Transmit SENSE.

Abstract:

:The idea of using parallel imaging to shorten the acquisition time by the simultaneous use of multiple receive coils can be adapted for the parallel transmission of a spatially-selective multidimensional RF pulse. As in data acquisition, a multidimensional RF pulse follows a certain k-space trajectory. Shortening this trajectory shortens the pulse duration. The use of multiple transmit coils, each with its own time-dependent waveform and spatial sensitivity, can compensate for the missing parts of the excitation k-space. This results in a maintained spatial definition of the pulse profile, while its duration is reduced. This work introduces the concept of parallel transmission with arbitrarily shaped transmit coils (termed "Transmit SENSE"). Results of numerical studies demonstrate the theoretical feasibility of the approach. The experimental proof of principle is provided on a commercial MR scanner. The lack of multiple independent transmit channels was addressed by combining the excitation patterns from two separate subexperiments with different transmit setups. Shortening multidimensional RF pulses could be an interesting means of making 3D RF pulses feasible even for fast T(2)(*) relaxing species or strong main field inhomogeneities. Other applications might benefit from the ability of Transmit SENSE to improve the spatial resolution of the pulse profile while maintaining the transmit duration.

journal_name

Magn Reson Med

authors

Katscher U,Börnert P,Leussler C,van den Brink JS

doi

10.1002/mrm.10353

subject

Has Abstract

pub_date

2003-01-01 00:00:00

pages

144-50

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

49

pub_type

杂志文章
  • Separation and quantification of lactate and lipid at 1.3 ppm by diffusion-weighted magnetic resonance spectroscopy.

    abstract:PURPOSE:To separate the spectrally overlapped lactate and lipid signals at 1.3 ppm using diffusion-weighted magnetic resonance spectroscopy (DW-MRS) based on their large diffusivity difference. METHODS:DW-MRS was applied to the gel phantoms containing lactate and lipid droplets, and to the rat brain tumors. Lactate an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26144

    authors: Wang AM,Leung GK,Kiang KM,Chan D,Cao P,Wu EX

    更新日期:2017-02-01 00:00:00

  • Proton-observed carbon-edited NMR spectroscopy in strongly coupled second-order spin systems.

    abstract::Proton-observed carbon-edited (POCE) NMR spectroscopy is commonly used to measure 13C labeling with higher sensitivity compared to direct 13C NMR spectroscopy, at the expense of spectral resolution. For weakly coupled first-order spin systems, the multiplet signal at a specific proton chemical shift in POCE spectra di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20764

    authors: Henry PG,Marjanska M,Walls JD,Valette J,Gruetter R,Ugurbil K

    更新日期:2006-02-01 00:00:00

  • Metabolite 1H relaxation in normal and hyponatremic brain.

    abstract::Proton spin relaxation rate constants in normal and hyponatremic rat brain were measured to determine the sensitivity of metabolite relaxation properties to cytotoxic edema and to quantify metabolite concentration in normal and edematous brain. Relaxation rate constants for protons of water and spectral regions with d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350510

    authors: Rooney WD,Ebisu T,Mancuso A,Graham S,Weiner MW,Maudsley AA

    更新日期:1996-05-01 00:00:00

  • A flexible nested sodium and proton coil array with wideband matching for knee cartilage MRI at 3T.

    abstract:PURPOSE:We describe a 2 × 6 channel sodium/proton array for knee MRI at 3T. Multielement coil arrays are desirable because of well-known signal-to-noise ratio advantages over volume and single-element coils. However, low tissue-coil coupling that is characteristic of coils operating at low frequency can make the potent...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26017

    authors: Brown R,Lakshmanan K,Madelin G,Alon L,Chang G,Sodickson DK,Regatte RR,Wiggins GC

    更新日期:2016-10-01 00:00:00

  • A framework for optimization-based design of motion encoding in magnetic resonance elastography.

    abstract:PURPOSE:In conventional three-dimensional magnetic resonance elastography, motion encoding gradients (MEGs) synchronized to a mechanical excitation are applied separately in each direction to encode tissue displacement generated by the corresponding waves. This requires long acquisition times that introduce errors due ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25280

    authors: Nir G,Sahebjavaher RS,Sinkus R,Salcudean SE

    更新日期:2015-04-01 00:00:00

  • Steady state of echo-shifted sequences with radiofrequency phase cycling.

