A variability study of regional alveolar oxygen tension measurement in humans using hyperpolarized (3) He MRI.

Abstract:

PURPOSE:A systematic study of the short-term and long-term variability of regional alveolar partial pressure of oxygen tension (pA O2 ) measurements using (3) He magnetic resonance imaging was presented. Additionally, the repeatability of the average evaluated pA O2 was compared with that of the standard pulmonary function tests. METHODS:Pulmonary function test and pA O2 imaging were performed on 4 nonsmokers (1 M, 3 F, 56 ± 1.7 years) and 4 smokers (3 M, 1 F, 52 ± 7.5 years) during three visits over the course of 2 weeks. Two measurements were performed per visit. Variability of pA O2 was assessed using a mixed-effect model, with an intraclass correlation coefficient calculated for each group. The coefficient of variation of pA O2 over the 3-day period was also compared with the coefficient of variation of pulmonary function test results. RESULTS:Short-term regional variability based on intraclass correlation coefficient was 0.71 for nonsmokers, and 0.63 for smokers, with long-term variability significantly lower at 0.59 and 0.47, respectively. While the coefficient of variation of the average pA O2 was similar to the repeatability of the diffusing capacity of CO, it was significantly higher than that of Forced Vital Capacity (P = 0.02). CONCLUSION:Short-term and long-term pA O2 variability differences were used as an indication of true physiological changes in order to measure technical reproducibility. Smokers show higher physiologic variability and less technical reproducibility. The suggested pA O2 -imaging technique showed a reasonable regional repeatability in nonsmokers as well as the ability to detect differences between the two groups with similar reproducibility and superior discriminatory ability when compared with pulmonary function tests.

journal_name

Magn Reson Med

authors

Hamedani H,Kadlecek SJ,Ishii M,Emami K,Kuzma NN,Xin Y,Rossman M,Rizi RR

doi

10.1002/mrm.24604

subject

Has Abstract

pub_date

2013-12-01 00:00:00

pages

1557-66

issue

6

eissn

0740-3194

issn

1522-2594

journal_volume

70

pub_type

杂志文章
  • In vivo visualization of myelin water in brain by magnetic resonance.

    abstract::We exploit the intrinsic difference in magnetic resonance spin-spin relaxation time, T2, between water associated with myelin sheaths and water in other central nervous system tissue in order to measure myelin water content within any region of an image or to generate indirectly a myelin map of the brain. In normal vo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310614

    authors: MacKay A,Whittall K,Adler J,Li D,Paty D,Graeb D

    更新日期:1994-06-01 00:00:00

  • Measurements of human cerebral GABA at 4.1 T using numerically optimized editing pulses.

    abstract::The goal of this work was to develop and evaluate a numerically optimized inversion pulse to be used with a homonuclear editing sequence to measure human cerebral GABA in vivo at 4.1 T in the occipital lobe. The optimized pulse was constructed using pallindromic symmetry with 30 pulses and 29 delays. The optimized pul...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390103

    authors: Hetherington HP,Newcomer BR,Pan JW

    更新日期:1998-01-01 00:00:00

  • In vivo multiple-mouse MRI at 7 Tesla.

    abstract::We developed a live high-field multiple-mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfitted with multiple transmit and ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20683

    authors: Bock NA,Nieman BJ,Bishop JB,Mark Henkelman R

    更新日期:2005-11-01 00:00:00

  • Spiral trajectory design: a flexible numerical algorithm and base analytical equations.

    abstract:PURPOSE:Spiral-based trajectories for magnetic resonance imaging can be advantageous, but are often cumbersome to design or create. This work presents a flexible numerical algorithm for designing trajectories based on explicit definition of radial undersampling, and also gives several analytical expressions for charact...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24675

    authors: Pipe JG,Zwart NR

    更新日期:2014-01-01 00:00:00

  • Positive contrast visualization of iron oxide-labeled stem cells using inversion-recovery with ON-resonant water suppression (IRON).

    abstract::In proton magnetic resonance imaging (MRI) metallic substances lead to magnetic field distortions that often result in signal voids in the adjacent anatomic structures. Thus, metallic objects and superparamagnetic iron oxide (SPIO)-labeled cells appear as hypointense artifacts that obscure the underlying anatomy. The ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21399

    authors: Stuber M,Gilson WD,Schär M,Kedziorek DA,Hofmann LV,Shah S,Vonken EJ,Bulte JW,Kraitchman DL

