A comparison of static and dynamic ∆B0 mapping methods for correction of CEST MRI in the presence of temporal B0 field variations.

Abstract:

PURPOSE:To assess the performance, in the presence of scanner instabilities, of three dynamic correction methods which integrate ∆B0 mapping into the chemical exchange saturation transfer (CEST) measurement and three established static ∆B0 -correction approaches. METHODS:A homogeneous phantom and five healthy volunteers were scanned with a CEST sequence at 7 T. The in vivo measurements were performed twice: first with unaltered system frequency and again applying frequency shifts during the CEST acquisition. In all cases, retrospective voxel-wise ∆B0 -correction was performed using one intrinsic and two extrinsic [prescans with dual-echo gradient-echo and water saturation shift referencing (WASSR)] static approaches. These were compared with two intrinsic [using phase data directly generated by single-echo or double-echo GRE (gradient-echo) CEST readout (CEST-GRE-2TE)] and one extrinsic [phase from interleaved dual-echo EPI (echo planar imaging) navigator (NAV-EPI-2TE)] dynamic ∆B0 -correction approaches [allowing correction of each Z-spectral point before magnetization transfer ratio asymmetry (MTRasym) analysis]. RESULTS:All three dynamic methods successfully mapped the induced drift. The intrinsic approaches were affected by the CEST labeling near water (∆ω < |0.3| ppm). The MTRasym contrast was distorted by the frequency drift in the brain by up to 0.21%/Hz when static ∆B0 -corrections were applied, whereas the dynamic ∆B0 corrections reduced this to <0.01%/Hz without the need of external scans. The CEST-GRE-2TE and NAV-EPI-2TE resulted in highly consistent MTRasym values with/without drift for all subjects. CONCLUSION:Reliable correction of scanner instabilities is essential to establish clinical CEST MRI. The three dynamic approaches presented improved the ∆B0 -correction performance significantly in the presence of frequency drift compared to established static methods. Among them, the self-corrected CEST-GRE-2TE was the most accurate and straightforward to implement.

journal_name

Magn Reson Med

authors

Poblador Rodriguez E,Moser P,Dymerska B,Robinson S,Schmitt B,van der Kouwe A,Gruber S,Trattnig S,Bogner W

doi

10.1002/mrm.27750

subject

Has Abstract

pub_date

2019-08-01 00:00:00

pages

633-646

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

82

pub_type

杂志文章
  • Nonuniform and multidimensional Shinnar-Le Roux RF pulse design method.

    abstract::The Shinnar-Le Roux (SLR) radiofrequency (RF) pulse design algorithm is widely used for designing slice-selective RF pulses due to its intuitiveness, optimality, and speed. SLR is limited, however, in that it is only capable of designing one-dimensional pulses played along constant gradients. We present a nonuniform S...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23269

    authors: Grissom WA,McKinnon GC,Vogel MW

    更新日期:2012-09-01 00:00:00

  • Semiautomated spleen volumetry with diffusion-weighted MR imaging.

    abstract::In this article, we determined the relative accuracy of semiautomated spleen volumetry with diffusion-weighted (DW) MR images compared to standard manual volumetry with DW-MR or CT images. Semiautomated spleen volumetry using simple thresholding followed by 3D and 2D connected component analysis was performed with DW-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23204

    authors: Lee J,Kim KW,Lee H,Lee SJ,Choi S,Jeong WK,Kye H,Song GW,Hwang S,Lee SG

    更新日期:2012-07-01 00:00:00

  • Decomposition of inflow and blood oxygen level-dependent (BOLD) effects with dual-echo spiral gradient-recalled echo (GRE) fMRI.

    abstract::Image contrast with gradient-recalled echo sequences (GRE) used for fMRI can have both blood oxygen level-dependent (BOLD) and inflow components, and the latter is often undesirable. A dual-echo technique can be used to differentiate these mechanisms, because modulation of signal from inflow is common to both echoes, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350306

    authors: Glover GH,Lemieux SK,Drangova M,Pauly JM

    更新日期:1996-03-01 00:00:00

  • Imaging of single human carcinoma cells in vitro using a clinical whole-body magnetic resonance scanner at 3.0 T.

    abstract::The purpose of the present study was to examine whether single human carcinoma cells labeled with iron oxide nanoparticles could be detected by magnetic resonance (MR) imaging on a clinical 3-T scanner using a surface coil only. WiDr human colon carcinoma cells were loaded with two kinds of iron oxide nanoparticles di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20455

    authors: Pinkernelle J,Teichgräber U,Neumann F,Lehmkuhl L,Ricke J,Scholz R,Jordan A,Bruhn H

