Abstract:
PURPOSE:To propose a phase error correction scheme for monopolar time-interleaved multi-echo gradient echo water-fat imaging that allows accurate and robust complex-based quantification of the proton density fat fraction (PDFF). METHODS:A three-step phase correction scheme is proposed to address a) a phase term induced by echo misalignments that can be measured with a reference scan using reversed readout polarity, b) a phase term induced by the concomitant gradient field that can be predicted from the gradient waveforms, and c) a phase offset between time-interleaved echo trains. Simulations were carried out to characterize the concomitant gradient field-induced PDFF bias and the performance estimating the phase offset between time-interleaved echo trains. Phantom experiments and in vivo liver and thigh imaging were performed to study the relevance of each of the three phase correction steps on PDFF accuracy and robustness. RESULTS:The simulation, phantom, and in vivo results showed in agreement with the theory an echo time-dependent PDFF bias introduced by the three phase error sources. The proposed phase correction scheme was found to provide accurate PDFF estimation independent of the employed echo time combination. CONCLUSION:Complex-based time-interleaved water-fat imaging was found to give accurate and robust PDFF measurements after applying the proposed phase error correction scheme. Magn Reson Med 78:984-996, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Ruschke S,Eggers H,Kooijman H,Diefenbach MN,Baum T,Haase A,Rummeny EJ,Hu HH,Karampinos DCdoi
10.1002/mrm.26485subject
Has Abstractpub_date
2017-09-01 00:00:00pages
984-996issue
3eissn
0740-3194issn
1522-2594journal_volume
78pub_type
杂志文章abstract:PURPOSE:To develop a novel, simultaneous multislice reconstruction method that exploits Hankel subspace learning (SMS-HSL) for aliasing separation in the slice direction. METHODS:An SMS signal model with the Hankel-structured matrix was proposed. To efficiently suppress interslice leakage artifacts from a signal subsp...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26527
更新日期:2017-10-01 00:00:00
abstract:PURPOSE:MR elastography (MRE) of the brain is being explored as a biomarker of neurodegenerative disease such as dementia. However, MRE measures for healthy brain have varied widely. Differing wave delivery methodologies may have influenced this, hence finite element-based simulations were performed to explore this pos...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26333
更新日期:2017-07-01 00:00:00
abstract:PURPOSE:To test the feasibility of using the SPICE (SPectroscopic Imaging by exploiting spatiospectral CorrElation) technique, which uses the partial separability of spectroscopic data, for high resolution hyperpolarized (HP) 13 C spectroscopic imaging. METHODS:Numerical simulations were performed to investigate the i...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27061
更新日期:2018-08-01 00:00:00
abstract:PURPOSE:MRI can produce quantitative liver fat fraction (FF) maps noninvasively, which can help to improve diagnoses of fatty liver diseases. However, most sequences acquire several two-dimensional (2D) slices during one or more breath-holds, which may be difficult for patients with limited breath-holding capacity. A w...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26028
更新日期:2016-11-01 00:00:00
abstract:PURPOSE:The correlation between glutamine metabolism and oncogene expression in cancers has led to a renewed interest in the role of glutamine in cancer cell survival. Hyperpolarized [5-(13) C]glutamine is evaluated as a potential biomarker for noninvasive metabolic measurements of drug response in prostate cancer cell...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25360
更新日期:2015-06-01 00:00:00
abstract:PURPOSE:To develop a semiautomatic method for rapid segmentation of myocardial tissue phase mapping (TPM) data. METHODS:Manual segmentation of the myocardium was performed at end-diastole and end-systole. The points in both user-defined masks were then automatically tracked over the entire cardiac cycle using temporal...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26486
更新日期:2017-09-01 00:00:00
abstract::Mumps virus-infected and normal newborn hamster brains were imaged with magnetic resonance (MR) within 24 h after birth and serially scanned. Hydrocephalus developed explosively on Day 6 postinfection and progressed until death occurred soon after Day 10. This study demonstrates the utility of MR in the investigation ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910040611
更新日期:1987-06-01 00:00:00
