Coronary MR angiography using image-based respiratory motion compensation with inline correction and fixed gating efficiency.

Abstract:

PURPOSE:The purpose of this study was to evaluate a new inline motion compensation approach called image-based navigation with Constant Respiratory efficiency UsIng Single End-expiratory threshold (iNAV-CRUISE) for coronary MR angiography (CMRA). METHODS:The CRUISE gating technique was combined with iNAV motion correction and implemented inline for motion-compensated CMRA on a 1.5 Tesla scanner. The approach was compared to conventional diaphragmatic navigator gating (dNAVG) in 10 healthy subjects. The CMRA images were compared for vessel sharpness and visual score of the right coronary artery (RCA), left anterior descending artery (LAD), left circumflex, and scan time. RESULTS:The scan time was similar between the methods (dNAVG : 6:32 ± 1:09 vs. iNAV-CRUISE: 6:58 ± 0:17, P = not significant). However, the vessel sharpness of the RCA (dNAVG : 60.2 ± 10.1 vs. iNAV-CRUISE: 71.8 ± 8.9, P = 0.001) and LAD (dNAVG : 58.0 ± 8.0 vs. iNAV-CRUISE: 67.4 ± 7.1, P = 0.008) were significantly improved using iNAV-CRUISE. The visual score of the RCA was higher using iNAV-CRUISE compared to dNAVG (dNAVG : 3,4,3 vs. iNAV-CRUISE: 4,4,3, P < 0.01). CONCLUSION:The iNAV-CRUISE approach out-performs the conventional respiratory motion compensation technique in healthy subjects. Although scan time was comparable, the image quality was improved using iNAV-CRUISE. Magn Reson Med 79:416-422, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

journal_name

Magn Reson Med

authors

Henningsson M,Smink J,van Ensbergen G,Botnar R

doi

10.1002/mrm.26678

subject

Has Abstract

pub_date

2018-01-01 00:00:00

pages

416-422

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

79

pub_type

杂志文章
  • Simulations of high permittivity materials for 7 T neuroimaging and evaluation of a new barium titanate-based dielectric.

    abstract::High permittivity "dielectric pads" have been shown to increase image quality at high magnetic fields in regions of low radiofrequency transmit efficiency. This article presents a series of electromagnetic simulations to determine the effects of pad size and geometry, relative permittivity value, as well as thickness ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24176

    authors: Teeuwisse WM,Brink WM,Haines KN,Webb AG

    更新日期:2012-04-01 00:00:00

  • Efficient sample density estimation by combining gridding and an optimized kernel.

    abstract::The reconstruction of non-Cartesian k-space trajectories often requires the estimation of nonuniform sampling density. Particularly for 3D, this calculation can be computationally expensive. The method proposed in this work combines an iterative algorithm previously proposed by Pipe and Menon (Magn Reson Med 1999;41:1...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23041

    authors: Zwart NR,Johnson KO,Pipe JG

    更新日期:2012-03-01 00:00:00

  • Analysis and correction of biases in cross-relaxation MRI due to biexponential longitudinal relaxation.

    abstract:PURPOSE:Cross-relaxation imaging (CRI) is a family of quantitative magnetization transfer techniques that utilize images obtained with off-resonance saturation and longitudinal relaxation rate (R1) maps reconstructed by the variable flip angle (VFA) method. It was demonstrated recently that a significant bias in an app...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24677

    authors: Mossahebi P,Yarnykh VL,Samsonov A

    更新日期:2014-02-01 00:00:00

  • Modification of embolic-PVA particles with MR contrast agents.

    abstract::We report the synthesis and characterization of polyvinyl alcohol (PVA) embolic particles modified with a clinically approved magnetic resonance (MR) contrast agent. PVA particles are used during transcatheter arterial embolization (TAE) procedures and this minimally invasive technique is a widely employed treatment f...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21518

    authors: Cilliers R,Song Y,Kohlmeir EK,Larson AC,Omary RA,Meade TJ

    更新日期:2008-04-01 00:00:00

  • Motion correction in fMRI via registration of individual slices into an anatomical volume.

    abstract::An automated retrospective image registration based on mutual information is adapted to a multislice functional magnetic resonance imaging (fMRI) acquisition protocol to provide accurate motion correction. Motion correction is performed by mapping each slice to an anatomic volume data set acquired in the same fMRI ses...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199905)41:5<964::aid-mrm16

    authors: Kim B,Boes JL,Bland PH,Chenevert TL,Meyer CR

    更新日期:1999-05-01 00:00:00

  • Cerebrospinal fluid-suppressed high-resolution diffusion imaging of human brain.

