Quantitative framework for prospective motion correction evaluation.

Abstract:

PURPOSE:Establishing a framework to evaluate performances of prospective motion correction (PMC) MRI considering motion variability between MRI scans. METHODS:A framework was developed to obtain quantitative comparisons between different motion correction setups, considering that varying intrinsic motion patterns between acquisitions can induce bias. Intrinsic motion was considered by replaying in a phantom experiment the recorded motion trajectories from subjects. T1-weighted MRI on five volunteers and two different marker fixations (mouth guard and nose bridge fixations) were used to test the framework. Two metrics were investigated to quantify the improvement of the image quality with PMC. RESULTS:Motion patterns vary between subjects as well as between repeated scans within a subject. This variability can be approximated by replaying the motion in a distinct phantom experiment and used as a covariate in models comparing motion corrections. We show that considering the intrinsic motion alters the statistical significance in comparing marker fixations. As an example, two marker fixations, a mouth guard and a nose bridge, were evaluated in terms of their effectiveness for PMC. A mouth guard achieved better PMC performance. CONCLUSION:Intrinsic motion patterns can bias comparisons between PMC configurations and must be considered for robust evaluations. A framework for evaluating intrinsic motion patterns in PMC is presented.

journal_name

Magn Reson Med

authors

Pannetier NA,Stavrinos T,Ng P,Herbst M,Zaitsev M,Young K,Matson G,Schuff N

doi

10.1002/mrm.25580

subject

Has Abstract

pub_date

2016-02-01 00:00:00

pages

810-6

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

75

pub_type

杂志文章
  • Fast anatomical imaging of the heart and assessment of myocardial perfusion with arrhythmia insensitive magnetization preparation.

    abstract::A new contrast preparation based on modified driven equilibrium Fourier transfer is introduced and evaluated for generation of T1-weighted images for assessment of the myocardial perfusion with contrast agent first-pass kinetics. The new preparation scheme produces T1 contrast with insensitivity to arrhythmias in pros...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340408

    authors: Tsekos NV,Zhang Y,Merkle H,Wilke N,Jerosch-Herold M,Stillman A,Uğurbil K

    更新日期:1995-10-01 00:00:00

  • Off-resonance-dependent slice profile effects in balanced steady-state free precession imaging.

    abstract::The purpose of this study was the simulation and measurement of balanced steady-state free precession (bSSFP) slice profiles for a detailed analysis of the influence of off-resonance effects on slice profile shape and bSSFP signal intensity. Due to the frequency response function of the bSSFP sequence, measurements th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21557

    authors: Staehle F,Leupold J,Hennig J,Markl M

    更新日期:2008-05-01 00:00:00

  • Pharmacological MRI of the choroid and retina: blood flow and BOLD responses during nitroprusside infusion.

    abstract::Nitroprusside, a vasodilatory nitric oxide donor, is clinically used during vascular surgery and to lower blood pressure in acute hypertension. This article reports a novel application of blood flow (BF) and blood oxygenation level dependent (BOLD) MRI on an 11.7T scanner to image the rat chorioretinal BF and BOLD cha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24112

    authors: Shih YY,Li G,Muir ER,De La Garza BH,Kiel JW,Duong TQ

    更新日期:2012-10-01 00:00:00

  • Phase-contrast velocimetry with simultaneous fat/water separation.

    abstract::Phase-contrast MRI can provide high-resolution angiographic velocity images, especially in conjunction with non-Cartesian k-space sampling. However, acquisitions can be sensitive to errors from artifacts from main magnetic field inhomogeneities and chemical shift from fat. Particularly in body imaging, fat content can...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22355

    authors: Johnson KM,Wieben O,Samsonov AA

    更新日期:2010-06-01 00:00:00

  • Simulations of high permittivity materials for 7 T neuroimaging and evaluation of a new barium titanate-based dielectric.

    abstract::High permittivity "dielectric pads" have been shown to increase image quality at high magnetic fields in regions of low radiofrequency transmit efficiency. This article presents a series of electromagnetic simulations to determine the effects of pad size and geometry, relative permittivity value, as well as thickness ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24176

    authors: Teeuwisse WM,Brink WM,Haines KN,Webb AG

    更新日期:2012-04-01 00:00:00

  • Perfusion MRI of U87 brain tumors in a mouse model.

