Accelerated MR parameter mapping with low-rank and sparsity constraints.

Abstract:

PURPOSE:To enable accurate magnetic resonance (MR) parameter mapping with accelerated data acquisition, utilizing recent advances in constrained imaging with sparse sampling. THEORY AND METHODS:A new constrained reconstruction method based on low-rank and sparsity constraints is proposed to accelerate MR parameter mapping. More specifically, the proposed method simultaneously imposes low-rank and joint sparse structures on contrast-weighted image sequences within a unified mathematical formulation. With a pre-estimated subspace, this formulation results in a convex optimization problem, which is solved using an efficient numerical algorithm based on the alternating direction method of multipliers. RESULTS:To evaluate the performance of the proposed method, two application examples were considered: (i) T2 mapping of the human brain and (ii) T1 mapping of the rat brain. For each application, the proposed method was evaluated at both moderate and high acceleration levels. Additionally, the proposed method was compared with two state-of-the-art methods that only use a single low-rank or joint sparsity constraint. The results demonstrate that the proposed method can achieve accurate parameter estimation with both moderately and highly undersampled data. Although all methods performed fairly well with moderately undersampled data, the proposed method achieved much better performance (e.g., more accurate parameter values) than the other two methods with highly undersampled data. CONCLUSIONS:Simultaneously imposing low-rank and sparsity constraints can effectively improve the accuracy of fast MR parameter mapping with sparse sampling.

journal_name

Magn Reson Med

authors

Zhao B,Lu W,Hitchens TK,Lam F,Ho C,Liang ZP

doi

10.1002/mrm.25421

subject

Has Abstract

pub_date

2015-08-01 00:00:00

pages

489-98

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

74

pub_type

杂志文章
  • Phase-sensitive inversion recovery for myocardial T1 mapping with motion correction and parametric fitting.

    abstract::The assessment of myocardial fibrosis and extracellular volume requires accurate estimation of myocardial T1 s. While image acquisition using the modified Look-Locker inversion recovery technique is clinically feasible for myocardial T1 mapping, respiratory motion can limit its applicability. Moreover, the conventiona...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24385

    authors: Xue H,Greiser A,Zuehlsdorff S,Jolly MP,Guehring J,Arai AE,Kellman P

    更新日期:2013-05-01 00:00:00

  • The uncommon longitudinal relaxation dispersion of human brain white matter.

    abstract::Human brain white matter exhibits an uncommonly strong dispersion of 1/T1 at high fields. An additional relaxation pathway via the myelin lipids, which are not directly visible to medical NMR due to their fast T2 decay, is proposed. Relaxation dispersion data are successfully analyzed on the basis of this model. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910090319

    authors: Fischer HW,Van Haverbeke Y,Schmitz-Feuerhake I,Muller RN

    更新日期:1989-03-01 00:00:00

  • A flexible 32-channel receive array combined with a homogeneous transmit coil for human lung imaging with hyperpolarized 3He at 1.5 T.

    abstract::Parallel imaging presents a promising approach for MRI of hyperpolarized nuclei, as the penalty in signal-to-noise ratio typically encountered with (1)H MRI due to a reduction in acquisition time can be offset by an increase in flip angle. The signal-to-noise ratio of hyperpolarized MRI generally exhibits a strong dep...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22962

    authors: Deppe MH,Parra-Robles J,Marshall H,Lanz T,Wild JM

    更新日期:2011-12-01 00:00:00

  • Infimal convolution of total generalized variation functionals for dynamic MRI.

    abstract:PURPOSE:To accelerate dynamic MR applications using infimal convolution of total generalized variation functionals (ICTGV) as spatio-temporal regularization for image reconstruction. THEORY AND METHODS:ICTGV comprises a new image prior tailored to dynamic data that achieves regularization via optimal local balancing b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26352

    authors: Schloegl M,Holler M,Schwarzl A,Bredies K,Stollberger R

    更新日期:2017-07-01 00:00:00

  • Differentiation between cortical atrophy and hydrocephalus using 1H MRS.

    abstract::Quantitative 1H MRS to determine cerebral metabolite patterns and MRI to determine CSF flow were applied to 12 patients with ventricular dilation-Group A, cortical atrophy (N = 5); or Group B, hydrocephalus (N = 7)- and in 9 normal controls. While mean brain water (Group A = 80% +/- 6; Group B = 86% +/- 5; normal = 85...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370317

    authors: Bluml S,McComb JG,Ross BD

    更新日期:1997-03-01 00:00:00

  • Arrays of mutually coupled receiver coils: theory and application.

