SSFP signal with finite RF pulses.

Abstract:

:The theoretical description of steady state free precession (SSFP) sequences is generally well accepted and unquestioned, although it is based on instantaneously acting radiofrequency (RF) pulses. In practice, however, all excitation processes are finite, thereby questioning the overall validity of the common SSFP signal description for use with finite RF pulses. In this paper, finite RF pulse effects on balanced SSFP signal formation are analyzed as a function of the RF time, the pulse repetition time, the flip angle (alpha) and relaxation times (T(1,2)). The observed signal modulations from finite RF pulses (compared to infinitesimal ones) can range from only a few percent (for RF time/pulse repetition time < 1, alpha < 90 degrees, T(2)/T(1) approximately 1) to over 10% (for RF time/pulse repetition time < 1, alpha approximately 90 degrees, T(2)/T(1) < 1) and may even exceed 100% in the limit of RF time/pulse repetition time --> 1 (for alpha approximately 90 degrees, T(2)/T(1) < 1). As a result, a revision of SSFP signal theory is indicated not only for reasons of completeness but also seems advisable, e.g., for all quantitative SSFP methods. A simple modification for the common balanced SSFP equation is derived that provides an accurate framework for SSFP signal description over a wide variety of practical and physiologic parameters.

journal_name

Magn Reson Med

authors

Bieri O,Scheffler K

doi

10.1002/mrm.22116

subject

Has Abstract

pub_date

2009-11-01 00:00:00

pages

1232-41

issue

5

eissn

0740-3194

issn

1522-2594

journal_volume

62

pub_type

杂志文章
  • Incorporating dixon multi-echo fat water separation for novel quantitative magnetization transfer of the human optic nerve in vivo.

    abstract:PURPOSE:The optic nerve (ON) represents the sole pathway between the eyes and brain; consequently, diseases of the ON can have dramatic effects on vision. However, quantitative magnetization transfer (qMT) applications in the ON have been limited to ex vivo studies, in part because of the fatty connective tissue that s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26164

    authors: Smith AK,Dortch RD,Dethrage LM,Lyttle BD,Kang H,Welch EB,Smith SA

    更新日期:2017-02-01 00:00:00

  • Minimization of dead-periods in MRI pulse sequences for imaging oblique planes.

    abstract::With the advent of breath-hold MR cardiac imaging techniques, the minimization of TR and TE for oblique planes has become a critical issue. The slew rates and maximum currents of gradient amplifiers limit the minimum possible TR and TE by adding dead-periods to the pulse sequences. We propose a method of designing gra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320613

    authors: Atalar E,McVeigh ER

    更新日期:1994-12-01 00:00:00

  • Effect of lanthanide ions on dynamic nuclear polarization enhancement and liquid-state T1 relaxation.

    abstract::In the dynamic nuclear polarization process, microwave irradiation facilitates exchange of polarization from a radical's unpaired electron to nuclear spins at cryogenic temperatures, increasing polarization by >10,000. Doping samples with Gd(3+) ions further increases the achievable solid-state polarization. However, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24207

    authors: Gordon JW,Fain SB,Rowland IJ

    更新日期:2012-12-01 00:00:00

  • Development of the human brain: in vivo quantification of metabolite and water content with proton magnetic resonance spectroscopy.

    abstract::Cerebral metabolite concentrations and water content were measured by means of localized proton magnetic resonance spectroscopy in 50 children, while metabolite peak ratios in short echo time spectra were evaluated in 173 examinations. Normative curves for normal development were established for two cerebral locations...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300405

    authors: Kreis R,Ernst T,Ross BD

    更新日期:1993-10-01 00:00:00

  • Oxygen extraction fraction mapping at 3 Tesla using an artificial neural network: A feasibility study.

    abstract:PURPOSE:The oxygen extraction fraction (OEF) is an important biomarker for tissue-viability. MRI enables noninvasive estimation of the OEF based on the blood-oxygenation-level-dependent (BOLD) effect. Quantitative OEF-mapping is commonly applied using least-squares regression (LSR) to an analytical tissue model. Howeve...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26749

    authors: Domsch S,Mürle B,Weingärtner S,Zapp J,Wenz F,Schad LR

    更新日期:2018-02-01 00:00:00

  • Automatic segmentation of the brain and intracranial cerebrospinal fluid in T1-weighted volume MRI scans of the head, and its application to serial cerebral and intracranial volumetry.

