Identification of signal bias in the variable flip angle method by linear display of the algebraic Ernst equation.

Abstract:

:A novel linear parameterization for the variable flip angle method for longitudinal relaxation time T(1) quantification from spoiled steady state MRI is derived from the half angle tangent transform, τ, of the flip angle. Plotting the signal S at coordinates x=Sτ and y=S/τ, respectively, establishes a line that renders signal amplitude and relaxation term separately as y-intercept and slope. This representation allows for estimation of the respective parameter from the experimental data. A comprehensive analysis of noise propagation is performed. Numerical results for efficient optimization of longitudinal relaxation time and proton density mapping experiments are derived. Appropriate scaling allows for a linear presentation of data that are acquired at different short pulse repetition times, TR < T1 thus increasing flexibility in the data acquisition by removing the limitation of a single pulse repetition time. Signal bias, like due to slice-selective excitation or imperfect spoiling, can be readily identified by systematic deviations from the linear plot. The method is illustrated and validated by 3T experiments on phantoms and human brain.

journal_name

Magn Reson Med

authors

Helms G,Dathe H,Weiskopf N,Dechent P

doi

10.1002/mrm.22849

subject

Has Abstract

pub_date

2011-09-01 00:00:00

pages

669-77

issue

3

eissn

0740-3194

issn

1522-2594

journal_volume

66

pub_type

杂志文章
  • Assessment of quantitative artificial neural network analysis in a metabolically dynamic ex vivo 31P NMR pig liver study.

    abstract::Quantitative artificial neural network analysis for 1550 ex vivo 31P nuclear magnetic resonance spectra from hypothermically reperfused pig livers was assessed. These spectra show wide ranges of metabolite concentrations and have been analyzed using metabolite prior knowledge based lineshape fitting analysis which had...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380522

    authors: Ala-Korpela M,Changani KK,Hiltunen Y,Bell JD,Fuller BJ,Bryant DJ,Taylor-Robinson SD,Davidson BR

    更新日期:1997-11-01 00:00:00

  • Non-contrast-enhanced flow-independent peripheral MR angiography with balanced SSFP.

    abstract::Flow-independent angiography is a non-contrast-enhanced technique that can generate vessel contrast even with reduced blood flow in the lower extremities. A method is presented for producing these angiograms with magnetization-prepared balanced steady-state free precession (bSSFP). Because bSSFP yields bright fat sign...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21921

    authors: Cukur T,Lee JH,Bangerter NK,Hargreaves BA,Nishimura DG

    更新日期:2009-06-01 00:00:00

  • Cerebral glucose is detectable by localized proton NMR spectroscopy in normal rat brain in vivo.

    abstract::This contribution reports the first direct and noninvasive observation of cerebral glucose in normal anesthetized rats (n = 16) using short-echo-time localized proton NMR spectroscopy (2.35 T, STEAM, TR = 6000 ms, TE = 20 ms, 125 microliters). In addition to resonances from N-acetyl aspartate (NAA), glutamate, total c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190243

    authors: Gyngell ML,Michaelis T,Hörstermann D,Bruhn H,Hänicke W,Merboldt KD,Frahm J

    更新日期:1991-06-01 00:00:00

  • Reducing oblique flow effects in interleaved EPI with a centric reordering technique.

    abstract::Segmented interleaved echo planar imaging offers a fast and efficient approach to magnetic resonance angiography. Unfortunately, this technique is particularly sensitive to oblique flow in the imaging plane. In this work, a mathematical analysis of oblique flow effects for several types of k-space coverage is presente...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1084

    authors: Beck G,Li D,Haacke EM,Noll TG,Schad LR

    更新日期:2001-04-01 00:00:00

  • Improved sensitivity to overlapping multiplet signals in in vivo proton spectroscopy using a multiecho volume selective (CPRESS) experiment.

    abstract::A method for volume selective proton spectroscopy is presented based on a multiecho sequence with short refocusing interval tcp. It is demonstrated, that by appropriate choice of tcp on the order of 4-6 ms, signals from overlapping multiplets like the glutamine and glutamate (Glu/Gln) resonances in spectra of the huma...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370603

    authors: Hennig J,Thiel T,Speck O

    更新日期:1997-06-01 00:00:00

  • Motion robust respiratory-resolved 3D radial flow MRI and its application in neonatal congenital heart disease.

