Removal of nuisance signals from limited and sparse 1H MRSI data using a union-of-subspaces model.

Abstract:

PURPOSE:To remove nuisance signals (e.g., water and lipid signals) for (1) H MRSI data collected from the brain with limited and/or sparse (k, t)-space coverage. METHODS:A union-of-subspace model is proposed for removing nuisance signals. The model exploits the partial separability of both the nuisance signals and the metabolite signal, and decomposes an MRSI dataset into several sets of generalized voxels that share the same spectral distributions. This model enables the estimation of the nuisance signals from an MRSI dataset that has limited and/or sparse (k, t)-space coverage. RESULTS:The proposed method has been evaluated using in vivo MRSI data. For conventional chemical shift imaging data with limited k-space coverage, the proposed method produced "lipid-free" spectra without lipid suppression during data acquisition at 130 ms echo time. For sparse (k, t)-space data acquired with conventional pulses for water and lipid suppression, the proposed method was also able to remove the remaining water and lipid signals with negligible residuals. CONCLUSION:Nuisance signals in (1) H MRSI data reside in low-dimensional subspaces. This property can be utilized for estimation and removal of nuisance signals from (1) H MRSI data even when they have limited and/or sparse coverage of (k, t)-space. The proposed method should prove useful especially for accelerated high-resolution (1) H MRSI of the brain.

journal_name

Magn Reson Med

authors

Ma C,Lam F,Johnson CL,Liang ZP

doi

10.1002/mrm.25635

subject

Has Abstract

pub_date

2016-02-01 00:00:00

pages

488-97

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

75

pub_type

杂志文章
  • T1 rho relaxation and its application to MR histology.

    abstract::The application of T1 rho an an alternative contrast parameter in high-field magnetic resonance histology (MRH) has been investigated. Spectroscopic measurements of T1 rho were performed on 5.75% agar and 1.0 mM MnCI2 phantoms at 9.4 T to validate the accuracy of the imaging measurements. Image studies were performed ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350520

    authors: Engelhardt RT,Johnson GA

    更新日期:1996-05-01 00:00:00

  • Investigating the BOLD effect during infusion of Gd-DTPA using rapid T2* mapping.

    abstract::This work aimed to investigate the effects of administering Gd-DTPA on the BOLD effect, and to determine the feasibility of using this approach to measure fractional changes in blood volume and blood oxygenation on neuronal activation during a visual paradigm. A linear relationship between cortical R(2)(*) and the int...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10340

    authors: Pears JA,Francis ST,Butterworth SE,Bowtell RW,Gowland PA

    更新日期:2003-01-01 00:00:00

  • 3D compressed sensing for highly accelerated hyperpolarized (13)C MRSI with in vivo applications to transgenic mouse models of cancer.

    abstract::High polarization of nuclear spins in liquid state through hyperpolarized technology utilizing dynamic nuclear polarization has enabled the direct monitoring of (13)C metabolites in vivo at a high signal-to-noise ratio. Acquisition time limitations due to T(1) decay of the hyperpolarized signal require accelerated ima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22233

    authors: Hu S,Lustig M,Balakrishnan A,Larson PE,Bok R,Kurhanewicz J,Nelson SJ,Goga A,Pauly JM,Vigneron DB

    更新日期:2010-02-01 00:00:00

  • Fast maximum intensity projection algorithm using shear warp factorization and reduced resampling.

    abstract::Maximal intensity projection (MIP) is routinely used to view MRA and other volumetric angiographic data. The straightforward implementation of MIP is ray casting that traces a volumetric data set in a computationally expensive manner. This article reports a fast MIP algorithm using shear warp factorization and reduced...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10114

    authors: Fang L,Wang Y,Qiu B,Qian Y

    更新日期:2002-04-01 00:00:00

  • Sources of functional apparent diffusion coefficient changes investigated by diffusion-weighted spin-echo fMRI.

    abstract::The mechanism behind previously observed changes in the apparent diffusion coefficient (ADC) during brain activation is not well understood. Therefore, we investigated the signal source and spatial specificity of functional magnetic resonance imaging (fMRI) ADC changes systematically in the visual cortex of cats using...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21074

    authors: Jin T,Zhao F,Kim SG

    更新日期:2006-12-01 00:00:00

  • Apparent diffusion coefficients of the five major metabolites measured in the human brain in vivo at 3T.