    abstract::Specialized receiver coils having a small sensitive region can provide an improvement in SNR for MR imaging and spectroscopy, at the expense of limiting the usable field of view. This work presents a technique for designing coil arrays that allows the size and location of the sensitive region to be selected remotely. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170128

    authors: Wright SM,Magin RL,Kelton JR

    更新日期:1991-01-01 00:00:00

  • Partial Fourier techniques in single-shot cross-term spatiotemporal encoded MRI.

    abstract:PURPOSE:Cross-term spatiotemporal encoding (xSPEN) is a single-shot approach with exceptional immunity to field heterogeneities, the images of which faithfully deliver 2D spatial distributions without requiring a priori information or using postacquisition corrections. xSPEN, however, suffers from signal-to-noise ratio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26824

    authors: Zhang Z,Frydman L

    更新日期:2018-03-01 00:00:00

  • Reduction of resonant RF heating in intravascular catheters using coaxial chokes.

    abstract::The incorporation of RF coils into the tips of intravascular devices has been shown to enable the localization of catheters and guidewires under MR guidance. Furthermore, such coils can be used for endoluminal imaging. The long cable required to connect the coil with the scanner input inadvertently acts as a dipole an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200004)43:4<615::aid-mrm19

    authors: Ladd ME,Quick HH

    更新日期:2000-04-01 00:00:00

  • T2 relaxation-time mapping in healthy and diseased skeletal muscle using extended phase graph algorithms.

    abstract:PURPOSE:Multi-echo spin-echo (MSE) transverse relaxometry mapping using multi-component models is used to study disease activity in neuromuscular disease by assessing the T2 of the myocytic component (T2water ). Current extended phase graph algorithms are not optimized for fat fractions above 50% and the effects of ina...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28290

    authors: Keene KR,Beenakker JM,Hooijmans MT,Naarding KJ,Niks EH,Otto LAM,van der Pol WL,Tannemaat MR,Kan HE,Froeling M

    更新日期:2020-11-01 00:00:00

  • Dynamic contrast enhanced MRI parameters and tumor cellularity in a rat model of cerebral glioma at 7 T.

    abstract:PURPOSE:To test the hypothesis that a noninvasive dynamic contrast enhanced MRI (DCE-MRI) derived interstitial volume fraction (ve ) and/or distribution volume (VD ) were correlated with tumor cellularity in cerebral tumor. METHODS:T1 -weighted DCE-MRI studies were performed in 18 athymic rats implanted with U251 xeno...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24873

    authors: Aryal MP,Nagaraja TN,Keenan KA,Bagher-Ebadian H,Panda S,Brown SL,Cabral G,Fenstermacher JD,Ewing JR

    更新日期:2014-06-01 00:00:00

  • Longitudinal assessment of spinal cord injuries in nonhuman primates with quantitative magnetization transfer.

    abstract:PURPOSE:This study aimed to evaluate the reproducibility and specificity of quantitative magnetization transfer (qMT) imaging for monitoring spinal cord injuries (SCIs). METHODS:MRI scans were performed in anesthetized monkeys at 9.4T, before and serially after a unilateral lesion of the cervical spinal cord. A two-po...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25725

    authors: Wang F,Li K,Mishra A,Gochberg D,Min Chen L,Gore JC

    更新日期:2016-04-01 00:00:00

  • Spin echo measurements of the extravasation and tumor cell uptake of hyperpolarized [1-(13) C]lactate and [1-(13) C]pyruvate.

    abstract:PURPOSE:To assess the blood-tissue distribution of hyperpolarized (13) C-labeled molecules in vivo. METHODS:Spin-echo experiments with simultaneous acquisition of the free induction decay (FID) signal following the excitation pulse and the spin-echo signal, were used to monitor hyperpolarized [1-(13) C]lactate, [1-(13...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24591

    authors: Kettunen MI,Kennedy BW,Hu DE,Brindle KM

    更新日期:2013-11-01 00:00:00

  • Inductively coupled Helmholtz coil on a dedicated imaging platform for the in vivo 1H-MRS measurement of intramyocellular lipids in the hind leg of rats.

    abstract::Skeletal muscle triglycerides are markers for insulin resistance in type 2 diabetes. Recently, MR spectroscopy was adapted for in vivo measurement of triglycerides in animal models and for the characterization of new therapeutic approaches. Because of small MR spectroscopy voxel sizes used in skeletal muscles, surface...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22149

    authors: Neumaier M,Niessen HG,Kaulisch T,Stiller D

    更新日期:2009-10-01 00:00:00

  • Mean magnetic susceptibility regularized susceptibility tensor imaging (MMSR-STI) for estimating orientations of white matter fibers in human brain.