    更新日期:2005-05-01 00:00:00

  • Gradient characterization using a Fourier-transform technique.

    abstract::This paper describes a technique for characterizing the gradient subsystem of a magnetic resonance (MR) system. The technique uses a Fourier-transform analysis to directly measure the k-space trajectory produced by an arbitrary gradient waveform. In addition, the method can be easily extended to multiple dimensions an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390411

    authors: Alley MT,Glover GH,Pelc NJ

    更新日期:1998-04-01 00:00:00

  • Materials and methods for higher performance screen-printed flexible MRI receive coils.

    abstract:PURPOSE:To develop methods for characterizing materials used in screen-printed MRI coils and improve signal-to-noise ratio (SNR) with new lower-loss materials. METHODS:An experimental apparatus was created to characterize dielectric properties of plastic substrates used in receive coils. Coils were fabricated by scree...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26399

    authors: Corea JR,Lechene PB,Lustig M,Arias AC

    更新日期:2017-08-01 00:00:00

  • Preserving the accuracy and resolution of the sodium bioscale from quantitative sodium MRI during intrasubject alignment across longitudinal studies.

    abstract::Emerging applications of sodium bioscales derived from quantitative sodium magnetic resonance imaging assess temporal changes in regional sodium concentration over intervals that vary from hours (monitoring tissue viability in stroke) to weeks (monitoring brain tumor treatment during radiation therapy) or even years (...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23285

    authors: Atkinson IC,Lu A,Thulborn KR

    更新日期:2012-09-01 00:00:00

  • Dynamic liver imaging with iron oxide agents: effects of size and biodistribution on contrast.

    abstract::In vivo effective relaxation rates in normal rat liver were evaluated for four dextran coated iron oxide agents: monocrystalline iron oxide nanocolloid (MION) with a mean particle diameter of 3.9 nm, a polycrystalline agent (PION) with a larger mean diameter of 12 nm, and these two agents labeled with the asialofetuin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370613

    authors: Mandeville JB,Moore J,Chesler DA,Garrido L,Weissleder R,Weisskoff RM

    更新日期:1997-06-01 00:00:00

  • Fast three-dimensional inner volume excitations using parallel transmission and optimized k-space trajectories.

    abstract:PURPOSE:To design short parallel transmission (pTx) pulses for excitation of arbitrary three-dimensional (3D) magnetization patterns. METHODS:We propose a joint optimization of the pTx radiofrequency (RF) and gradient waveforms for excitation of arbitrary 3D magnetization patterns. Our optimization of the gradient wav...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26021

    authors: Davids M,Schad LR,Wald LL,Guérin B

    更新日期:2016-10-01 00:00:00

  • Development and validation of 3D MP-SSFP to enable MRI in inhomogeneous magnetic fields.

    abstract:PURPOSE:We demonstrate the feasibility of MRI with missing-pulse steady-state free precession (MP-SSFP) in a 4T magnet with artificially degraded homogeneity. METHODS:T1 , T2 , and diffusion contrast of MP-SSFP was simulated with constant and alternate radiofrequency (RF) phase using an extended phase graph. To valida...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28469

    authors: Kobayashi N,Parkinson B,Idiyatullin D,Adriany G,Theilenberg S,Juchem C,Garwood M

    更新日期:2021-02-01 00:00:00

  • Isotropic 3D cardiac cine MRI allows efficient sparse segmentation strategies based on 3D surface reconstruction.

    abstract:PURPOSE:Segmentation of cardiac cine MRI data is routinely used for the volumetric analysis of cardiac function. Conventionally, 2D contours are drawn on short-axis (SAX) image stacks with relatively thick slices (typically 8 mm). Here, an acquisition/reconstruction strategy is used for obtaining isotropic 3D cine data...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26923

    authors: Odille F,Bustin A,Liu S,Chen B,Vuissoz PA,Felblinger J,Bonnemains L

    更新日期:2018-05-01 00:00:00

  • Modulation of water diffusion during gonadotropin-induced ovulation: NMR microscopy of the ovarian follicle.

    abstract::The preovulatory rat follicle reaches a diameter of 1 mm with no internal blood vessels. Nutrient supply to the enclosed oocyte depends solely on passive diffusion across the follicular wall and the follicular fluid. Spin-echo and stimulated-echo NMR microscopy experiments were applied here for studying modulations in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340212

    authors: Tempel C,Schiffenbauer YS,Meir G,Neeman M

    更新日期:1995-08-01 00:00:00

  • Reweighted ℓ1 referenceless PRF shift thermometry.

