenous administration. Gd-DTPA was administered usually at a dose level of 0.1-0.2 mmol/kg body wt (range: 0.005-0.25 mmol/kg body wt) in cranial, spinal and body MR indications. In phase I-IIIa studies a ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.1910220212

    authors: Niendorf HP,Haustein J,Cornelius I,Alhassan A,Clauss W

    更新日期:1991-12-01 00:00:00

  • In vitro 1H NMR "mapping" of human intervertebral discs.

    abstract::Human intervertebral discs were investigated by 1H NMR in vitro. The measured parameters of samples differently located in discs give the "maps" of discs. The spin-lattice relaxation-time maps show similar structure to dry matter and bound water maps, which might mean the future possibility to detect certain disc proc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030122

    authors: Furó I,Bobest M,Pócsik I,Tompa K

    更新日期:1986-02-01 00:00:00

  • iDQC anisotropy map imaging for tumor tissue characterization in vivo.

    abstract::Intermolecular double quantum coherences (iDQCs), signals that result from simultaneous transitions of two or more separated spins, are known to produce images that are highly sensitive to subvoxel structure, particularly local anisotropy. Here we demonstrate how iDQCs signal can be used to efficiently detect the anis...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21925

    authors: Branca RT,Chen YM,Mouraviev V,Galiana G,Jenista ER,Kumar C,Leuschner C,Warren WS

    更新日期:2009-04-01 00:00:00

  • A variability study of regional alveolar oxygen tension measurement in humans using hyperpolarized (3) He MRI.

    abstract:PURPOSE:A systematic study of the short-term and long-term variability of regional alveolar partial pressure of oxygen tension (pA O2 ) measurements using (3) He magnetic resonance imaging was presented. Additionally, the repeatability of the average evaluated pA O2 was compared with that of the standard pulmonary func...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24604

    authors: Hamedani H,Kadlecek SJ,Ishii M,Emami K,Kuzma NN,Xin Y,Rossman M,Rizi RR

    更新日期:2013-12-01 00:00:00

  • A Bayesian approach for 4D flow imaging of aortic valve in a single breath-hold.

    abstract:PURPOSE:To develop and validate a data processing technique that allows phase-contrast MRI-based 4D flow imaging of the aortic valve in a single breath-hold. THEORY AND METHODS:To regularize the ill-posed inverse problem, we extend a recently proposed 2D phase-contrast MRI method to 4D flow imaging. Adopting an empiri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27386

    authors: Rich A,Potter LC,Jin N,Liu Y,Simonetti OP,Ahmad R

    更新日期:2019-02-01 00:00:00

  • Molecular imaging of angiogenic therapy in peripheral vascular disease with alphanubeta3-integrin-targeted nanoparticles.

    abstract::Noninvasive molecular imaging of angiogenesis could play a critical role in the clinical management of peripheral vascular disease patients. The alpha(nu)beta(3)-integrin, a well-established biomarker of neovascular proliferation, is an ideal target for molecular imaging of angiogenesis. This study investigates whethe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22447

    authors: Winter PM,Caruthers SD,Allen JS,Cai K,Williams TA,Lanza GM,Wickline SA

    更新日期:2010-08-01 00:00:00