Manganese-enhanced MRI of salivary glands and head and neck tumors in living subjects.

Abstract:

:Manganese-enhanced MRI has previously been used for visualization of brain architecture and functional mapping of neural pathways. The present work investigated the potential of manganese-enhanced MRI for noninvasive imaging of salivary glands in living subjects. Marked shortening of T(1) was observed in salivary glands of naïve mice (n = 5) 24-48 h after systemic administration of MnCl(2) (0.4 mmol/kg, intraperitoneally). Three-dimensional MR microscopy confirmed selective contrast enhancement of salivary gland tissues post-MnCl(2) injection. Ectopic and orthotopic head and neck tumor xenografts also showed an increase in R(1) at 24 h following MnCl(2) injection (0.2 mmol/kg, intraperitoneally). However, tumor enhancement was minimal compared to salivary gland tissue. Salivary gland R(1) values were lower in mice bearing orthotopic head and neck tumors compared to naïve mice. These results demonstrate, for the first time, the usefulness of manganese-enhanced MRI in the visualization of salivary glands and head and neck tumors in vivo.

journal_name

Magn Reson Med

authors

Seshadri M,Hoy A

doi

10.1002/mrm.22452

subject

Has Abstract

pub_date

2010-09-01 00:00:00

pages

902-6

issue

3

eissn

0740-3194

issn

1522-2594

journal_volume

64

pub_type

杂志文章
  • Fast multislice T(1) and t(1sat) imaging using a phase acquisition of composite echoes (PACE) technique.

    abstract::An optimized multislice data acquisition scheme for phase acquisition of composite echoes (PACE) imaging is presented. This new scheme uses a repetition time equal to the mixing time and an appropriate phase cycling scheme, which allows for more efficient exploitation of all composite echoes. These modifications provi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199912)42:6<1089::aid-mrm1

    authors: Ropele S,Stollberger R,Kapeller P,Hartung HP,Fazekas F

    更新日期:1999-12-01 00:00:00

  • Investigation of a whole-body receiver coil operating at liquid nitrogen temperatures.

    abstract::This communication describes the design and application of a receiver coil operating at liquid nitrogen temperature and intended as a surface coil in a whole-body imager. Its particular application is seen as the external receiver for parasitic internal or implanted detectors. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910070211

    authors: Hall AS,Barnard B,McArthur P,Gilderdale DJ,Young IR,Bydder GM

    更新日期:1988-06-01 00:00:00

  • Determining the extent to which delayed-enhancement images reflect the partition-coefficient of Gd-DTPA in canine studies of reperfused and unreperfused myocardial infarction.

    abstract::MRI after a constant infusion (CI) of Gd-DTPA has been used to identify the extent of myocardial infarction (MI). However, Gd-DTPA-enhanced "viability" imaging is more commonly performed with a bolus (for "delayed-enhancement" (DE) imaging). This study sought to determine how image delay time and time postinfarction i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20236

    authors: Thornhill RE,Prato FS,Wisenberg G,Moran GR,Sykes J

    更新日期:2004-11-01 00:00:00

  • Motion corrected water/fat whole-heart coronary MR angiography with 100% respiratory efficiency.

    abstract:PURPOSE:To develop a framework for respiratory motion-corrected 3D whole-heart water/fat coronary MR angiography (CMRA) at 3T with reduced and predictable scan time. METHODS:A 3D dual-echo acquisition and respiratory motion-corrected reconstruction framework for water/fat CMRA imaging was developed. The acquisition se...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27732

    authors: Munoz C,Cruz G,Neji R,Botnar RM,Prieto C

    更新日期:2019-08-01 00:00:00

  • Gradient rotating outer volume excitation (GROOVE): A novel method for single-shot two-dimensional outer volume suppression.

    abstract:PURPOSE:To introduce a new outer volume suppression (OVS) technique that uses a single pulse and rotating gradients to accomplish frequency-swept excitation. This new technique, which is called gradient rotating outer volume excitation (GROOVE), produces a circular or elliptical suppression band rather than suppressing...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25101

    authors: Powell NJ,Jang A,Park JY,Valette J,Garwood M,Marjańska M

    更新日期:2015-01-01 00:00:00

  • Deconvolution-interpolation gridding (DING): accurate reconstruction for arbitrary k-space trajectories.

    abstract::A simple iterative algorithm, termed deconvolution-interpolation gridding (DING), is presented to address the problem of reconstructing images from arbitrarily-sampled k-space. The new algorithm solves a sparse system of linear equations that is equivalent to a deconvolution of the k-space with a small window. The dec...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21095

    authors: Gabr RE,Aksit P,Bottomley PA,Youssef AB,Kadah YM

    更新日期:2006-12-01 00:00:00

  • Pseudo-projection-driven, self-gated cardiac cine imaging using cartesian golden step phase encoding.

