Intersubject specific absorption rate variability analysis through construction of 23 realistic body models for prostate imaging at 7T.

Abstract:

PURPOSE:For ultrahigh field (UHF) MRI, the expected local specific absorption rate (SAR) distribution is usually calculated by numerical simulations using a limited number of generic body models and adding a safety margin to take into account intersubject variability. Assessment of this variability with a large model database would be desirable. In this study, a procedure to create such a database with accurate subject-specific models is presented. Using 23 models, intersubject variability is investigated for prostate imaging at 7T with an 8-channel fractionated dipole antenna array with 16 receive loops. METHOD:From Dixon images of a volunteer acquired at 1.5T with a mockup array in place, an accurate dielectric model is built. Following this procedure, 23 subject-specific models for local SAR assessment at 7T were created enabling an extensive analysis of the intersubject B1+ and peak local SAR variability. RESULTS:For the investigated setup, the maximum possible peak local SAR ranges from 2.6 to 4.6 W/kg for 8 × 1 W input power. The expected peak local SAR values represent a Gaussian distribution ( μ / σ = 2.29 / 0.29 W/kg) with realistic prostate-shimmed phase settings and a gamma distribution Γ(24,0.09) with multidimensional radiofrequency pulses. Prostate-shimmed phase settings are similar for all models. Using 1 generic phase setting, average B1+ reduction is 7%. Using only 1 model, the required safety margin for intersubject variability is 1.6 to 1.8. CONCLUSION:The presented procedure allows for the creation of a customized model database. The results provide valuable insights into B1+ and local SAR variability. Recommended power thresholds per channel are 3.1 W with phase shimming on prostate or 2.6 W for multidimensional pulses.

journal_name

Magn Reson Med

authors

Meliadò EF,van den Berg CAT,Luijten PR,Raaijmakers AJE

doi

10.1002/mrm.27518

subject

Has Abstract

pub_date

2019-03-01 00:00:00

pages

2106-2119

issue

3

eissn

0740-3194

issn

1522-2594

journal_volume

81

pub_type

杂志文章
  • Enhancement of respiratory navigator-gated three-dimensional spoiled gradient-recalled echo sequence with variable flip angle scheme.

    abstract:PURPOSE:To develop and demonstrate the feasibility of a new technique for respiratory-gated, fat-suppressed, three-dimensional spoiled gradient-recalled echo (3D-SPGR) with navigator gating for more accurate and robust motion detection. METHODS:A navigator-gated 3D-SPGR technique was modified to include a wait period ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24902

    authors: Iwadate Y,Brau AC,Vasanawala SS,Kabasawa H

    更新日期:2014-07-01 00:00:00

  • Inversion recovery radial MRI with interleaved projection sets.

    abstract::The radial trajectory has found applications in cardiac imaging because of its resilience to undersampling and motion artifacts. Recent work has shown that interleaved and weighted radial imaging can produce images with multiple contrasts from a single data set. This feature was investigated for inversion recovery ima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20865

    authors: Peters DC,Botnar RM,Kissinger KV,Yeon SB,Appelbaum EA,Manning WJ

    更新日期:2006-05-01 00:00:00

  • The uncommon longitudinal relaxation dispersion of human brain white matter.

    abstract::Human brain white matter exhibits an uncommonly strong dispersion of 1/T1 at high fields. An additional relaxation pathway via the myelin lipids, which are not directly visible to medical NMR due to their fast T2 decay, is proposed. Relaxation dispersion data are successfully analyzed on the basis of this model. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910090319

    authors: Fischer HW,Van Haverbeke Y,Schmitz-Feuerhake I,Muller RN

    更新日期:1989-03-01 00:00:00

  • The importance of correcting for signal drift in diffusion MRI.

    abstract:PURPOSE:To investigate previously unreported effects of signal drift as a result of temporal scanner instability on diffusion MRI data analysis and to propose a method to correct this signal drift. METHODS:We investigated the signal magnitude of non-diffusion-weighted EPI volumes in a series of diffusion-weighted imag...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26124

    authors: Vos SB,Tax CM,Luijten PR,Ourselin S,Leemans A,Froeling M

    更新日期:2017-01-01 00:00:00

  • Introduction of the snake antenna array: Geometry optimization of a sinusoidal dipole antenna for 10.5T body imaging with lower peak SAR.

    abstract:PURPOSE:To improve imaging performance for body MRI with a local transmit array at 10.5T, the geometry of a dipole antenna was optimized to achieve lower peak specific absorption rate (SAR) levels and a more uniform transmit profile. METHODS:Electromagnetic simulations on a phantom were used to evaluate the SAR and ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28297

    authors: Steensma B,van de Moortele PF,Ertürk A,Grant A,Adriany G,Luijten P,Klomp D,van den Berg N,Metzger G,Raaijmakers A

