Abstract:
:Manganese-enhanced MRI has previously been used for visualization of brain architecture and functional mapping of neural pathways. The present work investigated the potential of manganese-enhanced MRI for noninvasive imaging of salivary glands in living subjects. Marked shortening of T(1) was observed in salivary glands of naïve mice (n = 5) 24-48 h after systemic administration of MnCl(2) (0.4 mmol/kg, intraperitoneally). Three-dimensional MR microscopy confirmed selective contrast enhancement of salivary gland tissues post-MnCl(2) injection. Ectopic and orthotopic head and neck tumor xenografts also showed an increase in R(1) at 24 h following MnCl(2) injection (0.2 mmol/kg, intraperitoneally). However, tumor enhancement was minimal compared to salivary gland tissue. Salivary gland R(1) values were lower in mice bearing orthotopic head and neck tumors compared to naïve mice. These results demonstrate, for the first time, the usefulness of manganese-enhanced MRI in the visualization of salivary glands and head and neck tumors in vivo.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Seshadri M,Hoy Adoi
10.1002/mrm.22452subject
Has Abstractpub_date
2010-09-01 00:00:00pages
902-6issue
3eissn
0740-3194issn
1522-2594journal_volume
64pub_type
杂志文章abstract::An optimized multislice data acquisition scheme for phase acquisition of composite echoes (PACE) imaging is presented. This new scheme uses a repetition time equal to the mixing time and an appropriate phase cycling scheme, which allows for more efficient exploitation of all composite echoes. These modifications provi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199912)42:6<1089::aid-mrm1
更新日期:1999-12-01 00:00:00
abstract::This communication describes the design and application of a receiver coil operating at liquid nitrogen temperature and intended as a surface coil in a whole-body imager. Its particular application is seen as the external receiver for parasitic internal or implanted detectors. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910070211
更新日期:1988-06-01 00:00:00
abstract::MRI after a constant infusion (CI) of Gd-DTPA has been used to identify the extent of myocardial infarction (MI). However, Gd-DTPA-enhanced "viability" imaging is more commonly performed with a bolus (for "delayed-enhancement" (DE) imaging). This study sought to determine how image delay time and time postinfarction i...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20236
更新日期:2004-11-01 00:00:00
abstract:PURPOSE:To develop a framework for respiratory motion-corrected 3D whole-heart water/fat coronary MR angiography (CMRA) at 3T with reduced and predictable scan time. METHODS:A 3D dual-echo acquisition and respiratory motion-corrected reconstruction framework for water/fat CMRA imaging was developed. The acquisition se...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27732
更新日期:2019-08-01 00:00:00
abstract:PURPOSE:To introduce a new outer volume suppression (OVS) technique that uses a single pulse and rotating gradients to accomplish frequency-swept excitation. This new technique, which is called gradient rotating outer volume excitation (GROOVE), produces a circular or elliptical suppression band rather than suppressing...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25101
更新日期:2015-01-01 00:00:00
abstract::A simple iterative algorithm, termed deconvolution-interpolation gridding (DING), is presented to address the problem of reconstructing images from arbitrarily-sampled k-space. The new algorithm solves a sparse system of linear equations that is equivalent to a deconvolution of the k-space with a small window. The dec...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21095
更新日期:2006-12-01 00:00:00
abstract:PURPOSE:To develop and evaluate a novel two-dimensional self-gated imaging technique for free-breathing cardiac cine MRI that is free of motion-detection overhead and requires minimal planning for motion tracking. METHODS:Motion along the readout direction was extracted solely from normal Cartesian imaging readouts ne...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25834
更新日期:2016-08-01 00:00:00
abstract:PURPOSE:Multi-echo spin-echo (MSE) transverse relaxometry mapping using multi-component models is used to study disease activity in neuromuscular disease by assessing the T2 of the myocytic component (T2water ). Current extended phase graph algorithms are not optimized for fat fractions above 50% and the effects of ina...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28290
更新日期:2020-11-01 00:00:00