    abstract::Temperature estimation in proton resonance frequency (PRF) shift MR thermometry requires a reference, or pretreatment, phase image that is subtracted from image phase during thermal treatment to yield a phase difference image proportional to temperature change. Referenceless thermometry methods derive a reference phas...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22502

    authors: Grissom WA,Lustig M,Holbrook AB,Rieke V,Pauly JM,Butts-Pauly K

    更新日期:2010-10-01 00:00:00

  • Reproducibility study of whole-brain 1H spectroscopic imaging with automated quantification.

    abstract::A reproducibility study of proton MR spectroscopic imaging ((1)H-MRSI) of the human brain was conducted to evaluate the reliability of an automated 3D in vivo spectroscopic imaging acquisition and associated quantification algorithm. A PRESS-based pulse sequence was implemented using dualband spectral-spatial RF pulse...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21713

    authors: Gu M,Kim DH,Mayer D,Sullivan EV,Pfefferbaum A,Spielman DM

    更新日期:2008-09-01 00:00:00

  • Minimization of dead-periods in MRI pulse sequences for imaging oblique planes.

    abstract::With the advent of breath-hold MR cardiac imaging techniques, the minimization of TR and TE for oblique planes has become a critical issue. The slew rates and maximum currents of gradient amplifiers limit the minimum possible TR and TE by adding dead-periods to the pulse sequences. We propose a method of designing gra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320613

    authors: Atalar E,McVeigh ER

    更新日期:1994-12-01 00:00:00

  • Data-driven optimized flip angle selection for T1 estimation from spoiled gradient echo acquisitions.

    abstract:PURPOSE:Define criteria for selection of optimal flip angle sets for T1 estimation and evaluate effects on T1 mapping. THEORY AND METHODS:Flip angle sets for spoiled gradient echo-based T1 mapping were selected by minimizing T1 estimate variance weighted by the joint density of M0 and T1 in an initial acquisition. The...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25920

    authors: Lewis CM,Hurley SA,Meyerand ME,Koay CG

    更新日期:2016-09-01 00:00:00

  • A 1H-NMR method for determining temperature in cell culture perfusion systems.

    abstract::This report describes a noninvasive 1H-NMR method for measuring absolute temperatures (+/- 0.2 degrees C) in biological samples and, in particular, in cell culture perfusion systems, utilizing the linear temperature dependence of the water chemical shift relative to the temperature-independent shift of one of the comp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290120

    authors: Lutz NW,Kuesel AC,Hull WE

    更新日期:1993-01-01 00:00:00

  • Accelerated whole-heart MR angiography using a variable-density poisson-disc undersampling pattern and compressed sensing reconstruction.

    abstract:PURPOSE:To accelerate whole-heart three-dimension MR angiography (MRA) by using a variable-density Poisson-disc undersampling pattern and a compressed sensing (CS) reconstruction algorithm, and compare the results with sensitivity encoding (SENSE). METHODS:For whole-heart MRA, a prospective variable-density Poisson-di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26730

    authors: Moghari MH,Uecker M,Roujol S,Sabbagh M,Geva T,Powell AJ

    更新日期:2018-02-01 00:00:00

  • Simple analytical dual-band spectral-spatial RF pulses for B(1) + and susceptibility artifact reduction in gradient echo MRI.

    abstract::Susceptibility artifacts and transmission radio frequency (RF) field (B(1) +) inhomogeneity are major limitations in high-field gradient echo MRI. Previously proposed numerical 2D spectral-spatial RF pulses have been shown to be promising for reducing the through-plane signal loss susceptibility artifact by incorporat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22725

    authors: Yang C,Deng W,Stenger VA

    更新日期:2011-02-01 00:00:00

  • Observing curved flow using RUFIS.

    abstract::The rotating ultra-fast imaging sequence (RUFIS) is used to image spins flowing through the curved portion of a 180 degrees U-tube with a circular cross section and a ratio of inner diameter to curvature diameter of 0.41. A velocity-encoding preparation sequence is used with RUFIS to measure quantitatively the axial v...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199906)41:6<1258::aid-mrm2

    authors: Gach HM,Lowe IJ

    更新日期:1999-06-01 00:00:00

  • Phase-updated regularized SENSE for navigator-free multishot diffusion imaging.

    abstract:PURPOSE:Either SENSE+CG or POCS-ICE methods can be used to correct for motion-induced phase errors in navigator-free multishot diffusion imaging. SENSE+CG has the advantage of a fast convergence, however, occasionally the convergence can be unstable, thus degrading the image quality. POCS-ICE has a stable convergence a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26361

    authors: Hu Z,Ma X,Truong TK,Song AW,Guo H

    更新日期:2017-07-01 00:00:00

  • A subspace-based coil combination method for phased-array magnetic resonance imaging.