    abstract:PURPOSE:To measure the apparent diffusion coefficients (ADC) of five main metabolites in the human brain at 3T with PRESS and STEAM, avoiding measurement biases because of cross-terms. Cross-terms arise from interactions between slice-selection and spoiler gradients in the localized spectroscopy sequence and the diffus...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26969

    authors: Deelchand DK,Auerbach EJ,Marjańska M

    更新日期:2018-06-01 00:00:00

  • TOWERS: T-One with Enhanced Robustness and Speed.

    abstract:PURPOSE:A new T1 mapping method is proposed that is accurate, rapid, and robust to motion. Considering these features, the method is dubbed "T-One with Enhanced Robustness and Speed (TOWERS)." METHODS:TOWERS is composed of inversion recovery (IR) and saturation recovery (SR) acquisitions. In the IR acquisitions, a sli...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25864

    authors: Eldeniz C,Finsterbusch J,Lin W,An H

    更新日期:2016-07-01 00:00:00

  • Fast mapping of myocardial blood flow with MR first-pass perfusion imaging.

    abstract::Accurate and fast quantification of myocardial blood flow (MBF) with MR first-pass perfusion imaging techniques on a pixel-by-pixel basis remains difficult due to relatively long calculation times and noise-sensitive algorithms. In this study, Zierler's central volume principle was used to develop an algorithm for the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21559

    authors: Goldstein TA,Jerosch-Herold M,Misselwitz B,Zhang H,Gropler RJ,Zheng J

    更新日期:2008-06-01 00:00:00

  • Single-breath clinical imaging of hyperpolarized (129)Xe in the airspaces, barrier, and red blood cells using an interleaved 3D radial 1-point Dixon acquisition.

    abstract:PURPOSE:We sought to develop and test a clinically feasible 1-point Dixon, three-dimensional (3D) radial acquisition strategy to create isotropic 3D MR images of (129)Xe in the airspaces, barrier, and red blood cells (RBCs) in a single breath. The approach was evaluated in healthy volunteers and subjects with idiopathi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25675

    authors: Kaushik SS,Robertson SH,Freeman MS,He M,Kelly KT,Roos JE,Rackley CR,Foster WM,McAdams HP,Driehuys B

    更新日期:2016-04-01 00:00:00

  • Localized double-quantum filter and correlation spectroscopy experiments.

    abstract::Problems with in vivo proton spectroscopy include strong water and lipid signals, and the very complicated structures of the spectra. Multiple-quantum experiments can be designed to overcome these difficulties. Using a volume selective refocusing technique, one can demonstrate how multiple-quantum experiments can be p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060311

    authors: McKinnon GC,Bosiger P

    更新日期:1988-03-01 00:00:00

  • Perfusion-based event-related functional MRI.

    abstract::Perfusion-based event-related functional MRI was performed by measuring flow-sensitive alternating inversion recovery (FAIR) signal changes during repeated single-trial, short visual stimulation (250 msec). In the visual cortex activation area, the blood flow increases immediately after the stimulus, reaches the maxim...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199912)42:6<1011::aid-mrm3

    authors: Liu HL,Gao JH

    更新日期:1999-12-01 00:00:00

  • The effect of realistic geometries on the susceptibility-weighted MR signal in white matter.

    abstract:PURPOSE:To investigate the effect of realistic microstructural geometry on the susceptibility-weighted MR signal in white matter (WM), with application to demyelination. METHODS:Previous work has modeled susceptibility-weighted signals under the assumption that axons are cylindrical. In this study, we explored the imp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26689

    authors: Xu T,Foxley S,Kleinnijenhuis M,Chen WC,Miller KL

    更新日期:2018-01-01 00:00:00

  • Spin echo measurements of the extravasation and tumor cell uptake of hyperpolarized [1-(13) C]lactate and [1-(13) C]pyruvate.

    abstract:PURPOSE:To assess the blood-tissue distribution of hyperpolarized (13) C-labeled molecules in vivo. METHODS:Spin-echo experiments with simultaneous acquisition of the free induction decay (FID) signal following the excitation pulse and the spin-echo signal, were used to monitor hyperpolarized [1-(13) C]lactate, [1-(13...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24591

    authors: Kettunen MI,Kennedy BW,Hu DE,Brindle KM

    更新日期:2013-11-01 00:00:00

  • ΔR2 (*) gadolinium-diethylenetriaminepentacetic acid relaxivity in venous blood.