abstract::Image reconstruction of tagged cardiac MR images using complementary spatial modulation of magnetization (CSPAMM) requires the subtraction of two complex datasets to remove the untagged signal. Although the resultant images typically have sharper and more persistent tags than images formed without complementary taggin...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10523
更新日期:2003-08-01 00:00:00
abstract::For sodium imaging of the human brain, Gibbs' ringing can degrade image appearance and confound image analysis; k-space filtering is generally required. In this work, the signal to noise ratio (SNR) advantage of sampling density weighted apodization (SDWA) over uniform k-space sampling with postacquisition filtering a...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21738
更新日期:2008-10-01 00:00:00
abstract::In numerical analyses of radiofrequency (RF) fields for MRI, RF power is often permitted to radiate out of the problem region. In reality, RF power will be confined by the magnet bore and RF screen enclosing the magnet room. We present numerical calculations at different frequencies for various surface and volume coil...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24244
更新日期:2013-01-01 00:00:00
abstract::In past decades, much effort has been invested in developing therapies for spinal injuries. Lack of standardization of clinical read-out measures, however, makes direct comparison of experimental therapies difficult. Damage and therapeutic effects in vivo are routinely evaluated using rather subjective behavioral test...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20888
更新日期:2006-05-01 00:00:00
abstract::A new method for efficiently processing MRS data acquired with phased-array coils is presented. The method consists of performing phase compensation (i.e., redefining the signal phase relative to a common reference) of the signals in the time domain prior to combining the signals. The resulting spectra are equivalent ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20244
更新日期:2004-11-01 00:00:00
abstract:PURPOSE:In conventional three-dimensional magnetic resonance elastography, motion encoding gradients (MEGs) synchronized to a mechanical excitation are applied separately in each direction to encode tissue displacement generated by the corresponding waves. This requires long acquisition times that introduce errors due ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25280
更新日期:2015-04-01 00:00:00
abstract::Diffusion-weighted single voxel experiments conducted at b-values up to 1 x 10(4) smm-2 yielded biexponential signal attenuation curves for both normal and ischemic brain. The relative fractions of the rapidly and slowly decaying components (f1, f2) are f1 = 0.80 +/- 0.02, f2 = 0.17 +/- 0.02 in healthy adult rat brain...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910360607
更新日期:1996-12-01 00:00:00
abstract::An automatic fMRI protocol for the investigation of the human auditory cortex has been developed. For the activation of the auditory system, the scanner noise itself is the source of sound. Rapid switching of B0 gradients allows the generation of tones of defined frequencies and amplitude on a conventional scanner wit...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910400621
更新日期:1998-12-01 00:00:00
abstract::Some of the important features of how pulsatile flow generates artifacts in three-dimensional magnetic resonance imaging are analyzed and demonstrated. Time variations in the magnetic resonance signal during the heart cycle lead to more complex patterns of artifacts in 3D imaging than in 2D imaging. The appearance and...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910300305
更新日期:1993-09-01 00:00:00
abstract:PURPOSE:To develop a novel technique for voxel-based mapping of lung microstructural parameters using hyperpolarized 129 Xe dissolved-phase MR imaging during saturation recovery. METHODS:A pulse sequence using a highly undersampled stack-of-stars trajectory was developed, and low-rank plus sparse matrix decomposition ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27559
更新日期:2019-04-01 00:00:00
abstract:PURPOSE:Assessing the functionality of muscle fibers is essential to monitor both pathological and physiological processes. Here, we present a new method for accurate, quantitative measurement of muscle contraction with magnetic resonance imaging (MRI) using an electrical muscle stimulator (EMS), hence allowing the dir...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26154
更新日期:2017-02-01 00:00:00
abstract:PURPOSE:Applications of dynamic shimming require high field fidelity, and characterizing the shim field dynamics is therefore necessary. Modeling the system as linear and time-invariant, the purpose of this work was to measure the impulse response function with optimal sensitivity. THEORY AND METHODS:Frequency-swept p...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24934