    abstract::Due to a delayed echo-formation, echo-shifted gradient echo sequences (ES-GRE) allow for an enhanced T(2)*-weighting at short repetition times. While they are in use with and without RF spoiling, analytical solutions are only known for the latter. The signal formation in the former could only be assessed in approximat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21010

    authors: Ganter C

    更新日期:2006-10-01 00:00:00

  • Phase-updated regularized SENSE for navigator-free multishot diffusion imaging.

    abstract:PURPOSE:Either SENSE+CG or POCS-ICE methods can be used to correct for motion-induced phase errors in navigator-free multishot diffusion imaging. SENSE+CG has the advantage of a fast convergence, however, occasionally the convergence can be unstable, thus degrading the image quality. POCS-ICE has a stable convergence a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26361

    authors: Hu Z,Ma X,Truong TK,Song AW,Guo H

    更新日期:2017-07-01 00:00:00

  • Rapid radiofrequency field mapping in vivo using single-shot STEAM MRI.

    abstract::Higher field strengths entail less homogeneous RF fields. This may influence quantitative MRI and MRS. A method for rapidly mapping the RF field in the human head with minimal distortion was developed on the basis of a single-shot stimulated echo acquisition mode (STEAM) sequence. The flip angle of the second RF pulse...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21676

    authors: Helms G,Finsterbusch J,Weiskopf N,Dechent P

    更新日期:2008-09-01 00:00:00

  • A single acquisition localization technique.

    abstract::A method is demonstrated for detection of magnetization from a selected region within the sensitive volume of a surface coil in a single acquisition. Composite pulses are described which eliminate signals from regions where magnetization is rotated 270 and 450 degrees. There is a loss of 1.3% or less of signal from re...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030221

    authors: Karczmar GS,Matson GB,Weiner MW

    更新日期:1986-04-01 00:00:00

  • Generalized matched filtering for time-resolved MR angiography of pulsatile flow.

    abstract::Generating flow-specific images (arteriograms, venograms) with optimal signal-to-noise ratios for time-resolved MR angiography is a conditional maximum problem, and its solutions are generalized matched filters. We have investigated six matched filters, corresponding to all possible combinations of three flow suppress...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300511

    authors: Wang Y,Weber DM,Korosec FR,Mistretta CA,Grist TM,Swan JS,Turski PA

    更新日期:1993-11-01 00:00:00

  • Intracellular bimodal nanoparticles based on quantum dots for high-field MRI at 21.1 T.

    abstract::Multimodal, biocompatible contrast agents for high magnetic field applications represent a new class of nanomaterials with significant potential for tracking of fluorescence and MR in vitro and vivo. Optimized for high-field MR applications-including biomedical imaging at 21.1 T, the highest magnetic field available f...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22441

    authors: Rosenberg JT,Kogot JM,Lovingood DD,Strouse GF,Grant SC

    更新日期:2010-09-01 00:00:00

  • Optimized saturation pulse train for human first-pass myocardial perfusion imaging at 7T.

    abstract:PURPOSE:To investigate whether saturation using existing methods developed for 3T imaging is feasible for clinical perfusion imaging at 7T, and to propose a new design of saturation pulse train for first-pass myocardial perfusion imaging at 7T. METHODS:The new design of saturation pulse train consists of four hyperbol...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25262

    authors: Tao Y,Hess AT,Keith GA,Rodgers CT,Liu A,Francis JM,Neubauer S,Robson MD

    更新日期:2015-04-01 00:00:00

  • Application of phase rotation to STRESS localization scheme at 3 T.

    abstract:PURPOSE:Application of phase rotation to the STRESS (=STEAM+PRESS) localization scheme, to shorten echo time, minimize J-coupling dephasing and estimate B1+ inhomogeneity. STRESS (=STEAM + PRESS) simultaneously refocuses and acquires the double spin echo (SE123 ) and stimulated echo (STE- ) pathways, combining PRESS-li...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26911

    authors: Volovyk O,Tal A

    更新日期:2018-05-01 00:00:00

  • Sodium imaging of human brain at 7 T with 15-channel array coil.

