Abstract:
:Functional MRI (fMRI) was used to assess proprioceptive-associated cervical cord activity in 24 relapsing multiple sclerosis (MS) patients and 10 controls. Cord and brain conventional and diffusion tensor (DT) MRI were also acquired. fMRI was performed using a block design during a proprioceptive stimulation consisting of a passive flexion-extension of the right upper limb. Cord lesion number, cross-sectional area, mean diffusivity (MD) and fractional anisotropy (FA), whole brain and left corticospinal tract lesion volume (LV), gray matter (GM) MD, and normal-appearing white matter (NAWM) MD and FA were calculated. MS patients had higher average cord fMRI signal changes than controls (3.4% vs. 2.7%, P = 0.03). Compared to controls, MS patients also had a higher average signal change in the anterior section of the right cord at C5 (P = 0.005) and left cord at C5-C6 (P = 0.03), whereas no difference was found in the other cord sections. Cord average signal change correlated significantly with cord FA and brain left corticospinal tract LV, GM-MD, and NAWM-FA. This study shows an abnormal pattern of activations in the cervical cord of MS patients following proprioceptive stimulation. Cord fMRI changes might have a role in limiting the clinical consequences of MS associated with irreversible tissue damage.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Agosta F,Valsasina P,Rocca MA,Caputo D,Sala S,Judica E,Stroman PW,Filippi Mdoi
10.1002/mrm.21595subject
Has Abstractpub_date
2008-05-01 00:00:00pages
1035-42issue
5eissn
0740-3194issn
1522-2594journal_volume
59pub_type
杂志文章abstract::Short image acquisition times and sensitivity to magnetic susceptibility favor the use of gradient echo imaging methods in functional MRI (fMRI). However, magnetic susceptibility effects attributed to air-tissue interfaces also lead to severe signal loss in images of the large inferior frontal and lateral temporal cor...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910370304
更新日期:1997-03-01 00:00:00
abstract::The resolution and homogeneity limitations of echo-planar imaging (EPI) are overcome by zoom imaging of an easily shimmed localized volume. Use of the stimulated echo enables single-shot localization. In vivo 0.5-mm resolution EPI images of selected regions of a cat brain at 4.7 T are presented. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910140225
更新日期:1990-05-01 00:00:00
abstract::Hyperpolarized (HP) 129Xe can be dissolved in biologically compatible lipid emulsions while maintaining sufficient polarization for in vivo vascular imaging. For xenon in Intralipid 30%, in vitro spectroscopy at 2 T yielded a chemical shift of 197 +/- 1 ppm with reference to xenon gas, a spin-lattice relaxation time T...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199905)41:5<1058::aid-mrm2
更新日期:1999-05-01 00:00:00
abstract::The cytosol of intact human red blood cells was loaded with 28.1 +/- 3.4 mM of dysprosium DTPA-BMA using a hypoosmotic technique. When loaded cells were diluted with saline and control cells to give an average dysprosium concentration of 3.3 +/- 0.5 mM, the transverse relaxation rate constants R(*)(2) and R(2) increas...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1122
更新日期:2001-05-01 00:00:00
abstract::The suppression of water signals in in vivo proton spectra by means of multiple-quantum filtering can be brought about in several ways. This communication exposes the shortcomings of using purely subtractive filtering techniques to observe signals from metabolites that contain proton couplings of the form AX3. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910110314
更新日期:1989-09-01 00:00:00
abstract:PURPOSE:Magnetization transfer ratio (MTR) histograms are used widely for the assessment of diffuse pathological changes in the brain. For broad clinical application, MTR scans should not only be fast, but confounding factors should also be minimized for high reproducibility. To this end, a 1-minute whole-brain spiral ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28618
更新日期:2020-12-08 00:00:00
abstract::Hyperpolarized noble gas ((3)He and (129)Xe) apparent diffusion coefficient (ADC) measurements have shown remarkable sensitivity to microstructural (i.e., alveolar) changes in the lung, particularly emphysema. The ADC of hyperpolarized noble gases depends strongly on the diffusion time (Δ), and (3)He ADC has been show...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24224
更新日期:2013-01-01 00:00:00
abstract::The changes in the response of skeletal muscle to maximal dynamic exercise were investigated in going from a fasted state to a refed state by means of 31P NMR spectroscopy. It was found that in the fasted state, exercise-induced changes in Pi/PCr and in pH were both inhibited, in comparison with those in the refed sta...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910030616
