Moment and direction of the spoiler gradient for effective artifact suppression in RF-spoiled gradient echo imaging.

Abstract:

:Radiofrequency (RF) -spoiled gradient echo sequences were developed with the aim to produce images with T(1) weighted contrast within short acquisition time. Over the past two decades, this type of sequence has proven to be a robust technique and represents a reliable workhorse in clinical MRI. This study presents an analysis of ghost artifacts, which appear occasionally in RF-spoiled gradient echo images. It is demonstrated that the artifacts result from intrinsically emerging signal oscillations, which can be damped down by the application of spoiler gradients.

journal_name

Magn Reson Med

authors

Leupold J,Hennig J,Scheffler K

doi

10.1002/mrm.21614

subject

Has Abstract

pub_date

2008-07-01 00:00:00

pages

119-27

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

60

pub_type

杂志文章
  • Perfusion-based functional magnetic resonance imaging with single-shot RARE and GRASE acquisitions.

    abstract::For perfusion-based functional magnetic resonance imaging, the previously introduced flow-sensitive alternating inversion recovery (FAIR) technique is combined with single-shot RARE (rapid acquisition with relaxation enhancement) and GRASE (gradient and spin echo) imaging sequences. The advantages of these sequences c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199901)41:1<132::aid-mrm18

    authors: Crelier GR,Hoge RD,Munger P,Pike GB

    更新日期:1999-01-01 00:00:00

  • Characterization of white matter alterations in phenylketonuria by magnetic resonance relaxometry and diffusion tensor imaging.

    abstract::A multimodal MR study including relaxometry, diffusion tensor imaging (DTI), and MR spectroscopy was performed on patients with classical phenylketonuria (PKU) and matched controls, to improve our understanding of white matter (WM) lesions. Relaxometry yields information on myelin loss or malformation and may substant...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21422

    authors: Vermathen P,Robert-Tissot L,Pietz J,Lutz T,Boesch C,Kreis R

    更新日期:2007-12-01 00:00:00

  • T2 of endotoxin lung injury with and without methylprednisolone treatment.

    abstract::NMR relaxation times (T1 and T2) and the water content (WC) of in vitro rat lungs were measured during the course of endotoxin lung injury in rats. Measurements of normal lungs, untreated endotoxin-injured lungs, and endotoxin-injured lungs treated with methylprednisolone (MPSL) were compared. The untreated endotoxin ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910150204

    authors: Shioya S,Haida M,Tsuji C,Ono Y,Miyairi A,Fukuzaki M,Ohta Y,Yamabayashi H

    更新日期:1990-08-01 00:00:00

  • Iterative correction of RF envelope distortion with GRATER-measured waveforms.

    abstract:PURPOSE:To develop and evaluate a method for RF envelope correction without extra hardware or synchronization. METHODS:Transmitted RF waveforms are measured through a simple pulse sequence called the gradient reversal approach to evaluate RF (GRATER). The measured RF waveforms are used to compute predistorted RF wavef...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27930

    authors: Landes VL,Nayak KS

    更新日期:2020-01-01 00:00:00

  • A torque balance measurement of anisotropy of the magnetic susceptibility in white matter.

    abstract:PURPOSE:Recent MRI studies have suggested that the magnetic susceptibility of white matter (WM) in the human brain is anisotropic, providing a new contrast mechanism for the visualization of fiber bundles and allowing the extraction of cellular compartment-specific information. This study provides an independent confir...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25524

    authors: van Gelderen P,Mandelkow H,de Zwart JA,Duyn JH

    更新日期:2015-11-01 00:00:00

  • Accelerated cardiac magnetic resonance imaging in the mouse using an eight-channel array at 9.4 Tesla.

    abstract::MRI has become an important tool to noninvasively assess global and regional cardiac function, infarct size, or myocardial blood flow in surgically or genetically modified mouse models of human heart disease. Constraints on scan time due to sensitivity to general anesthesia in hemodynamically compromised mice frequent...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22605

    authors: Schneider JE,Lanz T,Barnes H,Stork LA,Bohl S,Lygate CA,Ordidge RJ,Neubauer S

    更新日期:2011-01-01 00:00:00

  • Aortic wall shear stress in Marfan syndrome.

