2D multislice and 3D MRI sequences are often equally sensitive.

Abstract:

:A simple theoretical model was developed to compare the sensitivities (i.e., signal-to-noise ratios per unit imaging time) of two-dimensional (2D) multislice and 3D imaging sequences. The model shows that the sensitivities of 3D and 2D multislice MRI sequences are usually similar. Sensitivities are identical in T2-weighted sequences when the T(R)s of the two sequences are the same. In T1-weighted gradient-echo sequences, sensitivities are very similar when Ernst angle excitation is used and the T(R) of the 2D sequence is less than T1. The predictions of the model are confirmed in phantom and animal experiments.

journal_name

Magn Reson Med

authors

Johnson G,Wadghiri YZ,Turnbull DH

doi

10.1002/(sici)1522-2594(199904)41:4<824::aid-mrm23

subject

Has Abstract

pub_date

1999-04-01 00:00:00

pages

824-8

issue

4

eissn

0740-3194

issn

1522-2594

pii

10.1002/(SICI)1522-2594(199904)41:4<824::AID-MRM23

journal_volume

41

pub_type

杂志文章
  • Anisotropic and restricted diffusion of water in the sciatic nerve: A (2)H double-quantum-filtered NMR study.

    abstract::The signals of water in the different compartments of rat sciatic nerve are resolved in the (2)H double-quantum-filtered NMR spectrum, due to their different quadrupolar splittings and relaxation rates. This resolution allowed the independent measurement of the water diffusion coefficients in the different compartment...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199909)42:3<461::aid-mrm8>

    authors: Seo Y,Shinar H,Morita Y,Navon G

    更新日期:1999-09-01 00:00:00

  • A framework for optimization-based design of motion encoding in magnetic resonance elastography.

    abstract:PURPOSE:In conventional three-dimensional magnetic resonance elastography, motion encoding gradients (MEGs) synchronized to a mechanical excitation are applied separately in each direction to encode tissue displacement generated by the corresponding waves. This requires long acquisition times that introduce errors due ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25280

    authors: Nir G,Sahebjavaher RS,Sinkus R,Salcudean SE

    更新日期:2015-04-01 00:00:00

  • Quantitative assessment of improved homogeneity using higher-order shims for spectroscopic imaging of the brain.

    abstract::Magnetic field homogeneity is of major concern for in vivo spectroscopy, and with the increased use of volumetric chemical shift imaging (CSI) techniques, the ability to shim over a large volume of tissue is now one of the primary limiting constraints in performing these studies. In vivo shimming is routinely performe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400307

    authors: Spielman DM,Adalsteinsson E,Lim KO

    更新日期:1998-09-01 00:00:00

  • Whole-body continuously moving table fat-water MRI with dynamic B0 shimming at 3 Tesla.

    abstract:PURPOSE:The purpose of this work was to develop a rapid and robust whole-body fat-water MRI (FWMRI) method using a continuously moving table (CMT) with dynamic field corrections at 3 Tesla. METHODS:CMT FWMRI was developed at 3 Tesla with a multiecho golden angle (GA) radial trajectory and dynamic B0 field shimming. Wh...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25848

    authors: Sengupta S,Smith DS,Gifford A,Welch EB

    更新日期:2016-07-01 00:00:00

  • Experimental encephalomyelitis modulates inositol and taurine in the spinal cord of Biozzi mice.

    abstract::In this high resolution magnetic resonance spectroscopic study of experimental allergic encephalomyelitis (EAE) and Semliki Forest virus (SFV) infection of the Biozzi AB/H mouse, marked increases in the initially low levels of N-trimethyl compounds in the spinal cord were observed during probable demyelinating episode...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320603

    authors: Preece NE,Amor S,Baker D,Gadian DG,O'Neill JK,Urenjak J

    更新日期:1994-12-01 00:00:00

  • NMR visibility studies of N-delta proton of proximal histidine in deoxyhemoglobin in lysed and intact red cells.

    abstract::Recent in vivo 1H MRS studies of muscle oxygen levels by means of myoglobin (Mb) oxygenation have necessitated an investigation of the possible contamination from deoxy-hemoglobin (Hb). To determine the contribution of Hb in these NMR measurements, we studied the NMR visibility of histidyl N-delta proton of Hb in lyse...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300616

    authors: Wang DJ,Nioka S,Wang Z,Leigh JS,Chance B

    更新日期:1993-12-01 00:00:00

  • Effects of polar sampling in k-space.