    abstract:PURPOSE:To develop and evaluate a novel two-dimensional self-gated imaging technique for free-breathing cardiac cine MRI that is free of motion-detection overhead and requires minimal planning for motion tracking. METHODS:Motion along the readout direction was extracted solely from normal Cartesian imaging readouts ne...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25834

    authors: Guo L,Derbyshire JA,Herzka DA

    更新日期:2016-08-01 00:00:00

  • T2 relaxation-time mapping in healthy and diseased skeletal muscle using extended phase graph algorithms.

    abstract:PURPOSE:Multi-echo spin-echo (MSE) transverse relaxometry mapping using multi-component models is used to study disease activity in neuromuscular disease by assessing the T2 of the myocytic component (T2water ). Current extended phase graph algorithms are not optimized for fat fractions above 50% and the effects of ina...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28290

    authors: Keene KR,Beenakker JM,Hooijmans MT,Naarding KJ,Niks EH,Otto LAM,van der Pol WL,Tannemaat MR,Kan HE,Froeling M

    更新日期:2020-11-01 00:00:00

  • Stereotaxic assembly and procedures for simultaneous electrophysiological and MRI study of conscious rat.

    abstract::A stereotaxic restraining assembly was designed and developed for simultaneous electrophysiological recordings and functional MRI (fMRI) data acquisition from a conscious rat. The design of the nonmagnetic stereotaxic apparatus facilitated the restraining of head and body of the unanesthetized conscious animal during ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10441

    authors: Khubchandani M,Mallick HN,Jagannathan NR,Mohan Kumar V

    更新日期:2003-05-01 00:00:00

  • MRI-based transfer function determination through the transfer matrix by jointly fitting the incident and scattered B 1 + field.

    abstract:PURPOSE:A purely experimental method for MRI-based transfer function (TF) determination is presented. A TF characterizes the potential for radiofrequency heating of a linear implant by relating the incident tangential electric field to a scattered electric field at its tip. We utilize the previously introduced transfer...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27974

    authors: Tokaya JP,Raaijmakers AJE,Luijten PR,Sbrizzi A,van den Berg CAT

    更新日期:2020-03-01 00:00:00

  • Restricted field of view magnetic resonance imaging of a dynamic time series.

    abstract::A restricted field of view (rFOV) approach for imaging a dynamic time series of volumes of limited spatial extent within a larger subject is described. The shorter readout with rFOV-MRI can be exploited to either limit image artifacts or increase spatial resolution. To accomplish rFOV imaging of a multislice volume fo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21115

    authors: Pisani L,Bammer R,Glover G

    更新日期:2007-02-01 00:00:00

  • Correlation of spectroscopy and magnetization transfer imaging in the evaluation of demyelinating lesions and normal appearing white matter in multiple sclerosis.

    abstract::Magnetization transfer imaging (MT) and localized proton spectroscopy (1H-MRS) were utilized in the evaluation of lesions (high signal abnormalities on T2-weighted images) and normal-appearing white matter (NAWM) in multiple sclerosis (MS). Eleven patients with a clinical diagnosis of MS were independently evaluated w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320303

    authors: Hiehle JF Jr,Lenkinski RE,Grossman RI,Dousset V,Ramer KN,Schnall MD,Cohen JA,Gonzalez-Scarano F

    更新日期:1994-09-01 00:00:00

  • Investigating temporal fluctuations in tumor vasculature with combined carbogen and ultrasmall superparamagnetic iron oxide particle (CUSPIO) imaging.

    abstract::A combined carbogen ultrasmall superparamagnetic iron oxide (USPIO) imaging protocol was developed and applied in vivo in two murine colorectal tumor xenograft models, HCT116 and SW1222, with established disparate vascular morphology, to investigate whether additional information could be extracted from the combinatio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22779

    authors: Burrell JS,Walker-Samuel S,Baker LC,Boult JK,Ryan AJ,Waterton JC,Halliday J,Robinson SP

    更新日期:2011-07-01 00:00:00

  • 16-channel bow tie antenna transceiver array for cardiac MR at 7.0 tesla.