    abstract::Continuous arterial spin labeling (CASL) was used to obtain an index of cerebral blood flow (ICBF) in the normal mouse brain and in an orthotopic mouse model of human U87 high-grade glioma at 8.5 T. Under the assumption of a constant tissue:blood partition coefficient for water in different tissues, the mean ICBF (n =...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20029

    authors: Sun Y,Schmidt NO,Schmidt K,Doshi S,Rubin JB,Mulkern RV,Carroll R,Ziu M,Erkmen K,Poussaint TY,Black P,Albert M,Burstein D,Kieran MW

    更新日期:2004-05-01 00:00:00

  • A highly sensitive lactate editing technique for surface coil spectroscopic imaging in vivo.

    abstract::A lactate editing sequence based on the use of spin-locking pulses with surface coils is described. The sequence retains more than 90% of the available lactate magnetization and suppresses at least 95% of the lipid signal in a single scan and ca. 99.5% after a simple two step cycle. The technique allows simultaneous o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290320

    authors: Bourgeois D,Kozlowski P

    更新日期:1993-03-01 00:00:00

  • Direct saturation-corrected chemical exchange saturation transfer MRI of glioma: Simplified decoupling of amide proton transfer and nuclear overhauser effect contrasts.

    abstract:PURPOSE:Chemical exchange saturation transfer (CEST) MRI has shown promise in tissue characterization in diseases like stroke and tumor. However, in vivo CEST imaging such as amide proton transfer (APT) MRI is challenging because of concomitant factors such as direct water saturation, macromolecular magnetization trans...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26959

    authors: Yuwen Zhou I,Wang E,Cheung JS,Lu D,Ji Y,Zhang X,Fulci G,Sun PZ

    更新日期:2017-12-01 00:00:00

  • Magnetic resonance imaging of blood vessels at high fields: in vivo and in vitro measurements and image simulation.

    abstract::Unusually high image contrast in vivo magnetic resonance imaging of the brain becomes observable at high magnetic fields when the blood oxygenation level is lowered. The cause of the contrast has been attributed to a magnetic susceptibility effect induced by paramagnetic deoxyhemoglobin in red cells. When the cylinder...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910160103

    authors: Ogawa S,Lee TM

    更新日期:1990-10-01 00:00:00

  • Abnormal brain anatomical topological organization of the cognitive-emotional and the frontoparietal circuitry in major depressive disorder.

    abstract:PURPOSE:Despite the increasing understanding of major depressive disorder (MDD) using neuroimaging techniques, the topological organization of anatomical networks underlying MDD remains unclear. METHODS:The topological organization of brain anatomical networks was explored using complex network approaches. Diffusion t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25036

    authors: Qin J,Wei M,Liu H,Yan R,Luo G,Yao Z,Lu Q

    更新日期:2014-11-01 00:00:00

  • Combined dynamic contrast-enhanced liver MRI and MRA using interleaved variable density sampling.

    abstract:PURPOSE:To develop and evaluate a method for volumetric contrast-enhanced MRI of the liver, with high spatial and temporal resolutions, for combined dynamic imaging and MR angiography (MRA) using a single injection of contrast agent. METHODS:An interleaved variable density (IVD) undersampling pattern was implemented i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25195

    authors: Salmani Rahimi M,Korosec FR,Wang K,Holmes JH,Motosugi U,Bannas P,Reeder SB

    更新日期:2015-03-01 00:00:00

  • Fe(III) distribution varies substantially within and between atherosclerotic plaques.

    abstract:PURPOSE:Vulnerable atherosclerotic plaques are structurally weak and prone to rupture, presumably due to local oxidative stress. Redox active iron is linked to oxidative stress and the aim of this study was to investigate the distribution of Fe(III) in carotid plaques and its relation to vulnerability for rupture. MET...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24687

    authors: Gustafsson H,Hallbeck M,Norell M,Lindgren M,Engström M,Rosén A,Zachrisson H

    更新日期:2014-02-01 00:00:00

  • Graphical programming interface: A development environment for MRI methods.

    abstract:PURPOSE:To introduce a multiplatform, Python language-based, development environment called graphical programming interface for prototyping MRI techniques. METHODS:The interface allows developers to interact with their scientific algorithm prototypes visually in an event-driven environment making tasks such as paramet...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25528

    authors: Zwart NR,Pipe JG

    更新日期:2015-11-01 00:00:00

  • Quantifying the intra- and extravascular contributions to spin-echo fMRI at 3 T.