    abstract:PURPOSE:To test and implement a motion-robust and respiratory-resolved 3D Radial Flow framework that addresses the need for rapid, high resolution imaging in neonatal patients with congenital heart disease. METHODS:A 4-point velocity encoding and 3D radial trajectory with double-golden angle ordering was combined with...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27945

    authors: Schrauben EM,Lim JM,Goolaub DS,Marini D,Seed M,Macgowan CK

    更新日期:2020-02-01 00:00:00

  • Accelerated whole-heart MR angiography using a variable-density poisson-disc undersampling pattern and compressed sensing reconstruction.

    abstract:PURPOSE:To accelerate whole-heart three-dimension MR angiography (MRA) by using a variable-density Poisson-disc undersampling pattern and a compressed sensing (CS) reconstruction algorithm, and compare the results with sensitivity encoding (SENSE). METHODS:For whole-heart MRA, a prospective variable-density Poisson-di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26730

    authors: Moghari MH,Uecker M,Roujol S,Sabbagh M,Geva T,Powell AJ

    更新日期:2018-02-01 00:00:00

  • Simultaneous spin-echo refocusing.

    abstract::A new approach to spin-echo imaging is presented in which the 180 degrees RF pulse refocuses two or more spin-echoes at different positions in the readout period. When simultaneous echo refocusing (SER) is implemented using multiple 180 degrees pulses, an undesirable mixing of stimulated echoes and primary echoes from...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20587

    authors: Günther M,Feinberg DA

    更新日期:2005-09-01 00:00:00

  • Improved myocardial tagging contrast.

    abstract::Myocardial tagging is a new noninvasive MRI method that allows the study of myocardial motion with high accuracy. However, with conventional tagging techniques tagging contrast is impaired at later heart phases due to longitudinal relaxation. An improved method, called Complementary SPAtial Modulation of Magnetization...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300207

    authors: Fischer SE,McKinnon GC,Maier SE,Boesiger P

    更新日期:1993-08-01 00:00:00

  • Echo shape analysis and image size adjustment on the level of echoes: improvement of parameter-selective proton images.

    abstract::Parameter-selective imaging for tissue characterization is performed at low magnetic fields (0.24-0.28 T) employing echo trains with a large number of echoes (less than or equal to 50), high-power pulses, and the projection reconstruction method. Preprocessing of the raw echoes is important for the quality of the echo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030306

    authors: Staemmler M,Gersonde K

    更新日期:1986-06-01 00:00:00

  • Capillarization of the sinusoids in liver fibrosis: noninvasive assessment with contrast-enhanced MRI in the rabbit.

    abstract::Sinusoidal capillarization induces microcirculatory changes in liver cirrhosis and fibrosis. The purpose of this study was to assess whether contrast-enhanced MRI can be used to demonstrate the effects of sinusoidal capillarization in liver fibrosis. Dynamic MRI after injection of a low-molecular-weight contrast agent...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10420

    authors: Van Beers BE,Materne R,Annet L,Hermoye L,Sempoux C,Peeters F,Smith AM,Jamart J,Horsmans Y

    更新日期:2003-04-01 00:00:00

  • Imaging oxygen tension in liver and spleen by 19F NMR.

    abstract::19F NMR imaging of the perfluorocarbon emulsion Fluosol has been used to study regional variations in oxygen tension in rat liver and spleen. We have used the linear dependence of spin lattice relaxation rate (1/T1) on the partial oxygen pressure (pO2) of Fluosol to determine the oxygen tension in the reticuloendothel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290405

    authors: Holland SK,Kennan RP,Schaub MM,D'Angelo MJ,Gore JC

    更新日期:1993-04-01 00:00:00

  • Lateral geniculate activations can be detected using intersubject averaging and fMRI.

    abstract::Applications of fMRI in functional brain imaging are mainly confined to single subject designs, prohibiting the assessment of subject or group by condition interactions (i.e., differential activations) or areas of conjoint activation. In this paper a framework for fMRI group designs, using statistical parametric mappi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380502

    authors: Büchel C,Turner R,Friston K

    更新日期:1997-11-01 00:00:00

  • Modification of embolic-PVA particles with MR contrast agents.

