Fe(III) distribution varies substantially within and between atherosclerotic plaques.

Abstract:

PURPOSE:Vulnerable atherosclerotic plaques are structurally weak and prone to rupture, presumably due to local oxidative stress. Redox active iron is linked to oxidative stress and the aim of this study was to investigate the distribution of Fe(III) in carotid plaques and its relation to vulnerability for rupture. METHODS:Atherosclerotic plaques from 10 patients (three asymptomatic and seven symptomatic) were investigated. Plaque vulnerability was classified using ultrasound and immunohistochemistry and correlated to Fe(III) measured by electron paramagnetic resonance spectroscopy. RESULTS:Large intra-plaque Fe(III) variations were found. Plaques from symptomatic patients had a higher Fe(III) concentration as compared with asymptomatic plaques (0.36 ± 0.21 vs. 0.06 ± 0.04 nmol Fe(III)/mg tissue, P < 0.05, in sections adjoining narrowest part of the plaques). All but one plaque from symptomatic patients showed signs of cap rupture. No plaque from asymptomatic patients showed signs of cap rupture. There was a significant increase in cap macrophages in plaques from symptomatic patients compared with asymptomatic patients (31 ± 11% vs. 2.3 ± 2.3%, P < 0.01). CONCLUSION:Fe(III) distribution varies substantially within atherosclerotic plaques. Plaques from symptomatic patients had significantly higher concentrations of Fe(III), signs of cap rupture and increased cap macrophage activity.

journal_name

Magn Reson Med

authors

Gustafsson H,Hallbeck M,Norell M,Lindgren M,Engström M,Rosén A,Zachrisson H

doi

10.1002/mrm.24687

subject

Has Abstract

pub_date

2014-02-01 00:00:00

pages

885-92

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

71

pub_type

杂志文章
  • Quantifying the effect of dobutamine stress on myocardial Pi and pH in healthy volunteers: A 31 P MRS study at 7T.

    abstract:PURPOSE:Phosphorus spectroscopy (31 P-MRS) is a proven method to probe cardiac energetics. Studies typically report the phosphocreatine (PCr) to adenosine triphosphate (ATP) ratio. We focus on another 31 P signal: inorganic phosphate (Pi), whose chemical shift allows computation of myocardial pH, with Pi/PCr providing ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28494

    authors: Apps A,Valkovič L,Peterzan M,Lau JYC,Hundertmark M,Clarke W,Tunnicliffe EM,Ellis J,Tyler DJ,Neubauer S,Rider OJ,Rodgers CT,Schmid AI

    更新日期:2021-03-01 00:00:00

  • Image reconstruction using a gradient impulse response model for trajectory prediction.

    abstract:PURPOSE:Gradient imperfections remain a challenge in MRI, especially for sequences relying on long imaging readouts. This work aims to explore image reconstruction based on k-space trajectories predicted by an impulse response model of the gradient system. THEORY AND METHODS:Gradient characterization was performed twi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25841

    authors: Vannesjo SJ,Graedel NN,Kasper L,Gross S,Busch J,Haeberlin M,Barmet C,Pruessmann KP

    更新日期:2016-07-01 00:00:00

  • In vitro 1H NMR "mapping" of human intervertebral discs.

    abstract::Human intervertebral discs were investigated by 1H NMR in vitro. The measured parameters of samples differently located in discs give the "maps" of discs. The spin-lattice relaxation-time maps show similar structure to dry matter and bound water maps, which might mean the future possibility to detect certain disc proc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030122

    authors: Furó I,Bobest M,Pócsik I,Tompa K

    更新日期:1986-02-01 00:00:00

  • Impact of transcytolemmal water exchange on estimates of tissue microstructural properties derived from diffusion MRI.

    abstract:PURPOSE:To investigate the influence of transcytolemmal water exchange on estimates of tissue microstructural parameters derived from diffusion MRI using conventional PGSE and IMPULSED methods. METHODS:Computer simulations were performed to incorporate a broad range of intracellular water life times τin (50-∞ ms), cel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26309

    authors: Li H,Jiang X,Xie J,Gore JC,Xu J

    更新日期:2017-06-01 00:00:00

  • Cardiac perfusion imaging using hyperpolarized (13)C urea using flow sensitizing gradients.