abstract::A stereotaxic restraining assembly was designed and developed for simultaneous electrophysiological recordings and functional MRI (fMRI) data acquisition from a conscious rat. The design of the nonmagnetic stereotaxic apparatus facilitated the restraining of head and body of the unanesthetized conscious animal during ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10441
更新日期:2003-05-01 00:00:00
abstract:PURPOSE:A purely experimental method for MRI-based transfer function (TF) determination is presented. A TF characterizes the potential for radiofrequency heating of a linear implant by relating the incident tangential electric field to a scattered electric field at its tip. We utilize the previously introduced transfer...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27974
更新日期:2020-03-01 00:00:00
abstract::A restricted field of view (rFOV) approach for imaging a dynamic time series of volumes of limited spatial extent within a larger subject is described. The shorter readout with rFOV-MRI can be exploited to either limit image artifacts or increase spatial resolution. To accomplish rFOV imaging of a multislice volume fo...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21115
更新日期:2007-02-01 00:00:00
abstract::Magnetization transfer imaging (MT) and localized proton spectroscopy (1H-MRS) were utilized in the evaluation of lesions (high signal abnormalities on T2-weighted images) and normal-appearing white matter (NAWM) in multiple sclerosis (MS). Eleven patients with a clinical diagnosis of MS were independently evaluated w...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910320303
更新日期:1994-09-01 00:00:00
abstract::A combined carbogen ultrasmall superparamagnetic iron oxide (USPIO) imaging protocol was developed and applied in vivo in two murine colorectal tumor xenograft models, HCT116 and SW1222, with established disparate vascular morphology, to investigate whether additional information could be extracted from the combinatio...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22779
更新日期:2011-07-01 00:00:00
abstract:PURPOSE:To design, evaluate, and apply a bow tie antenna transceiver radiofrequency (RF) coil array tailored for cardiac MRI at 7.0 Tesla (T). METHODS:The radiofrequency (RF) coil array comprises 16 building blocks each containing a bow tie shaped λ/2-dipole antenna. Numerical simulations were used for transmission fi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25840
更新日期:2016-06-01 00:00:00
abstract::The estrogen receptor (ER) is a major prognostic biomarker of breast cancer, currently determined in surgical specimens by immunohistochemistry. Two new ER-targeted probes, pyridine-tetra-acetate-Gd chelate (PTA-Gd) conjugated either to 17β-estradiol (EPTA-Gd) or to tamoxifen (TPTA-Gd), were explored as contrast agent...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24442
更新日期:2013-07-01 00:00:00
abstract:PURPOSE:Real-time assessment of ventricular volumes requires high acceleration factors. Residual convolutional neural networks (CNN) have shown potential for removing artifacts caused by data undersampling. In this study, we investigated the ability of CNNs to reconstruct highly accelerated radial real-time data in pat...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27480
更新日期:2019-02-01 00:00:00
abstract:PURPOSE:Delta relaxation enhanced magnetic resonance (dreMR) imaging requires an auxiliary B0 electromagnet capable of shifting the main magnetic field within a clinical 1.5 Tesla (T) MR system. In this work, the main causes of interaction between an actively shielded, insertable resistive B0 electromagnet and a 1.5T s...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25014
更新日期:2014-10-01 00:00:00
abstract::Quantitative artificial neural network analysis for 1550 ex vivo 31P nuclear magnetic resonance spectra from hypothermically reperfused pig livers was assessed. These spectra show wide ranges of metabolite concentrations and have been analyzed using metabolite prior knowledge based lineshape fitting analysis which had...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910380522
更新日期:1997-11-01 00:00:00
abstract:PURPOSE:MRI-guided high intensity focused ultrasound (MR-HIFU) allows noninvasive heating of deep tissues. Specifically targeting visceral fat deposits with MR-HIFU could offer an effective therapy for reversing the development of obesity, diabetes, and metabolic syndrome. METHODS:Overweight rats received either MR-HI...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25883
