High-resolution slice-selective Fourier velocity encoding in congenital heart disease using spiral SENSE with velocity unwrap.

Abstract:

:Quantification of peak velocity is important in the assessment of stenotic flow jets in patients with congenital heart disease. Phase-contrast magnetic resonance underestimates peak velocities. Hence, clinically Doppler ultrasound is used as the reference standard for assessing stenoses. It is possible to accurately measure peak velocity in MR using Fourier velocity encoding (FVE). In this study, a fast, high-resolution slice-selective FVE sequence was developed with the use of spiral trajectories, parallel imaging, and partial Fourier in the velocity dimension and a novel velocity-unwrap technique. The resulting sequence was acquired within a short breath-hold (more than 15 heartbeats) making this FVE technique clinically achievable. Peak velocities were compared from Doppler ultrasound, phase-contrast magnetic resonance, and FVE. Experiments were carried out in vitro and in vivo in 25 patients with congenital heart disease with stenoses. It was shown that in vitro and in vivo phase-contrast magnetic resonance tended to underestimate peak velocity when compared with Doppler ultrasound, whereas FVE agreed well with Doppler ultrasound.

journal_name

Magn Reson Med

authors

Steeden JA,Jones A,Pandya B,Atkinson D,Taylor AM,Muthurangu V

doi

10.1002/mrm.24293

subject

Has Abstract

pub_date

2012-06-01 00:00:00

pages

1538-46

issue

6

eissn

0740-3194

issn

1522-2594

journal_volume

67

pub_type

杂志文章
  • Simple measurement of scanner stability for functional NMR imaging of activation in the brain.

    abstract::Functional MR imaging (fMRI) of activation in the brain is one of the more demanding applications required of an NMR imaging instrument. Since the signal changes in activation imaging are quite small, any instrumental variations can easily compromise the fMRI contrast. The authors describe a simple method for measurin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360422

    authors: Weisskoff RM

    更新日期:1996-10-01 00:00:00

  • NMR quantification of lactate production and efflux and glutamate fractional enrichment in living human prostate biopsies cultured with [1,6-13 C2 ]glucose.

    abstract:PURPOSE:Image-guided prostate biopsies are routinely acquired in the diagnosis and treatment monitoring of prostate cancer, yielding useful tissue for identifying metabolic biomarkers and therapeutic targets. We developed an optimized biopsy tissue culture protocol in combination with [1,6-13 C2 ]glucose labeling and q...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27739

    authors: Bancroft Brown J,Sriram R,VanCriekinge M,Delos Santos R,Sun J,Delos Santos J,Tabatabai ZL,Shinohara K,Nguyen H,Peehl DM,Kurhanewicz J

    更新日期:2019-08-01 00:00:00

  • 3D coronary artery imaging with phase reordering for improved scan efficiency.

    abstract::Three-dimensional (3D) coronary imaging has the potential to overcome problems resulting from vessel tortuosity and to reduce partial volume effects. With these techniques, however, acquisition times are long and respiratory motion artifacts problematical. This work describes the development of a method that applies p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199903)41:3<555::aid-mrm19

    authors: Jhooti P,Keegan J,Gatehouse PD,Collins S,Rowe A,Taylor AM,Firmin DN

    更新日期:1999-03-01 00:00:00

  • Assessment and compensation of susceptibility artifacts in gradient echo MRI of hyperpolarized 3He gas.

    abstract::The effects of macroscopic background field gradients upon 2D gradient echo images of inhaled (3)He in the human lung were investigated at 1.5 T. Effective compensation of in-slice signal loss in (3)He gradient echo images was then demonstrated using a multiple acquisition interleaved single gradient echo sequence. Th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10549

    authors: Wild JM,Fichele S,Woodhouse N,Paley MN,Swift A,Kasuboski L,van Beek EJ

    更新日期:2003-08-01 00:00:00

  • Rapid whole-brain gray matter imaging using single-slab three-dimensional dual-echo fast spin echo: A feasibility study.

    abstract:PURPOSE:To achieve rapid, high resolution whole-brain gray matter (GM) imaging by developing a novel, single-slab three-dimensional dual-echo fast-spin-echo pulse sequence and GM-selective reconstruction. METHODS:Unlike conventional GM imaging that uses time-consuming double-inversion-recovery preparation, the propose...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26910

    authors: Lee H,Kim EY,Sohn CH,Park J

    更新日期:2017-11-01 00:00:00

  • Wavelet packet denoising of magnetic resonance images: importance of Rician noise at low SNR.