    abstract::Functional MRI (fMRI) by means of spin-echo (SE) techniques provides an interesting alternative to gradient-echo methods because the contrast is based primarily on dynamic averaging associated with the blood oxygenation level-dependent (BOLD) effect. In this article the contributions from different brain compartments ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20221

    authors: Jochimsen TH,Norris DG,Mildner T,Möller HE

    更新日期:2004-10-01 00:00:00

  • Free-breathing volumetric fat/water separation by combining radial sampling, compressed sensing, and parallel imaging.

    abstract:PURPOSE:Conventional fat/water separation techniques require that patients hold breath during abdominal acquisitions, which often fails and limits the achievable spatial resolution and anatomic coverage. This work presents a novel approach for free-breathing volumetric fat/water separation. METHODS:Multiecho data are ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26392

    authors: Benkert T,Feng L,Sodickson DK,Chandarana H,Block KT

    更新日期:2017-08-01 00:00:00

  • Gradient characterization using a Fourier-transform technique.

    abstract::This paper describes a technique for characterizing the gradient subsystem of a magnetic resonance (MR) system. The technique uses a Fourier-transform analysis to directly measure the k-space trajectory produced by an arbitrary gradient waveform. In addition, the method can be easily extended to multiple dimensions an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390411

    authors: Alley MT,Glover GH,Pelc NJ

    更新日期:1998-04-01 00:00:00

  • Stability assessment of gadolinium complexes by P-31 and H-1 relaxometry.

    abstract::Longitudinal P-31 relaxation rate enhancements of phosphate groups have been measured at pH 7-7.2 and 310 degrees K on aqueous solutions containing adenosine triphosphate (ATP), phosphocreatine (PCr), inorganic phosphate (Pi) and some lanthanide complexes (Gd-DOTA, Gd-HPDO3A, Gd-DO3A, Gd-DTPA, Gd-DTPA-BMA). The macroc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310413

    authors: Vander Elst L,Van Haverbeke Y,Goudemant JF,Muller RN

    更新日期:1994-04-01 00:00:00

  • Cardiac real-time imaging using SENSE. SENSitivity Encoding scheme.

    abstract::Sensitivity encoding is used to improve the performance of real-time MRI. The encoding efficiency of single-shot and segmented echo-planar imaging is tripled by means of a 6-element receiver coil array. The feasibility of this approach is verified for double oblique cardiac real-time imaging of human subjects at rest ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200002)43:2<177::aid-mrm3>

    authors: Weiger M,Pruessmann KP,Boesiger P

    更新日期:2000-02-01 00:00:00

  • Fetal whole-heart 4D imaging using motion-corrected multi-planar real-time MRI.

    abstract:PURPOSE:To develop an MRI acquisition and reconstruction framework for volumetric cine visualization of the fetal heart and great vessels in the presence of maternal and fetal motion. METHODS:Four-dimensional (4D) depiction was achieved using a highly-accelerated multi-planar real-time balanced steady-state free prece...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27798

    authors: van Amerom JFP,Lloyd DFA,Deprez M,Price AN,Malik SJ,Pushparajah K,van Poppel MPM,Rutherford MA,Razavi R,Hajnal JV

    更新日期:2019-09-01 00:00:00

  • Application of image registration to measurement of intervertebral rotation in the lumbar spine.

    abstract::In this study, the precision and accuracy of a new method for measuring axial rotations of the lumbar vertebrae, which are thought to be increased in patients with degenerative spinal instability, were estimated. A standard image registration algorithm involving a user-selected center of rotation was adapted for this ...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.10319

    authors: Rogers BP,Haughton VM,Arfanakis K,Meyerand ME

    更新日期:2002-12-01 00:00:00

  • Model of the human vasculature for studying the influence of contrast injection speed on cerebral perfusion MRI.

    abstract::Simulations of dynamic susceptibility contrast (DSC) MRI are frequently performed by assuming a certain shape for the input function and the microvascular response function. However, to investigate the influence of parameters that will affect the shape of the input function, a more complex model of the human vasculatu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10567

    authors: van Osch MJ,Vonken EJ,Wu O,Viergever MA,van der Grond J,Bakker CJ

    更新日期:2003-09-01 00:00:00

  • Selective excitation of two-dimensional arbitrarily shaped voxels with parallel excitation in spectroscopy.

    abstract::Parallel excitation is being studied intensively for applications in MR imaging and in particular for selecting arbitrary shapes as regions of interest. In this work, parallel excitation was applied to arbitrarily shaped voxel selection in spectroscopy and investigated for different excitation k-space trajectories (ra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23018

    authors: Snyder J,Haas M,Hennig J,Zaitsev M

    更新日期:2012-02-01 00:00:00

  • Inverse reconstruction method for segmented multishot diffusion-weighted MRI with multiple coils.

