Intracellular redox state revealed by in vivo (31) P MRS measurement of NAD(+) and NADH contents in brains.

Abstract:

PURPOSE:Nicotinamide adenine dinucleotide (NAD), in oxidized (NAD(+) ) or reduced (NADH) form, plays key roles in cellular metabolism. Intracellular NAD(+) /NADH ratio represents the cellular redox state; however, it is difficult to measure in vivo. We report here a novel in vivo (31) P MRS method for noninvasive measurement of intracellular NAD concentrations and NAD(+) /NADH ratio in the brain. METHODS:It uses a theoretical model to describe the NAD spectral patterns at a given field for quantification. Standard NAD solutions and independent cat brain measurements at 9.4 T and 16.4 T were used to evaluate this method. We also measured T1 values of brain NAD. RESULTS:Model simulation and studies of solutions and brains indicate that the proposed method can quantify submillimolar NAD concentrations with reasonable accuracy if adequate (31) P MRS signal-to-noise ratio and linewidth were obtained. The NAD concentrations and NAD(+) /NADH ratio of cat brains measured at 16.4 T and 9.4 T were consistent despite the significantly different T1 values and NAD spectra patterns at two fields. CONCLUSION:This newly established (31) P MRS method makes it possible for the first time to noninvasively study the intracellular redox state and its roles in brain functions and diseases, and it can potentially be applied to other organs.

journal_name

Magn Reson Med

authors

Lu M,Zhu XH,Zhang Y,Chen W

doi

10.1002/mrm.24859

subject

Has Abstract

pub_date

2014-06-01 00:00:00

pages

1959-72

issue

6

eissn

0740-3194

issn

1522-2594

journal_volume

71

pub_type

杂志文章
  • Intravoxel incoherent motion imaging using steady-state free precession.

    abstract::IVIM MR imaging is a method which generates images of diffusion and perfusion in vivo. Until now, intravoxel incoherent motion (IVIM) images have been obtained using spin-echo sequences with extragradient pulses, resulting in long acquisition times (typically 2 x 8 min 32 s). A new method is proposed here, using stead...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910070312

    authors: Le Bihan D

    更新日期:1988-07-01 00:00:00

  • Efficient biphasic spin-echo magnetic resonance imaging.

    abstract::The concept of temporal echo multiplexing is defined and used to develop rapid biphasic spin-echo sequences for imaging the heart. Three imaging sequences, based on four-echo and two-echo multiplexing and rapid single echo (i.e., conventional spin-echo imaging), are compared. Preliminary results indicate that two-echo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910110109

    authors: Parker DL,Caputo GR,Frederick PR

    更新日期:1989-07-01 00:00:00

  • Relaxometry of brain: why white matter appears bright in MRI.

    abstract::The remarkable success of magnetic resonance imaging of adult brain relates to the unusually large ratio of the longitudinal relaxation rates 1/T1 of white and gray matter, approximately 2:1 at physiological temperature and traditional imaging fields. Several investigators have conjectured that myelin is the source of...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910140306

    authors: Koenig SH,Brown RD 3rd,Spiller M,Lundbom N

    更新日期:1990-06-01 00:00:00

  • Factors influencing the accuracy and precision of velocity-encoded phase imaging.

    abstract::Velocity-encoded phase contrast imaging is being used increasingly in clinical imaging for quantization of blood flow. In this study, the accuracy and precision of ascending aorta flow measurements were found to depend on several subtle aspects of the scan prescription and image analysis. While the usual scan paramete...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910260115

    authors: Buonocore MH,Bogren H

    更新日期:1992-07-01 00:00:00

  • Improved large tip angle parallel transmission pulse design through a perturbation analysis of the Bloch equation.

    abstract::Parallel transmission has emerged as an efficient means for implementing multidimensional spatially selective radiofrequency excitation pulses. To date, most theoretical and experimental work on parallel transmission radiofrequency (RF) pulse design is based on the small-tip-angle approximation to the Bloch equation. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22827

    authors: Zheng H,Zhao T,Qian Y,Ibrahim TS,Boada FE

    更新日期:2011-09-01 00:00:00

  • Assessment of quantitative artificial neural network analysis in a metabolically dynamic ex vivo 31P NMR pig liver study.

