T1 rho relaxation and its application to MR histology.

Abstract:

:The application of T1 rho an an alternative contrast parameter in high-field magnetic resonance histology (MRH) has been investigated. Spectroscopic measurements of T1 rho were performed on 5.75% agar and 1.0 mM MnCI2 phantoms at 9.4 T to validate the accuracy of the imaging measurements. Image studies were performed at 2.0 and 9.4 T on perfusion-fixed 17.5-day-old mouse embryos. T1, T2, and T1 rho relaxation times were calculated for the phantoms and muscle, diencephalon, and liver tissues. The 5.75% agar phantom and all tissues showed T1 rho dispersion with B1L, whereas the 1.0 mM MnCI2 phantom showed no significant B1L dependence. T1 rho dispersion with B(O) was observed arising from the effects of diffusion through susceptibility-induced gradients. T1 rho shows promise as a contrast parameter in high-field MRH because it is capable of producing T2-like contrast without the susceptibility artifacts associated with T2-weighted images.

journal_name

Magn Reson Med

authors

Engelhardt RT,Johnson GA

doi

10.1002/mrm.1910350520

subject

Has Abstract

pub_date

1996-05-01 00:00:00

pages

781-6

issue

5

eissn

0740-3194

issn

1522-2594

journal_volume

35

pub_type

杂志文章
  • Initial investigation of a novel noninvasive weight loss therapy using MRI-Guided high intensity focused ultrasound (MR-HIFU) of visceral fat.

    abstract:PURPOSE:MRI-guided high intensity focused ultrasound (MR-HIFU) allows noninvasive heating of deep tissues. Specifically targeting visceral fat deposits with MR-HIFU could offer an effective therapy for reversing the development of obesity, diabetes, and metabolic syndrome. METHODS:Overweight rats received either MR-HI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25883

    authors: Winter PM,Lanier M,Partanen A,Dumoulin C

    更新日期:2016-07-01 00:00:00

  • An analytical solution for the SSFP signal in MRI.

    abstract::Among previous analyses of the steady-state free-precession (SSFP) signal in rapid MRI, one treatment resulted in equations that require the evaluation of infinite binomial series. Here, an analytical solution is derived by a transformation into the power series expansion of the derivative of the inverse sine function...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10410

    authors: Hänicke W,Vogel HU

    更新日期:2003-04-01 00:00:00

  • In vivo imaging of extracellular pH using 1H MRSI.

    abstract::Tumor pH is physiologically important since it influences a number of processes relevant to tumorigenesis and therapy. Hence, knowledge of localized pH within tumors would contribute to understanding these processes. The destructiveness, poor spatial resolution, and poor signal-to-noise ratio (SNR) of current technolo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199904)41:4<743::aid-mrm13

    authors: van Sluis R,Bhujwalla ZM,Raghunand N,Ballesteros P,Alvarez J,Cerdán S,Galons JP,Gillies RJ

    更新日期:1999-04-01 00:00:00

  • Multislice perfusion and perfusion territory imaging in humans with separate label and image coils.

    abstract::An arterial spin labeling technique using separate RF labeling and imaging coils was used to obtain multislice perfusion images of the human brain at 3 T. Continuous RF irradiation at a peak power of 0.3 W was applied to the carotid arteries to adiabatically invert spins. Labeling was achieved without producing magnet...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199906)41:6<1093::aid-mrm4

    authors: Zaharchuk G,Ledden PJ,Kwong KK,Reese TG,Rosen BR,Wald LL

    更新日期:1999-06-01 00:00:00

  • Adaptive self-calibrating iterative GRAPPA reconstruction.

    abstract::Parallel magnetic resonance imaging in k-space such as generalized auto-calibrating partially parallel acquisition exploits spatial correlation among neighboring signals over multiple coils in calibration to estimate missing signals in reconstruction. It is often challenging to achieve accurate calibration information...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23188

    authors: Park S,Park J

    更新日期:2012-06-01 00:00:00

  • Characterizing the limits of MRI near metallic prostheses.

    abstract:PURPOSE:To characterize the fundamental limits of MRI near metallic implants on RF excitation, frequency encoding, and chemical shift-encoding water-fat separation. METHODS:Multicomponent three-dimensional (3D) digital models of a total hip and a total knee replacement were used to construct material-specific suscepti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25540

    authors: Smith MR,Artz NS,Wiens C,Hernando D,Reeder SB

    更新日期:2015-12-01 00:00:00

  • Interindividual reproducibility of glutamate quantification using 1.5-T proton magnetic resonance spectroscopy.