    abstract:PURPOSE:To demonstrate the feasibility of imaging the first passage of a bolus of hyperpolarized (13)C urea through the rodent heart using flow-sensitizing gradients to reduce signal from the blood pool. METHODS:A flow-sensitizing bipolar gradient was optimized to reduce the bright signal within the cardiac chambers, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25713

    authors: Lau AZ,Miller JJ,Robson MD,Tyler DJ

    更新日期:2016-04-01 00:00:00

  • MRI-guided radiofrequency thermal ablation of implanted VX2 liver tumors in a rabbit model: demonstration of feasibility at 0.2 T.

    abstract::Successful radiofrequency (RF) thermal ablation was performed on VX2 tumors implanted in 23 rabbit livers under magnetic resonance (MR) guidance using a C-arm-shaped low-field 0.2 T system. RF application and immediate postprocedure MRI of all animals was performed [T2-weighted, turbo short tau inversion recovery (STI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199907)42:1<141::aid-mrm19

    authors: Merkle EM,Boll DT,Boaz T,Duerk JL,Chung YC,Jacobs GH,Varnes ME,Lewin JS

    更新日期:1999-07-01 00:00:00

  • Histogram analysis of the microvasculature of intracerebral human and murine glioma xenografts.

    abstract::The purpose of this study is to examine the usefulness of histogram analysis combined with vessel size index (VSI) magnetic resonance imaging for the specific characterization of brain tumor microvasculature in a panel of six volume-matched glioma xenografts. Using a simple descriptive histogram analysis, significant ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22675

    authors: Just N

    更新日期:2011-03-01 00:00:00

  • Phase-updated regularized SENSE for navigator-free multishot diffusion imaging.

    abstract:PURPOSE:Either SENSE+CG or POCS-ICE methods can be used to correct for motion-induced phase errors in navigator-free multishot diffusion imaging. SENSE+CG has the advantage of a fast convergence, however, occasionally the convergence can be unstable, thus degrading the image quality. POCS-ICE has a stable convergence a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26361

    authors: Hu Z,Ma X,Truong TK,Song AW,Guo H

    更新日期:2017-07-01 00:00:00

  • Mechanisms of proton spin dephasing in a system of magnetic particles.

    abstract::For protons diffusing among a system of magnetic particles, the process by which initial phase coherence is lost depends substantially on particle size. In this article, evidence for three dephasing mechanisms is presented: an incremental process at small particle sizes (motional averaging regime), a discrete process ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22966

    authors: de Haan HW

    更新日期:2011-12-01 00:00:00

  • Wavelet-space correlation imaging for high-speed MRI without motion monitoring or data segmentation.

    abstract:PURPOSE:This study aims to (i) develop a new high-speed MRI approach by implementing correlation imaging in wavelet-space, and (ii) demonstrate the ability of wavelet-space correlation imaging to image human anatomy with involuntary or physiological motion. METHODS:Correlation imaging is a high-speed MRI framework in ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25546

    authors: Li Y,Wang H,Tkach J,Roach D,Woods J,Dumoulin C

    更新日期:2015-12-01 00:00:00

  • A new approach to autocalibrated dynamic parallel imaging based on the Karhunen-Loeve transform: KL-TSENSE and KL-TGRAPPA.

    abstract::TSENSE and TGRAPPA are autocalibrated parallel imaging techniques that can improve the temporal resolution and/or spatial resolution in dynamic magnetic resonance imaging applications. In its original form, TSENSE uses temporal low-pass filtering of the undersampled frames to create the sensitivity map. TGRAPPA uses a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22766

    authors: Ding Y,Chung YC,Jekic M,Simonetti OP

    更新日期:2011-06-01 00:00:00

  • SMS-HSL: Simultaneous multislice aliasing separation exploiting hankel subspace learning.

    abstract:PURPOSE:To develop a novel, simultaneous multislice reconstruction method that exploits Hankel subspace learning (SMS-HSL) for aliasing separation in the slice direction. METHODS:An SMS signal model with the Hankel-structured matrix was proposed. To efficiently suppress interslice leakage artifacts from a signal subsp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26527

    authors: Park S,Park J

    更新日期:2017-10-01 00:00:00

  • A highly sensitive lactate editing technique for surface coil spectroscopic imaging in vivo.

    abstract::A lactate editing sequence based on the use of spin-locking pulses with surface coils is described. The sequence retains more than 90% of the available lactate magnetization and suppresses at least 95% of the lipid signal in a single scan and ca. 99.5% after a simple two step cycle. The technique allows simultaneous o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290320

    authors: Bourgeois D,Kozlowski P

    更新日期:1993-03-01 00:00:00

  • Motion-adaptive spatio-temporal regularization for accelerated dynamic MRI.