更新日期:2014-08-01 00:00:00
abstract::Localized 7Li MR point-resolved spectroscopy (PRESS) was developed as a technique to measure lithium (Li) concentration in rat brain in vivo. Localized 7Li spectra could be obtained at 4.7 T in a 0.7-ml voxel in rat brain over the entire therapeutic range of serum Li for humans. Localized 7Li spin-lattice (T1) and spi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20112
更新日期:2004-07-01 00:00:00
abstract::A simple (2)H NMR method for quantifying absolute (2)H-enrichments in all seven aliphatic positions of glucose following its derivatization to monoacetone glucose is presented. The method is based on the addition of a small quantity of (2)H-enriched formate to the NMR sample. When the method was applied to [2-(2)H]mon...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10234
更新日期:2002-09-01 00:00:00
abstract::Manganese-enhanced MRI has previously been used for visualization of brain architecture and functional mapping of neural pathways. The present work investigated the potential of manganese-enhanced MRI for noninvasive imaging of salivary glands in living subjects. Marked shortening of T(1) was observed in salivary glan...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22452
更新日期:2010-09-01 00:00:00
abstract::In an effort to develop MRI methods for the evaluation of tumor angiogenesis (new blood vessel formation), MRI-derived cerebral blood volume (CBV) information has been compared to histologic measures of microvessel density (MVD). Although MVD is a standard marker of angiogenesis, it is not a direct correlate of the vo...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1252
更新日期:2001-10-01 00:00:00
abstract::Multimodal, biocompatible contrast agents for high magnetic field applications represent a new class of nanomaterials with significant potential for tracking of fluorescence and MR in vitro and vivo. Optimized for high-field MR applications-including biomedical imaging at 21.1 T, the highest magnetic field available f...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22441
更新日期:2010-09-01 00:00:00
abstract::The presence of macroscopic vessels within the tumor region is a potential confounding factor in MR-based dynamic susceptibility contrast (DSC)-enhanced glioma grading. In order to distinguish between such vessels and the elevated cerebral blood volume (CBV) of brain tumors, we propose a vessel segmentation technique ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21944
更新日期:2009-05-01 00:00:00
abstract::The purpose of the present study was to examine whether single human carcinoma cells labeled with iron oxide nanoparticles could be detected by magnetic resonance (MR) imaging on a clinical 3-T scanner using a surface coil only. WiDr human colon carcinoma cells were loaded with two kinds of iron oxide nanoparticles di...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20455
更新日期:2005-05-01 00:00:00
abstract::In the present work, diffusion-weighted (DW)-NMR spectroscopy of glutamate was performed during a (13)C-labeled glucose infusion in monkey brain (six experiments). It is shown that glutamate (13)C labeling occurs significantly faster at higher diffusion weightings-slightly for glutamate in position C4, and more marked...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21661
更新日期:2008-08-01 00:00:00
abstract::Variable nutation SSFP (DESPOT2) permits rapid, high-resolution determination of the transverse (T2) relaxation constant. A limitation of DESPOT2, however, is the presence of T2 voids due to off-resonance banding artifacts associated with SSFP images. These artifacts typically occur in images acquired with long repeti...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20159
更新日期:2004-08-01 00:00:00
abstract::Image selected in vivo spectroscopy (ISIS) is a volume selection method often used for in vivo (31)P MRS, since it is suitable for measurements of substances with short T(2). However, ISIS can suffer from significant signal contributions caused by T(1) smearing from regions outside the VOI. A computer model was develo...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/1522-2594(200010)44:4<546::aid-mrm8>3.0.co
更新日期:2000-10-01 00:00:00
abstract::The proton exchange rates between water and the hydroxyl protons of threonine, serine, tyrosine, the amino protons of lysine, and the guanidinium protons of arginine were measured in the pH range 0.5 to 8.5 and for the temperatures 4 degrees C, 10 degrees C, 20 degrees C, 30 degrees C, and 36 degrees C. The intrinsic ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910350106
更新日期:1996-01-01 00:00:00