    abstract:PURPOSE:Coil-by-coil reconstruction methods are followed by coil combination to obtain a single image representing a spin density map. Typical coil combination methods, such as square-root sum-of-squares and adaptive coil combining, yield images that exhibit spatially varying modulation of image intensity. Existing pra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25664

    authors: Gol Gungor D,Potter LC

    更新日期:2016-02-01 00:00:00

  • Improved quantification of myocardial blood flow using highly constrained back projection reconstruction.

    abstract:PURPOSE:To improve quantification of myocardial blood flow using a fast T1 mapping technique using highly constrained back projection reconstruction (HYPR)-accelerated acquisition. METHODS:A major source of error in the measurement of myocardial blood flow (MBF) using MRI is the nonlinear relationship between image si...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24958

    authors: Chen D,Sharif B,Dharmakumar R,Thomson LE,Bairey Merz CN,Berman DS,Li D

    更新日期:2014-09-01 00:00:00

  • Lung imaging under free-breathing conditions.

    abstract::Respiratory motion and pulsatile blood flow can generate artifacts in morphological and functional lung imaging. Total acquisition time, and thus the achievable signal to noise ratio, is limited when performing breath-hold and/or electrocardiogram-triggered imaging. To overcome these limitations, imaging during free r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21846

    authors: Oechsner M,Pracht ED,Staeb D,Arnold JF,Köstler H,Hahn D,Beer M,Jakob PM

    更新日期:2009-03-01 00:00:00

  • Inferring multiple maxima in intravoxel white matter fiber distribution.

    abstract::A new methodology is introduced that characterizes the intravoxel orientation distribution function (ODF) based on a single-fiber model of the diffusion MRI signal. Using a Bayesian framework the probability of finding a fiber in a specific orientation is obtained. The proposed ODF estimation relies on a cigar-like di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21673

    authors: Canales-Rodríguez EJ,Melie-García L,Iturria-Medina Y,Martínez-Montes E,Alemán-Gómez Y,Lin CP

    更新日期:2008-09-01 00:00:00

  • Simultaneous spin-echo refocusing.

    abstract::A new approach to spin-echo imaging is presented in which the 180 degrees RF pulse refocuses two or more spin-echoes at different positions in the readout period. When simultaneous echo refocusing (SER) is implemented using multiple 180 degrees pulses, an undesirable mixing of stimulated echoes and primary echoes from...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20587

    authors: Günther M,Feinberg DA

    更新日期:2005-09-01 00:00:00

  • In vivo differentiation of two vessel wall layers in lower extremity peripheral vein bypass grafts: application of high-resolution inner-volume black blood 3D FSE.

    abstract::Lower extremity peripheral vein bypass grafts (LE-PVBG) imaged with high-resolution black blood three-dimensional (3D) inner-volume (IV) fast spin echo (FSE) MRI at 1.5 Tesla possess a two-layer appearance in T1W images while only the inner layer appears visible in the corresponding T2W images. This study quantifies t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22037

    authors: Mitsouras D,Owens CD,Conte MS,Ersoy H,Creager MA,Rybicki FJ,Mulkern RV

    更新日期:2009-09-01 00:00:00

  • Sensitivity regularization of the Cramér-Rao lower bound to minimize B1 nonuniformity effects in quantitative magnetization transfer imaging.

    abstract:PURPOSE:To develop and validate a regularization approach of optimizing B1 insensitivity of the quantitative magnetization transfer (qMT) pool-size ratio (F). METHODS:An expression describing the impact of B1 inaccuracies on qMT fitting parameters was derived using a sensitivity analysis. To simultaneously optimize fo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27337

    authors: Boudreau M,Pike GB

    更新日期:2018-12-01 00:00:00

  • India ink: a potential clinically applicable EPR oximetry probe.

    abstract::Using a material that already is in widespread use in humans, India ink, the first EPR measurements in a human have been made, using the India ink in a pre-existing tattoo. The EPR spectra of India ink are very sensitive to the partial pressure of oxygen (pO2), thereby making it feasible to use this approach to measur...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310218

    authors: Swartz HM,Liu KJ,Goda F,Walczak T

    更新日期:1994-02-01 00:00:00

  • Real-time measurements of cellular oxygen consumption, pH, and energy metabolism using nuclear magnetic resonance spectroscopy.

    abstract::Changes in molecular expression or apoptotic behavior, induced by malignant transformation or anticancer treatment, are frequently reflected in cellular metabolism and oxygen consumption. A technique to monitor oxygen consumption, cell physiology, and metabolism noninvasively would provide a better understanding of in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1102

    authors: Pilatus U,Aboagye E,Artemov D,Mori N,Ackerstaff E,Bhujwalla ZM

    更新日期:2001-05-01 00:00:00