更新日期:2016-07-01 00:00:00
abstract:PURPOSE:To develop a wideband cardiac perfusion pulse sequence and test whether it is capable of suppressing image artifacts in patients with a cardiac implantable electronic device (CIED), while not exceeding the specific absorption rate (SAR) limit (2.0 W/kg). METHODS:A wideband perfusion pulse sequence was develope...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27458
更新日期:2019-02-01 00:00:00
abstract::Follow-up T(1)-weighted 3D gradient-echo MRI (2.35 T) of murine brain in vivo (N = 5) at 120 microm isotropic resolution revealed spatially distinct signal increases 6-48 hr after subcutaneous application of MnCl(2) (20 mg/kg). The effects result from a shortening of the water proton T(1) relaxation time due to the pr...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10276
更新日期:2002-11-01 00:00:00
abstract::We have obtained high-field (11.7 Tesla), high-resolution carbon-13 solid-state "magic-angle" sample-spinning nuclear magnetic resonance (NMR) spectra of a variety of phospholipids, sphingolipids, myelin and white matter samples, resolving and assigning over 40 resonances in the spectra of human and bovine myelin. The...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910290204
更新日期:1993-02-01 00:00:00
abstract::31P NMR spectroscopy was used to study renal allografts in rats subjected to allograft rejection, cyclosporine toxicity, ischemia, and ureteral obstruction. Parameters of relative peak areas and intracellular pH were accurately distinguished among the different causes of graft dysfunction. Ureteral obstruction was cle...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910050405
更新日期:1987-10-01 00:00:00
abstract::Diffusion tensor imaging has been used in a number of spinal cord studies, but severe distortions caused by susceptibility induced field inhomogeneities limit its applicability to investigate small volumes within acceptable acquisition times. A way to evaluate image distortions is to map the point spread function of t...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24235
更新日期:2013-01-01 00:00:00
abstract::Variations in T(1ρ) with locking-field strength (T(1ρ) dispersion) may be used to estimate proton exchange rates. We developed a novel approach utilizing the second derivative of the dispersion curve to measure exchange in a model system of cross-linked polyacrylamide gels. These gels were varied in relative compositi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22947
更新日期:2011-12-01 00:00:00
abstract::Specific absorption rate management and excitation fidelity are key aspects of radiofrequency pulse design for parallel transmission at ultra-high magnetic field strength. The design of radiofrequency pulses for multiple channels is often based on the solution of regularized least-squares optimization problems for whi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.23004
更新日期:2012-01-01 00:00:00
abstract::For diffusion-weighted magnetic resonance imaging and under circumstances where patient movement can be modeled as rigid body motion, it is shown both theoretically and experimentally that translations and rotations produce phase errors which are zero- and first-order, respectively, in position. While a navigator echo...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910320313
更新日期:1994-09-01 00:00:00
abstract:PURPOSE:Conventional 31 P chemical shift imaging is time-consuming and yields only limited spatial resolution. The purpose of this study was to demonstrate feasibility of 31 P echo-planar spectroscopic imaging (EPSI) in vivo at 7T. METHODS:A 3D 31 P EPSI sequence with trapezoidal-shaped gradient pulses was implemented...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26785
更新日期:2018-03-01 00:00:00
abstract::Diffusion tensor imaging (DTI) is a new imaging modality that can provide unique information on brain white matter anatomy. Measurements of water diffusion constant along multiple axes are fitted to a tensor model, from which the diffusion anisotropy and dominant fiber orientation can be estimated. Even though the ten...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20767
更新日期:2006-02-01 00:00:00
abstract::A gradient technique to measure electron paramagnetic resonance spectra simultaneously at several different locations is described. The technique is based on the use of point probes containing paramagnetic centers. The value of the magnetic field gradient is chosen to be sufficient to separate the EPR signals from the...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910300210