    更新日期:2020-11-01 00:00:00

  • Dynamic glucose enhanced (DGE) MRI for combined imaging of blood-brain barrier break down and increased blood volume in brain cancer.

    abstract:PURPOSE:Recently, natural d-glucose was suggested as a potential biodegradable contrast agent. The feasibility of using d-glucose for dynamic perfusion imaging was explored to detect malignant brain tumors based on blood brain barrier breakdown. METHODS:Mice were inoculated orthotopically with human U87-EGFRvIII gliom...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25995

    authors: Xu X,Chan KW,Knutsson L,Artemov D,Xu J,Liu G,Kato Y,Lal B,Laterra J,McMahon MT,van Zijl PC

    更新日期:2015-12-01 00:00:00

  • Image reconstruction using a gradient impulse response model for trajectory prediction.

    abstract:PURPOSE:Gradient imperfections remain a challenge in MRI, especially for sequences relying on long imaging readouts. This work aims to explore image reconstruction based on k-space trajectories predicted by an impulse response model of the gradient system. THEORY AND METHODS:Gradient characterization was performed twi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25841

    authors: Vannesjo SJ,Graedel NN,Kasper L,Gross S,Busch J,Haeberlin M,Barmet C,Pruessmann KP

    更新日期:2016-07-01 00:00:00

  • B1AC-MAMBA: B1 array combined with multiple-acquisition micro B0 array parallel magnetic resonance imaging.

    abstract::The combination of an in-plane B(1) sensitivity encoding (SENSE) technique with a simultaneous multiple-slice B(0) field step technique (multiple-acquisition micro B(0) array (MAMBA)) has produced high scan time reduction factors (R < or = 8). In this study, two slices were acquired simultaneously in combination with ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10464

    authors: Paley MN,Lee KJ,Wild JM,Fichele S,Whitby EH,Wilkinson ID,Van Beek EJ,Griffiths PD

    更新日期:2003-06-01 00:00:00

  • Coronary MR angiography using image-based respiratory motion compensation with inline correction and fixed gating efficiency.

    abstract:PURPOSE:The purpose of this study was to evaluate a new inline motion compensation approach called image-based navigation with Constant Respiratory efficiency UsIng Single End-expiratory threshold (iNAV-CRUISE) for coronary MR angiography (CMRA). METHODS:The CRUISE gating technique was combined with iNAV motion correc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26678

    authors: Henningsson M,Smink J,van Ensbergen G,Botnar R

    更新日期:2018-01-01 00:00:00

  • Safety and technique of ferumoxytol administration for MRI.

    abstract::Ferumoxytol is an ultrasmall superparamagnetic iron oxide agent marketed for the treatment of anemia. There has been increasing interest in its properties as an MRI contrast agent as well as greater awareness of its adverse event profile. This mini-review summarizes the current state of knowledge of the risks of ferum...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.26151

    authors: Vasanawala SS,Nguyen KL,Hope MD,Bridges MD,Hope TA,Reeder SB,Bashir MR

    更新日期:2016-05-01 00:00:00

  • Proton NMR study of the state of water in fibrin gels, plasma, and blood clots.

    abstract::A proton NMR relaxation and pulsed field gradient self-diffusion study of water in fibrin gels, plasma, and blood clots has been performed with special emphasis on the effect of the sol-gel and shrinkage transitions. Deuteron NMR in fibrin gels was also studied to supplement the proton data. It is shown that a measure...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910140111

    authors: Blinc A,Lahajnar G,Blinc R,Zidansek A,Sepe A

    更新日期:1990-04-01 00:00:00

  • Investigating temporal fluctuations in tumor vasculature with combined carbogen and ultrasmall superparamagnetic iron oxide particle (CUSPIO) imaging.

    abstract::A combined carbogen ultrasmall superparamagnetic iron oxide (USPIO) imaging protocol was developed and applied in vivo in two murine colorectal tumor xenograft models, HCT116 and SW1222, with established disparate vascular morphology, to investigate whether additional information could be extracted from the combinatio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22779

    authors: Burrell JS,Walker-Samuel S,Baker LC,Boult JK,Ryan AJ,Waterton JC,Halliday J,Robinson SP

    更新日期:2011-07-01 00:00:00

  • Sources of functional apparent diffusion coefficient changes investigated by diffusion-weighted spin-echo fMRI.

    abstract::The mechanism behind previously observed changes in the apparent diffusion coefficient (ADC) during brain activation is not well understood. Therefore, we investigated the signal source and spatial specificity of functional magnetic resonance imaging (fMRI) ADC changes systematically in the visual cortex of cats using...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21074

    authors: Jin T,Zhao F,Kim SG

    更新日期:2006-12-01 00:00:00

  • Real-time MR elastography for viscoelasticity quantification in skeletal muscle during dynamic exercises.