    abstract::Quantitative artificial neural network analysis for 1550 ex vivo 31P nuclear magnetic resonance spectra from hypothermically reperfused pig livers was assessed. These spectra show wide ranges of metabolite concentrations and have been analyzed using metabolite prior knowledge based lineshape fitting analysis which had...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380522

    authors: Ala-Korpela M,Changani KK,Hiltunen Y,Bell JD,Fuller BJ,Bryant DJ,Taylor-Robinson SD,Davidson BR

    更新日期:1997-11-01 00:00:00

  • Diffusion tensor imaging using single-shot SENSE-EPI.

    abstract::SENSitivity Encoding (SENSE) greatly enhances the quality of diffusion-weighted echo-planar imaging (EPI) by reducing blurring and off-resonance artifacts. Such improvement would also be desirable for diffusion tensor imaging (DTI), but measures derived from the diffusion tensor can be extremely sensitive to any kind ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10184

    authors: Bammer R,Auer M,Keeling SL,Augustin M,Stables LA,Prokesch RW,Stollberger R,Moseley ME,Fazekas F

    更新日期:2002-07-01 00:00:00

  • Wavelet-space correlation imaging for high-speed MRI without motion monitoring or data segmentation.

    abstract:PURPOSE:This study aims to (i) develop a new high-speed MRI approach by implementing correlation imaging in wavelet-space, and (ii) demonstrate the ability of wavelet-space correlation imaging to image human anatomy with involuntary or physiological motion. METHODS:Correlation imaging is a high-speed MRI framework in ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25546

    authors: Li Y,Wang H,Tkach J,Roach D,Woods J,Dumoulin C

    更新日期:2015-12-01 00:00:00

  • Mean magnetic susceptibility regularized susceptibility tensor imaging (MMSR-STI) for estimating orientations of white matter fibers in human brain.

    abstract:PURPOSE:An increasing number of studies show that magnetic susceptibility in white matter fibers is anisotropic and may be described by a tensor. However, the limited head rotation possible for in vivo human studies leads to an ill-conditioned inverse problem in susceptibility tensor imaging (STI). Here we suggest the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25322

    authors: Li X,van Zijl PC

    更新日期:2014-09-01 00:00:00

  • 16-channel bow tie antenna transceiver array for cardiac MR at 7.0 tesla.

    abstract:PURPOSE:To design, evaluate, and apply a bow tie antenna transceiver radiofrequency (RF) coil array tailored for cardiac MRI at 7.0 Tesla (T). METHODS:The radiofrequency (RF) coil array comprises 16 building blocks each containing a bow tie shaped λ/2-dipole antenna. Numerical simulations were used for transmission fi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25840

    authors: Oezerdem C,Winter L,Graessl A,Paul K,Els A,Weinberger O,Rieger J,Kuehne A,Dieringer M,Hezel F,Voit D,Frahm J,Niendorf T

    更新日期:2016-06-01 00:00:00

  • Ultrashort echo time spectroscopic imaging (UTESI) of cortical bone.

    abstract::Cortical bone in the mature skeleton has a short T(2)* and produces no detectable signal with conventional MR sequences. A two-dimensional ultrashort echo time (UTE) sequence employing half radio frequency (RF) pulse excitations and radial ramp sampling reduces the effective TE to 8 micros and is capable of detecting ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21397

    authors: Du J,Hamilton G,Takahashi A,Bydder M,Chung CB

    更新日期:2007-11-01 00:00:00

  • Detection and volume determination of colonic tumors in Min mice by magnetic resonance micro-imaging.

    abstract::We applied MRI to the in vivo detection of spontaneous colorectal tumors in a unique mouse model, the Fox Chase Cancer Center (FCCC) ApcMIN mouse. Unlike other Min (multiple intestinal neoplasia) strains, FCCC ApcMIN animals develop an appreciable number of tumors in the large intestine, which makes them an appropriat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20175

    authors: Hensley HH,Chang WC,Clapper ML

    更新日期:2004-09-01 00:00:00

  • Three-dimensional water/fat separation and T2* estimation based on whole-image optimization--application in breathhold liver imaging at 1.5 T.

    abstract::The chemical shift of water and fat resonances in proton MRI allows separation of water and fat signal from chemical shift encoded data. This work describes an automatic method that produces separate water and fat images as well as quantitative maps of fat signal fraction and T2* from complex multiecho gradient-recall...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23185

    authors: Berglund J,Kullberg J

    更新日期:2012-06-01 00:00:00

  • Measurement of cerebrospinal fluid oxygen partial pressure in humans using MRI.

