Abstract:
PURPOSE:To demonstrate how triple diffusion encoding (TDE) MRI can be applied to separately estimate the intra-axonal and extra-axonal diffusion tensors in white matter (WM). METHODS:Using a TDE pulse sequence with an axially symmetric b-matrix, diffusion MRI data were acquired at 3T for 3 healthy adults with an axial b-value of 4000 s/mm2 , a radial b-value of 307 s/mm2 , and 64 diffusion encoding directions. This acquisition was then repeated with the radial b-value set to 0. A previously proposed theory was applied to these data in order to estimate the intra-axonal diffusivity and axonal water fraction for each WM voxel. Conventional single diffusion encoding data were also obtained with b-values of 1000 and 2000 s/mm2 , which provided additional information sufficient for determining both the intra-axonal and extra-axonal diffusion tensors. RESULTS:From the TDE data, the average intra-axonal diffusivity in WM was found to be 2.24 ± 0.18 µm2 /ms, and the average axonal water fraction was found to be 0.60 ± 0.11. From the 2 diffusion tensors, average WM values were estimated for several compartment-specific diffusion parameters. In particular, the extra-axonal mean diffusivity was 1.09 ± 0.19 µm2 /ms, the intra-axonal fractional anisotropy was 0.50 ± 0.14, and the extra-axonal fractional anisotropy was 0.23 ± 0.13. CONCLUSION:By using a simple TDE pulse sequence with an axially symmetric b-matrix, the diffusion tensors for the intra-axonal and extra-axonal spaces can be separately estimated in adult WM. This allows one to determine compartment-specific diffusion properties for these 2 water pools.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Ramanna S,Moss HG,McKinnon ET,Yacoub E,Helpern JA,Jensen JHdoi
10.1002/mrm.28084subject
Has Abstractpub_date
2020-06-01 00:00:00pages
2209-2220issue
6eissn
0740-3194issn
1522-2594journal_volume
83pub_type
杂志文章abstract::Multiple-slice perfusion imaging by continuous arterial spin labeling (CASL) is made possible by amplitude modulation (AM) of the labeling RF pulse, but perfusion sensitivity is reduced relative to the single-slice technique. A computer model of the Bloch equations for velocity driven adiabatic fast passage was develo...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20604
更新日期:2005-09-01 00:00:00
abstract:PURPOSE:Establishing a framework to evaluate performances of prospective motion correction (PMC) MRI considering motion variability between MRI scans. METHODS:A framework was developed to obtain quantitative comparisons between different motion correction setups, considering that varying intrinsic motion patterns betw...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25580
更新日期:2016-02-01 00:00:00
abstract:PURPOSE:To develop and evaluate a novel dynamic contrast-enhanced imaging technique called RACER-GRASP (Respiratory-weighted, Aortic Contrast Enhancement-guided and coil-unstReaking Golden-angle RAdial Sparse Parallel) MRI that extends GRASP to include automatic contrast bolus timing, respiratory motion compensation, a...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27002
更新日期:2018-07-01 00:00:00
abstract::Magnetization transfer imaging (MT) and localized proton spectroscopy (1H-MRS) were utilized in the evaluation of lesions (high signal abnormalities on T2-weighted images) and normal-appearing white matter (NAWM) in multiple sclerosis (MS). Eleven patients with a clinical diagnosis of MS were independently evaluated w...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910320303
更新日期:1994-09-01 00:00:00
abstract:PURPOSE:MRI-guided thermal ablations require reliable monitoring methods to ensure complete destruction of the diseased tissue while avoiding damage to the surrounding healthy tissue. Based on the fact that thermal ablations result in substantial changes in biomechanical properties, interventional MR elastography (MRE)...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25694
更新日期:2016-03-01 00:00:00
abstract::The complexity of biologic tissues, with multiple compartments each with its own diffusion and relaxation properties, requires complex formalisms to model water signal in most magnetic resonance imaging or magnetic resonance spectroscopy experiments. In this article, we describe a magnetic susceptibility-induced shift...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20565
更新日期:2005-07-01 00:00:00
abstract::Recovery of the cerebral cortex after 10 min of cardiac arrest was studied in rat using noninvasive MRI techniques. The apparent diffusion coefficient (ADC) of brain water was imaged to document reversal of the metabolic impairment. Perfusion-weighted imaging and blood oxygen level dependent (BOLD) imaging were perfor...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910390516
更新日期:1998-05-01 00:00:00