    abstract:PURPOSE:To develop and test real-time MR elastography for viscoelastic parameter quantification in skeletal muscle during dynamic exercises. METHODS:In 15 healthy participants, 6 groups of lower-leg muscles (tibialis anterior, tibialis posterior, peroneus, extensor digitorum longus, soleus, gastrocnemius) were investi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28095

    authors: Schrank F,Warmuth C,Görner S,Meyer T,Tzschätzsch H,Guo J,Uca YO,Elgeti T,Braun J,Sack I

    更新日期:2020-07-01 00:00:00

  • Use of a projection reconstruction method to decrease motion sensitivity in diffusion-weighted MRI.

    abstract::Diffusion-weighted MRI is a clinically useful technique, but its utility is compromised by high sensitivity to patient motion. Use of radial-scan data acquisition and projection reconstruction, rather than the conventional Fourier imaging method, can substantially reduce the sensitivity to global translational motion ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290619

    authors: Gmitro AF,Alexander AL

    更新日期:1993-06-01 00:00:00

  • The use of band-selectable digital filtering in magnetic resonance image enhancement.

    abstract::Manipulation of the data describing two-dimensional magnetic resonance (MR) images can be used to zoom an image, decrease image noise and artifacts by modeling, or emphasize object edges in the field of view. In this paper, a two-dimensional band-selectable digital filtering (2D-BSDF) technique is detailed. This can b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910090307

    authors: Mitchell DK,Nichols ST,Smith MR,Scott K

    更新日期:1989-03-01 00:00:00

  • Accurate quantification of in vivo 31P NMR signals using the variable projection method and prior knowledge.

    abstract::Free induction decay signals are analyzed by fitting a model function directly in the time domain. No starting values are needed for linear model parameters, and omission of corrupted data points poses no problems. A significant gain of accuracy is achieved by imposing prior knowledge about the model parameters. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060111

    authors: van der Veen JW,de Beer R,Luyten PR,van Ormondt D

    更新日期:1988-01-01 00:00:00

  • Compensation of breathing motion artifacts for MRI with continuously moving table.

    abstract::Breathing motion is one of the main sources of artifacts in MRI acquisitions that can severely impair diagnosis. In MRI with continuously moving table, the application of common motion compensation approaches such as breath holding or the synchronization of the measurement with the breathing motion can be problematic....

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22162

    authors: Honal M,Leupold J,Huff S,Baumann T,Ludwig U

    更新日期:2010-03-01 00:00:00

  • Measurement of 129Xe gas apparent diffusion coefficient anisotropy in an elastase-instilled rat model of emphysema.

    abstract::Hyperpolarized noble gas ((3)He and (129)Xe) apparent diffusion coefficient (ADC) measurements have shown remarkable sensitivity to microstructural (i.e., alveolar) changes in the lung, particularly emphysema. The ADC of hyperpolarized noble gases depends strongly on the diffusion time (Δ), and (3)He ADC has been show...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24224

    authors: Boudreau M,Xu X,Santyr GE

    更新日期:2013-01-01 00:00:00

  • MR coil design for simultaneous tip tracking and curvature delineation of a catheter.

    abstract::In active catheter tracking, small RF coils are attached to the catheter for localization. For interactive catheter steering at vessel branchings, it is necessary to visualize not only a single point near the catheter tip but also the entire shape and orientation of the catheter's distal end. Therefore, a 35-mm-long t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20108

    authors: Zuehlsdorff S,Umathum R,Volz S,Hallscheidt P,Fink C,Semmler W,Bock M

    更新日期:2004-07-01 00:00:00

  • Continuous assessment of relative cerebral blood volume in transient ischemia using steady state susceptibility-contrast MRI.

    abstract::The utility of a noninvasive steady state susceptibility-contrast MRI technique for continuous measurement of relative cerebral blood volume (rCBV) during global transient ischemia and subsequent hyperemia in a feline ischemia model is demonstrated. The measurements were obtained during a 10-min period of occlusion an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350207

    authors: Hamberg LM,Boccalini P,Stranjalis G,Hunter GJ,Huang Z,Halpern E,Weisskoff RM,Moskowitz MA,Rosen BR

    更新日期:1996-02-01 00:00:00

  • Analysis of the evolution of focal cerebral ischemia in the rat using the eigenimage filter.

