Effects of polar sampling in k-space.

Abstract:

:Magnetic resonance imaging allows numerous k-space sampling schemes such as cartesian, polar, spherical, and other non-rectilinear trajectories. Non-rectilinear MR acquisitions permit fast scan times and can suppress motion artifacts. Still, these sampling schemes may adversely affect the image characteristics due to aliasing. Here, the Fourier aliasing effects of uniform polar sampling, i.e., equally spaced radial and azimuthal samples, are explained from the principal point spread function (PSF). The principal PSF is determined by assuming equally spaced concentric ring samples in k-space. The radial effects such as replication, smearing, truncation artifacts, and sampling requirements, are characterized based on the PSF.

journal_name

Magn Reson Med

authors

Lauzon ML,Rutt BK

doi

10.1002/mrm.1910360617

subject

Has Abstract

pub_date

1996-12-01 00:00:00

pages

940-9

issue

6

eissn

0740-3194

issn

1522-2594

journal_volume

36

pub_type

杂志文章
  • Detection and volume determination of colonic tumors in Min mice by magnetic resonance micro-imaging.

    abstract::We applied MRI to the in vivo detection of spontaneous colorectal tumors in a unique mouse model, the Fox Chase Cancer Center (FCCC) ApcMIN mouse. Unlike other Min (multiple intestinal neoplasia) strains, FCCC ApcMIN animals develop an appreciable number of tumors in the large intestine, which makes them an appropriat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20175

    authors: Hensley HH,Chang WC,Clapper ML

    更新日期:2004-09-01 00:00:00

  • 1H and (31)P magnetization transfer studies of hindleg muscle in wild-type and creatine kinase-deficient mice.

    abstract::The authors addressed the hypothesis that interactions with creatine kinase (CK) play a role in the off-resonance magnetization transfer (MT) effect of creatine in skeletal muscle. Toward that aim, (1)H MT studies were done on hindleg muscle in wild-type mice and in transgenic mice, lacking cytoplasmic CK and/or mitoc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200005)43:5<657::aid-mrm7>

    authors: Kruiskamp MJ,van Vliet G,Nicolay K

    更新日期:2000-05-01 00:00:00

  • On the steady-state properties of actual flip angle imaging (AFI).

    abstract::AFI (actual flip angle imaging) represents an interesting approach to map the B(1) transmit fields by measuring the spatial variations of the effective flip angle. However, the accuracy of the technique relies on the adequate spoiling of transverse magnetization. In the present work configuration theory was employed t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21592

    authors: Nehrke K

    更新日期:2009-01-01 00:00:00

  • Efficient sample density estimation by combining gridding and an optimized kernel.

    abstract::The reconstruction of non-Cartesian k-space trajectories often requires the estimation of nonuniform sampling density. Particularly for 3D, this calculation can be computationally expensive. The method proposed in this work combines an iterative algorithm previously proposed by Pipe and Menon (Magn Reson Med 1999;41:1...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23041

    authors: Zwart NR,Johnson KO,Pipe JG

    更新日期:2012-03-01 00:00:00

  • Pulsatile flow artifacts in 3D magnetic resonance imaging.

    abstract::Some of the important features of how pulsatile flow generates artifacts in three-dimensional magnetic resonance imaging are analyzed and demonstrated. Time variations in the magnetic resonance signal during the heart cycle lead to more complex patterns of artifacts in 3D imaging than in 2D imaging. The appearance and...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300305

    authors: Frank LR,Buxton RB,Kerber CW

    更新日期:1993-09-01 00:00:00

  • Neurobehavioral effects among subjects exposed to high static and gradient magnetic fields from a 1.5 Tesla magnetic resonance imaging system--a case-crossover pilot study.

    abstract::The interactive use of magnetic resonance imaging (MRI) techniques is increasing in operating theaters. A study was performed on 17 male company volunteers to assess the neurobehavioral effects of exposure to magnetic fields from a 1.5 Tesla MRI system. The subjects' neurobehavioral performances on a neurobehavioral t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10604

    authors: de Vocht F,van-Wendel-de-Joode B,Engels H,Kromhout H

    更新日期:2003-10-01 00:00:00

  • Eddy current correction in diffusion-weighted imaging using pairs of images acquired with opposite diffusion gradient polarity.

