Abstract:
:The aim of this study was to quantify changes in thoracic aortic wall shear stress (WSS) in asymptomatic patients with Marfan syndrome (MFS) compared with healthy controls. WSS in the thoracic aorta was quantified based on time-resolved 3D phase contrast MRI with three-directional velocity encoding (4D flow MRI, temporal resolution ∼44 ms, spatial resolution ∼2.5 mm) in 24 patients with confirmed MFS (age = 18 ± 12 years) and in 12 older healthy volunteers (age = 25 ± 3 years). Diameters of the thoracic aorta normalized to body surface area were similar for both groups. Peak systolic velocity, absolute WSS, time-averaged WSS, circumferential WSS, peak systolic WSS, and WSS eccentricity were calculated in eight analysis planes distributed along the thoracic aorta. Plane-wise comparison revealed significant differences between MFS patients and volunteers in the proximal ascending aorta for peak systolic velocities (1.11 ± 0.23 m/s vs. 1.34 ± 0.18 m/s, P = 0.004) and circumferential WSS (0.14 ± 0.03 N/m(2) vs. 0.11 ± 0.02 N/m(2), P = 0.007). WSS eccentricity was altered in most of the ascending aorta and proximal arch (P = 0.009-0.020). MFS patients demonstrated segmental differences in peak systolic WSS with a significantly higher WSS at the inner curvature in the proximal ascending aorta and at the anterior part in the more distal ascending aorta (P < 0.01). These findings indicate differences in WSS associated with MFS despite similar aortic dimensions compared to controls.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Geiger J,Arnold R,Herzer L,Hirtler D,Stankovic Z,Russe M,Langer M,Markl Mdoi
10.1002/mrm.24562subject
Has Abstractpub_date
2013-10-01 00:00:00pages
1137-44issue
4eissn
0740-3194issn
1522-2594journal_volume
70pub_type
杂志文章abstract::Dual labeled liposomes, carrying both paramagnetic and fluorescent lipids, were recently proposed as potent contrast agents for MR molecular imaging. These nanoparticles are coated with poly(ethylene glycol) (PEG) to increase their blood circulation half-life, which should allow extensive accumulation at the targeted ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21780
更新日期:2008-12-01 00:00:00
abstract::Chemically-fixed nervous tissues are well-suited for high-resolution, time-intensive MRI acquisitions without motion artifacts, such as those required for brain atlas projects, but the aldehyde fixatives used may significantly alter tissue MRI properties. To test this hypothesis, this study characterized the impact of...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21977
更新日期:2009-07-01 00:00:00
abstract:PURPOSE:Dipole antennas in ultrahigh field MRI have demonstrated advantages over more conventional designs. In this study, the fractionated dipole antenna is presented: a dipole where the legs are split into segments that are interconnected by capacitors or inductors. METHODS:A parameter study has been performed on di...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25596
更新日期:2016-03-01 00:00:00
abstract:PURPOSE:To improve the quality and speed of electron paramagnetic resonance imaging (EPRI) acquisition by combining a uniform sampling distribution with spinning gradient acquisition. THEORY AND METHODS:A uniform sampling distribution was derived for spinning gradient EPRI acquisition (uniform spinning sampling, USS) ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24712
更新日期:2014-02-01 00:00:00
abstract:PURPOSE:To characterize pseudo-continuous arterial spin labeling (pCASL) through simulations of spin inversion and to discuss suitable parameter settings for measuring cerebral perfusion. METHODS:Simulations of arterial spin inversion in pCASL were performed based on the Bloch equation. Both the labeling and the contr...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26805
更新日期:2018-03-01 00:00:00
abstract::This study demonstrates the feasibility of applying free-breathing, cardiac-gated, susceptibility-weighted fast spin-echo imaging together with black blood preparation and navigator-gated respiratory motion compensation for anatomically accurate T2* mapping of the heart. First, T2* maps are presented for oil phantoms ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22054
更新日期:2009-09-01 00:00:00
abstract::Stimulated-echo localized spectroscopy was combined with phase- and frequency-encoding gradients to obtain "zoom" or magnified images of specific organs in situ. The technique requires neither surface coils nor an imaging coil arrangement that exclusively isolates the target organ. This technique can be readily applie...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910050412
更新日期:1987-10-01 00:00:00