    更新日期:2007-11-01 00:00:00

  • The phenomenon of separate intra- and extracellular resonances of difluorophosphate in 31P and 19F NMR spectra of erythrocytes.

    abstract::Trifluoroacetate and trifluoroacetamide, when added to a suspension of human red blood cells, give rise to separate 19F NMR signals from the intra- and extracellular species. This phenomenon has recently been exploited for measuring the membrane potential of erythrocytes. However, the separation of the peaks was incor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910180119

    authors: Xu AS,Potts JR,Kuchel PW

    更新日期:1991-03-01 00:00:00

  • "PINOT": time-resolved parallel magnetic resonance imaging with a reduced dynamic field of view.

    abstract::This article introduces a novel method named "Parallel Imaging and Noquist in Tandem" (PINOT) for accelerated image acquisition of cine cardiac magnetic resonance imaging. This method combines two prior information formalisms, the SPACE-RIP implementation of parallel imaging and the Noquist method for reduced-data ima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22696

    authors: Hamilton LH,Fabregat JA,Moratal D,Ramamurthy S,Lerakis S,Parks WJ,Sallee D 3rd,Brummer ME

    更新日期:2011-04-01 00:00:00

  • Toward fully automatic estimation of in vivo 31P spectra.

    abstract::Fitting a model to an experimental spectrum is a difficult nonlinear estimation problem. The solution presented here is to start an iterative search procedure sufficiently close to the optimal model parameter set. This is achieved by providing tissue-dependent a priori peak information and by a novel correlation metho...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910210206

    authors: Burger C,McKinnon G,Buchli R,Boesiger P

    更新日期:1991-10-01 00:00:00

  • Quantitative susceptibility mapping using single-shot echo-planar imaging.

    abstract:PURPOSE:To perform quantitative susceptibility mapping (QSM) in negligible acquisition time and apply it to measuring iron-rich subcortical gray matter. METHODS:Whole brain QSM was performed using single-shot gradient echo-planar imaging (EPI) in under 7 seconds on a standard 1.5 T system for imaging brain iron in sub...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25316

    authors: Sun H,Wilman AH

    更新日期:2015-05-01 00:00:00

  • Coronary MR angiography using image-based respiratory motion compensation with inline correction and fixed gating efficiency.

    abstract:PURPOSE:The purpose of this study was to evaluate a new inline motion compensation approach called image-based navigation with Constant Respiratory efficiency UsIng Single End-expiratory threshold (iNAV-CRUISE) for coronary MR angiography (CMRA). METHODS:The CRUISE gating technique was combined with iNAV motion correc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26678

    authors: Henningsson M,Smink J,van Ensbergen G,Botnar R

    更新日期:2018-01-01 00:00:00

  • In vitro 1H NMR "mapping" of human intervertebral discs.

    abstract::Human intervertebral discs were investigated by 1H NMR in vitro. The measured parameters of samples differently located in discs give the "maps" of discs. The spin-lattice relaxation-time maps show similar structure to dry matter and bound water maps, which might mean the future possibility to detect certain disc proc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030122

    authors: Furó I,Bobest M,Pócsik I,Tompa K

    更新日期:1986-02-01 00:00:00

  • Measurement of myocardial frequency offsets during first pass of a gadolinium-based contrast agent in perfusion studies.

    abstract::MRI of myocardial perfusion observed with an extracellular contrast agent has proven valuable for the detection of coronary artery disease. During contrast enhancement transient dark rim artifacts are sometimes visible, complicating diagnosis and quantification. In this work a quantification of the frequency offsets c...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.21723

    authors: Ferreira P,Gatehouse P,Bucciarelli-Ducci C,Wage R,Firmin D

    更新日期:2008-10-01 00:00:00

  • Phase-cycled simultaneous multislice balanced SSFP imaging with CAIPIRINHA for efficient banding reduction.

    abstract:PURPOSE:To present a time-efficient technique for banding reduction in balanced steady-state free precession (bSSFP) imaging using phase-cycled simultaneous multislice (SMS) acquisition with CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration). THEORY:The proposed technique exploits the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26076

    authors: Wang Y,Shao X,Martin T,Moeller S,Yacoub E,Wang DJ

    更新日期:2016-12-01 00:00:00

  • Flexible and efficient optimization of quantitative sequences using automatic differentiation of Bloch simulations.