    abstract::A new fully automatic algorithm for the segmentation of the brain and total intracranial cerebrospinal fluid (CSF) from T(1)-weighted volume MRI scans of the head, called Exbrain v.2, is described. The algorithm was developed in the context of serial intracranial volumetry. A brain mask obtained using a previous versi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10436

    authors: Lemieux L,Hammers A,Mackinnon T,Liu RS

    更新日期:2003-05-01 00:00:00

  • A comparison of static and dynamic ∆B0 mapping methods for correction of CEST MRI in the presence of temporal B0 field variations.

    abstract:PURPOSE:To assess the performance, in the presence of scanner instabilities, of three dynamic correction methods which integrate ∆B0 mapping into the chemical exchange saturation transfer (CEST) measurement and three established static ∆B0 -correction approaches. METHODS:A homogeneous phantom and five healthy voluntee...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27750

    authors: Poblador Rodriguez E,Moser P,Dymerska B,Robinson S,Schmitt B,van der Kouwe A,Gruber S,Trattnig S,Bogner W

    更新日期:2019-08-01 00:00:00

  • Fast measurement of blood T1 in the human carotid artery at 3T: Accuracy, precision, and reproducibility.

    abstract:PURPOSE:To develop a fast protocol for measuring T1 values in the internal carotid artery (ICA), to validate this technique with in vitro measurements, and to evaluate its reproducibility. METHODS:A modified Look-Locker sequence was optimized to enable rapid determination of T1 in the ICA at 3T. T1 values from the ICA...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26325

    authors: Li W,Liu P,Lu H,Strouse JJ,van Zijl PCM,Qin Q

    更新日期:2017-06-01 00:00:00

  • Perfusion-based functional magnetic resonance imaging with single-shot RARE and GRASE acquisitions.

    abstract::For perfusion-based functional magnetic resonance imaging, the previously introduced flow-sensitive alternating inversion recovery (FAIR) technique is combined with single-shot RARE (rapid acquisition with relaxation enhancement) and GRASE (gradient and spin echo) imaging sequences. The advantages of these sequences c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199901)41:1<132::aid-mrm18

    authors: Crelier GR,Hoge RD,Munger P,Pike GB

    更新日期:1999-01-01 00:00:00

  • Quantitative framework for prospective motion correction evaluation.

    abstract:PURPOSE:Establishing a framework to evaluate performances of prospective motion correction (PMC) MRI considering motion variability between MRI scans. METHODS:A framework was developed to obtain quantitative comparisons between different motion correction setups, considering that varying intrinsic motion patterns betw...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25580

    authors: Pannetier NA,Stavrinos T,Ng P,Herbst M,Zaitsev M,Young K,Matson G,Schuff N

    更新日期:2016-02-01 00:00:00

  • Dual-polarity slice-GRAPPA for concurrent ghost correction and slice separation in simultaneous multi-slice EPI.

    abstract:PURPOSE:A ghost correction strategy for Simultaneous Multi-Slice (SMS) EPI methods that provides improved ghosting artifact reduction compared to conventional methods is presented. Conventional Nyquist ghost correction methods for SMS-EPI rely on navigator data that contain phase errors from all slices in the simultane...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27113

    authors: Hoge WS,Setsompop K,Polimeni JR

    更新日期:2018-10-01 00:00:00

  • A PRESTO-SENSE sequence with alternating partial-Fourier encoding for rapid susceptibility-weighted 3D MRI time series.

    abstract::A 3D sequence for dynamic susceptibility imaging is proposed which combines echo-shifting principles (such as PRESTO), sensitivity encoding (SENSE), and partial-Fourier acquisition. The method uses a moderate SENSE factor of 2 and takes advantage of an alternating partial k-space acquisition in the "slow" phase encode...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10599

    authors: Klarhöfer M,Dilharreguy B,van Gelderen P,Moonen CT

    更新日期:2003-10-01 00:00:00

  • Local specific absorption rate in brain tumors at 7 tesla.

    abstract:PURPOSE:MR safety at 7 Tesla relies on accurate numerical simulations of transmit electromagnetic fields to fully assess local specific absorption rate (SAR) safety. Numerical simulations for SAR safety are currently performed using models of healthy patients. These simulations might not be useful for estimating SAR in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25653

    authors: Restivo MC,van den Berg CA,van Lier AL,Polders DL,Raaijmakers AJ,Luijten PR,Hoogduin H

    更新日期:2016-01-01 00:00:00

  • Gradient characterization using a Fourier-transform technique.

    abstract::This paper describes a technique for characterizing the gradient subsystem of a magnetic resonance (MR) system. The technique uses a Fourier-transform analysis to directly measure the k-space trajectory produced by an arbitrary gradient waveform. In addition, the method can be easily extended to multiple dimensions an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390411

    authors: Alley MT,Glover GH,Pelc NJ

    更新日期:1998-04-01 00:00:00

  • Intracellular and extracellular spaces and the direct quantification of molar intracellular concentrations of phosphorus metabolites in the isolated rat heart using 31P NMR spectroscopy and phosphonate markers.