    abstract::The accuracy of perfusion measurements using dynamic, susceptibility-weighted, contrast-enhanced MRI depends on estimating contrast agent concentration in an artery, i.e., the arterial input function. One of the difficulties associated with obtaining an arterial input function are partial volume effects when both bloo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24331

    authors: Patil V,Johnson G

    更新日期:2013-04-01 00:00:00

  • Regularized higher-order in vivo shimming.

    abstract::A regularized algorithm is presented for localized in vivo shimming. The technique uses first- (X,Y,Z), second- (Z(2), ZX, ZY, X(2)-Y(2), XY), and third-order (Z(3)) shim coils, and is robust when applied to arbitrarily-shaped, as well as off-center, regions of interest (ROIs). A single-shot spiral pulse sequence is u...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10267

    authors: Kim DH,Adalsteinsson E,Glover GH,Spielman DM

    更新日期:2002-10-01 00:00:00

  • On the calculation of magnetization slice profiles for NMR imaging and in vivo spectroscopy.

    abstract::When developing new techniques for NMR imaging and in vivo spectroscopy it is a major advantage to be able to calculate the magnetization slice profiles, at any point during a pulse sequence in the presence of a field gradient. While this has frequently been done by treating the problem as a number of discrete resonan...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050511

    authors: Bulsing JM,Galloway GJ,Brereton IM,Doddrell DM

    更新日期:1987-11-01 00:00:00

  • Coronary MR angiography using image-based respiratory motion compensation with inline correction and fixed gating efficiency.

    abstract:PURPOSE:The purpose of this study was to evaluate a new inline motion compensation approach called image-based navigation with Constant Respiratory efficiency UsIng Single End-expiratory threshold (iNAV-CRUISE) for coronary MR angiography (CMRA). METHODS:The CRUISE gating technique was combined with iNAV motion correc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26678

    authors: Henningsson M,Smink J,van Ensbergen G,Botnar R

    更新日期:2018-01-01 00:00:00

  • Parallel transmit capability of various RF transmit elements and arrays at 7T MRI.

    abstract:PURPOSE:In this work, 22 configurations for remote radiofrequency (RF) coil arrays consisting of different transmit element designs for 7 Tesla (T) ultrahigh-field MRI are compared by numerical simulations. METHODS:Investigated transmit RF element types are rectangular loops, micro striplines, micro striplines with me...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26704

    authors: Rietsch SHG,Orzada S,Bitz AK,Gratz M,Ladd ME,Quick HH

    更新日期:2018-02-01 00:00:00

  • Quantitative assessment of improved homogeneity using higher-order shims for spectroscopic imaging of the brain.

    abstract::Magnetic field homogeneity is of major concern for in vivo spectroscopy, and with the increased use of volumetric chemical shift imaging (CSI) techniques, the ability to shim over a large volume of tissue is now one of the primary limiting constraints in performing these studies. In vivo shimming is routinely performe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400307

    authors: Spielman DM,Adalsteinsson E,Lim KO

    更新日期:1998-09-01 00:00:00

  • Temporal frequency analysis of dynamic MRI techniques.

    abstract::Dynamic imaging strategies often involve updating certain areas of k-space (i.e., the low spatial frequencies) more frequently than others. However, important dynamic signal changes may occur anywhere in k-space. In this study, a dynamic k-space sampling analysis method was developed to determine the energy error asso...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1074

    authors: Wu Y,Alexander AL

    更新日期:2001-04-01 00:00:00

  • Variable echo time imaging: signal characteristics of 1-M gadobutrol contrast agent at 1.5 and 3T.

    abstract::Gadobutrol (Gd-Bt; Gadovist(R), Schering AG) is a 1-M Gadolinium (Gd)-based contrast agent. Its higher Gd concentration allows for reduction of injection volumes in first pass contrast-enhanced MR angiography (CE-MRA) and should increase bolus sharpness and image quality. However, ambivalent results were reported. In ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21345

    authors: Stalder AF,Elverfeldt DV,Paul D,Hennig J,Markl M

    更新日期:2008-01-01 00:00:00

  • A magnetic shield for large-bore, high field magnets.

    abstract::An effective shield for the dc fringing fields produced by a large-bore, high field magnet intended for imaging and in vivo spectroscopy is presented. While limiting the extent of fringe fields, the shield has little effect on the homogeneity of the central field of the magnet. The effect of institutional safety polic...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910020506

    authors: Ewing JR,Timms W,Williams JE,Welch KM

    更新日期:1985-10-01 00:00:00

  • Feasibility and performance of breath-hold 3D true-FISP coronary MRA using self-calibrating parallel acquisition.