    abstract::Fluid-attenuated inversion recovery (FLAIR) images obtained during the administration of supplemental oxygen demonstrate a hyperintense signal within the cerebrospinal fluid (CSF) that is likely caused by T1 changes induced by paramagnetic molecular oxygen. Previous studies demonstrated a linear relationship between t...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.20546

    authors: Zaharchuk G,Martin AJ,Rosenthal G,Manley GT,Dillon WP

    更新日期:2005-07-01 00:00:00

  • Effects of imaging gradients in sequences with varying longitudinal storage time-Case of diffusion exchange imaging.

    abstract:PURPOSE:To illustrate the potential bias caused by imaging gradients in correlation MRI sequences using longitudinal magnetization storage (LS) and examine the case of filter exchange imaging (FEXI) yielding maps of the apparent exchange rate (AXR). METHODS:The effects of imaging gradients in FEXI were observed on yea...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26856

    authors: Lasič S,Lundell H,Topgaard D,Dyrby TB

    更新日期:2018-04-01 00:00:00

  • Quantitative susceptibility mapping detects abnormalities in cartilage canals in a goat model of preclinical osteochondritis dissecans.

    abstract:PURPOSE:To use quantitative susceptibility mapping (QSM) to investigate changes in cartilage canals in the distal femur of juvenile goats after their surgical transection. METHODS:Chondronecrosis was surgically induced in the right medial femoral condyles of four 4-day-old goats. Both the operated and control knees we...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26214

    authors: Wang L,Nissi MJ,Toth F,Johnson CP,Garwood M,Carlson CS,Ellermann J

    更新日期:2017-03-01 00:00:00

  • Sliding time of flight: sliding time of flight MR angiography using a dynamic image reconstruction method.

    abstract:PURPOSE:To obtain three-dimensional (3D) MR angiography having high contrast between vessel and stationary background tissue, a novel technique called sliding time of flight (TOF) is proposed. METHODS:The proposed method relies on the property that flow-related enhancement (FRE) is maximized at the blood-entering slic...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25215

    authors: Choi J,Seo H,Lim Y,Han Y,Park H

    更新日期:2015-03-01 00:00:00

  • System identification theory in pharmacokinetic modeling of dynamic contrast-enhanced MRI: influence of contrast injection.

    abstract::Optimization of experimental settings of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), like the contrast administration protocol, is of great importance for reliable quantification of the microcirculatory properties, such as the volume transfer-constant K(trans). Using system identification theory an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21575

    authors: Aerts HJ,van Riel NA,Backes WH

    更新日期:2008-05-01 00:00:00

  • Simultaneous multislice multiband parallel radiofrequency excitation with independent slice-specific transmit B1 homogenization.

    abstract:PURPOSE:To develop a new parallel transmit (pTx) pulse design for simultaneous multiband (MB) excitation in order to tackle simultaneously the problems of transmit B1 (B1+) inhomogeneity and total radiofrequency (RF) power, so as to allow for optimal RF excitation when using MB pulses for slice acceleration for high an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24828

    authors: Wu X,Schmitter S,Auerbach EJ,Moeller S,Uğurbil K,Van de Moortele PF

    更新日期:2013-09-01 00:00:00

  • Simultaneous spin-echo refocusing.

    abstract::A new approach to spin-echo imaging is presented in which the 180 degrees RF pulse refocuses two or more spin-echoes at different positions in the readout period. When simultaneous echo refocusing (SER) is implemented using multiple 180 degrees pulses, an undesirable mixing of stimulated echoes and primary echoes from...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20587

    authors: Günther M,Feinberg DA

    更新日期:2005-09-01 00:00:00

  • Diffusion dispersion imaging: Mapping oscillating gradient spin-echo frequency dependence in the human brain.

    abstract:PURPOSE:Oscillating gradient spin-echo (OGSE) diffusion MRI provides information about the microstructure of biological tissues by means of the frequency dependence of the apparent diffusion coefficient (ADC). ADC dependence on OGSE frequency has been explored in numerous rodent studies, but applications in the human b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28083

    authors: Arbabi A,Kai J,Khan AR,Baron CA

    更新日期:2020-06-01 00:00:00

  • Real-time cardiovascular MR with spatio-temporal artifact suppression using deep learning-proof of concept in congenital heart disease.

