Extended graphical model for analysis of dynamic contrast-enhanced MRI.

Abstract:

:Kinetic analysis with mathematical models has become increasingly important to quantify physiological parameters in computed tomography (CT), positron emission tomography (PET), and dynamic contrast-enhanced MRI (DCE-MRI). The modified Kety/Tofts model and the graphical (Patlak) model have been widely applied to DCE-MRI results in disease processes such as cancer, inflammation, and ischemia. In this article, an intermediate model between the modified Kety/Tofts and Patlak models is derived from a mathematical expansion of the modified Kety/Tofts model. Simulations and an in vivo experiment involving DCE-MRI of carotid atherosclerosis were used to compare the new extended graphical model with the modified Kety/Tofts model and the Patlak model. In our simulated circumstances and the carotid artery application, we found that the extended graphical model exhibited lower noise sensitivity and provided more accurate estimates of the volume transfer constant (K(trans)) and fractional plasma volume (v(p)) than the modified Kety/Tofts model for DCE-MRI acquisitions of total duration less than 100-300 s, depending on kinetic parameters. In comparison with the Patlak model, we found that the extended graphical model exhibited 74.4-99.8% less bias in estimates of K(trans). Thus, the extended graphical model may allow kinetic modeling of DCE-MRI results with shortened data acquisition periods, without sacrificing accuracy in estimates of K(trans) and v(p).

journal_name

Magn Reson Med

authors

Chen H,Li F,Zhao X,Yuan C,Rutt B,Kerwin WS

doi

10.1002/mrm.22819

subject

Has Abstract

pub_date

2011-09-01 00:00:00

pages

868-78

issue

3

eissn

0740-3194

issn

1522-2594

journal_volume

66

pub_type

杂志文章
  • Aortic wall shear stress in Marfan syndrome.

    abstract::The aim of this study was to quantify changes in thoracic aortic wall shear stress (WSS) in asymptomatic patients with Marfan syndrome (MFS) compared with healthy controls. WSS in the thoracic aorta was quantified based on time-resolved 3D phase contrast MRI with three-directional velocity encoding (4D flow MRI, tempo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24562

    authors: Geiger J,Arnold R,Herzer L,Hirtler D,Stankovic Z,Russe M,Langer M,Markl M

    更新日期:2013-10-01 00:00:00

  • Spatially resolved assessment of serotonin-induced bronchoconstrictive responses in the rat lung using 3He ventilation MRI under spontaneous breathing conditions.

    abstract::The effect on lung ventilation of bronchoconstriction induced by serotonin (intravenous injection of 50 microg/kg of serotonin) was imaged using a hyperpolarized (3)He MR ventilation protocol in spontaneously breathing rats. Lung function maps assessing airflow obstruction, a key feature in clinical pneumology, were d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22391

    authors: Mosbah K,Stupar V,Berthezène Y,Beckmann N,Crémillieux Y

    更新日期:2010-06-01 00:00:00

  • In vitro 1H NMR "mapping" of human intervertebral discs.

    abstract::Human intervertebral discs were investigated by 1H NMR in vitro. The measured parameters of samples differently located in discs give the "maps" of discs. The spin-lattice relaxation-time maps show similar structure to dry matter and bound water maps, which might mean the future possibility to detect certain disc proc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030122

    authors: Furó I,Bobest M,Pócsik I,Tompa K

    更新日期:1986-02-01 00:00:00

  • CEST, ASL, and magnetization transfer contrast: How similar pulse sequences detect different phenomena.

    abstract::Chemical exchange saturation transfer (CEST), arterial spin labeling (ASL), and magnetization transfer contrast (MTC) methods generate different contrasts for MRI. However, they share many similarities in terms of pulse sequences and mechanistic principles. They all use RF pulse preparation schemes to label the longit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.27341

    authors: Knutsson L,Xu J,Ahlgren A,van Zijl PCM

    更新日期:2018-10-01 00:00:00

  • 31P NMR studies of resting zone cartilage from growth plate.

    abstract::31P NMR of superfused resting cartilage demonstrated the presence of phosphocreatine in chondrocytes. Changes in pH and in the NTP level were followed during carbon source starvation. From 31P spectra of perchloric acid extracts, phosphoethanolamine, phosphocholine, and the corresponding glycerol diesters were identif...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910250215

    authors: Kvam BJ,Pollesello P,Vittur F,Paoletti S

    更新日期:1992-06-01 00:00:00

  • Mean magnetic susceptibility regularized susceptibility tensor imaging (MMSR-STI) for estimating orientations of white matter fibers in human brain.