    abstract::In echo-planar-based diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI), the evaluation of diffusion parameters such as apparent diffusion coefficients and anisotropy indices is affected by image distortions that arise from residual eddy currents produced by the diffusion-sensitizing gradients. Correc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10690

    authors: Bodammer N,Kaufmann J,Kanowski M,Tempelmann C

    更新日期:2004-01-01 00:00:00

  • Rapid acquisition of helium-3 and proton three-dimensional image sets of the human lung in a single breath-hold using compressed sensing.

    abstract:PURPOSE:To develop and validate a method for acquiring helium-3 ((3) He) and proton ((1) H) three-dimensional (3D) image sets of the human lung with isotropic spatial resolution within a 10-s breath-hold by using compressed sensing (CS) acceleration, and to assess the fidelity of undersampled images compared with fully...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25499

    authors: Qing K,Altes TA,Tustison NJ,Feng X,Chen X,Mata JF,Miller GW,de Lange EE,Tobias WA,Cates GD Jr,Brookeman JR,Mugler JP 3rd

    更新日期:2015-10-01 00:00:00

  • Feasibility and performance of breath-hold 3D true-FISP coronary MRA using self-calibrating parallel acquisition.

    abstract::Spatial resolution in 3D breath-hold coronary MR angiography (MRA) is limited by imaging time. The purpose of this work was to investigate the feasibility of improving the spatial resolution of coronary MRA using generalized autocalibrating partially parallel acquisition (GRAPPA) and fast imaging with steady state pre...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20153

    authors: Park J,McCarthy R,Li D

    更新日期:2004-07-01 00:00:00

  • Relaxation effects of ferucarbotran-labeled mesenchymal stem cells at 1.5T and 3T: discrimination of viable from lysed cells.

    abstract::Human mesenchymal stem cells (hMSCs) were labeled with Ferucarbotran by simple incubation and cultured for up to 14 d. Iron content was determined by spectrometry and the intracellular localization of the contrast agent uptake was studied by electron and confocal microscopy. At various time points after labeling, rang...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22011

    authors: Henning TD,Wendland MF,Golovko D,Sutton EJ,Sennino B,Malek F,Bauer JS,McDonald DM,Daldrup-Link H

    更新日期:2009-08-01 00:00:00

  • Effects of the acoustic noise of the gradient systems on fMRI: a study on auditory, motor, and visual cortices.

    abstract::MR acoustic, or sound, noise due to gradient pulsing has been one of the problems in MRI, both in patient scanning as well as in many areas of psychiatric and neuroscience research, such as brain fMRI. Especially in brain fMRI, sound noise is one of the serious noise sources that obscures the small signals obtainable ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390224

    authors: Cho ZH,Chung SC,Lim DW,Wong EK

    更新日期:1998-02-01 00:00:00

  • Cardiac and respiratory double self-gated cine MRI in the mouse at 7 T.

    abstract::ECG-gated cardiac MRI in the mouse is hindered by many technical difficulties in ECG signal recording inside static and variable high magnetic scanner fields. The present study proposes an alternative robust method of acquiring auto-gated cardiac and respiratory cine images in mouse heart. In our approach, a motion sy...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20815

    authors: Hiba B,Richard N,Janier M,Croisille P

    更新日期:2006-03-01 00:00:00

  • Correlation of spectroscopy and magnetization transfer imaging in the evaluation of demyelinating lesions and normal appearing white matter in multiple sclerosis.

    abstract::Magnetization transfer imaging (MT) and localized proton spectroscopy (1H-MRS) were utilized in the evaluation of lesions (high signal abnormalities on T2-weighted images) and normal-appearing white matter (NAWM) in multiple sclerosis (MS). Eleven patients with a clinical diagnosis of MS were independently evaluated w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320303

    authors: Hiehle JF Jr,Lenkinski RE,Grossman RI,Dousset V,Ramer KN,Schnall MD,Cohen JA,Gonzalez-Scarano F

    更新日期:1994-09-01 00:00:00

  • Response of choline metabolites to docetaxel therapy is quantified in vivo by localized (31)P MRS of human breast cancer xenografts and in vitro by high-resolution (31)P NMR spectroscopy of cell extracts.

    abstract::Choline-containing compounds (CCCs) are elevated in breast cancer, and detected in vivo by the (1)H MRS total choline (tCho) resonance (3.25 ppm) and the (31)P MRS phosphomonoester (PME) resonance (3.8 ppm). Both the tCho and PME resonances decrease early after initiation of successful therapy. The single major compon...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21333

    authors: Morse DL,Raghunand N,Sadarangani P,Murthi S,Job C,Day S,Howison C,Gillies RJ