    abstract::To quantify metabolite and cation concentrations using NMR spectroscopy, the volumes of intracellular and extracellular spaces must be known. We describe a simple 31P NMR spectroscopic method that employs dimethyl methylphosphonate (DMMP) as a marker of total water space and phenylphosphonate (PPA) as a marker of extr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320206

    authors: Clarke K,Anderson RE,Nédélec JF,Foster DO,Ally A

    更新日期:1994-08-01 00:00:00

  • Is the detection of fucose cancer markers by 2D 1H NMR unequivocal?

    abstract::Fucose is believed to be a marker for cancer that may be detectable by the 2D proton NMR (COSY) of human plasma. However, the COSY technique is time consuming and prone to error. These problems may be alleviated by using the SUPERCOSY pulse sequence; this technique shows that there are many other cross peaks in the re...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910150102

    authors: Phillips PS,Herring FG

    更新日期:1990-07-01 00:00:00

  • Safety of gadolinium-DTPA: extended clinical experience.

    abstract::This review reports data on the general and renal tolerance of the paramagnetic contrast agent Gd-DTPA after intravenous administration. Gd-DTPA was administered usually at a dose level of 0.1-0.2 mmol/kg body wt (range: 0.005-0.25 mmol/kg body wt) in cranial, spinal and body MR indications. In phase I-IIIa studies a ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.1910220212

    authors: Niendorf HP,Haustein J,Cornelius I,Alhassan A,Clauss W

    更新日期:1991-12-01 00:00:00

  • Multivendor implementation and comparison of volumetric whole-brain echo-planar MR spectroscopic imaging.

    abstract:PURPOSE:To assess volumetric proton MR spectroscopic imaging (MRSI) of the human brain on multivendor MRI instruments. METHODS:Echo-planar spectroscopic imaging was developed on instruments from three manufacturers, with matched specifications and acquisition protocols that accounted for differences in sampling perfor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25510

    authors: Sabati M,Sheriff S,Gu M,Wei J,Zhu H,Barker PB,Spielman DM,Alger JR,Maudsley AA

    更新日期:2015-11-01 00:00:00

  • Dynamic liver imaging with iron oxide agents: effects of size and biodistribution on contrast.

    abstract::In vivo effective relaxation rates in normal rat liver were evaluated for four dextran coated iron oxide agents: monocrystalline iron oxide nanocolloid (MION) with a mean particle diameter of 3.9 nm, a polycrystalline agent (PION) with a larger mean diameter of 12 nm, and these two agents labeled with the asialofetuin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370613

    authors: Mandeville JB,Moore J,Chesler DA,Garrido L,Weissleder R,Weisskoff RM

    更新日期:1997-06-01 00:00:00

  • Rapid acquisition of helium-3 and proton three-dimensional image sets of the human lung in a single breath-hold using compressed sensing.

    abstract:PURPOSE:To develop and validate a method for acquiring helium-3 ((3) He) and proton ((1) H) three-dimensional (3D) image sets of the human lung with isotropic spatial resolution within a 10-s breath-hold by using compressed sensing (CS) acceleration, and to assess the fidelity of undersampled images compared with fully...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25499

    authors: Qing K,Altes TA,Tustison NJ,Feng X,Chen X,Mata JF,Miller GW,de Lange EE,Tobias WA,Cates GD Jr,Brookeman JR,Mugler JP 3rd

    更新日期:2015-10-01 00:00:00

  • Magnetic resonance imaging of blood vessels at high fields: in vivo and in vitro measurements and image simulation.

    abstract::Unusually high image contrast in vivo magnetic resonance imaging of the brain becomes observable at high magnetic fields when the blood oxygenation level is lowered. The cause of the contrast has been attributed to a magnetic susceptibility effect induced by paramagnetic deoxyhemoglobin in red cells. When the cylinder...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910160103

    authors: Ogawa S,Lee TM

    更新日期:1990-10-01 00:00:00

  • In vivo 3.0-tesla magnetic resonance T1rho and T2 relaxation mapping in subjects with intervertebral disc degeneration and clinical symptoms.