    abstract::We report the synthesis and characterization of polyvinyl alcohol (PVA) embolic particles modified with a clinically approved magnetic resonance (MR) contrast agent. PVA particles are used during transcatheter arterial embolization (TAE) procedures and this minimally invasive technique is a widely employed treatment f...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21518

    authors: Cilliers R,Song Y,Kohlmeir EK,Larson AC,Omary RA,Meade TJ

    更新日期:2008-04-01 00:00:00

  • A 1H-NMR method for determining temperature in cell culture perfusion systems.

    abstract::This report describes a noninvasive 1H-NMR method for measuring absolute temperatures (+/- 0.2 degrees C) in biological samples and, in particular, in cell culture perfusion systems, utilizing the linear temperature dependence of the water chemical shift relative to the temperature-independent shift of one of the comp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290120

    authors: Lutz NW,Kuesel AC,Hull WE

    更新日期:1993-01-01 00:00:00

  • Accelerating magnetic resonance fingerprinting (MRF) using t-blipped simultaneous multislice (SMS) acquisition.

    abstract:PURPOSE:We incorporate simultaneous multislice (SMS) acquisition into MR fingerprinting (MRF) to accelerate the MRF acquisition. METHODS:The t-Blipped SMS-MRF method is achieved by adding a Gz blip before each data acquisition window and balancing it with a Gz blip of opposing polarity at the end of each TR. Thus the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25799

    authors: Ye H,Ma D,Jiang Y,Cauley SF,Du Y,Wald LL,Griswold MA,Setsompop K

    更新日期:2016-05-01 00:00:00

  • SSFP signal with finite RF pulses.

    abstract::The theoretical description of steady state free precession (SSFP) sequences is generally well accepted and unquestioned, although it is based on instantaneously acting radiofrequency (RF) pulses. In practice, however, all excitation processes are finite, thereby questioning the overall validity of the common SSFP sig...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22116

    authors: Bieri O,Scheffler K

    更新日期:2009-11-01 00:00:00

  • Parallel reconstruction using null operations.

    abstract::A novel iterative k-space data-driven technique, namely parallel reconstruction using null operations (PRUNO), is presented for parallel imaging reconstruction. In PRUNO, both data calibration and image reconstruction are formulated into linear algebra problems based on a generalized system model. An optimal data cali...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22899

    authors: Zhang J,Liu C,Moseley ME

    更新日期:2011-11-01 00:00:00

  • Stability constants and 1H relaxation effects of ternary complexes formed between Gd-DTPA, Gd-DTPA-BMA, Gd-DOTA, and Gd-EDTA and citrate, phosphate, and carbonate ions.

    abstract::Formation of ternary complexes between Gd-DTPA, Gd-DTPA-BMA, and Gd-DOTA, used as contrast enhancement agents in MRI and the endogenously available carbonate and phosphate ions, has been demonstrated. The extent of ternary complex formation and its effect on the proton relaxation, measured at 9 MHz, rates is negligibl...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380120

    authors: Burai L,Hietapelto V,Király R,Tóth E,Brücher E

    更新日期:1997-07-01 00:00:00

  • In vitro 1H NMR "mapping" of human intervertebral discs.

    abstract::Human intervertebral discs were investigated by 1H NMR in vitro. The measured parameters of samples differently located in discs give the "maps" of discs. The spin-lattice relaxation-time maps show similar structure to dry matter and bound water maps, which might mean the future possibility to detect certain disc proc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030122

    authors: Furó I,Bobest M,Pócsik I,Tompa K

    更新日期:1986-02-01 00:00:00

  • Cardiac real-time imaging using SENSE. SENSitivity Encoding scheme.

    abstract::Sensitivity encoding is used to improve the performance of real-time MRI. The encoding efficiency of single-shot and segmented echo-planar imaging is tripled by means of a 6-element receiver coil array. The feasibility of this approach is verified for double oblique cardiac real-time imaging of human subjects at rest ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200002)43:2<177::aid-mrm3>

    authors: Weiger M,Pruessmann KP,Boesiger P

    更新日期:2000-02-01 00:00:00

  • A pitfall associated with lactate detection using stimulated-echo proton spectroscopy.

    abstract::At TE values of 136 ms, it has recently been shown that the lactate methyl signal, when obtained with a stimulated-echo (STE) sequence, is modulated at the zero-quantum (ZQ) frequency when TM is varied. Here we describe an additional modulation of the ZQ lactate signal, due to spin-spin coupling, that results in a 10-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170223

    authors: Sotak CH,Alger JR

    更新日期:1991-02-01 00:00:00

  • Improved large tip angle parallel transmission pulse design through a perturbation analysis of the Bloch equation.