    abstract:PURPOSE:An increasing number of studies show that magnetic susceptibility in white matter fibers is anisotropic and may be described by a tensor. However, the limited head rotation possible for in vivo human studies leads to an ill-conditioned inverse problem in susceptibility tensor imaging (STI). Here we suggest the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25322

    authors: Li X,van Zijl PC

    更新日期:2014-09-01 00:00:00

  • Clinically compatible MRI strategies for discriminating bound and pore water in cortical bone.

    abstract::Advances in modern magnetic resonance imaging (MRI) pulse sequences have enabled clinically practical cortical bone imaging. Human cortical bone is known to contain a distribution of T(1) and T(2) components attributed to bound and pore water, although clinical imaging approaches have yet to discriminate bound from po...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24186

    authors: Horch RA,Gochberg DF,Nyman JS,Does MD

    更新日期:2012-12-01 00:00:00

  • Free breathing three-dimensional late gadolinium enhancement cardiovascular magnetic resonance using outer volume suppressed projection navigators.

    abstract:PURPOSE:To develop a three-dimensional, free-breathing, late gadolinium enhancement (3D FB-LGE) cardiovascular magnetic resonance (CMR) technique, and to compare it with clinically used two-dimensional breath-hold LGE (2D BH-LGE). METHODS:The proposed 3D FB-LGE method consisted of inversion preparation, inversion dela...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26234

    authors: Menon RG,Miller GW,Jeudy J,Rajagopalan S,Shin T

    更新日期:2017-04-01 00:00:00

  • Absolute oxygen tension (pO(2)) in murine fatty and muscle tissue as determined by EPR.

    abstract::The absolute partial pressure of oxygen (pO(2)) in the mammary gland pad and femoral muscle of female mice was measured using EPR oximetry at 700 MHz. A small quantity of lithium phthalocyanine (LiPc) crystals was implanted in both mammary and femoral muscle tissue of female C3H mice. Subsequent EPR measurements were ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20714

    authors: Matsumoto A,Matsumoto S,Sowers AL,Koscielniak JW,Trigg NJ,Kuppusamy P,Mitchell JB,Subramanian S,Krishna MC,Matsumoto K

    更新日期:2005-12-01 00:00:00

  • Data-driven optimized flip angle selection for T1 estimation from spoiled gradient echo acquisitions.

    abstract:PURPOSE:Define criteria for selection of optimal flip angle sets for T1 estimation and evaluate effects on T1 mapping. THEORY AND METHODS:Flip angle sets for spoiled gradient echo-based T1 mapping were selected by minimizing T1 estimate variance weighted by the joint density of M0 and T1 in an initial acquisition. The...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25920

    authors: Lewis CM,Hurley SA,Meyerand ME,Koay CG

    更新日期:2016-09-01 00:00:00

  • Iterative k-t principal component analysis with nonrigid motion correction for dynamic three-dimensional cardiac perfusion imaging.

    abstract:PURPOSE:In this study, an iterative k-t principal component analysis (PCA) algorithm with nonrigid frame-to-frame motion correction is proposed for dynamic contrast-enhanced three-dimensional perfusion imaging. METHODS:An iterative k-t PCA algorithm was implemented with regularization using training data corrected for...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24894

    authors: Schmidt JF,Wissmann L,Manka R,Kozerke S

    更新日期:2014-07-01 00:00:00

  • 3T MR of the prostate: reducing susceptibility gradients by inflating the endorectal coil with a barium sulfate suspension.

    abstract::Most prostate MRI/MRS examinations are performed with an endorectal coil inflated with air, leading to an air-tissue interface that induces magnetic susceptibility gradients within the gland. Inflation of the coil with a barium sulfate suspension is described and compared to inflation with air or liquid perfluorocarbo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21166

    authors: Rosen Y,Bloch BN,Lenkinski RE,Greenman RL,Marquis RP,Rofsky NM

    更新日期:2007-05-01 00:00:00

  • Toward fully automatic estimation of in vivo 31P spectra.

    abstract::Fitting a model to an experimental spectrum is a difficult nonlinear estimation problem. The solution presented here is to start an iterative search procedure sufficiently close to the optimal model parameter set. This is achieved by providing tissue-dependent a priori peak information and by a novel correlation metho...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910210206

    authors: Burger C,McKinnon G,Buchli R,Boesiger P

    更新日期:1991-10-01 00:00:00

  • MR microimaging of articular cartilage and contrast enhancement by manganese ions.