    abstract::Magnetic resonance imaging allows numerous k-space sampling schemes such as cartesian, polar, spherical, and other non-rectilinear trajectories. Non-rectilinear MR acquisitions permit fast scan times and can suppress motion artifacts. Still, these sampling schemes may adversely affect the image characteristics due to ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360617

    authors: Lauzon ML,Rutt BK

    更新日期:1996-12-01 00:00:00

  • Regional comparison of tumor vascularity and permeability parameters measured by albumin-Gd-DTPA and Gd-DTPA.

    abstract::Sequential albumin-Gd-DTPA and Gd-DTPA dynamic enhancement studies were performed in an animal tumor model for the comparison of regional vascularity and permeability parameters measured by these two different sizes of contrast agents. The early albumin-Gd-DTPA enhancement arises from the vascular compartment, and the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340318

    authors: Su MY,Najafi AA,Nalcioglu O

    更新日期:1995-09-01 00:00:00

  • Rapid T2 estimation with phase-cycled variable nutation steady-state free precession.

    abstract::Variable nutation SSFP (DESPOT2) permits rapid, high-resolution determination of the transverse (T2) relaxation constant. A limitation of DESPOT2, however, is the presence of T2 voids due to off-resonance banding artifacts associated with SSFP images. These artifacts typically occur in images acquired with long repeti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20159

    authors: Deoni SC,Ward HA,Peters TM,Rutt BK

    更新日期:2004-08-01 00:00:00

  • Maximum entropy and 2DFT NMR images.

    abstract::A comparison between contrast and signal-to-noise ratio (SNR), as obtained by both maximum entropy (ME) and 2DFT reconstruction, is reported for NMR images. Our results show that in the ME elaboration the contrast and SNR are generally increased with respect to the 2DFT elaboration. The magnitude of such an increase d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910080310

    authors: De Simone BC,De Luca F,Maraviglia B

    更新日期:1988-11-01 00:00:00

  • Relationships between tissue microstructure and the diffusion tensor in simulated skeletal muscle.

    abstract:PURPOSE:To establish a series of relationships defining how muscle microstructure and diffusion tensor imaging (DTI) are related. METHODS:The relationship among key microstructural features of skeletal muscle (fiber size, fibrosis, edema, and permeability) and the diffusion tensor were systematically simulated over ph...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26993

    authors: Berry DB,Regner B,Galinsky V,Ward SR,Frank LR

    更新日期:2018-07-01 00:00:00

  • Dissolved hyperpolarized xenon-129 MRI in human kidneys.

    abstract:PURPOSE:To assess the feasibility of using dissolved hyperpolarized xenon-129 (129 Xe) MRI to study renal physiology in humans at 3 T. METHODS:Using a flexible transceiver RF coil, dynamic and spatially resolved 129 Xe spectroscopy was performed in the abdomen after inhalation of hyperpolarized 129 Xe gas with 3 healt...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27923

    authors: Chacon-Caldera J,Maunder A,Rao M,Norquay G,Rodgers OI,Clemence M,Puddu C,Schad LR,Wild JM

    更新日期:2020-01-01 00:00:00

  • Intracellular and extracellular spaces and the direct quantification of molar intracellular concentrations of phosphorus metabolites in the isolated rat heart using 31P NMR spectroscopy and phosphonate markers.

    abstract::To quantify metabolite and cation concentrations using NMR spectroscopy, the volumes of intracellular and extracellular spaces must be known. We describe a simple 31P NMR spectroscopic method that employs dimethyl methylphosphonate (DMMP) as a marker of total water space and phenylphosphonate (PPA) as a marker of extr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320206

    authors: Clarke K,Anderson RE,Nédélec JF,Foster DO,Ally A

    更新日期:1994-08-01 00:00:00

  • 1H NMR relaxation measurements of human tissues in situ by spatially resolved spectroscopy.

    abstract::Spatially resolved spectroscopy (SPARS) is a method for obtaining high-resolution NMR spectra of well-defined volumes of human tissues in situ. This method was combined with the Carr-Purcell-Meiboom-Gill multiple-echo sequence for T2, and with inversion recovery for T1 relaxation measurements. Relaxation times obtaine...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040504

    authors: Luyten PR,Anderson CM,den Hollander JA

    更新日期:1987-05-01 00:00:00

  • Arterial spin labeling perfusion fMRI with very low task frequency.