abstract:PURPOSE:To design, evaluate, and apply a bow tie antenna transceiver radiofrequency (RF) coil array tailored for cardiac MRI at 7.0 Tesla (T). METHODS:The radiofrequency (RF) coil array comprises 16 building blocks each containing a bow tie shaped λ/2-dipole antenna. Numerical simulations were used for transmission fi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25840
更新日期:2016-06-01 00:00:00
abstract::The chemical shift of water and fat resonances in proton MRI allows separation of water and fat signal from chemical shift encoded data. This work describes an automatic method that produces separate water and fat images as well as quantitative maps of fat signal fraction and T2* from complex multiecho gradient-recall...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.23185
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The purpose of this project was to construct a physical brain phantom for MRI, mimicking structure and T1 relaxation properties of white matter (WM) and gray matter (GM). METHODS:The phantom design comprised 2 compartments, 1 resembling the WM and 1 resembling the GM. Their T1 relaxation times, as assessed usi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27464
更新日期:2019-02-01 00:00:00
abstract:PURPOSE:Assessing the functionality of muscle fibers is essential to monitor both pathological and physiological processes. Here, we present a new method for accurate, quantitative measurement of muscle contraction with magnetic resonance imaging (MRI) using an electrical muscle stimulator (EMS), hence allowing the dir...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26154
更新日期:2017-02-01 00:00:00
abstract:PURPOSE:In contrast to conventional linear gradients, gradient coil arrays with arbitrary spatial dependency might experience strong mutual coupling. Although conventional gradient power amplifiers with feedback loop might compensate the effect of coupling, required voltages for the compensation are generally unknown a...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27768
更新日期:2019-09-01 00:00:00
abstract:PURPOSE:To develop a new parallel transmit (pTx) pulse design for simultaneous multiband (MB) excitation in order to tackle simultaneously the problems of transmit B1 (B1+) inhomogeneity and total radiofrequency (RF) power, so as to allow for optimal RF excitation when using MB pulses for slice acceleration for high an...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24828
更新日期:2013-09-01 00:00:00
abstract::It is shown that in vivo measurement of bile water apparent diffusion coefficient (ADC) by diffusion-weighted echo-planar imaging (EPI) in hamster gallbladder is possible providing motion artifact-free ADC values. These ADC values are used to estimate bile viscosity variation induced by normal diets, cholesterol galls...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/1522-2594(200006)43:6<854::aid-mrm11>3.0.c
更新日期:2000-06-01 00:00:00
abstract::The echo-planar k-space trajectory can be used as the basis for any two-dimensional selective pulse. The main application is spectral-spatial pulses, which must be based on the echo-planar trajectory. In this paper we show how echo-planar spin-echo (EPSE) pulses may be designed. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910290609
更新日期:1993-06-01 00:00:00
abstract::T2 measurements of 31P NMR signals of ATP using the Hahn 90 degrees-180 degrees spin-echo sequence imply difficulties whenever the 180 degrees pulse angle is not completely perfect. The reason for this finding is the crucial influence of the J-couplings of the ATP signals which result in intensity modulations and cons...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910300122
更新日期:1993-07-01 00:00:00
abstract:PURPOSE:To analyze the effect of B0 field drift on multivoxel MR spectroscopic imaging and to propose an approach for its correction. THEORY AND METHODS:It is shown, both theoretically and in a phantom, that for ∼30 min acquisitions a linear B0 drift (∼0.1 ppm/h) will cause localization errors that can reach several v...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24536
更新日期:2013-10-01 00:00:00
abstract:PURPOSE:Sickle cell anemia is a blood disorder that alters the morphology and the oxygen affinity of the red blood cells. Cerebral oxygen extraction fraction measurements using quantitative BOLD contrast have been used for assessing inadequate oxygen delivery and the subsequent risk of ischemic stroke in sickle cell an...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28668
更新日期:2021-01-21 00:00:00
abstract::In this work a model-free arterial spin labeling (ASL) quantification approach for measuring cerebral blood flow (CBF) and arterial blood volume (aBV) is proposed. The method is based on the acquisition of a train of multiple images following the labeling scheme. Perfusion is obtained using deconvolution in a manner s...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20784