    abstract::The aim of this study was to quantify changes in thoracic aortic wall shear stress (WSS) in asymptomatic patients with Marfan syndrome (MFS) compared with healthy controls. WSS in the thoracic aorta was quantified based on time-resolved 3D phase contrast MRI with three-directional velocity encoding (4D flow MRI, tempo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24562

    authors: Geiger J,Arnold R,Herzer L,Hirtler D,Stankovic Z,Russe M,Langer M,Markl M

    更新日期:2013-10-01 00:00:00

  • Echo-time reduction for submillimeter resolution imaging with a 3D phase encode time reduced acquisition method.

    abstract::To achieve optimal image quality and highest spatial resolution for inner ear imaging with a 3D gradient echo sequence, it is necessary to minimize susceptibility dephasing effects by using very short TE. Fractional RF pulses and echoes can yield short TE for moderate spatial resolution; however, for voxel size of les...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330112

    authors: Ying K,Schmalbrock P,Clymer B

    更新日期:1995-01-01 00:00:00

  • Two-dimensional imaging in a lightweight portable MRI scanner without gradient coils.

    abstract:PURPOSE:As the premiere modality for brain imaging, MRI could find wider applicability if lightweight, portable systems were available for siting in unconventional locations such as intensive care units, physician offices, surgical suites, ambulances, emergency rooms, sports facilities, or rural healthcare sites. METH...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25147

    authors: Cooley CZ,Stockmann JP,Armstrong BD,Sarracanie M,Lev MH,Rosen MS,Wald LL

    更新日期:2015-02-01 00:00:00

  • Accurate quantification of in vivo 31P NMR signals using the variable projection method and prior knowledge.

    abstract::Free induction decay signals are analyzed by fitting a model function directly in the time domain. No starting values are needed for linear model parameters, and omission of corrupted data points poses no problems. A significant gain of accuracy is achieved by imposing prior knowledge about the model parameters. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060111

    authors: van der Veen JW,de Beer R,Luyten PR,van Ormondt D

    更新日期:1988-01-01 00:00:00

  • Quantitative 1 H MRI and MRS of fatty acid composition.

    abstract::Adipose tissue as well as other depots of fat (triglycerides) are increasingly being recognized as active contributors to the human function and metabolism. In addition to the fat concentration, also the fatty acid chemical composition (FAC) of the triglyceride molecules may play an important part in diseases such as ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.28471

    authors: Peterson P,Trinh L,Månsson S

    更新日期:2021-01-01 00:00:00

  • Evaluation of hepatic steatosis before liver transplantation in ex vivo by volumetric quantitative PDFF-MRI.

    abstract:PURPOSE:Over the last two decades, extended criteria have promoted an increased number of donor livers available for liver transplantation. But posttransplant graft loss is still a major concern. Macrovesicular hepatic steatosis (MHS) is recognized as the most significant prognostic histologic parameter in predicting p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28592

    authors: Chen G,Jiang J,Wang X,Yang M,Xie Y,Guo H,Tang H,Zhou L,Hu D,Kamel IR,Chen Z,Li Z

    更新日期:2020-11-16 00:00:00

  • A pitfall associated with determination of transverse relaxation times of the 31P NMR signals of ATP using the Hahn spin-echo.

    abstract::T2 measurements of 31P NMR signals of ATP using the Hahn 90 degrees-180 degrees spin-echo sequence imply difficulties whenever the 180 degrees pulse angle is not completely perfect. The reason for this finding is the crucial influence of the J-couplings of the ATP signals which result in intensity modulations and cons...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300122

    authors: Jung WI,Straubinger K,Bunse M,Widmaier S,Schick F,Küper K,Dietze G,Lutz O

    更新日期:1993-07-01 00:00:00

  • The importance of correcting for signal drift in diffusion MRI.

    abstract:PURPOSE:To investigate previously unreported effects of signal drift as a result of temporal scanner instability on diffusion MRI data analysis and to propose a method to correct this signal drift. METHODS:We investigated the signal magnitude of non-diffusion-weighted EPI volumes in a series of diffusion-weighted imag...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26124

    authors: Vos SB,Tax CM,Luijten PR,Ourselin S,Leemans A,Froeling M

    更新日期:2017-01-01 00:00:00

  • Separation and quantification of lactate and lipid at 1.3 ppm by diffusion-weighted magnetic resonance spectroscopy.