更新日期:1986-12-01 00:00:00
abstract::In this high resolution magnetic resonance spectroscopic study of experimental allergic encephalomyelitis (EAE) and Semliki Forest virus (SFV) infection of the Biozzi AB/H mouse, marked increases in the initially low levels of N-trimethyl compounds in the spinal cord were observed during probable demyelinating episode...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910320603
更新日期:1994-12-01 00:00:00
abstract::A reproducibility study of proton MR spectroscopic imaging ((1)H-MRSI) of the human brain was conducted to evaluate the reliability of an automated 3D in vivo spectroscopic imaging acquisition and associated quantification algorithm. A PRESS-based pulse sequence was implemented using dualband spectral-spatial RF pulse...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21713
更新日期:2008-09-01 00:00:00
abstract::To increase image acquisition efficiency, we develop alternative gradient encoding strategies designed to provide spatial encoding complementary to the spatial encoding provided by the multiple receiver coil elements in parallel image acquisitions. Intuitively, complementary encoding is achieved when the magnetic fiel...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24114
更新日期:2012-10-01 00:00:00
abstract::Several methods have been proposed for overcoming the effects of radiofrequency (RF) magnetic field inhomogeneity in high-field MRI. Some of these methods rely at least in part on the ability to independently control magnitude and phase of different drives in either one multielement RF coil or in different RF coils in...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21013
更新日期:2006-10-01 00:00:00
abstract::Among previous analyses of the steady-state free-precession (SSFP) signal in rapid MRI, one treatment resulted in equations that require the evaluation of infinite binomial series. Here, an analytical solution is derived by a transformation into the power series expansion of the derivative of the inverse sine function...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10410
更新日期:2003-04-01 00:00:00
abstract::A novel method for detecting neural activity in functional magnetic resonance imaging (fMRI) data is introduced. It is based on canonical correlation analysis (CCA), which is a multivariate extension of the univariate correlation analysis widely used in fMRI. To detect homogeneous regions of activity, the method combi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/1522-2594(200102)45:2<323::aid-mrm1041>3.0
更新日期:2001-02-01 00:00:00
abstract::MR-thermometry allows monitoring of the local temperature evolution during minimally invasive interventional therapies. However, for the particular case of MR-thermometry in the human breast, magnetic field variations induced by the respiratory cycle lead to phase fluctuations requiring a suitable correction strategy ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21954
更新日期:2009-06-01 00:00:00
abstract::In this study undersampled projection reconstruction (PR) was used for rapid catheter imaging in the heart, employing steady-state free precession (SSFP) contrast. Active catheters and phased-array coils were used for combined imaging of anatomy and catheter position in swine. Real-time imaging of catheter position wa...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10390
更新日期:2003-02-01 00:00:00
abstract:PURPOSE:Noninvasive imaging techniques that quantify renal tissue composition are needed to more accurately ascertain prognosis and monitor disease progression in polycystic kidney disease (PKD). Given the success of magnetization transfer (MT) imaging to characterize various tissue remodeling pathologies, it was teste...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25701
更新日期:2016-04-01 00:00:00
abstract::The signals of water in the different compartments of rat sciatic nerve are resolved in the (2)H double-quantum-filtered NMR spectrum, due to their different quadrupolar splittings and relaxation rates. This resolution allowed the independent measurement of the water diffusion coefficients in the different compartment...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199909)42:3<461::aid-mrm8>
更新日期:1999-09-01 00:00:00
abstract::The ability to directly detect neuronal magnetic fields by MRI would help investigators achieve the "holy grail" of neuroimaging, namely both high spatial and temporal resolution. Both positive and negative findings have been reported in the literature, with no clear consensus as to the feasibility of direct detection...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21129