    abstract::Functional magnetic resonance imaging (fMRI) has become the most widely used modality for visualizing regional brain activation in response to sensorimotor or cognitive tasks. While the majority of fMRI studies have used blood oxygenation level-dependent (BOLD) contrast as a marker for neural activation, baseline drif...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10437

    authors: Wang J,Aguirre GK,Kimberg DY,Roc AC,Li L,Detre JA

    更新日期:2003-05-01 00:00:00

  • Parallel transmit capability of various RF transmit elements and arrays at 7T MRI.

    abstract:PURPOSE:In this work, 22 configurations for remote radiofrequency (RF) coil arrays consisting of different transmit element designs for 7 Tesla (T) ultrahigh-field MRI are compared by numerical simulations. METHODS:Investigated transmit RF element types are rectangular loops, micro striplines, micro striplines with me...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26704

    authors: Rietsch SHG,Orzada S,Bitz AK,Gratz M,Ladd ME,Quick HH

    更新日期:2018-02-01 00:00:00

  • Characterization of perfluorocarbon relaxation times and their influence on the optimization of fluorine-19 MRI at 3 tesla.

    abstract:PURPOSE:To characterize and optimize 19 F MRI for different perfluorocarbons (PFCs) at 3T and quantify the loss of acquisition efficiency as a function of different temperature and cellular conditions. METHODS:The T1 and T2 relaxation times of the commonly used PFCs perfluoropolyether (PFPE), perfluoro-15-crown-5-ethe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26317

    authors: Colotti R,Bastiaansen JAM,Wilson A,Flögel U,Gonzales C,Schwitter J,Stuber M,van Heeswijk RB

    更新日期:2017-06-01 00:00:00

  • Porous medium 3D flow simulation of contrast media washout in cardiac MRI reflects myocardial injury.

    abstract:PURPOSE:Myocardial blood-flow simulation based on laws of fluid mechanics is a valuable tool for understanding tissue behavior. Our aim is to evaluate the ability of a porous-media flow model approach to reflect disturbed washout of contrast media (CM) from the myocardium as observed by cardiovascular MR. METHODS:A co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27756

    authors: Riazy L,Schaeffter T,Olbrich M,Schueler J,von Knobelsdorff-Brenkenhoff F,Niendorf T,Schulz-Menger J

    更新日期:2019-08-01 00:00:00

  • Markerless high-frequency prospective motion correction for neuroanatomical MRI.

    abstract:PURPOSE:To integrate markerless head motion tracking with prospectively corrected neuroanatomical MRI sequences and to investigate high-frequency motion correction during imaging echo trains. METHODS:A commercial 3D surface tracking system, which estimates head motion by registering point cloud reconstructions of the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27705

    authors: Frost R,Wighton P,Karahanoğlu FI,Robertson RL,Grant PE,Fischl B,Tisdall MD,van der Kouwe A

    更新日期:2019-07-01 00:00:00

  • Theory of heterogeneous relaxation in compartmentalized tissues.

    abstract::A new model of compartmentalized relaxation--that which occurs for spins (protons) exchanging between compartments of different relaxation rates--is presented. This model generalizes previous ones by allowing spatially dependent relaxation within compartments. Solutions for the diffusion-Bloch equations are found via ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370507

    authors: Barsky D,Pütz B,Schulten K

    更新日期:1997-05-01 00:00:00

  • 3D coronary artery imaging with phase reordering for improved scan efficiency.

    abstract::Three-dimensional (3D) coronary imaging has the potential to overcome problems resulting from vessel tortuosity and to reduce partial volume effects. With these techniques, however, acquisition times are long and respiratory motion artifacts problematical. This work describes the development of a method that applies p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199903)41:3<555::aid-mrm19

    authors: Jhooti P,Keegan J,Gatehouse PD,Collins S,Rowe A,Taylor AM,Firmin DN

    更新日期:1999-03-01 00:00:00

  • Water in tendon: orientational analysis of the free induction decay.

    abstract::The orientation dependence of the free induction decay (FID) of 1H NMR water signal in ex vivo bovine digital flexor tendon at the native level of hydration is reported. Residual dipolar coupling due to the overall tissue anisotropy produces a 6:1 change in the signal intensity as an angle between the long axis of a s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20540

    authors: Krasnosselskaia LV,Fullerton GD,Dodd SJ,Cameron IL

    更新日期:2005-08-01 00:00:00

  • Mathematical optimization of contrast concentration for T1-weighted spoiled gradient echo imaging.