    abstract:PURPOSE:To design, evaluate, and apply a bow tie antenna transceiver radiofrequency (RF) coil array tailored for cardiac MRI at 7.0 Tesla (T). METHODS:The radiofrequency (RF) coil array comprises 16 building blocks each containing a bow tie shaped λ/2-dipole antenna. Numerical simulations were used for transmission fi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25840

    authors: Oezerdem C,Winter L,Graessl A,Paul K,Els A,Weinberger O,Rieger J,Kuehne A,Dieringer M,Hezel F,Voit D,Frahm J,Niendorf T

    更新日期:2016-06-01 00:00:00

  • Characterization of estrogen-receptor-targeted contrast agents in solution, breast cancer cells, and tumors in vivo.

    abstract::The estrogen receptor (ER) is a major prognostic biomarker of breast cancer, currently determined in surgical specimens by immunohistochemistry. Two new ER-targeted probes, pyridine-tetra-acetate-Gd chelate (PTA-Gd) conjugated either to 17β-estradiol (EPTA-Gd) or to tamoxifen (TPTA-Gd), were explored as contrast agent...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24442

    authors: Pais A,Biton IE,Margalit R,Degani H

    更新日期:2013-07-01 00:00:00

  • Real-time cardiovascular MR with spatio-temporal artifact suppression using deep learning-proof of concept in congenital heart disease.

    abstract:PURPOSE:Real-time assessment of ventricular volumes requires high acceleration factors. Residual convolutional neural networks (CNN) have shown potential for removing artifacts caused by data undersampling. In this study, we investigated the ability of CNNs to reconstruct highly accelerated radial real-time data in pat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27480

    authors: Hauptmann A,Arridge S,Lucka F,Muthurangu V,Steeden JA

    更新日期:2019-02-01 00:00:00

  • Development and optimization of hardware for delta relaxation enhanced MRI.

    abstract:PURPOSE:Delta relaxation enhanced magnetic resonance (dreMR) imaging requires an auxiliary B0 electromagnet capable of shifting the main magnetic field within a clinical 1.5 Tesla (T) MR system. In this work, the main causes of interaction between an actively shielded, insertable resistive B0 electromagnet and a 1.5T s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25014

    authors: Harris CT,Handler WB,Araya Y,Martínez-Santiesteban F,Alford JK,Dalrymple B,Van Sas F,Chronik BA,Scholl TJ

    更新日期:2014-10-01 00:00:00

  • Assessment of quantitative artificial neural network analysis in a metabolically dynamic ex vivo 31P NMR pig liver study.

    abstract::Quantitative artificial neural network analysis for 1550 ex vivo 31P nuclear magnetic resonance spectra from hypothermically reperfused pig livers was assessed. These spectra show wide ranges of metabolite concentrations and have been analyzed using metabolite prior knowledge based lineshape fitting analysis which had...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380522

    authors: Ala-Korpela M,Changani KK,Hiltunen Y,Bell JD,Fuller BJ,Bryant DJ,Taylor-Robinson SD,Davidson BR

    更新日期:1997-11-01 00:00:00

  • Initial investigation of a novel noninvasive weight loss therapy using MRI-Guided high intensity focused ultrasound (MR-HIFU) of visceral fat.

    abstract:PURPOSE:MRI-guided high intensity focused ultrasound (MR-HIFU) allows noninvasive heating of deep tissues. Specifically targeting visceral fat deposits with MR-HIFU could offer an effective therapy for reversing the development of obesity, diabetes, and metabolic syndrome. METHODS:Overweight rats received either MR-HI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25883

    authors: Winter PM,Lanier M,Partanen A,Dumoulin C

    更新日期:2016-07-01 00:00:00

  • Wideband myocardial perfusion pulse sequence for imaging patients with a cardiac implantable electronic device.

    abstract:PURPOSE:To develop a wideband cardiac perfusion pulse sequence and test whether it is capable of suppressing image artifacts in patients with a cardiac implantable electronic device (CIED), while not exceeding the specific absorption rate (SAR) limit (2.0 W/kg). METHODS:A wideband perfusion pulse sequence was develope...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27458

    authors: Hong K,Collins JD,Knight BP,Carr JC,Lee DC,Kim D

    更新日期:2019-02-01 00:00:00

  • In vivo 3D MRI staining of mouse brain after subcutaneous application of MnCl2.

    abstract::Follow-up T(1)-weighted 3D gradient-echo MRI (2.35 T) of murine brain in vivo (N = 5) at 120 microm isotropic resolution revealed spatially distinct signal increases 6-48 hr after subcutaneous application of MnCl(2) (20 mg/kg). The effects result from a shortening of the water proton T(1) relaxation time due to the pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10276

    authors: Watanabe T,Natt O,Boretius S,Frahm J,Michaelis T

    更新日期:2002-11-01 00:00:00

  • Carbon-13 "magic-angle" sample-spinning nuclear magnetic resonance studies of human myelin, and model membrane systems.