    abstract::The goal of this study was to measure the interindividual reproducibility of glutamate quantification in 1.5-T (1)H MRS of human brains. To determine the effective echo time (TE) for glutamate quantification, spectra from a phantom and 12 participants were obtained with TE = 30, 35, 40, and 144 ms (repetition time (TR...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20387

    authors: Jang DP,Lee JM,Lee E,Park S,Kim JJ,Namkoong K,Yoon KJ,Kim IY,Kim SI

    更新日期:2005-03-01 00:00:00

  • Fetal whole-heart 4D imaging using motion-corrected multi-planar real-time MRI.

    abstract:PURPOSE:To develop an MRI acquisition and reconstruction framework for volumetric cine visualization of the fetal heart and great vessels in the presence of maternal and fetal motion. METHODS:Four-dimensional (4D) depiction was achieved using a highly-accelerated multi-planar real-time balanced steady-state free prece...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27798

    authors: van Amerom JFP,Lloyd DFA,Deprez M,Price AN,Malik SJ,Pushparajah K,van Poppel MPM,Rutherford MA,Razavi R,Hajnal JV

    更新日期:2019-09-01 00:00:00

  • Steady state of echo-shifted sequences with radiofrequency phase cycling.

    abstract::Due to a delayed echo-formation, echo-shifted gradient echo sequences (ES-GRE) allow for an enhanced T(2)*-weighting at short repetition times. While they are in use with and without RF spoiling, analytical solutions are only known for the latter. The signal formation in the former could only be assessed in approximat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21010

    authors: Ganter C

    更新日期:2006-10-01 00:00:00

  • Single acquisition electrical property mapping based on relative coil sensitivities: A proof-of-concept demonstration.

    abstract:PURPOSE:All methods presented to date to map both conductivity and permittivity rely on multiple acquisitions to compute quantitatively the magnitude of radiofrequency transmit fields, B1+. In this work, we propose a method to compute both conductivity and permittivity based solely on relative receive coil sensitivitie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25399

    authors: Marques JP,Sodickson DK,Ipek O,Collins CM,Gruetter R

    更新日期:2015-07-01 00:00:00

  • A pitfall associated with determination of transverse relaxation times of the 31P NMR signals of ATP using the Hahn spin-echo.

    abstract::T2 measurements of 31P NMR signals of ATP using the Hahn 90 degrees-180 degrees spin-echo sequence imply difficulties whenever the 180 degrees pulse angle is not completely perfect. The reason for this finding is the crucial influence of the J-couplings of the ATP signals which result in intensity modulations and cons...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300122

    authors: Jung WI,Straubinger K,Bunse M,Widmaier S,Schick F,Küper K,Dietze G,Lutz O

    更新日期:1993-07-01 00:00:00

  • Localization errors in MR spectroscopic imaging due to the drift of the main magnetic field and their correction.

    abstract:PURPOSE:To analyze the effect of B0 field drift on multivoxel MR spectroscopic imaging and to propose an approach for its correction. THEORY AND METHODS:It is shown, both theoretically and in a phantom, that for ∼30 min acquisitions a linear B0 drift (∼0.1 ppm/h) will cause localization errors that can reach several v...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24536

    authors: Tal A,Gonen O

    更新日期:2013-10-01 00:00:00

  • Experimental encephalomyelitis modulates inositol and taurine in the spinal cord of Biozzi mice.

    abstract::In this high resolution magnetic resonance spectroscopic study of experimental allergic encephalomyelitis (EAE) and Semliki Forest virus (SFV) infection of the Biozzi AB/H mouse, marked increases in the initially low levels of N-trimethyl compounds in the spinal cord were observed during probable demyelinating episode...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320603

    authors: Preece NE,Amor S,Baker D,Gadian DG,O'Neill JK,Urenjak J

    更新日期:1994-12-01 00:00:00

  • Fe(III) distribution varies substantially within and between atherosclerotic plaques.

    abstract:PURPOSE:Vulnerable atherosclerotic plaques are structurally weak and prone to rupture, presumably due to local oxidative stress. Redox active iron is linked to oxidative stress and the aim of this study was to investigate the distribution of Fe(III) in carotid plaques and its relation to vulnerability for rupture. MET...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24687

    authors: Gustafsson H,Hallbeck M,Norell M,Lindgren M,Engström M,Rosén A,Zachrisson H