    abstract::A cerebrospinal fluid (CSF)-suppressed flow-attenuated inversion recovery (FLAIR) double-shot diffusion echo-planar imaging (EPI) sequence was developed and used, along with a non-CSF-suppressed version of the sequence, to determine the extent of the contribution of CSF partial-volume averaging to the apparent diffusi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370117

    authors: Falconer JC,Narayana PA

    更新日期:1997-01-01 00:00:00

  • CEST MRI quantification procedures for breast cancer treatment-related lymphedema therapy evaluation.

    abstract:PURPOSE:To quantify chemical exchange saturation transfer contrast in upper extremities of participants with lymphedema before and after standardized lymphatic mobilization therapy using correction procedures for B0 and B1 heterogeneity, and T1 relaxation. METHODS:Females with (n = 12) and without (n = 17) breast canc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28031

    authors: Crescenzi R,Donahue PMC,Mahany H,Lants SK,Donahue MJ

    更新日期:2020-05-01 00:00:00

  • Magnetic susceptibility measurement of insoluble solids by NMR: magnetic susceptibility of bone.

    abstract::Measurements of the volume magnetic susceptibility of solids using the classical Gouy balance approach are hampered by variations in apparent density of the packed powder. In this paper a quantitative NMR measurement of the volume magnetic susceptibility of powdered solids is described and the volume susceptibility of...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370404

    authors: Hopkins JA,Wehrli FW

    更新日期:1997-04-01 00:00:00

  • Modulation of the pharmacokinetics of macromolecular contrast material by avidin chase: MRI, optical, and inductively coupled plasma mass spectrometry tracking of triply labeled albumin.

    abstract::The goal of this work was to develop an MRI method for mapping the clearance of interstitial macromolecular plasma proteins after their extravasation from permeable blood vessels. To that end, a well-defined window of exposure to elevated blood levels was generated by inducing rapid clearance of macromolecular contras...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10638

    authors: Dafni H,Gilead A,Nevo N,Eilam R,Harmelin A,Neeman M

    更新日期:2003-11-01 00:00:00

  • Automatic vessel removal in gliomas from dynamic susceptibility contrast imaging.

    abstract::The presence of macroscopic vessels within the tumor region is a potential confounding factor in MR-based dynamic susceptibility contrast (DSC)-enhanced glioma grading. In order to distinguish between such vessels and the elevated cerebral blood volume (CBV) of brain tumors, we propose a vessel segmentation technique ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21944

    authors: Emblem KE,Due-Tonnessen P,Hald JK,Bjornerud A

    更新日期:2009-05-01 00:00:00

  • Quantification of punctate iron sources using magnetic resonance phase.

    abstract::Iron-mediated tissue damage is present in cerebrovascular and neurodegenerative diseases and neurotrauma. Brain microbleeds are often present in these maladies and are assuming increasing clinical importance. Because brain microbleeds present a source of pathologic iron to the brain, the noninvasive quantification of ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22185

    authors: McAuley G,Schrag M,Sipos P,Sun SW,Obenaus A,Neelavalli J,Haacke EM,Holshouser B,Madácsi R,Kirsch W

    更新日期:2010-01-01 00:00:00

  • NMR investigation of hydroxyethyl starch-induced aggregation of human erythrocytes.

    abstract::Aggregation of human erythrocytes at physiological hematocrit by hydroxyethyl starch (HES) was investigated with a 1H nuclear magnetic resonance method which measures the erythrocyte mean water exchange time, tau a. A relationship that takes into account the effect of the aggregate as the water-exchanging unit was use...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050108

    authors: Caines GH,Goldstein JH

    更新日期:1987-07-01 00:00:00

  • Common k-space acquisition: a method to improve myocardial grid-tag contrast.

    abstract::A current limitation of many myocardial tag acquisitions employing SPAMM encoding is the relatively rapid loss of tag contrast over the cardiac cycle. Acquisition schemes that apply line tags produce prolonged tag contrast compared with directly excited grid tags. However, a grid-tag series can be generated by combini...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370519

    authors: Doyle M,Walsh EG,Foster RE,Pohost GM

    更新日期:1997-05-01 00:00:00

  • The effect of realistic geometries on the susceptibility-weighted MR signal in white matter.

