Fast multislice T(1) and t(1sat) imaging using a phase acquisition of composite echoes (PACE) technique.

Abstract:

:An optimized multislice data acquisition scheme for phase acquisition of composite echoes (PACE) imaging is presented. This new scheme uses a repetition time equal to the mixing time and an appropriate phase cycling scheme, which allows for more efficient exploitation of all composite echoes. These modifications provide true multislice capability in parallel to a reduction of the acquisition time by a factor >2 compared with the original PACE method. Moreover, T(1) values can be obtained directly from phase images without the use of a lookup table. Because of the symmetrical application of the radio frequency pulses, this method is also well suited for T(1sat) imaging. Phantom studies showed a significantly better accuracy of the multislice fast PACE technique compared with a conventional two-point method in multislice acquisition mode, although precision was limited at high T(1) values. T(1) and T(1sat) measurements in brain tissue of eight healthy volunteers confirmed the stability of the fast PACE technique in a clinical setting. Magn Reson Med 42:1089-1097, 1999.

journal_name

Magn Reson Med

authors

Ropele S,Stollberger R,Kapeller P,Hartung HP,Fazekas F

doi

10.1002/(sici)1522-2594(199912)42:6<1089::aid-mrm1

subject

Has Abstract

pub_date

1999-12-01 00:00:00

pages

1089-97

issue

6

eissn

0740-3194

issn

1522-2594

pii

10.1002/(SICI)1522-2594(199912)42:6<1089::AID-MRM1

journal_volume

42

pub_type

杂志文章
  • Dynamic activity-induced manganese-dependent contrast magnetic resonance imaging (DAIM MRI).

    abstract::Activity-induced manganese-dependent contrast (AIM) MRI is a hemodynamic-independent functional MRI method that used manganese ion as an MR-detectable contrast agent. In AIM, MnCl(2) is infused intra-arterially after the blood-brain barrier (BBB) is opened with a hyperosmolar agent. Upon functional stimulation of the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10320

    authors: Aoki I,Tanaka C,Takegami T,Ebisu T,Umeda M,Fukunaga M,Fukuda K,Silva AC,Koretsky AP,Naruse S

    更新日期:2002-12-01 00:00:00

  • Magnetic resonance imaging of myocardial kinematics. Technique to detect, localize, and quantify the strain rates of the active human myocardium.

    abstract::A magnetic resonance imaging (MRI) method is presented to detect, localize, and quantify myocardial kinematics by measuring the material rate-of-strain tensor at each pixel in gated NMR images of the heart. The immediate, local effect of muscular activity is self-deformation, and the strain tensor is the basic mathema...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910270107

    authors: Wedeen VJ

    更新日期:1992-09-01 00:00:00

  • In vivo 3D MRI staining of mouse brain after subcutaneous application of MnCl2.

    abstract::Follow-up T(1)-weighted 3D gradient-echo MRI (2.35 T) of murine brain in vivo (N = 5) at 120 microm isotropic resolution revealed spatially distinct signal increases 6-48 hr after subcutaneous application of MnCl(2) (20 mg/kg). The effects result from a shortening of the water proton T(1) relaxation time due to the pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10276

    authors: Watanabe T,Natt O,Boretius S,Frahm J,Michaelis T

    更新日期:2002-11-01 00:00:00

  • Diffusion tensor imaging of in vivo and excised rat spinal cord at 7 T with an icosahedral encoding scheme.

    abstract::Regional values of fractional anisotropy (FA) and mean diffusivity (D(av)) of in vivo and excised rat spinal cords were measured using an iscosahedral encoding scheme that is based on 21 uniformly distributed and alternating gradient directions with an echo planar imaging (EPI) readout. Based on the water phantom stud...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20304

    authors: Madi S,Hasan KM,Narayana PA

    更新日期:2005-01-01 00:00:00

  • In vivo MR elastography of the prostate gland using a transurethral actuator.

    abstract::Conventional approaches for MR elastography (MRE) using surface drivers have difficulty achieving sufficient shear wave propagation in the prostate gland due to attenuation. In this study we evaluate the feasibility of generating shear wave propagation in the prostate gland using a transurethral device. A novel transu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22038

    authors: Chopra R,Arani A,Huang Y,Musquera M,Wachsmuth J,Bronskill M,Plewes D

    更新日期:2009-09-01 00:00:00

  • Local planar gradients with order-of-magnitude strength and speed advantage.