    abstract::Saline solutions of manganese ions (Mn2+) were used as articular contrast agents in magnetic resonance microscopy (9.4 T) of cartilage of chicken femoral condyles and pig temporomandibular joints. The diffusion of Mn2+ from the articular surface into the cartilage matrix led to a strong contrast enhancement in the car...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910240114

    authors: Kusaka Y,Gründer W,Rumpel H,Dannhauer KH,Gersonde K

    更新日期:1992-03-01 00:00:00

  • Correction for partial volume errors in MR heart perfusion imaging.

    abstract::Myocardial MR first-pass perfusion time courses are contaminated by signals from the ventricles (spillover) as a consequence of partial volume effects and motion. An early increase in the signal intensity from the myocardium is an indicator of contamination. This contamination leads to under- or overestimation of perf...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20015

    authors: Köstler H,Ritter C,Reiss-Zimmermann M,Beer M,Hahn D,Sandstede J

    更新日期:2004-04-01 00:00:00

  • An analysis of magnetic cross-relaxation between water and methylene protons in a model system.

    abstract::Experiments have been performed to demonstrate and quantify cross-relaxation between water and methylene resonances in a simple model system. Inversion recovery experiments on aqueous solutions of polyethylene glycol produce a transient nuclear Overhauser effect that alters the recovery of the methylene resonance. The...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910090305

    authors: Gore JC,Brown MS,Armitage IM

    更新日期:1989-03-01 00:00:00

  • A double echo ultra short echo time (UTE) acquisition for respiratory motion-suppressed high resolution imaging of the lung.

    abstract:PURPOSE:Magnetic resonance imaging is a promising alternative to computed tomography for lung imaging. However, organ motion and poor signal-to-noise ratio, arising from short T2*, impair image quality. To alleviate these issues, a new retrospective gating method was implemented and tested with an ultra-short echo time...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26891

    authors: Delacoste J,Chaptinel J,Beigelman-Aubry C,Piccini D,Sauty A,Stuber M

    更新日期:2018-04-01 00:00:00

  • High-order coils as transmitters for NMR imaging.

    abstract::High-order radiofrequency transmitter coils are described that permit, in the context of NMR imaging, a knowledgeable trade-off between coil complexity and the degree of inhomogeneity over a specified volume of space. A mathematical formulation of high-order coils is developed for an axially symmetric polarizing dc fi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030108

    authors: Sotgiu A,Hyde JS

    更新日期:1986-02-01 00:00:00

  • A novel phase-unwrapping method based on pixel clustering and local surface fitting with application to Dixon water-fat MRI.

    abstract:PURPOSE:To develop and evaluate a novel 2D phase-unwrapping method that works robustly in the presence of severe noise, rapid phase changes, and disconnected regions. THEORY AND METHODS:The MR phase map usually varies rapidly in regions adjacent to wraps. In contrast, the phasors can vary slowly, especially in regions...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26647

    authors: Cheng J,Mei Y,Liu B,Guan J,Liu X,Wu EX,Feng Q,Chen W,Feng Y

    更新日期:2018-01-01 00:00:00

  • Flow-gated phase-contrast MRI using radial acquisitions.

    abstract::Phase-contrast (PC) MRI is a noninvasive method for imaging blood and tissue velocity. PC experiments are typically segmented into many cardiac cycles in order to obtain sufficient spatial and temporal resolution, and thus require a gating signal to properly combine the data from multiple cardiac cycles. Although the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20187

    authors: Thompson RB,McVeigh ER

    更新日期:2004-09-01 00:00:00

  • Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP).

    abstract::A new parallel imaging technique was implemented which can result in reduced image acquisition times in MRI. MR data is acquired in parallel using an array of receiver coils and then reconstructed simultaneously with multiple processors. The method requires the initial estimation of the 2D sensitivity profile of each ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200008)44:2<301::aid-mrm18>3.0.c

    authors: Kyriakos WE,Panych LP,Kacher DF,Westin CF,Bao SM,Mulkern RV,Jolesz FA

    更新日期:2000-08-01 00:00:00

  • Sensitivity of MR diffusion measurements to variations in intracellular structure: effects of nuclear size.

    abstract::Magnetic resonance imaging measurements of the apparent rate of water diffusion in tumors are sensitive to variations in tissue cellularity, which have been shown useful for characterizing tumors and their responses to treatments. However, because of technical limitations on most MRI systems, conventional pulse gradie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21793

    authors: Xu J,Does MD,Gore JC

    更新日期:2009-04-01 00:00:00

  • On the steady-state properties of actual flip angle imaging (AFI).