    abstract::Accelerated magnetic resonance imaging techniques reduce signal acquisition time by undersampling k-space. A fundamental problem in accelerated magnetic resonance imaging is the recovery of quality images from undersampled k-space data. Current state-of-the-art recovery algorithms exploit the spatial and temporal stru...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24524

    authors: Asif MS,Hamilton L,Brummer M,Romberg J

    更新日期:2013-09-01 00:00:00

  • Multifrequency selective rf pulses for multislice MR imaging.

    abstract::A method is described for multislice imaging by means of rf pulses which contain a multifrequency excitation spectrum. These pulses label each slice by an individual signal phase and allow the separation of the signals from all the slices by subsequent add/subtract procedures. The image sensitivity corresponds to the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060315

    authors: Müller S

    更新日期:1988-03-01 00:00:00

  • High-resolution MRI with cardiac and respiratory gating allows for accurate in vivo atherosclerotic plaque visualization in the murine aortic arch.

    abstract::Genetically engineered mouse models provide enormous potential for investigation of the underlying mechanisms of atherosclerotic disease, but noninvasive imaging methods for analysis of atherosclerosis in mice are currently limited. This study aimed to demonstrate the feasibility of MRI to noninvasively visualize athe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10500

    authors: Wiesmann F,Szimtenings M,Frydrychowicz A,Illinger R,Hunecke A,Rommel E,Neubauer S,Haase A

    更新日期:2003-07-01 00:00:00

  • In vivo whole-blood T2 versus HbO2 calibration by modulating blood oxygenation level in the femoral vein through intermittent cuff occlusion.

    abstract:PURPOSE:To investigate the feasibility of estimating calibration constants (K and T2o ) in vivo for converting whole-blood T2 to blood hemoglobin oxygen saturation (HbO2 ) according to the Luz-Meiboom model, 1/T2=1/T2o+K(1-HbO2)2, where K and T2o are relaxivity and transverse relaxation time of fully saturated blood, r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26885

    authors: Langham MC,Rodríguez-Soto AE,Schwartz N,Wehrli FW

    更新日期:2018-04-01 00:00:00

  • Minimization of dead-periods in MRI pulse sequences for imaging oblique planes.

    abstract::With the advent of breath-hold MR cardiac imaging techniques, the minimization of TR and TE for oblique planes has become a critical issue. The slew rates and maximum currents of gradient amplifiers limit the minimum possible TR and TE by adding dead-periods to the pulse sequences. We propose a method of designing gra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320613

    authors: Atalar E,McVeigh ER

    更新日期:1994-12-01 00:00:00

  • Model of the human vasculature for studying the influence of contrast injection speed on cerebral perfusion MRI.

    abstract::Simulations of dynamic susceptibility contrast (DSC) MRI are frequently performed by assuming a certain shape for the input function and the microvascular response function. However, to investigate the influence of parameters that will affect the shape of the input function, a more complex model of the human vasculatu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10567

    authors: van Osch MJ,Vonken EJ,Wu O,Viergever MA,van der Grond J,Bakker CJ

    更新日期:2003-09-01 00:00:00

  • Whole-heart chemical shift encoded water-fat MRI.

    abstract:PURPOSE:To develop and evaluate a free-breathing chemical-shift-encoded (CSE) spoiled gradient-recalled echo (SPGR) technique for whole-heart water-fat imaging at 3 Tesla (T). METHODS:We developed a three-dimensional (3D) multi-echo SPGR pulse sequence with electrocardiographic gating and navigator echoes and evaluate...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24982

    authors: Taviani V,Hernando D,Francois CJ,Shimakawa A,Vigen KK,Nagle SK,Schiebler ML,Grist TM,Reeder SB

    更新日期:2014-09-01 00:00:00

  • Noise correlations in data simultaneously acquired from multiple surface coil arrays.

    abstract::Multiple images acquired simultaneously from an array of surface coils can be combined to give a composite image with an improved signal-to-noise ratio (SNR) and a large field of view. The composite images' SNR can be optimized by taking advantage of noise correlations between coils and phase shifts induced by surface...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910160202

    authors: Hayes CE,Roemer PB

    更新日期:1990-11-01 00:00:00

  • Introduction of the snake antenna array: Geometry optimization of a sinusoidal dipole antenna for 10.5T body imaging with lower peak SAR.

    abstract:PURPOSE:To improve imaging performance for body MRI with a local transmit array at 10.5T, the geometry of a dipole antenna was optimized to achieve lower peak specific absorption rate (SAR) levels and a more uniform transmit profile. METHODS:Electromagnetic simulations on a phantom were used to evaluate the SAR and ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28297

    authors: Steensma B,van de Moortele PF,Ertürk A,Grant A,Adriany G,Luijten P,Klomp D,van den Berg N,Metzger G,Raaijmakers A