    abstract:PURPOSE:To separate the spectrally overlapped lactate and lipid signals at 1.3 ppm using diffusion-weighted magnetic resonance spectroscopy (DW-MRS) based on their large diffusivity difference. METHODS:DW-MRS was applied to the gel phantoms containing lactate and lipid droplets, and to the rat brain tumors. Lactate an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26144

    authors: Wang AM,Leung GK,Kiang KM,Chan D,Cao P,Wu EX

    更新日期:2017-02-01 00:00:00

  • Total brain N-acetylaspartate concentration in normal, age-grouped females: quantitation with non-echo proton NMR spectroscopy.

    abstract::The intra-individual and inter-individual variations of the global N-acetylaspartate (NAA) concentration were measured in a cohort of five 42+/-5 year-old normal females. The total NAA signal from the whole head was obtained with non-localized non-echo proton spectroscopy (1H-MRS) and converted into absolute mole amou...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.1910400506

    authors: Gonen O,Viswanathan AK,Catalaa I,Babb J,Udupa J,Grossman RI

    更新日期:1998-11-01 00:00:00

  • CEST MRI quantification procedures for breast cancer treatment-related lymphedema therapy evaluation.

    abstract:PURPOSE:To quantify chemical exchange saturation transfer contrast in upper extremities of participants with lymphedema before and after standardized lymphatic mobilization therapy using correction procedures for B0 and B1 heterogeneity, and T1 relaxation. METHODS:Females with (n = 12) and without (n = 17) breast canc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28031

    authors: Crescenzi R,Donahue PMC,Mahany H,Lants SK,Donahue MJ

    更新日期:2020-05-01 00:00:00

  • A statistical approach to SENSE regularization with arbitrary k-space trajectories.

    abstract::SENSE reconstruction suffers from an ill-conditioning problem, which increasingly lowers the signal-to-noise ratio (SNR) as the reduction factor increases. Ill-conditioning also degrades the convergence behavior of iterative conjugate gradient reconstructions for arbitrary trajectories. Regularization techniques are o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21665

    authors: Ying L,Liu B,Steckner MC,Wu G,Wu M,Li SJ

    更新日期:2008-08-01 00:00:00

  • Dual-polarity slice-GRAPPA for concurrent ghost correction and slice separation in simultaneous multi-slice EPI.

    abstract:PURPOSE:A ghost correction strategy for Simultaneous Multi-Slice (SMS) EPI methods that provides improved ghosting artifact reduction compared to conventional methods is presented. Conventional Nyquist ghost correction methods for SMS-EPI rely on navigator data that contain phase errors from all slices in the simultane...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27113

    authors: Hoge WS,Setsompop K,Polimeni JR

    更新日期:2018-10-01 00:00:00

  • Comparison of blood oxygenation and cerebral blood flow effects in fMRI: estimation of relative oxygen consumption change.

    abstract::The most widely-used functional magnetic resonance imaging (fMRI) technique is based on the blood oxygenation level dependent (BOLD) effect, which requires at least partial uncoupling between cerebral blood flow (CBF) and oxygen consumption changes during increased mental activity. To compare BOLD and CBF effects duri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380110

    authors: Kim SG,Uğurbil K

    更新日期:1997-07-01 00:00:00

  • High-resolution 1 H-MRSI of the brain using short-TE SPICE.

    abstract:PURPOSE:To improve signal-to-noise ratio (SNR) for high-resolution spectroscopic imaging using a subspace-based technique known as SPectroscopic Imaging by exploiting spatiospectral CorrElation (SPICE). METHODS:The proposed method is based on a union-of-subspaces model of MRSI signals, which exploits the partial separ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26130

    authors: Ma C,Lam F,Ning Q,Johnson CL,Liang ZP

    更新日期:2017-02-01 00:00:00

  • Characterization of pseudo-continuous arterial spin labeling: Simulations and experimental validation.

    abstract:PURPOSE:To characterize pseudo-continuous arterial spin labeling (pCASL) through simulations of spin inversion and to discuss suitable parameter settings for measuring cerebral perfusion. METHODS:Simulations of arterial spin inversion in pCASL were performed based on the Bloch equation. Both the labeling and the contr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26805

    authors: Lorenz K,Mildner T,Schlumm T,Möller HE

    更新日期:2018-03-01 00:00:00

  • Three-dimensional reconstruction of limited-view projections for contrast-enhanced magnetic resonance angiography at high temporal and spatial resolution.