abstract:PURPOSE:Spectrally selective "prewinding" radiofrequency pulses can counteract B0 inhomogeneity in steady-state sequences, but can only prephase a limited range of off-resonance. We propose spectral-spatial small-tip angle prewinding pulses that increase the off-resonance bandwidth that can be successfully prephased by...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26794
更新日期:2018-03-01 00:00:00
abstract:PURPOSE:The feasibility of imaging musculoskeletal fibrous tissue components, such as menisci, ligaments, and tendons, with a conventional spoiled gradient echo technique is explored in vivo at 3 T and 7 T. METHODS:To this end, the echo time (TE1 ) of a conventional Fourier-encoded multicontrast three-dimensional SGPR...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24578
更新日期:2013-11-01 00:00:00
abstract::One-dimensional spectroscopic imaging of (13)C-4-glutamate turnover is performed in the human brain with a 6 cc nominal voxel resolution at 4T. Data were acquired with an indirect detection approach using a short spin echo single quantum (1)H-(13)C heteronuclear editing method and a 7 cm surface coil with quadrature (...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/1522-2594(200011)44:5<673::aid-mrm3>3.0.co
更新日期:2000-11-01 00:00:00
abstract::MRI evaluations of intramyocardial hemorrhage in acute infarction have relied on T(2) and T(2)(*) shortening only. We propose a more comprehensive evaluation of hemorrhagic infarction based on the concept that fluctuations in T(2) and T(1) relaxation in acute reperfused infarction will reflect transient edema and hemo...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21079
更新日期:2006-12-01 00:00:00
abstract::Recent in vivo 1H MRS studies of muscle oxygen levels by means of myoglobin (Mb) oxygenation have necessitated an investigation of the possible contamination from deoxy-hemoglobin (Hb). To determine the contribution of Hb in these NMR measurements, we studied the NMR visibility of histidyl N-delta proton of Hb in lyse...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910300616
更新日期:1993-12-01 00:00:00
abstract:PURPOSE:Quantitative susceptibility map (QSM) reconstruction is ill posed due to the zero values on the "magic angle cone" that make the maps prone to streaking artifacts. We propose projection onto convex sets (POCS) in the method of steepest descent (SD) for QSM reconstruction. METHODS:Two convex projections, an obj...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25155
更新日期:2015-02-01 00:00:00
abstract::In guinea pigs immunized with myelin basic protein (MBP) in complete Freund's adjuvant, experimental allergic encephalomyelitis (EAE) shows a characteristic clinical and pathological course. This study characterized the proton nuclear magnetic resonance (NMR) properties of the central nervous system prior to the onset...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910050203
更新日期:1987-08-01 00:00:00
abstract:PURPOSE:To investigate the effect of realistic microstructural geometry on the susceptibility-weighted MR signal in white matter (WM), with application to demyelination. METHODS:Previous work has modeled susceptibility-weighted signals under the assumption that axons are cylindrical. In this study, we explored the imp...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26689
更新日期:2018-01-01 00:00:00
abstract:PURPOSE:To analyze the effect of B0 field drift on multivoxel MR spectroscopic imaging and to propose an approach for its correction. THEORY AND METHODS:It is shown, both theoretically and in a phantom, that for ∼30 min acquisitions a linear B0 drift (∼0.1 ppm/h) will cause localization errors that can reach several v...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24536
更新日期:2013-10-01 00:00:00
abstract::In this work a model-free arterial spin labeling (ASL) quantification approach for measuring cerebral blood flow (CBF) and arterial blood volume (aBV) is proposed. The method is based on the acquisition of a train of multiple images following the labeling scheme. Perfusion is obtained using deconvolution in a manner s...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20784
更新日期:2006-02-01 00:00:00
abstract::To investigate the dependency of T(1) relaxation on mechanical strain in articular cartilage, quantitative magnetic resonance T(1) imaging experiments were carried out on cartilage before/after the tissue was immersed in gadolinium contrast agent and when the tissue was being compressed (up to ∼ 48% strains). The spat...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22933
更新日期:2011-06-01 00:00:00