    abstract::Each k-space segment in multishot diffusion-weighted MRI is affected by a different spatially varying phase which is caused by unavoidable motions and amplified by the diffusion-encoding gradients. A proper image reconstruction therefore requires phase maps for each segment. Such maps are commonly derived from two-dim...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22126

    authors: Uecker M,Karaus A,Frahm J

    更新日期:2009-11-01 00:00:00

  • Continuous assessment of relative cerebral blood volume in transient ischemia using steady state susceptibility-contrast MRI.

    abstract::The utility of a noninvasive steady state susceptibility-contrast MRI technique for continuous measurement of relative cerebral blood volume (rCBV) during global transient ischemia and subsequent hyperemia in a feline ischemia model is demonstrated. The measurements were obtained during a 10-min period of occlusion an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350207

    authors: Hamberg LM,Boccalini P,Stranjalis G,Hunter GJ,Huang Z,Halpern E,Weisskoff RM,Moskowitz MA,Rosen BR

    更新日期:1996-02-01 00:00:00

  • Measurement of fibrin concentration by fast field-cycling NMR.

    abstract::The relaxation of (1)H nuclei due to their interaction with quadrupolar (14)N nuclei in gel structures is measured using fast field-cycling NMR. This phenomenon called quadrupolar dips has been reported in different (1)H-(14)N bond-rich species. In this study, we have studied quadrupolar dips in fibrin, an insoluble p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23117

    authors: Broche LM,Ismail SR,Booth NA,Lurie DJ

    更新日期:2012-05-01 00:00:00

  • SPIRiT: Iterative self-consistent parallel imaging reconstruction from arbitrary k-space.

    abstract::A new approach to autocalibrating, coil-by-coil parallel imaging reconstruction, is presented. It is a generalized reconstruction framework based on self-consistency. The reconstruction problem is formulated as an optimization that yields the most consistent solution with the calibration and acquisition data. The appr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22428

    authors: Lustig M,Pauly JM

    更新日期:2010-08-01 00:00:00

  • Development and validation of 3D MP-SSFP to enable MRI in inhomogeneous magnetic fields.

    abstract:PURPOSE:We demonstrate the feasibility of MRI with missing-pulse steady-state free precession (MP-SSFP) in a 4T magnet with artificially degraded homogeneity. METHODS:T1 , T2 , and diffusion contrast of MP-SSFP was simulated with constant and alternate radiofrequency (RF) phase using an extended phase graph. To valida...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28469

    authors: Kobayashi N,Parkinson B,Idiyatullin D,Adriany G,Theilenberg S,Juchem C,Garwood M

    更新日期:2021-02-01 00:00:00

  • Intersubject specific absorption rate variability analysis through construction of 23 realistic body models for prostate imaging at 7T.

    abstract:PURPOSE:For ultrahigh field (UHF) MRI, the expected local specific absorption rate (SAR) distribution is usually calculated by numerical simulations using a limited number of generic body models and adding a safety margin to take into account intersubject variability. Assessment of this variability with a large model d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27518

    authors: Meliadò EF,van den Berg CAT,Luijten PR,Raaijmakers AJE

    更新日期:2019-03-01 00:00:00

  • Hybrid ultrasound-MR guided HIFU treatment method with 3D motion compensation.

    abstract:PURPOSE:Treatments using high-intensity focused ultrasound (HIFU) in the abdominal region remain challenging as a result of respiratory organ motion. A novel method is described here to achieve 3D motion-compensated ultrasound (US) MR-guided HIFU therapy using simultaneous ultrasound and MRI. METHODS:A truly hybrid US...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26897

    authors: Celicanin Z,Manasseh G,Petrusca L,Scheffler K,Auboiroux V,Crowe LA,Hyacinthe JN,Natsuaki Y,Santini F,Becker CD,Terraz S,Bieri O,Salomir R

    更新日期:2018-05-01 00:00:00

  • Accelerated three-dimensional multispectral MRI with robust principal component analysis for separation of on- and off-resonance signals.

    abstract:PURPOSE:To enable highly accelerated distortion-free MRI near metal by separating on- and off-resonance to exploit the redundancy of slice-phase encoding for the dominant on-resonance component. METHODS:Multispectral MRI techniques resolve off-resonance distortions by a combination of limited excitation bins and addit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26819

    authors: Levine E,Stevens K,Beaulieu C,Hargreaves B

    更新日期:2018-03-01 00:00:00