    abstract:PURPOSE:To investigate the effect of realistic microstructural geometry on the susceptibility-weighted MR signal in white matter (WM), with application to demyelination. METHODS:Previous work has modeled susceptibility-weighted signals under the assumption that axons are cylindrical. In this study, we explored the imp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26689

    authors: Xu T,Foxley S,Kleinnijenhuis M,Chen WC,Miller KL

    更新日期:2018-01-01 00:00:00

  • Time-domain combination of MR spectroscopy data acquired using phased-array coils.

    abstract::A new method for efficiently processing MRS data acquired with phased-array coils is presented. The method consists of performing phase compensation (i.e., redefining the signal phase relative to a common reference) of the signals in the time domain prior to combining the signals. The resulting spectra are equivalent ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20244

    authors: Brown MA

    更新日期:2004-11-01 00:00:00

  • Simultaneous spin-echo refocusing.

    abstract::A new approach to spin-echo imaging is presented in which the 180 degrees RF pulse refocuses two or more spin-echoes at different positions in the readout period. When simultaneous echo refocusing (SER) is implemented using multiple 180 degrees pulses, an undesirable mixing of stimulated echoes and primary echoes from...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20587

    authors: Günther M,Feinberg DA

    更新日期:2005-09-01 00:00:00

  • Diffusion imaging of the spinal cord in vivo: estimation of the principal diffusivities and application to multiple sclerosis.

    abstract::Magnetic resonance (MR) diffusion imaging is a useful technique with which to increase our understanding of pathologic damage to the central nervous system. To fully quantitate diffusion and anisotropy in the spinal cord, as in other tissues, it is necessary to determine the diffusion tensor. If spinal cord diffusion ...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/(sici)1522-2594(200001)43:1<133::aid-mrm16

    authors: Clark CA,Werring DJ,Miller DH

    更新日期:2000-01-01 00:00:00

  • Effect of lanthanide ions on dynamic nuclear polarization enhancement and liquid-state T1 relaxation.

    abstract::In the dynamic nuclear polarization process, microwave irradiation facilitates exchange of polarization from a radical's unpaired electron to nuclear spins at cryogenic temperatures, increasing polarization by >10,000. Doping samples with Gd(3+) ions further increases the achievable solid-state polarization. However, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24207

    authors: Gordon JW,Fain SB,Rowland IJ

    更新日期:2012-12-01 00:00:00

  • Q-space truncation and sampling in diffusion spectrum imaging.

    abstract:PURPOSE:To characterize the q-space truncation and sampling on the spin-displacement probability density function (PDF) in diffusion spectrum imaging (DSI). METHODS:DSI data were acquired using the MGH-USC connectome scanner (Gmax  = 300 mT/m) with bmax  = 30,000 s/mm2 , 17 × 17 × 17, 15 × 15 × 15 and 11 × 11 × 11 gri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26071

    authors: Tian Q,Rokem A,Folkerth RD,Nummenmaa A,Fan Q,Edlow BL,McNab JA

    更新日期:2016-12-01 00:00:00

  • Orientational dependence of T2 relaxation in articular cartilage: A microscopic MRI (microMRI) study.

    abstract::The experiments reported herein are the first MRI investigations of the orientational dependence of T(2) relaxation in articular cartilage at microscopic resolution over the 360 degrees angular space. For each of six canine cartilage specimens, 48 independent T(2)-weighted proton images were acquired for 12 different ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10216

    authors: Xia Y,Moody JB,Alhadlaq H

    更新日期:2002-09-01 00:00:00

  • Dynamic changes in water ADC, energy metabolism, extracellular space volume, and tortuosity in neonatal rat brain during global ischemia.

    abstract::To obtain a better understanding of the mechanisms underlying early changes in the brain water apparent diffusion coefficient (ADC) observed in cerebral ischemia, dynamic changes in the ADC of water and in the energy status were measured at postnatal day 8 or 9 in neonatal rat brains after cardiac arrest using 1H MRS/...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360110

    authors: van der Toorn A,Syková E,Dijkhuizen RM,Vorísek I,Vargová L,Skobisová E,van Lookeren Campagne M,Reese T,Nicolay K

    更新日期:1996-07-01 00:00:00

  • Multi-band MR fingerprinting (MRF) ASL imaging using artificial-neural-network trained with high-fidelity experimental data.

    abstract:PURPOSE:We aim to leverage the power of deep-learning with high-fidelity training data to improve the reliability and processing speed of hemodynamic mapping with MR fingerprinting (MRF) arterial spin labeling (ASL). METHODS:A total of 15 healthy subjects were studied on a 3T MRI. Each subject underwent 10 runs of a m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28560

    authors: Fan H,Su P,Huang J,Liu P,Lu H

    更新日期:2021-04-01 00:00:00

  • x-f Choice: reconstruction of undersampled dynamic MRI by data-driven alias rejection applied to contrast-enhanced angiography.