    abstract::The feasibility of reconstructing three-dimensional (3D) MRI data sets from limited-view projections is investigated in phantom and in vivo animal studies to improve the temporal resolution of magnetic resonance angiography without sacrificing spatial resolution. Thirty-two pairs of orthogonal biplane projections are ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20727

    authors: Huang Y,Gurr D,Wright GA

    更新日期:2006-01-01 00:00:00

  • Novel quadrature birdcage coil for a vertical B(0) field open MRI system.

    abstract::A birdcage coil possesses various intrinsic resonant modes. One of the modes produces sinusoidal current distribution around the rung elements of the birdcage and generates a highly uniform B(1) field in the transverse plane. Another mode is the end-ring resonant mode, in which there are no currents in the rungs of th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200010)44:4<633::aid-mrm18>3.0.c

    authors: Fujita H,Braum WO,Morich MA

    更新日期:2000-10-01 00:00:00

  • Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP).

    abstract::A new parallel imaging technique was implemented which can result in reduced image acquisition times in MRI. MR data is acquired in parallel using an array of receiver coils and then reconstructed simultaneously with multiple processors. The method requires the initial estimation of the 2D sensitivity profile of each ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200008)44:2<301::aid-mrm18>3.0.c

    authors: Kyriakos WE,Panych LP,Kacher DF,Westin CF,Bao SM,Mulkern RV,Jolesz FA

    更新日期:2000-08-01 00:00:00

  • Myocardial T2* mapping free of distortion using susceptibility-weighted fast spin-echo imaging: a feasibility study at 1.5 T and 3.0 T.

    abstract::This study demonstrates the feasibility of applying free-breathing, cardiac-gated, susceptibility-weighted fast spin-echo imaging together with black blood preparation and navigator-gated respiratory motion compensation for anatomically accurate T2* mapping of the heart. First, T2* maps are presented for oil phantoms ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22054

    authors: Heinrichs U,Utting JF,Frauenrath T,Hezel F,Krombach GA,Hodenius MA,Kozerke S,Niendorf T

    更新日期:2009-09-01 00:00:00

  • Q-space truncation and sampling in diffusion spectrum imaging.

    abstract:PURPOSE:To characterize the q-space truncation and sampling on the spin-displacement probability density function (PDF) in diffusion spectrum imaging (DSI). METHODS:DSI data were acquired using the MGH-USC connectome scanner (Gmax  = 300 mT/m) with bmax  = 30,000 s/mm2 , 17 × 17 × 17, 15 × 15 × 15 and 11 × 11 × 11 gri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26071

    authors: Tian Q,Rokem A,Folkerth RD,Nummenmaa A,Fan Q,Edlow BL,McNab JA

    更新日期:2016-12-01 00:00:00

  • Direct reconstruction of MR images from data acquired on a non-Cartesian grid using an equal-phase-line algorithm.

    abstract::The equal-phase line (EPL) algorithm is proposed as a means of allowing rapid Fourier transform (FT) reconstruction of MR image data acquired on a non-Cartesian grid. The pixels on the image are grouped according to their positions. The pixels in a group have the same phase in the complex exponential function -exp[j2p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10165

    authors: Qian Y,Lin J,Jin D

    更新日期:2002-06-01 00:00:00

  • Proteoglycan-induced changes in T1rho-relaxation of articular cartilage at 4T.

    abstract::Proteoglycan (PG) depletion-induced changes in T1rho (spin-lattice relaxation in rotating frame) relaxation and dispersion in articular cartilage were studied at 4T. Using a spin-lock cluster pre-encoded fast spin echo sequence, T1rho maps of healthy bovine specimens and specimens that were subjected to PG depletion w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1208

    authors: Akella SV,Regatte RR,Gougoutas AJ,Borthakur A,Shapiro EM,Kneeland JB,Leigh JS,Reddy R

    更新日期:2001-09-01 00:00:00

  • A magnetic shield for large-bore, high field magnets.

    abstract::An effective shield for the dc fringing fields produced by a large-bore, high field magnet intended for imaging and in vivo spectroscopy is presented. While limiting the extent of fringe fields, the shield has little effect on the homogeneity of the central field of the magnet. The effect of institutional safety polic...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910020506

    authors: Ewing JR,Timms W,Williams JE,Welch KM

    更新日期:1985-10-01 00:00:00