    abstract:PURPOSE:An increasing number of studies show that magnetic susceptibility in white matter fibers is anisotropic and may be described by a tensor. However, the limited head rotation possible for in vivo human studies leads to an ill-conditioned inverse problem in susceptibility tensor imaging (STI). Here we suggest the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25322

    authors: Li X,van Zijl PC

    更新日期:2014-09-01 00:00:00

  • Sources of functional apparent diffusion coefficient changes investigated by diffusion-weighted spin-echo fMRI.

    abstract::The mechanism behind previously observed changes in the apparent diffusion coefficient (ADC) during brain activation is not well understood. Therefore, we investigated the signal source and spatial specificity of functional magnetic resonance imaging (fMRI) ADC changes systematically in the visual cortex of cats using...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21074

    authors: Jin T,Zhao F,Kim SG

    更新日期:2006-12-01 00:00:00

  • Application of phase rotation to STRESS localization scheme at 3 T.

    abstract:PURPOSE:Application of phase rotation to the STRESS (=STEAM+PRESS) localization scheme, to shorten echo time, minimize J-coupling dephasing and estimate B1+ inhomogeneity. STRESS (=STEAM + PRESS) simultaneously refocuses and acquires the double spin echo (SE123 ) and stimulated echo (STE- ) pathways, combining PRESS-li...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26911

    authors: Volovyk O,Tal A

    更新日期:2018-05-01 00:00:00

  • Evolution of the longitudinal magnetization for pulse sequences using a fast spin-echo readout: application to fluid-attenuated inversion-recovery and double inversion-recovery sequences.

    abstract::The fast spin-echo (FSE) sequence is frequently used as a fast data-readout technique in conjunction with other pulse sequence elements, such as in fluid-attenuated inversion-recovery (FLAIR) and double inversion-recovery (DIR) sequences. In order to implement those pulse sequences, an understanding is required of how...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20541

    authors: Meara SJ,Barker GJ

    更新日期:2005-07-01 00:00:00

  • Application of DENSE-MR-elastography to the human heart.

    abstract::Typically, MR-elastography (MRE) encodes the propagation of monochromatic acoustic waves in the MR-phase images via sinusoidal gradients characterized by a detection frequency equal to the frequency of the mechanical vibration. Therefore, the echo time of a conventional MRE sequence is typically longer than the vibrat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22124

    authors: Robert B,Sinkus R,Gennisson JL,Fink M

    更新日期:2009-11-01 00:00:00

  • Sensitivity enhancement and reduction of Gibbs artifact in T2-weighted imaging using variable tip angle excitation.

    abstract::Introduction of a Gaussian weighting function into the phase encoding of the spin-echo imaging method via variable tip angle excitation, with concomitant optimization of the recycle delay, is shown to increase the sensitivity of T2-weighted imaging by up to 40%. In addition, the Gibbs artifact associated with sharp bo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910210216

    authors: Webb AG,Clarkson RB

    更新日期:1991-10-01 00:00:00

  • Coronary MR angiography using image-based respiratory motion compensation with inline correction and fixed gating efficiency.

    abstract:PURPOSE:The purpose of this study was to evaluate a new inline motion compensation approach called image-based navigation with Constant Respiratory efficiency UsIng Single End-expiratory threshold (iNAV-CRUISE) for coronary MR angiography (CMRA). METHODS:The CRUISE gating technique was combined with iNAV motion correc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26678

    authors: Henningsson M,Smink J,van Ensbergen G,Botnar R

    更新日期:2018-01-01 00:00:00

  • Implementation of vascular-space-occupancy MRI at 7T.

    abstract::Vascular-space-occupancy (VASO) MRI exploits the difference between blood and tissue T1 to null blood signal and measure cerebral blood volume changes using the residual tissue signal. VASO imaging is more difficult at higher field because of sensitivity loss due to the convergence of tissue and blood T1 values and in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24334

    authors: Hua J,Jones CK,Qin Q,van Zijl PC

    更新日期:2013-04-01 00:00:00

  • Fast model-based T2 mapping using SAR-reduced simultaneous multislice excitation.

    abstract:PURPOSE:To obtain whole-brain high-resolution T2 maps in 2 minutes by combining simultaneous multislice excitation and low-power PINS (power independent of number of slices) refocusing pulses with undersampling and a model-based reconstruction. METHODS:A multi-echo spin-echo sequence was modified to acquire multiple s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27890

    authors: Hilbert T,Schulz J,Marques JP,Thiran JP,Krueger G,Norris DG,Kober T

    更新日期:2019-12-01 00:00:00

  • Measurement of cerebrospinal fluid oxygen partial pressure in humans using MRI.