    abstract:PURPOSE:To investigate a computationally efficient method for optimizing the Cramér-Rao Lower Bound (CRLB) of quantitative sequences without using approximations or an analytical expression of the signal. METHODS:Automatic differentiation was applied to Bloch simulations and used to optimize several quantitative seque...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27832

    authors: Lee PK,Watkins LE,Anderson TI,Buonincontri G,Hargreaves BA

    更新日期:2019-10-01 00:00:00

  • Localized proton MR spectroscopy of the human kidney in vivo by means of short echo time STEAM sequences.

    abstract::In order to obtain proton magnetic resonance spectra from the normal human kidney in vivo, we employed a STEAM sequence with delay times TE = 10 ms and TM = 30 ms. Signals are attenuated during STEAM sequences by J-coupling effects and by macroscopic movement of the sample. The combination of short echo times and resp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310503

    authors: Dixon RM,Frahm J

    更新日期:1994-05-01 00:00:00

  • Estimating T1 from multichannel variable flip angle SPGR sequences.

    abstract::Quantitative estimation of T1 is a challenging but important task inherent to many clinical applications. The most commonly used paradigm for estimating T1 in vivo involves performing a sequence of spoiled gradient-recalled echo acquisitions at different flip angles, followed by fitting of an exponential model to the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24401

    authors: Trzasko JD,Mostardi PM,Riederer SJ,Manduca A

    更新日期:2013-06-01 00:00:00

  • A flexible fast spin echo triple-echo Dixon technique.

    abstract:PURPOSE:To develop a flexible fast spin echo (FSE) triple-echo Dixon (FTED) technique. METHODS:An FSE pulse sequence was modified by replacing each readout gradient with three fast-switching bipolar readout gradients with minimal interecho dead time. The corresponding three echoes were used to generate three raw image...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26186

    authors: Son JB,Hwang KP,Madewell JE,Bayram E,Hazle JD,Low RN,Ma J

    更新日期:2017-03-01 00:00:00

  • NMR visibility studies of N-delta proton of proximal histidine in deoxyhemoglobin in lysed and intact red cells.

    abstract::Recent in vivo 1H MRS studies of muscle oxygen levels by means of myoglobin (Mb) oxygenation have necessitated an investigation of the possible contamination from deoxy-hemoglobin (Hb). To determine the contribution of Hb in these NMR measurements, we studied the NMR visibility of histidyl N-delta proton of Hb in lyse...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300616

    authors: Wang DJ,Nioka S,Wang Z,Leigh JS,Chance B

    更新日期:1993-12-01 00:00:00

  • Multifrequency selective rf pulses for multislice MR imaging.

    abstract::A method is described for multislice imaging by means of rf pulses which contain a multifrequency excitation spectrum. These pulses label each slice by an individual signal phase and allow the separation of the signals from all the slices by subsequent add/subtract procedures. The image sensitivity corresponds to the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060315

    authors: Müller S

    更新日期:1988-03-01 00:00:00

  • Evidence for a contribution of paramagnetic ions to water proton spin-lattice relaxation in normal and malignant mouse tissues.

    abstract::Paramagnetic ions complexed to proteins may lose, retain, or enhance solvent paramagnetic relaxation (SPR) relative to free solution. We measured T1 and T2 of three mouse cancers, their normal counterparts, and six additional tissues. Long T1 of cancers was not caused by necrosis or by different contents of water, fat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910180204

    authors: Negendank W,Corbett T,Crowley M,Kellogg C

    更新日期:1991-04-01 00:00:00

  • Whole-body continuously moving table fat-water MRI with dynamic B0 shimming at 3 Tesla.

    abstract:PURPOSE:The purpose of this work was to develop a rapid and robust whole-body fat-water MRI (FWMRI) method using a continuously moving table (CMT) with dynamic field corrections at 3 Tesla. METHODS:CMT FWMRI was developed at 3 Tesla with a multiecho golden angle (GA) radial trajectory and dynamic B0 field shimming. Wh...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25848

    authors: Sengupta S,Smith DS,Gifford A,Welch EB

    更新日期:2016-07-01 00:00:00

  • Anisotropic and restricted diffusion of water in the sciatic nerve: A (2)H double-quantum-filtered NMR study.

    abstract::The signals of water in the different compartments of rat sciatic nerve are resolved in the (2)H double-quantum-filtered NMR spectrum, due to their different quadrupolar splittings and relaxation rates. This resolution allowed the independent measurement of the water diffusion coefficients in the different compartment...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199909)42:3<461::aid-mrm8>

    authors: Seo Y,Shinar H,Morita Y,Navon G

    更新日期:1999-09-01 00:00:00

  • Morphological and carbogen-based functional MRI of a chemically induced liver tumor model in mice.