    abstract:PURPOSE:Real-time assessment of ventricular volumes requires high acceleration factors. Residual convolutional neural networks (CNN) have shown potential for removing artifacts caused by data undersampling. In this study, we investigated the ability of CNNs to reconstruct highly accelerated radial real-time data in pat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27480

    authors: Hauptmann A,Arridge S,Lucka F,Muthurangu V,Steeden JA

    更新日期:2019-02-01 00:00:00

  • Development and validation of 3D MP-SSFP to enable MRI in inhomogeneous magnetic fields.

    abstract:PURPOSE:We demonstrate the feasibility of MRI with missing-pulse steady-state free precession (MP-SSFP) in a 4T magnet with artificially degraded homogeneity. METHODS:T1 , T2 , and diffusion contrast of MP-SSFP was simulated with constant and alternate radiofrequency (RF) phase using an extended phase graph. To valida...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28469

    authors: Kobayashi N,Parkinson B,Idiyatullin D,Adriany G,Theilenberg S,Juchem C,Garwood M

    更新日期:2021-02-01 00:00:00

  • Statistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise.

    abstract::This work helps elucidate how background noise introduces statistical artifacts in the distribution of the sorted eigenvalues and eigenvectors in diffusion tensor MRI (DT-MRI) data. Although it was known that sorting eigenvalues (principal diffusivities) by magnitude introduces a bias in their sample mean within a hom...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200007)44:1<41::aid-mrm8>3.0.co;

    authors: Basser PJ,Pajevic S

    更新日期:2000-07-01 00:00:00

  • Quantitative 1 H MRI and MRS of fatty acid composition.

    abstract::Adipose tissue as well as other depots of fat (triglycerides) are increasingly being recognized as active contributors to the human function and metabolism. In addition to the fat concentration, also the fatty acid chemical composition (FAC) of the triglyceride molecules may play an important part in diseases such as ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.28471

    authors: Peterson P,Trinh L,Månsson S

    更新日期:2021-01-01 00:00:00

  • Sensitivity of feedback-enhanced MRI contrast to macroscopic and microscopic field variations.

    abstract::Nonlinear feedback interactions have been shown to amplify contrast due to small differences in resonance frequency arising from microscopic susceptibility variations. Determining whether the selectivity of feedback-based contrast enhancement for small resonance frequency variations remains valid even in the presence ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21584

    authors: Huang SY,Yang SS,Lin YY

    更新日期:2009-04-01 00:00:00

  • Evidence for enhanced functional activity of cervical cord in relapsing multiple sclerosis.

    abstract::Functional MRI (fMRI) was used to assess proprioceptive-associated cervical cord activity in 24 relapsing multiple sclerosis (MS) patients and 10 controls. Cord and brain conventional and diffusion tensor (DT) MRI were also acquired. fMRI was performed using a block design during a proprioceptive stimulation consistin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21595

    authors: Agosta F,Valsasina P,Rocca MA,Caputo D,Sala S,Judica E,Stroman PW,Filippi M

    更新日期:2008-05-01 00:00:00

  • Interactive continuously moving table (iCMT) large field-of-view real-time MRI.

    abstract::Continuously moving table (CMT) MRI is a new method that is capable of generating 3D, seamless, large field-of-view (FOV) images by acquiring readouts along the patient superior-inferior axis as the subject is translated through the scanner. For applications that require artifact-free images, such as arterial-phase co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20848

    authors: Sabati M,Lauzon ML,Mahallati H,Frayne R

    更新日期:2006-05-01 00:00:00

  • Optimized 3D ultrashort echo time pulmonary MRI.

    abstract:PURPOSE:To optimize 3D radial ultrashort echo time MRI for high resolution whole-lung imaging. METHODS:3D radial ultrashort echo time was implemented on a 3T scanner to investigate the effects of: (1) limited field-of-view excitation, (2) variable density readouts, and (3) radial oversampling. Improvements in noise pe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24570

    authors: Johnson KM,Fain SB,Schiebler ML,Nagle S

    更新日期:2013-11-01 00:00:00

  • Dynamic 13C NMR analysis of pyruvate and lactate oxidation in the in vivo canine myocardium: evidence of reduced utilization with increased work.

    abstract::In this work, substrate selection was monitored in the left ventricle of the canine myocardium by following pyruvate and lactate oxidation under in vivo conditions at basal and elevated workloads. These studies were conducted in the open chest model using dynamic 13C NMR techniques in the presence and absence of dichl...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380608

    authors: Rath DP,Zhu H,Tong X,Jiang Z,Hamlin RL,Robitaille PM

    更新日期:1997-12-01 00:00:00