    abstract::Wavelet packet analysis is a mathematical transformation that can be used to post-process images, for example, to remove image noise ("denoising"). At a very low signal-to-noise ratio (SNR <5), standard magnitude magnetic resonance images have skewed Rician noise statistics that degrade denoising performance. Since th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199903)41:3<631::aid-mrm29

    authors: Wood JC,Johnson KM

    更新日期:1999-03-01 00:00:00

  • The flip-angle effect: a method for detection of sodium-23 quadrupole splitting in tissue.

    abstract::A method is presented for the detection of quadrupole splitting in tissue, where the spectral line splittings are typically unobservable. The method used is a study of the rate of rotation of the flip angle as a function of radiofrequency (rf) amplitude. Our results with samples of skeletal muscle and cat brain indica...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040108

    authors: Joseph PM,Summers RM

    更新日期:1987-01-01 00:00:00

  • Early changes in water diffusion, perfusion, T1, and T2 during focal cerebral ischemia in the rat studied at 8.5 T.

    abstract::The time evolution of water diffusion, perfusion, T1, and T2 is investigated at high magnetic field (8.5 T) following permanent middle cerebral artery occlusion in the rat. Cerebral blood flow maps were obtained using arterial spin tagging. Although the quantitative perfusion measurements in ischemic tissue still pose...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199903)41:3<479::aid-mrm9>

    authors: Calamante F,Lythgoe MF,Pell GS,Thomas DL,King MD,Busza AL,Sotak CH,Williams SR,Ordidge RJ,Gadian DG

    更新日期:1999-03-01 00:00:00

  • Concentrations of human cardiac phosphorus metabolites determined by SLOOP 31P NMR spectroscopy.

    abstract::Human cardiac 31P nuclear magnetic resonance (NMR) spectra are usually quantified in relative terms, i.e., the ratio of metabolite signals is calculated. If 31P NMR spectroscopy of the heart is to emerge as a clinically relevant diagnostic modality, reliable quantification of absolute concentrations of 31P metabolites...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199904)41:4<657::aid-mrm3>

    authors: Meininger M,Landschütz W,Beer M,Seyfarth T,Horn M,Pabst T,Haase A,Hahn D,Neubauer S,von Kienlin M

    更新日期:1999-04-01 00:00:00

  • A controllable susceptibility marker for passive device tracking.

    abstract:PURPOSE:To design and demonstrate a new susceptibility-based tracking device with an artifact that can be mechanically turned on and off, thus permitting tracking and imaging at the device tip with limited artifact. METHODS:The magnetic susceptibilities of readily obtainable grades of titanium and graphite were measur...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24899

    authors: Dominguez-Viqueira W,Karimi H,Lam WW,Cunningham CH

    更新日期:2014-07-01 00:00:00

  • In vivo detection of 2-hydroxyglutarate in brain tumors by optimized point-resolved spectroscopy (PRESS) at 7T.

    abstract:PURPOSE:To test the efficacy of 7T MRS for in vivo detection of 2-hydroxyglutarate (2HG) in brain tumors. METHODS:The subecho times of point-resolved spectroscopy (PRESS) were optimized at 7T with density-matrix simulations and phantom validation to improve the 2HG signal selectivity with respect to the neighboring re...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26190

    authors: Ganji SK,An Z,Tiwari V,McNeil S,Pinho MC,Pan E,Mickey BE,Maher EA,Choi C

    更新日期:2017-03-01 00:00:00

  • A torque balance measurement of anisotropy of the magnetic susceptibility in white matter.

    abstract:PURPOSE:Recent MRI studies have suggested that the magnetic susceptibility of white matter (WM) in the human brain is anisotropic, providing a new contrast mechanism for the visualization of fiber bundles and allowing the extraction of cellular compartment-specific information. This study provides an independent confir...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25524

    authors: van Gelderen P,Mandelkow H,de Zwart JA,Duyn JH

    更新日期:2015-11-01 00:00:00

  • A fast, analytically based method to optimize local transmit efficiency for a transmit array.

    abstract:PURPOSE:To develop an analytically based algorithm for rapid optimization of the local radiofrequency magnetic (B1+) field intensity for a given radiofrequency power through a transmit array. The analytical nature of the method will yield insight to optimization requirements and provides a valuable reference for numeri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24653

    authors: Carluccio G,Collins CM,Erricolo D

    更新日期:2014-01-01 00:00:00

  • In vivo imaging of extracellular pH using 1H MRSI.