更新日期:2007-02-01 00:00:00
abstract::To date, most functional imaging centers have relied on ultrafast imaging approaches such as echo-planar imaging (EPI) techniques for acquiring functional brain activation data. These methods require specialized hardware and are not yet installed widely on clinical MR imagers, thus limiting the application of function...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910380417
更新日期:1997-10-01 00:00:00
abstract:PURPOSE:We propose a constrained optimization approach for designing parallel transmit (pTx) pulses satisfying all regulatory and hardware limits. We study the trade-offs between excitation accuracy, local and global specific absorption rate (SAR), and maximum and average power for small flip-angle pTx (eight channels)...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24800
更新日期:2014-04-01 00:00:00
abstract::Intra-plaque hemorrhage (IPH) and lipid core, characteristics of rupture prone carotid plaques, are often visualized in vivo with MRI using T1 weighted gradient and spin echo, respectively. Increasing magnetic field strength may help to identify IPH and lipid core better. As a proof of concept, automatic segmentation ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.23191
更新日期:2012-06-01 00:00:00
abstract::The aim of this study was to detect salvageable peri-infarction myocardium by MRI in rats after infarction, using with a double contrast agent (CA) protocol at 7 Tesla. Intravascular superparamagnetic iron oxide (SPIO) nanoparticles and an extracellular paramagnetic CA (Gd-DOTA) were used to characterize the peri-infa...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20210
更新日期:2004-10-01 00:00:00
abstract::Golgi impregnation is unique in its ability to display the dendritic trees and axons of large numbers of individual neurons by histology. Here we apply magnetic resonance microscopy to visualize the neuroanatomy of animal models by combining histologic fixation chemistry with paramagnetic contrast agents. Although the...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22322
更新日期:2010-05-01 00:00:00
abstract:PURPOSE:To develop a novel, simultaneous multislice reconstruction method that exploits Hankel subspace learning (SMS-HSL) for aliasing separation in the slice direction. METHODS:An SMS signal model with the Hankel-structured matrix was proposed. To efficiently suppress interslice leakage artifacts from a signal subsp...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26527
更新日期:2017-10-01 00:00:00
abstract::Experiments have been performed to demonstrate and quantify cross-relaxation between water and methylene resonances in a simple model system. Inversion recovery experiments on aqueous solutions of polyethylene glycol produce a transient nuclear Overhauser effect that alters the recovery of the methylene resonance. The...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910090305
更新日期:1989-03-01 00:00:00
abstract::Double wave vector diffusion weighting uses gradients along two different directions between excitation and acquisition. It has been shown theoretically that for restricted diffusion the signal amplitude in such an experiment can depend on the angle between the two gradient vectors. The highest amplitude is obtained w...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21514
更新日期:2008-07-01 00:00:00
abstract::Spinal cord (SC) motion is thought to be the dominant source of error in current diffusion and spinal functional MRI (fMRI) methods. However, until now, such motion has not been well characterized in three dimensions. While previous studies have predominantly examined motion in the superior/inferior (S/I) direction, t...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21260
更新日期:2007-07-01 00:00:00
abstract::Continuous arterial spin labeling (CASL) was used to obtain an index of cerebral blood flow (ICBF) in the normal mouse brain and in an orthotopic mouse model of human U87 high-grade glioma at 8.5 T. Under the assumption of a constant tissue:blood partition coefficient for water in different tissues, the mean ICBF (n =...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20029
更新日期:2004-05-01 00:00:00
abstract:PURPOSE:Balanced steady state free precession (bSSFP) imaging suffers from off-resonance artifacts such as signal modulation and banding. Solutions for removal of bSSFP off-resonance dependence are described and compared, and an optimal solution is proposed. THEORY AND METHODS:An Algebraic Solution (AS) that complemen...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26150
更新日期:2017-02-01 00:00:00