    更新日期:2007-08-01 00:00:00

  • In vivo time course studies of the tissue responses to resorbable polylactic acid implants by means of MRI.

    abstract::Magnetic resonance (MR) imaging and relaxation time measurements of bioresorbable implants made of polylactic acid (PLA), as well as the surrounding tissues, were carried out over a period of 6 months to monitor the implant state and the body's responses, and to determine how these processes are reflected in MR data. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199907)42:1<210::aid-mrm29

    authors: Stroman PW,Dorvil JC,Marois Y,Poddevin N,Guidoin R

    更新日期:1999-07-01 00:00:00

  • Dextran-magnetite: a contrast agent for sodium-23 MRI.

    abstract::Dextran-magnetite, a superparamagnetic compound, is a powerful relaxation reagent for sodium. Administered intravenously, it is confined mainly to the vasculature and eliminates the signal from plasma sodium, a significant component of the tissue sodium signal. Applications of dextran-magnetite for in vivo sodium imag...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910080406

    authors: Summers RM,Joseph PM,Renshaw PF,Kundel HL

    更新日期:1988-12-01 00:00:00

  • Steady state of echo-shifted sequences with radiofrequency phase cycling.

    abstract::Due to a delayed echo-formation, echo-shifted gradient echo sequences (ES-GRE) allow for an enhanced T(2)*-weighting at short repetition times. While they are in use with and without RF spoiling, analytical solutions are only known for the latter. The signal formation in the former could only be assessed in approximat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21010

    authors: Ganter C

    更新日期:2006-10-01 00:00:00

  • Model of the human vasculature for studying the influence of contrast injection speed on cerebral perfusion MRI.

    abstract::Simulations of dynamic susceptibility contrast (DSC) MRI are frequently performed by assuming a certain shape for the input function and the microvascular response function. However, to investigate the influence of parameters that will affect the shape of the input function, a more complex model of the human vasculatu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10567

    authors: van Osch MJ,Vonken EJ,Wu O,Viergever MA,van der Grond J,Bakker CJ

    更新日期:2003-09-01 00:00:00

  • Total brain N-acetylaspartate concentration in normal, age-grouped females: quantitation with non-echo proton NMR spectroscopy.

    abstract::The intra-individual and inter-individual variations of the global N-acetylaspartate (NAA) concentration were measured in a cohort of five 42+/-5 year-old normal females. The total NAA signal from the whole head was obtained with non-localized non-echo proton spectroscopy (1H-MRS) and converted into absolute mole amou...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.1910400506

    authors: Gonen O,Viswanathan AK,Catalaa I,Babb J,Udupa J,Grossman RI

    更新日期:1998-11-01 00:00:00

  • Detection of subnanotesla oscillatory magnetic fields using MRI.

    abstract:PURPOSE:Direct mapping of neuronal currents using MRI would have fundamental impacts on brain functional imaging. Previous reports indicated that the stimulus-induced rotary saturation (SIRS) mechanism had the best potential of direct detection of neural oscillations; however, it lacked the high-sensitivity level neede...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25553

    authors: Jiang X,Sheng J,Li H,Chai Y,Zhou X,Wu B,Guo X,Gao JH

    更新日期:2016-02-01 00:00:00

  • Partial field-of-view spiral phase-contrast imaging using complex difference processing.

    abstract::Rapid flow imaging was achieved with a partial field of view (pFOV) spiral motion-encoded technique. The FOV and the acquisition time were reduced by a factor of 2 by undersampling k-space. The pFOV spiral k-space trajectory aliased signals from outside a circular ring whose radius was inversely proportional to the di...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20975

    authors: Nezafat R,Thompson RB,Derbyshire JA,McVeigh ER

    更新日期:2006-09-01 00:00:00

  • Extended graphical model for analysis of dynamic contrast-enhanced MRI.

    abstract::Kinetic analysis with mathematical models has become increasingly important to quantify physiological parameters in computed tomography (CT), positron emission tomography (PET), and dynamic contrast-enhanced MRI (DCE-MRI). The modified Kety/Tofts model and the graphical (Patlak) model have been widely applied to DCE-M...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22819

    authors: Chen H,Li F,Zhao X,Yuan C,Rutt B,Kerwin WS

    更新日期:2011-09-01 00:00:00

  • Quantitative 1 H MRI and MRS of fatty acid composition.