    更新日期:2014-02-01 00:00:00

  • Quantitative assessment of improved homogeneity using higher-order shims for spectroscopic imaging of the brain.

    abstract::Magnetic field homogeneity is of major concern for in vivo spectroscopy, and with the increased use of volumetric chemical shift imaging (CSI) techniques, the ability to shim over a large volume of tissue is now one of the primary limiting constraints in performing these studies. In vivo shimming is routinely performe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400307

    authors: Spielman DM,Adalsteinsson E,Lim KO

    更新日期:1998-09-01 00:00:00

  • Generalized matched filtering for time-resolved MR angiography of pulsatile flow.

    abstract::Generating flow-specific images (arteriograms, venograms) with optimal signal-to-noise ratios for time-resolved MR angiography is a conditional maximum problem, and its solutions are generalized matched filters. We have investigated six matched filters, corresponding to all possible combinations of three flow suppress...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300511

    authors: Wang Y,Weber DM,Korosec FR,Mistretta CA,Grist TM,Swan JS,Turski PA

    更新日期:1993-11-01 00:00:00

  • Correlation of spectroscopy and magnetization transfer imaging in the evaluation of demyelinating lesions and normal appearing white matter in multiple sclerosis.

    abstract::Magnetization transfer imaging (MT) and localized proton spectroscopy (1H-MRS) were utilized in the evaluation of lesions (high signal abnormalities on T2-weighted images) and normal-appearing white matter (NAWM) in multiple sclerosis (MS). Eleven patients with a clinical diagnosis of MS were independently evaluated w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320303

    authors: Hiehle JF Jr,Lenkinski RE,Grossman RI,Dousset V,Ramer KN,Schnall MD,Cohen JA,Gonzalez-Scarano F

    更新日期:1994-09-01 00:00:00

  • Continuously moving table MRI with golden angle radial sampling.

    abstract:PURPOSE:Continuously moving table (CMT) MRI is a high throughput technique that has multiple applications in whole-body imaging. In this work, CMT MRI based on golden angle (GA, 111.246° azimuthal step) radial sampling is developed at 3 Tesla (T), with the goal of increased flexibility in image reconstruction using arb...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25531

    authors: Sengupta S,Smith DS,Welch EB

    更新日期:2015-12-01 00:00:00

  • Variable density incoherent spatiotemporal acquisition (VISTA) for highly accelerated cardiac MRI.

    abstract:PURPOSE:For the application of compressive sensing to parallel MRI, Poisson disk sampling (PDS) has been shown to generate superior results compared with random sampling methods. However, due to its limited flexibility to incorporate additional constraints, PDS is not readily extendible to dynamic applications. Here, w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25507

    authors: Ahmad R,Xue H,Giri S,Ding Y,Craft J,Simonetti OP

    更新日期:2015-11-01 00:00:00

  • Transmit and receive RF fields determination from a single low-tip-angle gradient-echo scan by scaling of SVD data.

    abstract:PURPOSE:A new method, called Transmit and Receive Patterns from Low-Tip-angle gradient-Echo Images (TRIPLET), is described which simultaneously maps the B1+ and B1- fields of a transmit/receive radiofrequency coil array. The input data are low-tip-angle gradient-echo images, which can be acquired in a relatively short ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24912

    authors: Sbrizzi A,Raaijmakers AJ,Hoogduin H,Lagendijk JJ,Luijten PR,van den Berg CA

    更新日期:2014-07-01 00:00:00

  • Prospective real-time head motion correction using inductively coupled wireless NMR probes.

    abstract:PURPOSE:Head motion continues to be a major source of artifacts and data quality degradation in MRI. The goal of this work was to develop and demonstrate a novel technique for prospective, 6 degrees of freedom (6DOF) rigid body motion estimation and real-time motion correction using inductively coupled wireless nuclear...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25001

    authors: Sengupta S,Tadanki S,Gore JC,Welch EB

    更新日期:2014-10-01 00:00:00

  • A new approach to autocalibrated dynamic parallel imaging based on the Karhunen-Loeve transform: KL-TSENSE and KL-TGRAPPA.

    abstract::TSENSE and TGRAPPA are autocalibrated parallel imaging techniques that can improve the temporal resolution and/or spatial resolution in dynamic magnetic resonance imaging applications. In its original form, TSENSE uses temporal low-pass filtering of the undersampled frames to create the sensitivity map. TGRAPPA uses a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22766

    authors: Ding Y,Chung YC,Jekic M,Simonetti OP

    更新日期:2011-06-01 00:00:00

  • Transmit SENSE.