abstract::Imaging of stable paramagnetic spin probes in phantom objects and in vivo was evaluated using a RF time domain EPR spectrometer/imager operating at 300 MHz. Projections were collected using static magnetic field gradients and images were reconstructed using filtered back-projection techniques. Results from phantom obj...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(200003)43:3<375::aid-mrm9>
更新日期:2000-03-01 00:00:00
abstract::Localized 1H NMR homonuclear J editing spectroscopy was used to measure the concentration of 2-pyrrolidinone (PRDN) in the human occipital lobe of five normal and six epileptic subjects taking vigabatrin. PRDN is a lactam cyclization product of gamma-aminobutyric acid (GABA). From a localized volume of 13.5 cm3 in the...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199905)41:5<889::aid-mrm6>
更新日期:1999-05-01 00:00:00
abstract::Imaging delayed hyperenhancement of myocardial infarction is most commonly performed using an inversion recovery (IR) prepared 2D breathhold segmented k-space gradient echo (FGRE) sequence. Since only one slice is acquired per breathhold in this technique, 12-16 successive breathholds are required for complete anatomi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20061
更新日期:2004-05-01 00:00:00
abstract:PURPOSE:Going to ultrahigh field MRI (e.g., 7 Tesla [T]), the nonuniformity of the B1+ field and the increased radiofrequency (RF) power deposition become challenging. While surface coils improve the power efficiency in B1+, its field remains nonuniform. In this work, an RF pulse was designed that uses the slab selecti...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25415
更新日期:2015-08-01 00:00:00
abstract::This work presents a method applied to the design of short self-shielded gradient coils of cylindrical geometry. The method uses a hybrid technique that combines the simulated annealing and target field methods to optimize the standard stream functions. The optimized stream functions were parameterized using a few deg...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/1522-2594(200103)45:3<505::aid-mrm1066>3.0
更新日期:2001-03-01 00:00:00
abstract::The feasibility of MR subtraction imaging of lung ventilation using air against oxygen using a multiple inversion recovery half-Fourier single-shot turbo spin echo (MIR-HASTE) sequence was investigated. Eight healthy, nonsmoking volunteers (3 males, 5 females; from 27 to 48 years of age) were studied on a 1.5 T MR uni...
journal_title:Magnetic resonance in medicine
pub_type: 临床试验,杂志文章
doi:10.1002/1522-2594(200006)43:6<913::aid-mrm21>3.0.c
更新日期:2000-06-01 00:00:00
abstract:PURPOSE:To present a time-efficient technique for banding reduction in balanced steady-state free precession (bSSFP) imaging using phase-cycled simultaneous multislice (SMS) acquisition with CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration). THEORY:The proposed technique exploits the ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26076
更新日期:2016-12-01 00:00:00
abstract::Phosphorus-31 nuclear magnetic resonance spectroscopy (31P NMR) was used to assess the temporal changes of high-energy phosphate metabolites in the region of acute myocardial ischemia of open-chest cats. Eight anesthetized cats were studied following ligation of the left anterior descending coronary artery. Creatine p...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910030209
更新日期:1986-04-01 00:00:00
abstract::Chemically-fixed nervous tissues are well-suited for high-resolution, time-intensive MRI acquisitions without motion artifacts, such as those required for brain atlas projects, but the aldehyde fixatives used may significantly alter tissue MRI properties. To test this hypothesis, this study characterized the impact of...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21977
更新日期:2009-07-01 00:00:00
abstract::A new method for efficiently processing MRS data acquired with phased-array coils is presented. The method consists of performing phase compensation (i.e., redefining the signal phase relative to a common reference) of the signals in the time domain prior to combining the signals. The resulting spectra are equivalent ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20244
更新日期:2004-11-01 00:00:00
abstract::Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final image. A simple Monte Carlo based method is proposed for all linear image reconstruction algorithms, which allows measurement of signal-to-noise r...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21728
更新日期:2008-10-01 00:00:00
abstract::We studied the fluxes of a potassium congener (Rb(+)) in mouse hearts by (87)Rb MRS at 8.4T. The hearts were loaded with Rb(+) by perfusion with Krebs-Henseleit buffer, in which 50% of K(+) was substituted with Rb(+). We initiated Rb(+) efflux by changing the perfusion medium to Rb(+)-free buffer. Spectra were acquire...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20450
更新日期:2005-05-01 00:00:00