    abstract::A technique for reconstructing dynamic undersampled MRI data, termed "x-f choice," was developed and applied to dynamic contrast-enhanced MR angiography (DCE-MRA). Regular undersampling in k-t space (a hybrid of k-space and time) creates aliasing in the conjugate x-f space that must be resolved. When regions in the ob...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21008

    authors: Malik SJ,Schmitz S,O'Regan D,Larkman DJ,Hajnal JV

    更新日期:2006-10-01 00:00:00

  • Automatic selection of mask and arterial phase images for temporally resolved MR digital subtraction angiography.

    abstract::For time-resolved background-subtracted contrast-enhanced magnetic resonance angiography, the bright and sparse arterial signal allows unique identification of contrast bolus arrival in the arteries. This article presents an automatic filtering algorithm using such arterial characterization for selecting arterial phas...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10358

    authors: Kim J,Prince MR,Zabih R,Bezanson J,Watts R,Erel HE,Wang Y

    更新日期:2002-12-01 00:00:00

  • A molecular theory of relaxation and magnetization transfer: application to cross-linked BSA, a model for tissue.

    abstract::Homogeneous soft tissue, as regards its magnetic relaxation properties, is well-modeled by solutions of cross-linked protein (see Koenig and Brown, Prog. NMR Spectr. 22, 487 (1991)). Interactions at the solute-solvent interface alter the hydrodynamics of solvent water, and also couple the solute and solvent proton Zee...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300606

    authors: Koenig SH,Brown RD 3rd

    更新日期:1993-12-01 00:00:00

  • Metabolite 1H relaxation in normal and hyponatremic brain.

    abstract::Proton spin relaxation rate constants in normal and hyponatremic rat brain were measured to determine the sensitivity of metabolite relaxation properties to cytotoxic edema and to quantify metabolite concentration in normal and edematous brain. Relaxation rate constants for protons of water and spectral regions with d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350510

    authors: Rooney WD,Ebisu T,Mancuso A,Graham S,Weiner MW,Maudsley AA

    更新日期:1996-05-01 00:00:00

  • Shielded-coaxial-cable coils as receive and transceive array elements for 7T human MRI.

    abstract:PURPOSE:To investigate the use of shielded-coaxial-cable (SCC) coils as elements for multi-channel receive-only and transceive arrays for 7T human MRI and to compare their performance with equivalently sized conventional loop coils. METHODS:The SCC coil element consists of a coaxial loop with interrupted central condu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27964

    authors: Ruytenberg T,Webb A,Zivkovic I

    更新日期:2020-03-01 00:00:00

  • Sources of functional apparent diffusion coefficient changes investigated by diffusion-weighted spin-echo fMRI.

    abstract::The mechanism behind previously observed changes in the apparent diffusion coefficient (ADC) during brain activation is not well understood. Therefore, we investigated the signal source and spatial specificity of functional magnetic resonance imaging (fMRI) ADC changes systematically in the visual cortex of cats using...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21074

    authors: Jin T,Zhao F,Kim SG

    更新日期:2006-12-01 00:00:00

  • Measurement of cerebrospinal fluid oxygen partial pressure in humans using MRI.

    abstract::Fluid-attenuated inversion recovery (FLAIR) images obtained during the administration of supplemental oxygen demonstrate a hyperintense signal within the cerebrospinal fluid (CSF) that is likely caused by T1 changes induced by paramagnetic molecular oxygen. Previous studies demonstrated a linear relationship between t...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20546

    authors: Zaharchuk G,Martin AJ,Rosenthal G,Manley GT,Dillon WP

    更新日期:2005-07-01 00:00:00

  • Systematic analysis of the intravoxel incoherent motion threshold separating perfusion and diffusion effects: Proposal of a standardized algorithm.

    abstract:PURPOSE:To systematically evaluate the dependence of intravoxel-incoherent-motion (IVIM) parameters on the b-value threshold separating the perfusion and diffusion compartment, and to implement and test an algorithm for the standardized computation of this threshold. METHODS:Diffusion weighted images of the upper abdo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25506

    authors: Wurnig MC,Donati OF,Ulbrich E,Filli L,Kenkel D,Thoeny HC,Boss A

    更新日期:2015-11-01 00:00:00