    abstract::Signal-to-noise ratio (SNR) is a major challenge to sodium magnetic resonance imaging. Phased array coils have been shown significantly improving SNR in proton imaging over volume coils. This study investigates SNR advantage of a 15-channel array head coil (birdcage volume coil for transmit/receive and 15-channel arra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24192

    authors: Qian Y,Zhao T,Wiggins GC,Wald LL,Zheng H,Weimer J,Boada FE

    更新日期:2012-12-01 00:00:00

  • Functional imaging with FENSI: flow-enhanced signal intensity.

    abstract::Flow measurement methods for functional MRI (fMRI) are desirable as they are more closely tied to neuronal activity than the commonly used blood oxygenation techniques. In this work we introduce a flow-based functional imaging method. The method, called flow enhancement of signal intensity (FENSI), is an extension of ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21325

    authors: Sutton BP,Ouyang C,Ching BL,Ciobanu L

    更新日期:2007-08-01 00:00:00

  • Arterial spin labeling perfusion fMRI with very low task frequency.

    abstract::Functional magnetic resonance imaging (fMRI) has become the most widely used modality for visualizing regional brain activation in response to sensorimotor or cognitive tasks. While the majority of fMRI studies have used blood oxygenation level-dependent (BOLD) contrast as a marker for neural activation, baseline drif...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10437

    authors: Wang J,Aguirre GK,Kimberg DY,Roc AC,Li L,Detre JA

    更新日期:2003-05-01 00:00:00

  • Exploring the limits of RF shimming for high-field MRI of the human head.

    abstract::Several methods have been proposed for overcoming the effects of radiofrequency (RF) magnetic field inhomogeneity in high-field MRI. Some of these methods rely at least in part on the ability to independently control magnitude and phase of different drives in either one multielement RF coil or in different RF coils in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21013

    authors: Mao W,Smith MB,Collins CM

    更新日期:2006-10-01 00:00:00

  • Pharmacological MRI of the choroid and retina: blood flow and BOLD responses during nitroprusside infusion.

    abstract::Nitroprusside, a vasodilatory nitric oxide donor, is clinically used during vascular surgery and to lower blood pressure in acute hypertension. This article reports a novel application of blood flow (BF) and blood oxygenation level dependent (BOLD) MRI on an 11.7T scanner to image the rat chorioretinal BF and BOLD cha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24112

    authors: Shih YY,Li G,Muir ER,De La Garza BH,Kiel JW,Duong TQ

    更新日期:2012-10-01 00:00:00

  • Development and optimization of hardware for delta relaxation enhanced MRI.

    abstract:PURPOSE:Delta relaxation enhanced magnetic resonance (dreMR) imaging requires an auxiliary B0 electromagnet capable of shifting the main magnetic field within a clinical 1.5 Tesla (T) MR system. In this work, the main causes of interaction between an actively shielded, insertable resistive B0 electromagnet and a 1.5T s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25014

    authors: Harris CT,Handler WB,Araya Y,Martínez-Santiesteban F,Alford JK,Dalrymple B,Van Sas F,Chronik BA,Scholl TJ

    更新日期:2014-10-01 00:00:00

  • Simple analytical dual-band spectral-spatial RF pulses for B(1) + and susceptibility artifact reduction in gradient echo MRI.

    abstract::Susceptibility artifacts and transmission radio frequency (RF) field (B(1) +) inhomogeneity are major limitations in high-field gradient echo MRI. Previously proposed numerical 2D spectral-spatial RF pulses have been shown to be promising for reducing the through-plane signal loss susceptibility artifact by incorporat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22725

    authors: Yang C,Deng W,Stenger VA

    更新日期:2011-02-01 00:00:00

  • Black-blood native T1 mapping: Blood signal suppression for reduced partial voluming in the myocardium.

    abstract:PURPOSE:To study the feasibility of black-blood contrast in native T1 mapping for reduction of partial voluming at the blood-myocardium interface. METHODS:A saturation pulse prepared heart-rate-independent inversion recovery (SAPPHIRE) T1 mapping sequence was combined with motion-sensitized driven-equilibrium (MSDE) b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26378

    authors: Weingärtner S,Meßner NM,Zöllner FG,Akçakaya M,Schad LR

    更新日期:2017-08-01 00:00:00

  • Investigating the BOLD effect during infusion of Gd-DTPA using rapid T2* mapping.