    abstract::Parallel transmission has emerged as an efficient means for implementing multidimensional spatially selective radiofrequency excitation pulses. To date, most theoretical and experimental work on parallel transmission radiofrequency (RF) pulse design is based on the small-tip-angle approximation to the Bloch equation. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22827

    authors: Zheng H,Zhao T,Qian Y,Ibrahim TS,Boada FE

    更新日期:2011-09-01 00:00:00

  • Combined dynamic contrast-enhanced liver MRI and MRA using interleaved variable density sampling.

    abstract:PURPOSE:To develop and evaluate a method for volumetric contrast-enhanced MRI of the liver, with high spatial and temporal resolutions, for combined dynamic imaging and MR angiography (MRA) using a single injection of contrast agent. METHODS:An interleaved variable density (IVD) undersampling pattern was implemented i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25195

    authors: Salmani Rahimi M,Korosec FR,Wang K,Holmes JH,Motosugi U,Bannas P,Reeder SB

    更新日期:2015-03-01 00:00:00

  • Investigating cardiac stimulation limits of MRI gradient coils using electromagnetic and electrophysiological simulations in human and canine body models.

    abstract:PURPOSE:Cardiac stimulation (CS) limits to gradient coil switching speed are difficult to measure in humans; instead, current regulatory guidelines (IEC 60601-2-33) are based on animal experiments and electric field-to-dB/dt conversion factors computed for a simple, homogeneous body model. We propose improvement to thi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28472

    authors: Klein V,Davids M,Schad LR,Wald LL,Guérin B

    更新日期:2021-02-01 00:00:00

  • Introduction of the snake antenna array: Geometry optimization of a sinusoidal dipole antenna for 10.5T body imaging with lower peak SAR.

    abstract:PURPOSE:To improve imaging performance for body MRI with a local transmit array at 10.5T, the geometry of a dipole antenna was optimized to achieve lower peak specific absorption rate (SAR) levels and a more uniform transmit profile. METHODS:Electromagnetic simulations on a phantom were used to evaluate the SAR and ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28297

    authors: Steensma B,van de Moortele PF,Ertürk A,Grant A,Adriany G,Luijten P,Klomp D,van den Berg N,Metzger G,Raaijmakers A

    更新日期:2020-11-01 00:00:00

  • Self-calibrating parallel imaging with automatic coil sensitivity extraction.

    abstract::Calibration of the spatial sensitivity functions of coil arrays is a crucial element in parallel magnetic resonance imaging (PMRI). The most common approach has been to measure coil sensitivities directly using one or more low-resolution images acquired before or after accelerated data acquisition. However, since it i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10087

    authors: McKenzie CA,Yeh EN,Ohliger MA,Price MD,Sodickson DK

    更新日期:2002-03-01 00:00:00

  • Fast multislice T(1) and t(1sat) imaging using a phase acquisition of composite echoes (PACE) technique.

    abstract::An optimized multislice data acquisition scheme for phase acquisition of composite echoes (PACE) imaging is presented. This new scheme uses a repetition time equal to the mixing time and an appropriate phase cycling scheme, which allows for more efficient exploitation of all composite echoes. These modifications provi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199912)42:6<1089::aid-mrm1

    authors: Ropele S,Stollberger R,Kapeller P,Hartung HP,Fazekas F

    更新日期:1999-12-01 00:00:00

  • Reducing gradient imperfections for spiral magnetic resonance spectroscopic imaging.

    abstract::Spiral k-space magnetic resonance spectroscopic imaging (MRSI) requires high performance from gradient hardware systems. During the readout phase, oscillating gradients are continuously played out, which can cause undesired effects. These effects on the quality of SI data are non-intuitive because of their time-varyin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20928

    authors: Kim DH,Spielman DM

    更新日期:2006-07-01 00:00:00

  • Driving mutually coupled gradient array coils in magnetic resonance imaging.

    abstract:PURPOSE:In contrast to conventional linear gradients, gradient coil arrays with arbitrary spatial dependency might experience strong mutual coupling. Although conventional gradient power amplifiers with feedback loop might compensate the effect of coupling, required voltages for the compensation are generally unknown a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27768

    authors: Ertan K,Taraghinia S,Atalar E

    更新日期:2019-09-01 00:00:00