    abstract::AFI (actual flip angle imaging) represents an interesting approach to map the B(1) transmit fields by measuring the spatial variations of the effective flip angle. However, the accuracy of the technique relies on the adequate spoiling of transverse magnetization. In the present work configuration theory was employed t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21592

    authors: Nehrke K

    更新日期:2009-01-01 00:00:00

  • The effect of reducing repetition time TR on the measurement of liver R2 for the purpose of measuring liver iron concentration.

    abstract::The effects of reducing the pulse repetition time from 2500 ms to 1000 ms when using spin-density-projection-assisted R2-magnetic resonance imaging for the purpose of measuring liver iron concentration were evaluated. Repeated liver R2 measurements were made using both protocols on 60 subjects with liver iron concentr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22712

    authors: Pavitt HL,Aydinok Y,El-Beshlawy A,Bayraktaroglu S,Ibrahim AS,Hamdy MM,Pang W,Sharples C,St Pierre TG

    更新日期:2011-05-01 00:00:00

  • Porous medium 3D flow simulation of contrast media washout in cardiac MRI reflects myocardial injury.

    abstract:PURPOSE:Myocardial blood-flow simulation based on laws of fluid mechanics is a valuable tool for understanding tissue behavior. Our aim is to evaluate the ability of a porous-media flow model approach to reflect disturbed washout of contrast media (CM) from the myocardium as observed by cardiovascular MR. METHODS:A co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27756

    authors: Riazy L,Schaeffter T,Olbrich M,Schueler J,von Knobelsdorff-Brenkenhoff F,Niendorf T,Schulz-Menger J

    更新日期:2019-08-01 00:00:00

  • Accelerated 3D T2 mapping with dictionary-based matching for prostate imaging.

    abstract:PURPOSE:To develop a fast and accurate method for 3D T2 mapping of prostate cancer using undersampled acquisition and dictionary-based fitting. METHODS:3D high-resolution T2 -weighted images (0.9 × 0.9 × 3 mm3 ) were obtained with a multishot T2 -prepared balanced steady-state free precession (T2 -prep-bSSFP) acquisit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27540

    authors: Roccia E,Vidya Shankar R,Neji R,Cruz G,Munoz C,Botnar R,Goh V,Prieto C,Dregely I

    更新日期:2019-03-01 00:00:00

  • Parallel excitation for B-field insensitive fat-saturation preparation.

    abstract::Multichannel transmission has the potential to improve many aspects of MRI through a new paradigm in excitation. In this study, multichannel transmission is used to address the effects that variations in B(0) homogeneity have on fat-saturation preparation through the use of the frequency, phase, and amplitude degrees ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23238

    authors: Heilman JA,Derakhshan JD,Riffe MJ,Gudino N,Tkach J,Flask CA,Duerk JL,Griswold MA

    更新日期:2012-08-01 00:00:00

  • Aortic 4D flow: quantification of signal-to-noise ratio as a function of field strength and contrast enhancement for 1.5T, 3T, and 7T.

    abstract:PURPOSE:To investigate for the first time the feasibility of aortic four-dimensional (4D) flow at 7T, both contrast enhanced (CE) and non-CE. To quantify the signal-to-noise ratio (SNR) in aortic 4D flow as a function of field strength and CE with gadobenate dimeglumine (MultiHance). METHODS:Six healthy male volunteer...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25317

    authors: Hess AT,Bissell MM,Ntusi NA,Lewis AJ,Tunnicliffe EM,Greiser A,Stalder AF,Francis JM,Myerson SG,Neubauer S,Robson MD

    更新日期:2015-05-01 00:00:00

  • Eight-channel phased array coil and detunable TEM volume coil for 7 T brain imaging.

    abstract::An eight-channel receive-only brain coil and table-top detunable volume transmit coil were developed and tested at 7 T for human imaging. Optimization of this device required attention to sources of interaction between the array elements, between the transmit and receive coils and minimization of common mode currents ...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20547

    authors: Wiggins GC,Potthast A,Triantafyllou C,Wiggins CJ,Wald LL

    更新日期:2005-07-01 00:00:00

  • Lung imaging under free-breathing conditions.

    abstract::Respiratory motion and pulsatile blood flow can generate artifacts in morphological and functional lung imaging. Total acquisition time, and thus the achievable signal to noise ratio, is limited when performing breath-hold and/or electrocardiogram-triggered imaging. To overcome these limitations, imaging during free r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21846

    authors: Oechsner M,Pracht ED,Staeb D,Arnold JF,Köstler H,Hahn D,Beer M,Jakob PM

    更新日期:2009-03-01 00:00:00