    abstract::A three-axis uniplanar gradient coil was designed and built to provide order-of-magnitude increases in gradient strength of up to 500 mT/m on the x- and y-axes, and 1000 mT/m for the z-axis at 640 A input over a limited FOV ( approximately 16 cm) for superficial regions, compared to conventional gradient coils, with s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21263

    authors: Aksel B,Marinelli L,Collick BD,Von Morze C,Bottomley PA,Hardy CJ

    更新日期:2007-07-01 00:00:00

  • A highly sensitive lactate editing technique for surface coil spectroscopic imaging in vivo.

    abstract::A lactate editing sequence based on the use of spin-locking pulses with surface coils is described. The sequence retains more than 90% of the available lactate magnetization and suppresses at least 95% of the lipid signal in a single scan and ca. 99.5% after a simple two step cycle. The technique allows simultaneous o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290320

    authors: Bourgeois D,Kozlowski P

    更新日期:1993-03-01 00:00:00

  • iDQC anisotropy map imaging for tumor tissue characterization in vivo.

    abstract::Intermolecular double quantum coherences (iDQCs), signals that result from simultaneous transitions of two or more separated spins, are known to produce images that are highly sensitive to subvoxel structure, particularly local anisotropy. Here we demonstrate how iDQCs signal can be used to efficiently detect the anis...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21925

    authors: Branca RT,Chen YM,Mouraviev V,Galiana G,Jenista ER,Kumar C,Leuschner C,Warren WS

    更新日期:2009-04-01 00:00:00

  • Input parameter sensitivity analysis and comparison of quantification models for continuous arterial spin labeling.

    abstract::The regional cerebral blood flow (rCBF) values determined using continuous arterial spin labeling (CASL) are subject to several sources of variability, including natural physiologic variations, sensitivity to the input parameters, and the use of different quantification models. To date, a thorough analysis of the impa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20440

    authors: Steger TR,White RA,Jackson EF

    更新日期:2005-04-01 00:00:00

  • Evidence that both fast and slow water ADC components arise from intracellular space.

    abstract::Evaluation of water diffusion in the brain has revealed both fast- and slow-diffusing water populations. It has been suggested that these populations represent extra- and intracellular water, respectively. We have identified and characterized both populations in the intracellular space of the Xenopus oocyte. We have a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10301

    authors: Sehy JV,Ackerman JJ,Neil JJ

    更新日期:2002-11-01 00:00:00

  • Phase-sensitive inversion recovery for myocardial T1 mapping with motion correction and parametric fitting.

    abstract::The assessment of myocardial fibrosis and extracellular volume requires accurate estimation of myocardial T1 s. While image acquisition using the modified Look-Locker inversion recovery technique is clinically feasible for myocardial T1 mapping, respiratory motion can limit its applicability. Moreover, the conventiona...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24385

    authors: Xue H,Greiser A,Zuehlsdorff S,Jolly MP,Guehring J,Arai AE,Kellman P

    更新日期:2013-05-01 00:00:00

  • Automatic segmentation of the brain and intracranial cerebrospinal fluid in T1-weighted volume MRI scans of the head, and its application to serial cerebral and intracranial volumetry.

    abstract::A new fully automatic algorithm for the segmentation of the brain and total intracranial cerebrospinal fluid (CSF) from T(1)-weighted volume MRI scans of the head, called Exbrain v.2, is described. The algorithm was developed in the context of serial intracranial volumetry. A brain mask obtained using a previous versi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10436

    authors: Lemieux L,Hammers A,Mackinnon T,Liu RS

    更新日期:2003-05-01 00:00:00

  • Transcatheter intra-arterial perfusion (TRIP)-MRI biomarkers help detect immediate response to irreversible electroporation of rabbit VX2 liver tumor.

    abstract:PURPOSE:Irreversible electroporation (IRE) is a nonthermal tissue ablation technique that represents a promising treatment option for unresectable liver tumors, but the effectively treated zone cannot be reliably predicted. We investigate the potential benefit of transcatheter intra-arterial perfusion (TRIP) -MRI for t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28104

    authors: Figini M,Zhou K,Pan L,Sun C,Wang B,Hu S,Yang J,Shangguan J,Eresen A,Velichko Y,Yaghmai V,Zhang Z

    更新日期:2020-07-01 00:00:00

  • Single-shot localized echo-planar imaging (STEAM-EPI) at 4.7 tesla.