    abstract:PURPOSE:To develop and validate closed form mathematical expressions that predict the optimal contrast agent concentration for the maximum T1-weighted spoiled gradient echo (SGRE) signal. THEORY AND METHODS:Gadolinium and iron-based contrast agents can have significant transverse relaxivity that leads to signal dropou...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25744

    authors: Reeder SB,Smith MR,Hernando D

    更新日期:2016-04-01 00:00:00

  • Constrained estimation of the arterial input function for myocardial perfusion cardiovascular magnetic resonance.

    abstract::Accurate quantification of myocardial perfusion remains challenging due to saturation of the arterial input function at high contrast concentrations. A method for estimating the arterial input function directly from tissue curves in the myocardium that avoids these difficulties is presented. In this constrained altern...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22809

    authors: Fluckiger JU,Schabel MC,DiBella EV

    更新日期:2011-08-01 00:00:00

  • Dynamic liver imaging with iron oxide agents: effects of size and biodistribution on contrast.

    abstract::In vivo effective relaxation rates in normal rat liver were evaluated for four dextran coated iron oxide agents: monocrystalline iron oxide nanocolloid (MION) with a mean particle diameter of 3.9 nm, a polycrystalline agent (PION) with a larger mean diameter of 12 nm, and these two agents labeled with the asialofetuin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370613

    authors: Mandeville JB,Moore J,Chesler DA,Garrido L,Weissleder R,Weisskoff RM

    更新日期:1997-06-01 00:00:00

  • Mean magnetic susceptibility regularized susceptibility tensor imaging (MMSR-STI) for estimating orientations of white matter fibers in human brain.

    abstract:PURPOSE:An increasing number of studies show that magnetic susceptibility in white matter fibers is anisotropic and may be described by a tensor. However, the limited head rotation possible for in vivo human studies leads to an ill-conditioned inverse problem in susceptibility tensor imaging (STI). Here we suggest the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25322

    authors: Li X,van Zijl PC

    更新日期:2014-09-01 00:00:00

  • Transverse relaxation time constants of the five major metabolites in human brain measured in vivo using LASER and PRESS at 3 T.

    abstract:PURPOSE:The goal of this study was to measure and compare the apparent transverse relaxation time constants (T2 ) of five intracellular metabolites using localization by adiabatic selective refocusing (LASER) and point-resolved spectroscopy (PRESS) sequences in the human brain at 3 T. METHODS:Five healthy subjects wer...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26826

    authors: Deelchand DK,Auerbach EJ,Kobayashi N,Marjańska M

    更新日期:2018-03-01 00:00:00

  • Toward fully automatic estimation of in vivo 31P spectra.

    abstract::Fitting a model to an experimental spectrum is a difficult nonlinear estimation problem. The solution presented here is to start an iterative search procedure sufficiently close to the optimal model parameter set. This is achieved by providing tissue-dependent a priori peak information and by a novel correlation metho...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910210206

    authors: Burger C,McKinnon G,Buchli R,Boesiger P

    更新日期:1991-10-01 00:00:00

  • Total liver fat quantification using three-dimensional respiratory self-navigated MRI sequence.

    abstract:PURPOSE:MRI can produce quantitative liver fat fraction (FF) maps noninvasively, which can help to improve diagnoses of fatty liver diseases. However, most sequences acquire several two-dimensional (2D) slices during one or more breath-holds, which may be difficult for patients with limited breath-holding capacity. A w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26028

    authors: Arboleda C,Aguirre-Reyes D,García MP,Tejos C,Muñoz L,Miquel JF,Irarrazaval P,Andia ME,Uribe S

    更新日期:2016-11-01 00:00:00

  • Simultaneous multislice multiband parallel radiofrequency excitation with independent slice-specific transmit B1 homogenization.

    abstract:PURPOSE:To develop a new parallel transmit (pTx) pulse design for simultaneous multiband (MB) excitation in order to tackle simultaneously the problems of transmit B1 (B1+) inhomogeneity and total radiofrequency (RF) power, so as to allow for optimal RF excitation when using MB pulses for slice acceleration for high an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24828

    authors: Wu X,Schmitter S,Auerbach EJ,Moeller S,Uğurbil K,Van de Moortele PF

    更新日期:2013-09-01 00:00:00