更新日期:2006-02-01 00:00:00
abstract::A simple iterative algorithm, termed deconvolution-interpolation gridding (DING), is presented to address the problem of reconstructing images from arbitrarily-sampled k-space. The new algorithm solves a sparse system of linear equations that is equivalent to a deconvolution of the k-space with a small window. The dec...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21095
更新日期:2006-12-01 00:00:00
abstract::If magnetic resonance spectroscopy (MRS) is to become a useful tool in clinical medicine, it will be necessary to find reliable methods for analyzing and classifying MRS data. Automated methods are desirable because they can remove user bias and can deal with large amounts of data, allowing the use of all the availabl...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910350608
更新日期:1996-06-01 00:00:00
abstract:PURPOSE:To obtain multicontrast images including fat-suppressed contrast image, a novel multicontrast imaging method using an SSFP sequence with alternating RF flip angles is proposed. METHODS:The proposed method uses the balanced SSFP sequence with 2 flip angles. In general, the conventional balanced SSFP sequence ha...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27342
更新日期:2018-10-01 00:00:00
abstract::Prepolarized MRI uses pulsed magnetic fields to produce MR images by polarizing the sample at one field strength (approximately 0.5 T) before imaging at a much lower field (approximately 50 mT). Contrast reflecting the T(1) of the sample at an intermediate field strength is achieved by polarizing the sample and then a...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20910
更新日期:2006-06-01 00:00:00
abstract::Brain water proton (1H2O) longitudinal relaxation time constants (T1) were obtained from three healthy individuals at magnetic field strengths (B0) of 0.2 Tesla (T), 1.0T, 1.5T, 4.0T, and 7.0T. A 5-mm midventricular axial slice was sampled using a modified Look-Locker technique with 1.5 mm in-plane resolution, and 32 ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21122
更新日期:2007-02-01 00:00:00
abstract::The differential effects of high temperature on 9L rat gliosarcoma cells cultured in two distinctive forms, namely, anchored monolayer cells and multicellular spheroids, were investigated using 31P nuclear magnetic resonance spectroscopy. The critical temperatures resulting in irreversible changes in cellular energeti...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910190233
更新日期:1991-06-01 00:00:00
abstract::MR acoustic, or sound, noise due to gradient pulsing has been one of the problems in MRI, both in patient scanning as well as in many areas of psychiatric and neuroscience research, such as brain fMRI. Especially in brain fMRI, sound noise is one of the serious noise sources that obscures the small signals obtainable ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910390224
更新日期:1998-02-01 00:00:00
abstract::The presence of macroscopic vessels within the tumor region is a potential confounding factor in MR-based dynamic susceptibility contrast (DSC)-enhanced glioma grading. In order to distinguish between such vessels and the elevated cerebral blood volume (CBV) of brain tumors, we propose a vessel segmentation technique ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21944
更新日期:2009-05-01 00:00:00
abstract:PURPOSE:A systematic study of the short-term and long-term variability of regional alveolar partial pressure of oxygen tension (pA O2 ) measurements using (3) He magnetic resonance imaging was presented. Additionally, the repeatability of the average evaluated pA O2 was compared with that of the standard pulmonary func...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24604
更新日期:2013-12-01 00:00:00
abstract::The recently developed technique of gradient, high-resolution magic-angle spinning NMR (g-hr-MAS-NMR) spectroscopy was applied to the study of ex vivo human lipoma and liposarcoma tissue. Compared with conventional 1H-NMR, the g-hr-MAS method yielded a large improvement in spectral resolution and permitted the detecti...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910380307
更新日期:1997-09-01 00:00:00
abstract:PURPOSE:To evaluate proton density fat fraction (PDFF) and R2* as markers of bone marrow composition and structure in inflamed bone in patients with spondyloarthritis. METHODS:Phantoms containing fat, water, and trabecular bone were constructed with proton density fat fraction (PDFF) and bone mineral density (BMD) val...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26729
更新日期:2018-02-01 00:00:00