    abstract::The resolution and homogeneity limitations of echo-planar imaging (EPI) are overcome by zoom imaging of an easily shimmed localized volume. Use of the stimulated echo enables single-shot localization. In vivo 0.5-mm resolution EPI images of selected regions of a cat brain at 4.7 T are presented. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910140225

    authors: Turner R,von Kienlin M,Moonen CT,van Zijl PC

    更新日期:1990-05-01 00:00:00

  • Single acquisition electrical property mapping based on relative coil sensitivities: A proof-of-concept demonstration.

    abstract:PURPOSE:All methods presented to date to map both conductivity and permittivity rely on multiple acquisitions to compute quantitatively the magnitude of radiofrequency transmit fields, B1+. In this work, we propose a method to compute both conductivity and permittivity based solely on relative receive coil sensitivitie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25399

    authors: Marques JP,Sodickson DK,Ipek O,Collins CM,Gruetter R

    更新日期:2015-07-01 00:00:00

  • Combined spin- and gradient-echo perfusion-weighted imaging.

    abstract::In this study, a spin- and gradient-echo echo-planar imaging (SAGE EPI) MRI pulse sequence is presented that allows simultaneous measurements of gradient-echo and spin-echo dynamic susceptibility-contrast perfusion-weighted imaging data. Following signal excitation, five readout trains were acquired using spin- and gr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23195

    authors: Schmiedeskamp H,Straka M,Newbould RD,Zaharchuk G,Andre JB,Olivot JM,Moseley ME,Albers GW,Bammer R

    更新日期:2012-07-01 00:00:00

  • Compartment size estimation with double wave vector diffusion-weighted imaging.

    abstract::Double wave vector diffusion weighting uses gradients along two different directions between excitation and acquisition. It has been shown theoretically that for restricted diffusion the signal amplitude in such an experiment can depend on the angle between the two gradient vectors. The highest amplitude is obtained w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21514

    authors: Koch MA,Finsterbusch J

    更新日期:2008-07-01 00:00:00

  • Metabolic assessment of a migraine model using relaxation-enhanced 1 H spectroscopy at ultrahigh field.

    abstract:PURPOSE:This study evaluates biochemical imbalances in a rat model that reflects dysfunctional pathways in migraine. The high sensitivity and spectral dispersion available to 1 H MRS at 21.1 T expands metabolic profiling in this migraine model to include lactate (Lac), taurine (Tau), aspartate, and Gly-a mixture of gly...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26811

    authors: Abad N,Rosenberg JT,Roussel T,Grice DC,Harrington MG,Grant SC

    更新日期:2018-03-01 00:00:00

  • Temporal frequency analysis of dynamic MRI techniques.

    abstract::Dynamic imaging strategies often involve updating certain areas of k-space (i.e., the low spatial frequencies) more frequently than others. However, important dynamic signal changes may occur anywhere in k-space. In this study, a dynamic k-space sampling analysis method was developed to determine the energy error asso...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1074

    authors: Wu Y,Alexander AL

    更新日期:2001-04-01 00:00:00

  • Self-navigated 4D cartesian imaging of periodic motion in the body trunk using partial k-space compressed sensing.

    abstract:PURPOSE:To enable fast and flexible high-resolution four-dimensional (4D) MRI of periodic thoracic/abdominal motion for motion visualization or motion-corrected imaging. METHODS:We proposed a Cartesian three-dimensional k-space sampling scheme that acquires a random combination of k-space lines in the ky/kz plane. A p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26406

    authors: Küstner T,Würslin C,Schwartz M,Martirosian P,Gatidis S,Brendle C,Seith F,Schick F,Schwenzer NF,Yang B,Schmidt H

    更新日期:2017-08-01 00:00:00

  • Unifying linear prior-information-driven methods for accelerated image acquisition.

    abstract::In the ongoing quest for faster imaging and higher spatial resolution, several methods have been developed to speed up data acquisition by incorporating prior information about the object being imaged. This study shows that many of these methods can be integrated into a single common equation. The unified framework pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1242

    authors: Tsao J,Behnia B,Webb AG

    更新日期:2001-10-01 00:00:00

  • Evidence for enhanced functional activity of cervical cord in relapsing multiple sclerosis.

    abstract::Functional MRI (fMRI) was used to assess proprioceptive-associated cervical cord activity in 24 relapsing multiple sclerosis (MS) patients and 10 controls. Cord and brain conventional and diffusion tensor (DT) MRI were also acquired. fMRI was performed using a block design during a proprioceptive stimulation consistin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21595

    authors: Agosta F,Valsasina P,Rocca MA,Caputo D,Sala S,Judica E,Stroman PW,Filippi M