    abstract::The idea of using parallel imaging to shorten the acquisition time by the simultaneous use of multiple receive coils can be adapted for the parallel transmission of a spatially-selective multidimensional RF pulse. As in data acquisition, a multidimensional RF pulse follows a certain k-space trajectory. Shortening this...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10353

    authors: Katscher U,Börnert P,Leussler C,van den Brink JS

    更新日期:2003-01-01 00:00:00

  • Phosphonate-modified GdDTPA complexes. I. NMRD study of the solution behavior of new tissue-specific contrast agents.

    abstract::NMRD profiles, the magnetic field dependence of the water proton longitudinal relaxation rates, have been acquired for two new diphosphonate-modified GdDTPA complexes currently under evaluation as relaxation agents for the MRI detection of soft-tissue calcifications. Fresh dilute solutions show profiles identical to t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170118

    authors: Adzamli IK,Blau M

    更新日期:1991-01-01 00:00:00

  • Aortic wall shear stress in Marfan syndrome.

    abstract::The aim of this study was to quantify changes in thoracic aortic wall shear stress (WSS) in asymptomatic patients with Marfan syndrome (MFS) compared with healthy controls. WSS in the thoracic aorta was quantified based on time-resolved 3D phase contrast MRI with three-directional velocity encoding (4D flow MRI, tempo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24562

    authors: Geiger J,Arnold R,Herzer L,Hirtler D,Stankovic Z,Russe M,Langer M,Markl M

    更新日期:2013-10-01 00:00:00

  • Efficient biphasic spin-echo magnetic resonance imaging.

    abstract::The concept of temporal echo multiplexing is defined and used to develop rapid biphasic spin-echo sequences for imaging the heart. Three imaging sequences, based on four-echo and two-echo multiplexing and rapid single echo (i.e., conventional spin-echo imaging), are compared. Preliminary results indicate that two-echo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910110109

    authors: Parker DL,Caputo GR,Frederick PR

    更新日期:1989-07-01 00:00:00

  • High-resolution 31 P echo-planar spectroscopic imaging in vivo at 7T.

    abstract:PURPOSE:Conventional 31 P chemical shift imaging is time-consuming and yields only limited spatial resolution. The purpose of this study was to demonstrate feasibility of 31 P echo-planar spectroscopic imaging (EPSI) in vivo at 7T. METHODS:A 3D 31 P EPSI sequence with trapezoidal-shaped gradient pulses was implemented...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26785

    authors: Korzowski A,Bachert P

    更新日期:2018-03-01 00:00:00

  • Multiecho segmented EPI with z-shimmed background gradient compensation (MESBAC) pulse sequence for fMRI.

    abstract::A MultiEcho Segmented EPI with z-shimmed BAckground gradient Compensation (MESBAC) pulse sequence is proposed and validated for functional MRI (fMRI) study in regions suffering from severe susceptibility artifacts. This sequence provides an effective tradeoff between spatial and temporal resolution and reduces image d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10219

    authors: Li Z,Wu G,Zhao X,Luo F,Li SJ

    更新日期:2002-08-01 00:00:00

  • Dynamic slice-dependent shim and center frequency update in 3 T breast diffusion weighted imaging.

    abstract:PURPOSE:To demonstrate dynamic slice-dependent shim update as a simple method to reduce susceptibility-induced B0 inhomogeneity and associated pixel shift artifacts in diffusion-weighted echo planar imaging (DW-EPI) in 3 T breast imaging. METHODS:Dynamic slice-dependent update of linear shim and center frequency was i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24824

    authors: Lee SK,Tan ET,Govenkar A,Hancu I

    更新日期:2014-05-01 00:00:00

  • Sensitive enhancement of vessel wall imaging with an endoesophageal Wireless Amplified NMR Detector (WAND).

    abstract:PURPOSE:To improve the imaging quality of vessel walls with an endoesophageal Wireless Amplified NMR Detector (WAND). METHODS:A cylindrically shaped double-frequency resonator has been constructed with a single metal wire that is self-connected by a pair of nonlinear capacitors. The double-frequency resonator can conv...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26562

    authors: Zeng X,Barbic M,Chen L,Qian C

    更新日期:2017-11-01 00:00:00