    abstract::Adipose tissue as well as other depots of fat (triglycerides) are increasingly being recognized as active contributors to the human function and metabolism. In addition to the fat concentration, also the fatty acid chemical composition (FAC) of the triglyceride molecules may play an important part in diseases such as ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.28471

    authors: Peterson P,Trinh L,Månsson S

    更新日期:2021-01-01 00:00:00

  • Sensitive enhancement of vessel wall imaging with an endoesophageal Wireless Amplified NMR Detector (WAND).

    abstract:PURPOSE:To improve the imaging quality of vessel walls with an endoesophageal Wireless Amplified NMR Detector (WAND). METHODS:A cylindrically shaped double-frequency resonator has been constructed with a single metal wire that is self-connected by a pair of nonlinear capacitors. The double-frequency resonator can conv...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26562

    authors: Zeng X,Barbic M,Chen L,Qian C

    更新日期:2017-11-01 00:00:00

  • Fast design of local N-gram-specific absorption rate-optimized radiofrequency pulses for parallel transmit systems.

    abstract::Designing multidimensional radiofrequency pulses for clinical application must take into account the local specific absorption rate (SAR) as controlling the global SAR does not guarantee suppression of hot spots. The maximum peak SAR, averaged over an N grams cube (local NgSAR), must be kept under certain safety limit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23049

    authors: Sbrizzi A,Hoogduin H,Lagendijk JJ,Luijten P,Sleijpen GL,van den Berg CA

    更新日期:2012-03-01 00:00:00

  • Repeatability and variability of myocardial perfusion imaging techniques in mice: Comparison of arterial spin labeling and first-pass contrast-enhanced MRI.

    abstract:PURPOSE:Preclinical imaging of myocardial blood flow (MBF) can elucidate molecular mechanisms underlying cardiovascular disease. We compared the repeatability and variability of two methods, first-pass MRI and arterial spin labeling (ASL), for imaging MBF in mice. METHODS:Quantitative perfusion MRI in mice was perform...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25769

    authors: Naresh NK,Chen X,Moran E,Tian Y,French BA,Epstein FH

    更新日期:2016-06-01 00:00:00

  • Variable density incoherent spatiotemporal acquisition (VISTA) for highly accelerated cardiac MRI.

    abstract:PURPOSE:For the application of compressive sensing to parallel MRI, Poisson disk sampling (PDS) has been shown to generate superior results compared with random sampling methods. However, due to its limited flexibility to incorporate additional constraints, PDS is not readily extendible to dynamic applications. Here, w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25507

    authors: Ahmad R,Xue H,Giri S,Ding Y,Craft J,Simonetti OP

    更新日期:2015-11-01 00:00:00

  • Assessment and correction of macroscopic field variations in 2D spoiled gradient-echo sequences.

    abstract:PURPOSE:To model and correct the dephasing effects in the gradient-echo signal for arbitrary RF excitation pulses with large flip angles in the presence of macroscopic field variations. METHODS:The dephasing of the spoiled 2D gradient-echo signal was modeled using a numerical solution of the Bloch equations to calcula...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28139

    authors: Soellradl M,Lesch A,Strasser J,Pirpamer L,Stollberger R,Ropele S,Langkammer C

    更新日期:2020-08-01 00:00:00

  • Simultaneous measurement of intracellular and extracellular oxygen concentrations using a nitroxide-liposome system.

    abstract::The concentration of oxygen within cells is important in many physiological and pathological processes, but such oxygen-dependent phenomena are generally studied as a function of the concentration of extracellular oxygen, due to a lack of suitable methods. Electron parmamagnetic resonance (EPR) oximetric techniques of...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290105

    authors: Glockner JF,Norby SW,Swartz HM

    更新日期:1993-01-01 00:00:00

  • Improved sampling of myocardial motion with variable separation tagging.

    abstract::A novel tagging method is introduced that increases the spatial resolution of estimates of myocardial radial thickening. The separation of adjacent parallel tag planes is customized to match the expected motion of specific regions of the heart wall. In regions in which the tags increase their separation over systole (...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390421

    authors: McVeigh ER,Bolster BD Jr

    更新日期:1998-04-01 00:00:00