    更新日期:2008-05-01 00:00:00

  • Total brain N-acetylaspartate concentration in normal, age-grouped females: quantitation with non-echo proton NMR spectroscopy.

    abstract::The intra-individual and inter-individual variations of the global N-acetylaspartate (NAA) concentration were measured in a cohort of five 42+/-5 year-old normal females. The total NAA signal from the whole head was obtained with non-localized non-echo proton spectroscopy (1H-MRS) and converted into absolute mole amou...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.1910400506

    authors: Gonen O,Viswanathan AK,Catalaa I,Babb J,Udupa J,Grossman RI

    更新日期:1998-11-01 00:00:00

  • Evaluation of hepatic steatosis before liver transplantation in ex vivo by volumetric quantitative PDFF-MRI.

    abstract:PURPOSE:Over the last two decades, extended criteria have promoted an increased number of donor livers available for liver transplantation. But posttransplant graft loss is still a major concern. Macrovesicular hepatic steatosis (MHS) is recognized as the most significant prognostic histologic parameter in predicting p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28592

    authors: Chen G,Jiang J,Wang X,Yang M,Xie Y,Guo H,Tang H,Zhou L,Hu D,Kamel IR,Chen Z,Li Z

    更新日期:2020-11-16 00:00:00

  • Template-based field map prediction for rapid whole brain B0 shimming.

    abstract:PURPOSE:In typical MRI protocols, time is spent acquiring a field map to calculate the shim settings for best image quality. We propose a fast template-based field map prediction method that yields near-optimal shims without measuring the field. METHODS:The template-based prediction method uses prior knowledge of the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27020

    authors: Shi Y,Vannesjo SJ,Miller KL,Clare S

    更新日期:2018-07-01 00:00:00

  • Iterative k-t principal component analysis with nonrigid motion correction for dynamic three-dimensional cardiac perfusion imaging.

    abstract:PURPOSE:In this study, an iterative k-t principal component analysis (PCA) algorithm with nonrigid frame-to-frame motion correction is proposed for dynamic contrast-enhanced three-dimensional perfusion imaging. METHODS:An iterative k-t PCA algorithm was implemented with regularization using training data corrected for...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24894

    authors: Schmidt JF,Wissmann L,Manka R,Kozerke S

    更新日期:2014-07-01 00:00:00

  • Uncovering of intracellular water in cultured cells.

    abstract::The complexity of biologic tissues, with multiple compartments each with its own diffusion and relaxation properties, requires complex formalisms to model water signal in most magnetic resonance imaging or magnetic resonance spectroscopy experiments. In this article, we describe a magnetic susceptibility-induced shift...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20565

    authors: Galons JP,Lope-Piedrafita S,Divijak JL,Corum C,Gillies RJ,Trouard TP

    更新日期:2005-07-01 00:00:00

  • Evaluation of coils for imaging histological slides: signal-to-noise ratio and filling factor.

    abstract:PURPOSE:To investigate the relative gain in sensitivity of five histology coils designed in-house to accommodate tissue sections of various sizes and compare with commercial mouse head coils. METHODS:The coil set was tailored to house tissue sections ranging from 5 to1000 µm encased in either glass slides or coverslip...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24841

    authors: Hoang DM,Voura EB,Zhang C,Fakri-Bouchet L,Wadghiri YZ

    更新日期:2014-05-01 00:00:00

  • Effect of distortion corrections on the tractography quality in spinal cord diffusion-weighted imaging.

    abstract:PURPOSE:To assess the impact of a different distortion correction (DC) method and patient geometry (sagittal balance) on the quality of spinal cord tractography rendering according to different tractography approaches. METHODS:Forty-four adults free of spinal cord diseases underwent cervical diffusion-weighted imaging...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28665

    authors: Dauleac C,Bannier E,Cotton F,Frindel C

    更新日期:2021-01-21 00:00:00

  • Real-time imaging of two-dimensional cardiac strain using a harmonic phase magnetic resonance imaging (HARP-MRI) pulse sequence.

    abstract::The harmonic phase (HARP) method provides automatic and rapid analysis of tagged magnetic resonance (MR) images for quantification and visualization of myocardial strain. In this article, the development and implementation of a pulse sequence that acquires HARP images in real time are described. In this pulse sequence...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.10509

    authors: Sampath S,Derbyshire JA,Atalar E,Osman NF,Prince JL

    更新日期:2003-07-01 00:00:00