    abstract::This work aimed to investigate the effects of administering Gd-DTPA on the BOLD effect, and to determine the feasibility of using this approach to measure fractional changes in blood volume and blood oxygenation on neuronal activation during a visual paradigm. A linear relationship between cortical R(2)(*) and the int...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10340

    authors: Pears JA,Francis ST,Butterworth SE,Bowtell RW,Gowland PA

    更新日期:2003-01-01 00:00:00

  • Improved data reconstruction method for GRAPPA.

    abstract::This paper presents an improved data reconstruction method for generalized autocalibrating partially parallel acquisitions (GRAPPA) using multicolumn multiline interpolation (MCMLI). Both nearest acquired line (ky) neighboring points and column (kx) neighboring points from all components of an array coil were used to ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20601

    authors: Wang Z,Wang J,Detre JA

    更新日期:2005-09-01 00:00:00

  • Intensity correction for multichannel hyperpolarized 13C imaging of the heart.

    abstract:PURPOSE:Develop and test an analytic correction method to correct the signal intensity variation caused by the inhomogeneous reception profile of an eight-channel phased array for hyperpolarized (13) C imaging. THEORY AND METHODS:Fiducial markers visible in anatomical images were attached to the individual coils to pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26042

    authors: Dominguez-Viqueira W,Geraghty BJ,Lau JY,Robb FJ,Chen AP,Cunningham CH

    更新日期:2016-02-01 00:00:00

  • Diffusional kurtosis imaging: the quantification of non-gaussian water diffusion by means of magnetic resonance imaging.

    abstract::A magnetic resonance imaging method is presented for quantifying the degree to which water diffusion in biologic tissues is non-Gaussian. Since tissue structure is responsible for the deviation of water diffusion from the Gaussian behavior typically observed in homogeneous solutions, this method provides a specific me...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20508

    authors: Jensen JH,Helpern JA,Ramani A,Lu H,Kaczynski K

    更新日期:2005-06-01 00:00:00

  • Temporal frequency analysis of dynamic MRI techniques.

    abstract::Dynamic imaging strategies often involve updating certain areas of k-space (i.e., the low spatial frequencies) more frequently than others. However, important dynamic signal changes may occur anywhere in k-space. In this study, a dynamic k-space sampling analysis method was developed to determine the energy error asso...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1074

    authors: Wu Y,Alexander AL

    更新日期:2001-04-01 00:00:00

  • Transverse relaxation time constants of the five major metabolites in human brain measured in vivo using LASER and PRESS at 3 T.

    abstract:PURPOSE:The goal of this study was to measure and compare the apparent transverse relaxation time constants (T2 ) of five intracellular metabolites using localization by adiabatic selective refocusing (LASER) and point-resolved spectroscopy (PRESS) sequences in the human brain at 3 T. METHODS:Five healthy subjects wer...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26826

    authors: Deelchand DK,Auerbach EJ,Kobayashi N,Marjańska M

    更新日期:2018-03-01 00:00:00

  • Removal of nuisance signals from limited and sparse 1H MRSI data using a union-of-subspaces model.

    abstract:PURPOSE:To remove nuisance signals (e.g., water and lipid signals) for (1) H MRSI data collected from the brain with limited and/or sparse (k, t)-space coverage. METHODS:A union-of-subspace model is proposed for removing nuisance signals. The model exploits the partial separability of both the nuisance signals and the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25635

    authors: Ma C,Lam F,Johnson CL,Liang ZP

    更新日期:2016-02-01 00:00:00

  • Apparent changes of appearance of inversion-recovery images.

    abstract::This note considers the anomolous contrast in inversion recovery images produced by NMR scanners if a map of [My] is reconstructed, rather than a map of My'. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910020110

    authors: Young IR,Bailes DR,Bydder GM

    更新日期:1985-02-01 00:00:00

  • High-order coils as transmitters for NMR imaging.

    abstract::High-order radiofrequency transmitter coils are described that permit, in the context of NMR imaging, a knowledgeable trade-off between coil complexity and the degree of inhomogeneity over a specified volume of space. A mathematical formulation of high-order coils is developed for an axially symmetric polarizing dc fi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030108

    authors: Sotgiu A,Hyde JS

    更新日期:1986-02-01 00:00:00