    abstract::We have obtained high-field (11.7 Tesla), high-resolution carbon-13 solid-state "magic-angle" sample-spinning nuclear magnetic resonance (NMR) spectra of a variety of phospholipids, sphingolipids, myelin and white matter samples, resolving and assigning over 40 resonances in the spectra of human and bovine myelin. The...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290204

    authors: Husted C,Montez B,Le C,Moscarello MA,Oldfield E

    更新日期:1993-02-01 00:00:00

  • 31P nuclear magnetic resonance study of acute renal dysfunction in rat kidney transplants.

    abstract::31P NMR spectroscopy was used to study renal allografts in rats subjected to allograft rejection, cyclosporine toxicity, ischemia, and ureteral obstruction. Parameters of relative peak areas and intracellular pH were accurately distinguished among the different causes of graft dysfunction. Ureteral obstruction was cle...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050405

    authors: Shapiro JI,Haug CE,Weil R 3rd,Chan L

    更新日期:1987-10-01 00:00:00

  • Fast diffusion tensor imaging and tractography of the whole cervical spinal cord using point spread function corrected echo planar imaging.

    abstract::Diffusion tensor imaging has been used in a number of spinal cord studies, but severe distortions caused by susceptibility induced field inhomogeneities limit its applicability to investigate small volumes within acceptable acquisition times. A way to evaluate image distortions is to map the point spread function of t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24235

    authors: Lundell H,Barthelemy D,Biering-Sørensen F,Cohen-Adad J,Nielsen JB,Dyrby TB

    更新日期:2013-01-01 00:00:00

  • Contributions of chemical exchange to T1ρ dispersion in a tissue model.

    abstract::Variations in T(1ρ) with locking-field strength (T(1ρ) dispersion) may be used to estimate proton exchange rates. We developed a novel approach utilizing the second derivative of the dispersion curve to measure exchange in a model system of cross-linked polyacrylamide gels. These gels were varied in relative compositi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22947

    authors: Cobb JG,Xie J,Gore JC

    更新日期:2011-12-01 00:00:00

  • Specific absorption rate benefits of including measured electric field interactions in parallel excitation pulse design.

    abstract::Specific absorption rate management and excitation fidelity are key aspects of radiofrequency pulse design for parallel transmission at ultra-high magnetic field strength. The design of radiofrequency pulses for multiple channels is often based on the solution of regularized least-squares optimization problems for whi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23004

    authors: Deniz CM,Alon L,Brown R,Sodickson DK,Zhu Y

    更新日期:2012-01-01 00:00:00

  • Analysis and correction of motion artifacts in diffusion weighted imaging.

    abstract::For diffusion-weighted magnetic resonance imaging and under circumstances where patient movement can be modeled as rigid body motion, it is shown both theoretically and experimentally that translations and rotations produce phase errors which are zero- and first-order, respectively, in position. While a navigator echo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320313

    authors: Anderson AW,Gore JC

    更新日期:1994-09-01 00:00:00

  • High-resolution 31 P echo-planar spectroscopic imaging in vivo at 7T.

    abstract:PURPOSE:Conventional 31 P chemical shift imaging is time-consuming and yields only limited spatial resolution. The purpose of this study was to demonstrate feasibility of 31 P echo-planar spectroscopic imaging (EPSI) in vivo at 7T. METHODS:A 3D 31 P EPSI sequence with trapezoidal-shaped gradient pulses was implemented...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26785

    authors: Korzowski A,Bachert P

    更新日期:2018-03-01 00:00:00

  • Image contrast using the secondary and tertiary eigenvectors in diffusion tensor imaging.

    abstract::Diffusion tensor imaging (DTI) is a new imaging modality that can provide unique information on brain white matter anatomy. Measurements of water diffusion constant along multiple axes are fitted to a tensor model, from which the diffusion anisotropy and dominant fiber orientation can be estimated. Even though the ten...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20767

    authors: Zhang J,van Zijl PC,Mori S

    更新日期:2006-02-01 00:00:00

  • Simultaneous multi-site EPR spectroscopy in vivo.

    abstract::A gradient technique to measure electron paramagnetic resonance spectra simultaneously at several different locations is described. The technique is based on the use of point probes containing paramagnetic centers. The value of the magnetic field gradient is chosen to be sufficient to separate the EPR signals from the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300210

    authors: Smirnov AI,Norby SW,Clarkson RB,Walczak T,Swartz HM

    更新日期:1993-08-01 00:00:00