    abstract::A multifocal mouse liver tumor model chemically induced with 5,9-dimethyl-7H-dibenzo[c,g]carbazole was investigated by respiratory-triggered morphological and functional MRI (fMRI) at 4.7 Tesla. The model is characterized by the presence of two tumor types: hypovascular cholangioma and vascularized hepatocellular carc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10555

    authors: Thomas CD,Chenu E,Walczak C,Plessis MJ,Perin F,Volk A

    更新日期:2003-09-01 00:00:00

  • Resolution-recovery for EPR imaging of free radical molecules in mice.

    abstract::A method of post-processing to enhance the image resolution of the distribution of free radical molecules obtained with continuous-wave electron paramagnetic resonance (CW-EPR) imaging is reported. The low spatial resolution of EPR imaging, which has created difficulties in biomedical applications, was overcome by the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22029

    authors: Ikebata Y,Sato-Akaba H,Aoyama T,Fujii H,Itoh K,Hirata H

    更新日期:2009-09-01 00:00:00

  • Statistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise.

    abstract::This work helps elucidate how background noise introduces statistical artifacts in the distribution of the sorted eigenvalues and eigenvectors in diffusion tensor MRI (DT-MRI) data. Although it was known that sorting eigenvalues (principal diffusivities) by magnitude introduces a bias in their sample mean within a hom...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200007)44:1<41::aid-mrm8>3.0.co;

    authors: Basser PJ,Pajevic S

    更新日期:2000-07-01 00:00:00

  • Machine learning RF shimming: Prediction by iteratively projected ridge regression.

    abstract:PURPOSE:To obviate online slice-by-slice RF shim optimization and reduce B1+ mapping requirements for patient-specific RF shimming in high-field magnetic resonance imaging. THEORY AND METHODS:RF Shim Prediction by Iteratively Projected Ridge Regression (PIPRR) predicts patient-specific, SAR-efficient RF shims with a m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27192

    authors: Ianni JD,Cao Z,Grissom WA

    更新日期:2018-11-01 00:00:00

  • Orientational dependence of T2 relaxation in articular cartilage: A microscopic MRI (microMRI) study.

    abstract::The experiments reported herein are the first MRI investigations of the orientational dependence of T(2) relaxation in articular cartilage at microscopic resolution over the 360 degrees angular space. For each of six canine cartilage specimens, 48 independent T(2)-weighted proton images were acquired for 12 different ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10216

    authors: Xia Y,Moody JB,Alhadlaq H

    更新日期:2002-09-01 00:00:00

  • Hormonally induced modulation in the phosphate metabolites of breast cancer: analysis of in vivo 31P MRS signals with a modified prony method.

    abstract::A modified Prony method (MPM) was applied to analyze the main signals present in spatially resolved 31P NMR spectra of MCF7 breast tumors implanted in nude mice. First, the method was tested on synthetic data to establish its limits of reliability. Its performance with respect to peak identification and quantification...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380219

    authors: Viti V,Ragona R,Guidoni L,Barone P,Furman E,Degani H

    更新日期:1997-08-01 00:00:00

  • Single-shot, three-dimensional "non-echo" localization method for in vivo NMR spectroscopy.

    abstract::Metabolite signals with short T(1) or T(2) are difficult to localize with full sensitivity. This limitation was overcome with the development and implementation of a single-shot, complete three-dimensional "non-echo" localization method with reduced sensitivity to spatial B(1) variation, which is suitable for measurin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200009)44:3<387::aid-mrm8>3.0.co

    authors: Choi IY,Tkác I,Gruetter R

    更新日期:2000-09-01 00:00:00

  • Electromagnetic fields of surface coil in vivo NMR at high frequencies.

    abstract::A high frequency solution of the electromagnetic field produced by a circular surface coil adjacent to a homogeneous conducting, dielectric sphere is used to predict the attainable signal to noise ratio (S/N) and specific absorption rate (SAR) for in vivo 1H NMR spectroscopy experiments from 200 to 430 MHz (4.7-10 T)....

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910220254

    authors: Keltner JR,Carlson JW,Roos MS,Wong ST,Wong TL,Budinger TF

    更新日期:1991-12-01 00:00:00