    abstract::The eigenimage filter was used to evaluate the results of a MRI study of cerebral ischemia in a rat model. This linear filter segments a desired feature in an image sequence from other features which may interfere with its observation. The animals were imaged temporally, after occlusion of the middle cerebral artery, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910260207

    authors: Peck DJ,Spickler EM,Knight RA,Hearshen DO,Windham JP

    更新日期:1992-08-01 00:00:00

  • SENSE reconstruction for multiband EPI including slice-dependent N/2 ghost correction.

    abstract:PURPOSE:Sensitivity encoding (SENSE) reconstruction of multiband echo planar imaging (EPI) may cause artifacts when simultaneously excited slices require different phase correction to remove the EPI-specific ghost shifted by half of the matrix size (N). We propose a simplified solution of this problem that combines SEN...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25915

    authors: Hennel F,Buehrer M,von Deuster C,Seuven A,Pruessmann KP

    更新日期:2016-09-01 00:00:00

  • Diffusion-weighted hyperpolarized 129Xe MRI in healthy volunteers and subjects with chronic obstructive pulmonary disease.

    abstract::Given its greater availability and lower cost, (129) Xe apparent diffusion coefficient (ADC) MRI offers an alternative to (3) He ADC MRI. To demonstrate the feasibility of hyperpolarized (129) Xe ADC MRI, we present results from healthy volunteers (HV), chronic obstructive pulmonary disease (COPD) subjects, and age-ma...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22697

    authors: Kaushik SS,Cleveland ZI,Cofer GP,Metz G,Beaver D,Nouls J,Kraft M,Auffermann W,Wolber J,McAdams HP,Driehuys B

    更新日期:2011-04-01 00:00:00

  • Phase constrained encoding (PACE): a technique for MRI in large static field inhomogeneities.

    abstract::In spin echo imaging, magnetization is assigned to a location defined by its frequency of rotation. In the presence of a static magnetic field inhomogeneity, however, this location does not correspond to the true location of the magnetization. This paper describes a magnetic resonance imaging technique called phase co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330407

    authors: Kim JK,Plewes DB,Henkelman RM

    更新日期:1995-04-01 00:00:00

  • The effect of reducing repetition time TR on the measurement of liver R2 for the purpose of measuring liver iron concentration.

    abstract::The effects of reducing the pulse repetition time from 2500 ms to 1000 ms when using spin-density-projection-assisted R2-magnetic resonance imaging for the purpose of measuring liver iron concentration were evaluated. Repeated liver R2 measurements were made using both protocols on 60 subjects with liver iron concentr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22712

    authors: Pavitt HL,Aydinok Y,El-Beshlawy A,Bayraktaroglu S,Ibrahim AS,Hamdy MM,Pang W,Sharples C,St Pierre TG

    更新日期:2011-05-01 00:00:00

  • NMR visibility studies of N-delta proton of proximal histidine in deoxyhemoglobin in lysed and intact red cells.

    abstract::Recent in vivo 1H MRS studies of muscle oxygen levels by means of myoglobin (Mb) oxygenation have necessitated an investigation of the possible contamination from deoxy-hemoglobin (Hb). To determine the contribution of Hb in these NMR measurements, we studied the NMR visibility of histidyl N-delta proton of Hb in lyse...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300616

    authors: Wang DJ,Nioka S,Wang Z,Leigh JS,Chance B

    更新日期:1993-12-01 00:00:00

  • Diffusional kurtosis imaging: the quantification of non-gaussian water diffusion by means of magnetic resonance imaging.

    abstract::A magnetic resonance imaging method is presented for quantifying the degree to which water diffusion in biologic tissues is non-Gaussian. Since tissue structure is responsible for the deviation of water diffusion from the Gaussian behavior typically observed in homogeneous solutions, this method provides a specific me...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20508

    authors: Jensen JH,Helpern JA,Ramani A,Lu H,Kaczynski K

    更新日期:2005-06-01 00:00:00

  • Intracellular bimodal nanoparticles based on quantum dots for high-field MRI at 21.1 T.

    abstract::Multimodal, biocompatible contrast agents for high magnetic field applications represent a new class of nanomaterials with significant potential for tracking of fluorescence and MR in vitro and vivo. Optimized for high-field MR applications-including biomedical imaging at 21.1 T, the highest magnetic field available f...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22441

    authors: Rosenberg JT,Kogot JM,Lovingood DD,Strouse GF,Grant SC

    更新日期:2010-09-01 00:00:00

  • A computer simulation of nuclear magnetic resonance imaging.

    abstract::A modular, user-friendly computer simulation of NMR imaging was created for the DEC VAX computer. This simulation is novel in that complex imaging phenomena, such as chemical shifts and flow, may be easily studied. Other features include spin warp and backprojection imaging, movie generation, and simulation of image c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030302

    authors: Summers RM,Axel L,Israel S

    更新日期:1986-06-01 00:00:00