    更新日期:2020-11-01 00:00:00

  • Eight-channel phased array coil and detunable TEM volume coil for 7 T brain imaging.

    abstract::An eight-channel receive-only brain coil and table-top detunable volume transmit coil were developed and tested at 7 T for human imaging. Optimization of this device required attention to sources of interaction between the array elements, between the transmit and receive coils and minimization of common mode currents ...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20547

    authors: Wiggins GC,Potthast A,Triantafyllou C,Wiggins CJ,Wald LL

    更新日期:2005-07-01 00:00:00

  • Extended graphical model for analysis of dynamic contrast-enhanced MRI.

    abstract::Kinetic analysis with mathematical models has become increasingly important to quantify physiological parameters in computed tomography (CT), positron emission tomography (PET), and dynamic contrast-enhanced MRI (DCE-MRI). The modified Kety/Tofts model and the graphical (Patlak) model have been widely applied to DCE-M...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22819

    authors: Chen H,Li F,Zhao X,Yuan C,Rutt B,Kerwin WS

    更新日期:2011-09-01 00:00:00

  • Rapid T1 mapping of mouse myocardium with saturation recovery Look-Locker method.

    abstract::Dynamic contrast-enhanced MRI using gadolinium or manganese provides unique characterization of myocardium and its pathology. In this study, an electrocardiography (ECG) triggered saturation recovery Look-Locker method was developed and validated for fast cardiac T(1) mapping in small animal models. By sampling the in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22544

    authors: Li W,Griswold M,Yu X

    更新日期:2010-11-01 00:00:00

  • Combined dynamic contrast-enhanced liver MRI and MRA using interleaved variable density sampling.

    abstract:PURPOSE:To develop and evaluate a method for volumetric contrast-enhanced MRI of the liver, with high spatial and temporal resolutions, for combined dynamic imaging and MR angiography (MRA) using a single injection of contrast agent. METHODS:An interleaved variable density (IVD) undersampling pattern was implemented i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25195

    authors: Salmani Rahimi M,Korosec FR,Wang K,Holmes JH,Motosugi U,Bannas P,Reeder SB

    更新日期:2015-03-01 00:00:00

  • The Rician distribution of noisy MRI data.

    abstract::The image intensity in magnetic resonance magnitude images in the presence of noise is shown to be governed by a Rician distribution. Low signal intensities (SNR < 2) are therefore biased due to the noise. It is shown how the underlying noise can be estimated from the images and a simple correction scheme is provided ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340618

    authors: Gudbjartsson H,Patz S

    更新日期:1995-12-01 00:00:00

  • RF heating measurement using MR thermometry and field monitoring: Methodological considerations and first in vivo results.

    abstract:PURPOSE:A MR thermometry (MRT) method with field monitoring is proposed to improve the measurement of small temperature variations induced in brain MRI exams. METHODS:MR thermometry experiments were performed at 7 Tesla with concurrent field monitoring and RF heating. Images were reconstructed with nominal k-space tra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28501

    authors: Le Ster C,Mauconduit F,Mirkes C,Bottlaender M,Boumezbeur F,Djemai B,Vignaud A,Boulant N

    更新日期:2021-03-01 00:00:00

  • High resolution hyperpolarized 13 C MRSI using SPICE at 9.4T.

    abstract:PURPOSE:To test the feasibility of using the SPICE (SPectroscopic Imaging by exploiting spatiospectral CorrElation) technique, which uses the partial separability of spectroscopic data, for high resolution hyperpolarized (HP) 13 C spectroscopic imaging. METHODS:Numerical simulations were performed to investigate the i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27061

    authors: Lee H,Song JE,Shin J,Joe E,Joo CG,Choi YS,Song HT,Kim DH

    更新日期:2018-08-01 00:00:00

  • NMR determination of myocardial pH in vivo: separation of tissue inorganic phosphate from blood 2,3-DPG.

    abstract::Phosphorus NMR can measure myocardial tissue pH from the chemical shift of inorganic phosphate (Pi) in isolated buffer-perfused hearts, but in vivo the Pi peak originating from the myocardium is obscured by the resonance of 2,3-diphosphoglycerate (DPG) in the blood, making pH difficult to determine. Taking advantage o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170209

    authors: Zahler R,Majumdar S,Frederick B,Laughlin M,Barrett E,Gore JC

    更新日期:1991-02-01 00:00:00