Abstract:
:A new model of compartmentalized relaxation--that which occurs for spins (protons) exchanging between compartments of different relaxation rates--is presented. This model generalizes previous ones by allowing spatially dependent relaxation within compartments. Solutions for the diffusion-Bloch equations are found via an efficient numerical technique known as the generalized moment expansion, and they agree well with the solutions to the standard two-site exchange equations (TSEE) for many typical situations. Specific models are developed for liposomes, red blood cells, capillaries, and arteries with respect to applied contrast agents. A parameter derived from tissue characteristics is introduced to predict the nature of the solutions. A new method is proposed for using contrast agents to detect capillaries, which exploits their high surface-to-volume ratio relative to the other elements of the vasculature.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Barsky D,Pütz B,Schulten Kdoi
10.1002/mrm.1910370507subject
Has Abstractpub_date
1997-05-01 00:00:00pages
666-75issue
5eissn
0740-3194issn
1522-2594journal_volume
37pub_type
杂志文章abstract::Radiofrequency (RF) -spoiled gradient echo sequences were developed with the aim to produce images with T(1) weighted contrast within short acquisition time. Over the past two decades, this type of sequence has proven to be a robust technique and represents a reliable workhorse in clinical MRI. This study presents an ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21614
更新日期:2008-07-01 00:00:00
abstract::We describe a versatile NMR probe that is designed for a variety of in vivo spectroscopic studies on small animals in vertical wide-bore magnets. Replaceable brackets enable the coils to be exchanged readily in order to observe 1H, 13C, 31P, and other nuclei, and to carry out double-resonance experiments. Two solenoid...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910060102
更新日期:1988-01-01 00:00:00
abstract::In this study undersampled projection reconstruction (PR) was used for rapid catheter imaging in the heart, employing steady-state free precession (SSFP) contrast. Active catheters and phased-array coils were used for combined imaging of anatomy and catheter position in swine. Real-time imaging of catheter position wa...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10390
更新日期:2003-02-01 00:00:00
abstract::Half k-space gradient-recalled echo-planar imaging (GR-EPI) is discussed in detail. T2* decay during full k-space GR-EPI gives rise to unequal weighting of the lines of k-space, loss of signal intensity at the center of k-space, and a point-spread function that limits resolution. In addition, the long readout time for...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910400517
更新日期:1998-11-01 00:00:00
abstract:PURPOSE:The clinical potential of the diffusion imaging-based analysis of fine brain structures such as fornix or cingulum is high due to the central role of these structures in psychiatric diseases. However, the quantification of diffusion parameters in fine structures is especially prone to partial volume effects (PV...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24774
更新日期:2014-03-01 00:00:00
abstract::Healthy human brain diffusion anisotropy maps derived from standard spin echo diffusion tensor imaging (DTI) were compared with those using fluid-attenuated inversion recovery (FLAIR) preparation prior to DTI to null the signal from cerebrospinal fluid (CSF). Consistent comparisons entailed development of DTI postproc...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10204
更新日期:2002-08-01 00:00:00
abstract::A simple iterative algorithm, termed deconvolution-interpolation gridding (DING), is presented to address the problem of reconstructing images from arbitrarily-sampled k-space. The new algorithm solves a sparse system of linear equations that is equivalent to a deconvolution of the k-space with a small window. The dec...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21095
更新日期:2006-12-01 00:00:00
abstract::The assessment of myocardial fibrosis and extracellular volume requires accurate estimation of myocardial T1 s. While image acquisition using the modified Look-Locker inversion recovery technique is clinically feasible for myocardial T1 mapping, respiratory motion can limit its applicability. Moreover, the conventiona...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24385
更新日期:2013-05-01 00:00:00
abstract:PURPOSE:The purpose of this work was to develop a rapid and robust whole-body fat-water MRI (FWMRI) method using a continuously moving table (CMT) with dynamic field corrections at 3 Tesla. METHODS:CMT FWMRI was developed at 3 Tesla with a multiecho golden angle (GA) radial trajectory and dynamic B0 field shimming. Wh...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25848
更新日期:2016-07-01 00:00:00
abstract:PURPOSE:Irreversible electroporation (IRE) is a nonthermal tissue ablation technique that represents a promising treatment option for unresectable liver tumors, but the effectively treated zone cannot be reliably predicted. We investigate the potential benefit of transcatheter intra-arterial perfusion (TRIP) -MRI for t...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28104
更新日期:2020-07-01 00:00:00
abstract::A modular, user-friendly computer simulation of NMR imaging was created for the DEC VAX computer. This simulation is novel in that complex imaging phenomena, such as chemical shifts and flow, may be easily studied. Other features include spin warp and backprojection imaging, movie generation, and simulation of image c...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910030302
更新日期:1986-06-01 00:00:00
abstract:PURPOSE:We propose a new acquisition to minimize the per-excitation encoding duration and improve the imaging capability for short T2 * species. METHODS:In the proposed ramped hybrid encoding (RHE) technique, gradients are applied before the radiofrequency (RF) pulse as in pointwise encoding time reduction with radial...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25977
更新日期:2016-09-01 00:00:00
abstract::Some of the factors involved in the choice of field strength for NMR imaging are examined. The influences of relaxation times and chemical shift upon image quality and signal-to-noise ratio are highlighted, and power deposition is introduced as a significant factor which may limit the flexibility and information avail...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910030509
更新日期:1986-10-01 00:00:00
abstract::An effective shield for the dc fringing fields produced by a large-bore, high field magnet intended for imaging and in vivo spectroscopy is presented. While limiting the extent of fringe fields, the shield has little effect on the homogeneity of the central field of the magnet. The effect of institutional safety polic...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910020506