    abstract::Fluid-attenuated inversion recovery (FLAIR) images obtained during the administration of supplemental oxygen demonstrate a hyperintense signal within the cerebrospinal fluid (CSF) that is likely caused by T1 changes induced by paramagnetic molecular oxygen. Previous studies demonstrated a linear relationship between t...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20546

    authors: Zaharchuk G,Martin AJ,Rosenthal G,Manley GT,Dillon WP

    更新日期:2005-07-01 00:00:00

  • Ultrahigh-resolution quantitative spinal cord MRI at 9.4T.

    abstract:PURPOSE:To present the results of the first human spinal cord in vivo MRI scans at 9.4T. METHODS:A human brain coil was used to image the human spinal cord at 9.4T. All anatomical images were acquired with a T2 *-weighted gradient-echo sequence. A comparison of the influence of four different B0 shimming routines on t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28455

    authors: Geldschläger O,Bosch D,Avdievich NI,Henning A

    更新日期:2021-02-01 00:00:00

  • Cardiac and respiratory double self-gated cine MRI in the mouse at 7 T.

    abstract::ECG-gated cardiac MRI in the mouse is hindered by many technical difficulties in ECG signal recording inside static and variable high magnetic scanner fields. The present study proposes an alternative robust method of acquiring auto-gated cardiac and respiratory cine images in mouse heart. In our approach, a motion sy...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20815

    authors: Hiba B,Richard N,Janier M,Croisille P

    更新日期:2006-03-01 00:00:00

  • Understanding and optimizing the amplitude modulated control for multiple-slice continuous arterial spin labeling.

    abstract::Multiple-slice perfusion imaging by continuous arterial spin labeling (CASL) is made possible by amplitude modulation (AM) of the labeling RF pulse, but perfusion sensitivity is reduced relative to the single-slice technique. A computer model of the Bloch equations for velocity driven adiabatic fast passage was develo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20604

    authors: Utting JF,Thomas DL,Gadian DG,Helliar RW,Lythgoe MF,Ordidge RJ

    更新日期:2005-09-01 00:00:00

  • Porous medium 3D flow simulation of contrast media washout in cardiac MRI reflects myocardial injury.

    abstract:PURPOSE:Myocardial blood-flow simulation based on laws of fluid mechanics is a valuable tool for understanding tissue behavior. Our aim is to evaluate the ability of a porous-media flow model approach to reflect disturbed washout of contrast media (CM) from the myocardium as observed by cardiovascular MR. METHODS:A co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27756

    authors: Riazy L,Schaeffter T,Olbrich M,Schueler J,von Knobelsdorff-Brenkenhoff F,Niendorf T,Schulz-Menger J

    更新日期:2019-08-01 00:00:00

  • Intravoxel distribution of DWI decay rates reveals C6 glioma invasion in rat brain.

    abstract::The hypothesis was tested that the intravoxel distribution of water diffusion rates, as measured with a stretched-exponential model of diffusion-weighted imaging (DWI), is a marker of brain tumor invasion. Eight rats underwent intracerebral inoculation of C6 glioma cells. In three rats, cells were labeled with a fluor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20286

    authors: Bennett KM,Hyde JS,Rand SD,Bennett R,Krouwer HG,Rebro KJ,Schmainda KM

    更新日期:2004-11-01 00:00:00

  • Myocardial fat quantification in humans: Evaluation by two-point water-fat imaging and localized proton spectroscopy.

    abstract::Proton MR spectroscopy ((1)H-MRS) has been used for in vivo quantification of intracellular triglycerides within the sarcolemma. The purpose of this study was to assess whether breath-hold dual-echo in- and out-of-phase MRI at 3.0 T can quantify the fat content of the myocardium. Biases, including T(1), T*(2), and noi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22289

    authors: Liu CY,Redheuil A,Ouwerkerk R,Lima JA,Bluemke DA

    更新日期:2010-04-01 00:00:00

  • Observing curved flow using RUFIS.

    abstract::The rotating ultra-fast imaging sequence (RUFIS) is used to image spins flowing through the curved portion of a 180 degrees U-tube with a circular cross section and a ratio of inner diameter to curvature diameter of 0.41. A velocity-encoding preparation sequence is used with RUFIS to measure quantitatively the axial v...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199906)41:6<1258::aid-mrm2

    authors: Gach HM,Lowe IJ

    更新日期:1999-06-01 00:00:00