    abstract::Tumor pH is physiologically important since it influences a number of processes relevant to tumorigenesis and therapy. Hence, knowledge of localized pH within tumors would contribute to understanding these processes. The destructiveness, poor spatial resolution, and poor signal-to-noise ratio (SNR) of current technolo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199904)41:4<743::aid-mrm13

    authors: van Sluis R,Bhujwalla ZM,Raghunand N,Ballesteros P,Alvarez J,Cerdán S,Galons JP,Gillies RJ

    更新日期:1999-04-01 00:00:00

  • Three-dimensional MRI with independent slab excitation and encoding.

    abstract::Three-dimensional MRI is typically performed with the same orientation for radiofrequency slab excitation and slab select phase encoding. We introduce independent slab excitation and encoding to create a new degree of freedom in three-dimensional MRI, which is the angular relationship between the prescribed excitation...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23043

    authors: Eissa A,Wilman AH

    更新日期:2012-02-01 00:00:00

  • Direct imaging of hyperpolarized 129Xe alveolar gas uptake in a mouse model of emphysema.

    abstract::MRI of hyperpolarized (129)Xe dissolved in pulmonary tissues, and blood has the potential to offer a new tool for regional evaluation of pulmonary gas exchange and perfusion; however, the extremely short T2* and low magnetization density make it difficult to acquire the image. In this study, an ultrashort echo-time se...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24452

    authors: Iguchi S,Imai H,Hori Y,Nakajima J,Kimura A,Fujiwara H

    更新日期:2013-07-01 00:00:00

  • The phenomenon of separate intra- and extracellular resonances of difluorophosphate in 31P and 19F NMR spectra of erythrocytes.

    abstract::Trifluoroacetate and trifluoroacetamide, when added to a suspension of human red blood cells, give rise to separate 19F NMR signals from the intra- and extracellular species. This phenomenon has recently been exploited for measuring the membrane potential of erythrocytes. However, the separation of the peaks was incor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910180119

    authors: Xu AS,Potts JR,Kuchel PW

    更新日期:1991-03-01 00:00:00

  • Fully automated patellofemoral MRI segmentation using holistically nested networks: Implications for evaluating patellofemoral osteoarthritis, pain, injury, pathology, and adolescent development.

    abstract:PURPOSE:Our clinical understanding of the relationship between 3D bone morphology and knee osteoarthritis, as well as our ability to investigate potential causative factors of osteoarthritis, has been hampered by the time-intensive nature of manually segmenting bone from MR images. Thus, we aim to develop and validate ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27920

    authors: Cheng R,Alexandridi NA,Smith RM,Shen A,Gandler W,McCreedy E,McAuliffe MJ,Sheehan FT

    更新日期:2020-01-01 00:00:00

  • Partial-volume effect on ischemic tissue-fate delineation using quantitative perfusion and diffusion imaging on a rat stroke model.

    abstract::Partial-volume effects (PVE) in stroke imaging could hinder proper delineation of normal, ischemic, and at-risk tissues. Cerebral-blood-flow (CBF) and apparent diffusion coefficient (ADC) were measured at high and low resolution (HR = 128 x 128, LR = 64 x 64) in focal ischemia in rats during the acute phase. The data ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20299

    authors: Ren H,Shen Q,Bardutzky J,Fisher M,Duong TQ

    更新日期:2004-12-01 00:00:00

  • 2D multislice and 3D MRI sequences are often equally sensitive.

    abstract::A simple theoretical model was developed to compare the sensitivities (i.e., signal-to-noise ratios per unit imaging time) of two-dimensional (2D) multislice and 3D imaging sequences. The model shows that the sensitivities of 3D and 2D multislice MRI sequences are usually similar. Sensitivities are identical in T2-wei...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199904)41:4<824::aid-mrm23

    authors: Johnson G,Wadghiri YZ,Turnbull DH

    更新日期:1999-04-01 00:00:00

  • Intracellular redox state revealed by in vivo (31) P MRS measurement of NAD(+) and NADH contents in brains.

    abstract:PURPOSE:Nicotinamide adenine dinucleotide (NAD), in oxidized (NAD(+) ) or reduced (NADH) form, plays key roles in cellular metabolism. Intracellular NAD(+) /NADH ratio represents the cellular redox state; however, it is difficult to measure in vivo. We report here a novel in vivo (31) P MRS method for noninvasive measu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24859

    authors: Lu M,Zhu XH,Zhang Y,Chen W

    更新日期:2014-06-01 00:00:00

  • Magnesium and pH imaging of the human brain at 3.0 Tesla.