更新日期:1985-10-01 00:00:00
abstract::A novel ultra-rapid gradient echo (URGE) NMR imaging technique is introduced, which is capable of continuous high resolution 3D scanning while neither subject to fast gradient switching nor excessive RF power deposition. Sampling free induction decays instead of creating spin echoes enables maintaining a workable stea...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910330123
更新日期:1995-01-01 00:00:00
abstract::Continuously moving table (CMT) MRI is a new method that is capable of generating 3D, seamless, large field-of-view (FOV) images by acquiring readouts along the patient superior-inferior axis as the subject is translated through the scanner. For applications that require artifact-free images, such as arterial-phase co...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20848
更新日期:2006-05-01 00:00:00
abstract::Manganese-enhanced MRI has previously been used for visualization of brain architecture and functional mapping of neural pathways. The present work investigated the potential of manganese-enhanced MRI for noninvasive imaging of salivary glands in living subjects. Marked shortening of T(1) was observed in salivary glan...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22452
更新日期:2010-09-01 00:00:00
abstract:PURPOSE:To evaluate the feasibility of an improved motion and flow robust methodology for imaging the pulmonary vasculature using non-contrast-enhanced, free-breathing, golden-angle radial MRI. METHODS:Healthy volunteers (n = 10, age 46 ± 11 years, 50% female) and patients (n = 2, ages 27 and 84, both female) were ima...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27177
更新日期:2018-11-01 00:00:00
abstract:PURPOSE:For ultrahigh field (UHF) MRI, the expected local specific absorption rate (SAR) distribution is usually calculated by numerical simulations using a limited number of generic body models and adding a safety margin to take into account intersubject variability. Assessment of this variability with a large model d...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27518
更新日期:2019-03-01 00:00:00
abstract::Quantitative measurement of lung microstructure is of great significance in assessment of pulmonary disease, particularly in the earliest stages. The technique for MRI-based 3He lung morphometry was previously developed and validated for human lungs, and was recently extended to ex vivo mouse lungs. The technique yiel...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22737
更新日期:2011-03-01 00:00:00
abstract:PURPOSE:To test octafluorocyclobutane (OFCB) as an inhalation contrast agent for fluorine-19 MRI of the lung, and to compare the image quality of OFCB scans with perfluoropropane (PFP) scans THEORY AND METHODS: After normalizing for the number of signal averages, a theoretical comparison between the OFCB signal-to-nois...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28473
更新日期:2021-02-01 00:00:00
abstract::We have obtained high-field (11.7 Tesla), high-resolution carbon-13 solid-state "magic-angle" sample-spinning nuclear magnetic resonance (NMR) spectra of a variety of phospholipids, sphingolipids, myelin and white matter samples, resolving and assigning over 40 resonances in the spectra of human and bovine myelin. The...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910290204
更新日期:1993-02-01 00:00:00
abstract::A type of local coil (or surface coil) for magnetic resonance imaging and spectroscopy is described in which two circular loops of the same diameter are disposed axially with respect to each other and in which counter rotating currents (CRC) are supported in the two loops. This type of coil has been used for localized...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910030412
更新日期:1986-08-01 00:00:00
abstract::Lower extremity peripheral vein bypass grafts (LE-PVBG) imaged with high-resolution black blood three-dimensional (3D) inner-volume (IV) fast spin echo (FSE) MRI at 1.5 Tesla possess a two-layer appearance in T1W images while only the inner layer appears visible in the corresponding T2W images. This study quantifies t...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22037
更新日期:2009-09-01 00:00:00
abstract::Nonlinear feedback interactions have been shown to amplify contrast due to small differences in resonance frequency arising from microscopic susceptibility variations. Determining whether the selectivity of feedback-based contrast enhancement for small resonance frequency variations remains valid even in the presence ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21584
更新日期:2009-04-01 00:00:00
abstract:PURPOSE:Reliable monitoring of tissue nicotinamide adenine dinucleotide (NAD+ ) concentration may provide insights on its roles in normal and pathological aging. In the present study, we report a 1 H MRS pulse sequence for the in vivo, localized 1 H MRS detection of NAD+ from the human brain. METHODS:Studies were carr...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27971
更新日期:2020-03-01 00:00:00
abstract::The pulse wave velocity (PWV) of aortic blood flow is considered a surrogate for aortic compliance. A new method using phase-contrast (PC)-MRI is presented whereby the spatial and temporal profiles of axial velocity along the descending aorta can be analyzed. Seventeen young healthy volunteers (the YH group), six olde...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21034
更新日期:2006-10-01 00:00:00
abstract::In this high resolution magnetic resonance spectroscopic study of experimental allergic encephalomyelitis (EAE) and Semliki Forest virus (SFV) infection of the Biozzi AB/H mouse, marked increases in the initially low levels of N-trimethyl compounds in the spinal cord were observed during probable demyelinating episode...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910320603
更新日期:1994-12-01 00:00:00
abstract::The application of T1 rho an an alternative contrast parameter in high-field magnetic resonance histology (MRH) has been investigated. Spectroscopic measurements of T1 rho were performed on 5.75% agar and 1.0 mM MnCI2 phantoms at 9.4 T to validate the accuracy of the imaging measurements. Image studies were performed ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910350520
更新日期:1996-05-01 00:00:00
abstract::Respiratory motion and pulsatile blood flow can generate artifacts in morphological and functional lung imaging. Total acquisition time, and thus the achievable signal to noise ratio, is limited when performing breath-hold and/or electrocardiogram-triggered imaging. To overcome these limitations, imaging during free r...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21846
更新日期:2009-03-01 00:00:00