    abstract::The purpose of this study is (1) to determine the correlation between T(1rho) and T(2) and degenerative grade in intervertebral discs using in vivo 3.0-T MRI, and (2) to determine the association between T(1rho) and T(2) and clinical findings as quantified by the SF-36 Questionnaire and Oswestry Disability Index. Sixt...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22362

    authors: Blumenkrantz G,Zuo J,Li X,Kornak J,Link TM,Majumdar S

    更新日期:2010-05-01 00:00:00

  • A new susceptibility-weighted image reconstruction method for the reduction of background phase artifacts.

    abstract:PURPOSE:To significantly reduce the background phase effects, especially at the air-tissue interface, and to enhance the desirable local structures of veins in susceptibility-weighted imaging. METHODS:In the proposed reconstruction method called Magnitude of Complex Filtering, a complex-valued magnetic resonance image...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24776

    authors: Lee Y,Han Y,Park H

    更新日期:2014-03-01 00:00:00

  • Deuterium magnetic resonance imaging of rabbit eye in vivo.

    abstract::We used deuterium magnetic resonance imaging (2H MRI) to visualize water movement in the rabbit eye. Dynamic 2H MRI was obtained every 3.5 min at 2 tesla by FLASH pulse sequence (TR, 300 ms; TE, 10 ms; alpha = 90 degrees) with a slice thickness of 10 mm using a surface coil (4 cm in diameter). After topical administra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330417

    authors: Obata T,Ikehira H,Koga M,Yoshida K,Kimura F,Tateno Y

    更新日期:1995-04-01 00:00:00

  • A flexible nested sodium and proton coil array with wideband matching for knee cartilage MRI at 3T.

    abstract:PURPOSE:We describe a 2 × 6 channel sodium/proton array for knee MRI at 3T. Multielement coil arrays are desirable because of well-known signal-to-noise ratio advantages over volume and single-element coils. However, low tissue-coil coupling that is characteristic of coils operating at low frequency can make the potent...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26017

    authors: Brown R,Lakshmanan K,Madelin G,Alon L,Chang G,Sodickson DK,Regatte RR,Wiggins GC

    更新日期:2016-10-01 00:00:00

  • A flexible fast spin echo triple-echo Dixon technique.

    abstract:PURPOSE:To develop a flexible fast spin echo (FSE) triple-echo Dixon (FTED) technique. METHODS:An FSE pulse sequence was modified by replacing each readout gradient with three fast-switching bipolar readout gradients with minimal interecho dead time. The corresponding three echoes were used to generate three raw image...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26186

    authors: Son JB,Hwang KP,Madewell JE,Bayram E,Hazle JD,Low RN,Ma J

    更新日期:2017-03-01 00:00:00

  • Materials and methods for higher performance screen-printed flexible MRI receive coils.

    abstract:PURPOSE:To develop methods for characterizing materials used in screen-printed MRI coils and improve signal-to-noise ratio (SNR) with new lower-loss materials. METHODS:An experimental apparatus was created to characterize dielectric properties of plastic substrates used in receive coils. Coils were fabricated by scree...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26399

    authors: Corea JR,Lechene PB,Lustig M,Arias AC

    更新日期:2017-08-01 00:00:00

  • Coronary MR angiography using image-based respiratory motion compensation with inline correction and fixed gating efficiency.

    abstract:PURPOSE:The purpose of this study was to evaluate a new inline motion compensation approach called image-based navigation with Constant Respiratory efficiency UsIng Single End-expiratory threshold (iNAV-CRUISE) for coronary MR angiography (CMRA). METHODS:The CRUISE gating technique was combined with iNAV motion correc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26678

    authors: Henningsson M,Smink J,van Ensbergen G,Botnar R

    更新日期:2018-01-01 00:00:00

  • Quantitative susceptibility mapping detects abnormalities in cartilage canals in a goat model of preclinical osteochondritis dissecans.

    abstract:PURPOSE:To use quantitative susceptibility mapping (QSM) to investigate changes in cartilage canals in the distal femur of juvenile goats after their surgical transection. METHODS:Chondronecrosis was surgically induced in the right medial femoral condyles of four 4-day-old goats. Both the operated and control knees we...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26214

    authors: Wang L,Nissi MJ,Toth F,Johnson CP,Garwood M,Carlson CS,Ellermann J

    更新日期:2017-03-01 00:00:00

  • Non-contrast-enhanced flow-independent peripheral MR angiography with balanced SSFP.

    abstract::Flow-independent angiography is a non-contrast-enhanced technique that can generate vessel contrast even with reduced blood flow in the lower extremities. A method is presented for producing these angiograms with magnetization-prepared balanced steady-state free precession (bSSFP). Because bSSFP yields bright fat sign...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21921

    authors: Cukur T,Lee JH,Bangerter NK,Hargreaves BA,Nishimura DG

    更新日期:2009-06-01 00:00:00