    abstract::Spatial resolution in 3D breath-hold coronary MR angiography (MRA) is limited by imaging time. The purpose of this work was to investigate the feasibility of improving the spatial resolution of coronary MRA using generalized autocalibrating partially parallel acquisition (GRAPPA) and fast imaging with steady state pre...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20153

    authors: Park J,McCarthy R,Li D

    更新日期:2004-07-01 00:00:00

  • Off-resonance-dependent slice profile effects in balanced steady-state free precession imaging.

    abstract::The purpose of this study was the simulation and measurement of balanced steady-state free precession (bSSFP) slice profiles for a detailed analysis of the influence of off-resonance effects on slice profile shape and bSSFP signal intensity. Due to the frequency response function of the bSSFP sequence, measurements th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21557

    authors: Staehle F,Leupold J,Hennig J,Markl M

    更新日期:2008-05-01 00:00:00

  • Volumetric analysis of white matter, gray matter, and CSF using fractional volume analysis.

    abstract::Quantitative cerebral tissue volumes may be useful for an objective assessment of pathological changes in brain. Accurate determination of tissue volumes is complicated, however, by the partial volume averaging (PVA) effect. We have, therefore, developed a new pulse sequence that minimizes the PVA through the use of i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390614

    authors: Bedell BJ,Narayana PA

    更新日期:1998-06-01 00:00:00

  • Absolute oxygen tension (pO(2)) in murine fatty and muscle tissue as determined by EPR.

    abstract::The absolute partial pressure of oxygen (pO(2)) in the mammary gland pad and femoral muscle of female mice was measured using EPR oximetry at 700 MHz. A small quantity of lithium phthalocyanine (LiPc) crystals was implanted in both mammary and femoral muscle tissue of female C3H mice. Subsequent EPR measurements were ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20714

    authors: Matsumoto A,Matsumoto S,Sowers AL,Koscielniak JW,Trigg NJ,Kuppusamy P,Mitchell JB,Subramanian S,Krishna MC,Matsumoto K

    更新日期:2005-12-01 00:00:00

  • The dependence of radiofrequency induced pacemaker lead tip heating on the electrical conductivity of the medium at the lead tip.

    abstract::Radiofrequency induced pacemaker lead tip heating is one of the main reasons magnetic resonance imaging (MRI) is contraindicated for patients with pacemakers. The objective of this work was to evaluate the dependence of pacemaker lead tip heating during MRI scanning on the electrical conductivity of the medium surroun...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23235

    authors: Langman DA,Goldberg IB,Judy J,Paul Finn J,Ennis DB

    更新日期:2012-08-01 00:00:00

  • High-resolution 3D proton spectroscopic imaging of the human brain at 3 T: SNR issues and application for anatomy-matched voxel sizes.

    abstract::In a systematic study on the interdependence of linewidth, signal-to-noise ratio (SNR), and spatial resolution in 3D proton spectroscopic imaging ((1)H-SI) at 3 T, we demonstrate reduced linewidths with increased spatial resolution due to reduced magnetic inhomogeneity within the brain. High-precision quantitative dat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10377

    authors: Gruber S,Mlynárik V,Moser E

    更新日期:2003-02-01 00:00:00

  • Phase-updated regularized SENSE for navigator-free multishot diffusion imaging.

    abstract:PURPOSE:Either SENSE+CG or POCS-ICE methods can be used to correct for motion-induced phase errors in navigator-free multishot diffusion imaging. SENSE+CG has the advantage of a fast convergence, however, occasionally the convergence can be unstable, thus degrading the image quality. POCS-ICE has a stable convergence a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26361

    authors: Hu Z,Ma X,Truong TK,Song AW,Guo H

    更新日期:2017-07-01 00:00:00

  • Bulk volume susceptibility difference between deoxyhemoglobin and oxyhemoglobin for HbA and HbS: A comparative study.

    abstract:PURPOSE:Sickle cell anemia is a blood disorder that alters the morphology and the oxygen affinity of the red blood cells. Cerebral oxygen extraction fraction measurements using quantitative BOLD contrast have been used for assessing inadequate oxygen delivery and the subsequent risk of ischemic stroke in sickle cell an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28668

    authors: Eldeniz C,Binkley MM,Fields M,Guilliams K,Ragan DK,Chen Y,Lee JM,Ford AL,An H

    更新日期:2021-01-21 00:00:00