    abstract::Multislice, two-dimensional phosphorus 31 spectroscopic imaging (SI) of human brain was performed in 15 normal volunteers on a 3-Tesla magnetic resonance system. Images of free magnesium concentrations and pH as well as phosphoesters, inorganic phosphate, phosphocreatine, and adenosine triphosphate (ATP), were calcula...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199902)41:2<400::aid-mrm26

    authors: Barker PB,Butterworth EJ,Boska MD,Nelson J,Welch KM

    更新日期:1999-02-01 00:00:00

  • A one-step biomarker quantification methodology for DCE-MRI of adnexal masses: Capturing kinetic pattern from early to late enhancement.

    abstract:PURPOSE:To develop a one-step quantification approach that accounts for joint preprocessing and quantification of whole-range kinetics (early and late-phase washout) of dynamic contrast-enhanced (DCE) MRI of indeterminate adnexal masses. METHODS:Preoperative DCE-MRI of 43 (24 benign, 19 malignant) sonographically inde...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26743

    authors: Fathi Kazerooni A,Nabil M,Haghighat Khah H,Parviz S,Gity M,Saligheh Rad H

    更新日期:2018-02-01 00:00:00

  • Rapid in vivo musculoskeletal MR with parallel imaging at 7T.

    abstract::The purpose of this work was to implement autocalibrating GRAPPA-based parallel imaging (PI) for in vivo high-resolution (HR) MRI of cartilage and trabecular bone micro-architecture at 7T and to evaluate its performance based on comparison of MR-derived morphology metrics between accelerated and conventional images an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21455

    authors: Banerjee S,Krug R,Carballido-Gamio J,Kelley DA,Xu D,Vigneron DB,Majumdar S

    更新日期:2008-03-01 00:00:00

  • Fast, three-dimensional free-breathing MR imaging of myocardial infarction: a feasibility study.

    abstract::Imaging delayed hyperenhancement of myocardial infarction is most commonly performed using an inversion recovery (IR) prepared 2D breathhold segmented k-space gradient echo (FGRE) sequence. Since only one slice is acquired per breathhold in this technique, 12-16 successive breathholds are required for complete anatomi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20061

    authors: Saranathan M,Rochitte CE,Foo TK

    更新日期:2004-05-01 00:00:00

  • Estimating T1 from multichannel variable flip angle SPGR sequences.

    abstract::Quantitative estimation of T1 is a challenging but important task inherent to many clinical applications. The most commonly used paradigm for estimating T1 in vivo involves performing a sequence of spoiled gradient-recalled echo acquisitions at different flip angles, followed by fitting of an exponential model to the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24401

    authors: Trzasko JD,Mostardi PM,Riederer SJ,Manduca A

    更新日期:2013-06-01 00:00:00

  • Infimal convolution of total generalized variation functionals for dynamic MRI.

    abstract:PURPOSE:To accelerate dynamic MR applications using infimal convolution of total generalized variation functionals (ICTGV) as spatio-temporal regularization for image reconstruction. THEORY AND METHODS:ICTGV comprises a new image prior tailored to dynamic data that achieves regularization via optimal local balancing b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26352

    authors: Schloegl M,Holler M,Schwarzl A,Bredies K,Stollberger R

    更新日期:2017-07-01 00:00:00

  • Accelerated MR parameter mapping with low-rank and sparsity constraints.

    abstract:PURPOSE:To enable accurate magnetic resonance (MR) parameter mapping with accelerated data acquisition, utilizing recent advances in constrained imaging with sparse sampling. THEORY AND METHODS:A new constrained reconstruction method based on low-rank and sparsity constraints is proposed to accelerate MR parameter map...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25421

    authors: Zhao B,Lu W,Hitchens TK,Lam F,Ho C,Liang ZP

    更新日期:2015-08-01 00:00:00

  • Localized 7Li MR spectroscopy and spin relaxation in rat brain in vivo.

    abstract::Localized 7Li MR point-resolved spectroscopy (PRESS) was developed as a technique to measure lithium (Li) concentration in rat brain in vivo. Localized 7Li spectra could be obtained at 4.7 T in a 0.7-ml voxel in rat brain over the entire therapeutic range of serum Li for humans. Localized 7Li spin-lattice (T1) and spi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20112

    authors: Komoroski RA,Pearce JM

    更新日期:2004-07-01 00:00:00

  • Three-dimensional water/fat separation and T2* estimation based on whole-image optimization--application in breathhold liver imaging at 1.5 T.

    abstract::The chemical shift of water and fat resonances in proton MRI allows separation of water and fat signal from chemical shift encoded data. This work describes an automatic method that produces separate water and fat images as well as quantitative maps of fat signal fraction and T2* from complex multiecho gradient-recall...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23185

    authors: Berglund J,Kullberg J

    更新日期:2012-06-01 00:00:00