In vivo measurement of volumetric strain in the human brain induced by arterial pulsation and harmonic waves.

Abstract:

:Motion-sensitive phase contrast magnetic resonance imaging and magnetic resonance elastography are applied for the measurement of volumetric strain and tissue compressibility in human brain. Volumetric strain calculated by the divergence operator using a biphasic effective-medium model is related to dilatation and compression of fluid spaces during harmonic stimulation of the head or during intracranial passage of the arterial pulse wave. In six volunteers, phase contrast magnetic resonance imaging showed that the central cerebrum expands at arterial pulse wave to strain values of (2.8 ± 1.9)·10(-4). The evolution of volumetric strain agrees well with the magnitude of the harmonic divergence measured in eight volunteers by magnetic resonance elastography using external activation of 25 Hz vibration frequency. Intracranial volumetric strain was proven sensitive to venous pressure altered by abdominal muscle contraction. In eight volunteers, an increase in volumetric strain due to abdominal muscle contraction of approximately 45% was observed (P = 0.0001). The corresponding compression modulus in the range of 9.5-13.5 kPa demonstrated that the compressibility of brain tissue at 25 Hz stimulation is much higher than that of water. This pilot study provides the background for compression-sensitive magnetic resonance imaging with or without external head stimulation. Volumetric strain may be sensitive to fluid flow abnormalities or pressure imbalances between vasculature and parenchyma as seen in hydrocephalus.

journal_name

Magn Reson Med

authors

Hirsch S,Klatt D,Freimann F,Scheel M,Braun J,Sack I

doi

10.1002/mrm.24499

subject

Has Abstract

pub_date

2013-09-01 00:00:00

pages

671-83

issue

3

eissn

0740-3194

issn

1522-2594

journal_volume

70

pub_type

杂志文章
  • Intersubject specific absorption rate variability analysis through construction of 23 realistic body models for prostate imaging at 7T.

    abstract:PURPOSE:For ultrahigh field (UHF) MRI, the expected local specific absorption rate (SAR) distribution is usually calculated by numerical simulations using a limited number of generic body models and adding a safety margin to take into account intersubject variability. Assessment of this variability with a large model d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27518

    authors: Meliadò EF,van den Berg CAT,Luijten PR,Raaijmakers AJE

    更新日期:2019-03-01 00:00:00

  • Real-time interactive MRI-guided cardiac surgery: aortic valve replacement using a direct apical approach.

    abstract::Minimally invasive cardiac surgery requires arresting and emptying of the heart, which compromises visualization of the surgical field. In this feasibility study a novel surgical procedure is demonstrated in which real-time MRI is used to guide the placement of a prosthetic aortic valve in the beating heart via direct...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21044

    authors: McVeigh ER,Guttman MA,Lederman RJ,Li M,Kocaturk O,Hunt T,Kozlov S,Horvath KA

    更新日期:2006-11-01 00:00:00

  • In vivo time course studies of the tissue responses to resorbable polylactic acid implants by means of MRI.

    abstract::Magnetic resonance (MR) imaging and relaxation time measurements of bioresorbable implants made of polylactic acid (PLA), as well as the surrounding tissues, were carried out over a period of 6 months to monitor the implant state and the body's responses, and to determine how these processes are reflected in MR data. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199907)42:1<210::aid-mrm29

    authors: Stroman PW,Dorvil JC,Marois Y,Poddevin N,Guidoin R

    更新日期:1999-07-01 00:00:00

  • High-frequency subband compressed sensing MRI using quadruplet sampling.

    abstract:PURPOSE:To present and validate a new method that formalizes a direct link between k-space and wavelet domains to apply separate undersampling and reconstruction for high- and low-spatial-frequency k-space data. THEORY AND METHODS:High- and low-spatial-frequency regions are defined in k-space based on the separation o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24592

    authors: Sung K,Hargreaves BA

    更新日期:2013-11-01 00:00:00

  • Investigating the BOLD effect during infusion of Gd-DTPA using rapid T2* mapping.

    abstract::This work aimed to investigate the effects of administering Gd-DTPA on the BOLD effect, and to determine the feasibility of using this approach to measure fractional changes in blood volume and blood oxygenation on neuronal activation during a visual paradigm. A linear relationship between cortical R(2)(*) and the int...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10340

    authors: Pears JA,Francis ST,Butterworth SE,Bowtell RW,Gowland PA

    更新日期:2003-01-01 00:00:00

  • Cooperative T1 and T2 effects on contrast using a new driven inversion spin-echo (DISE) MRI pulse sequence.

    abstract::A pulse sequence is presented for obtaining a single image with combined T1/T2 weighting. T2 relaxation is made to increase intensity, in cooperation with the effect of T1 relaxation, by providing T2 weighting with a 90 degrees-180 degrees-90 degrees driven inversion pulse triplet in an inversion recovery method. Unli...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910150307

    authors: Conturo TE,Kessler RM,Beth AH

    更新日期:1990-09-01 00:00:00

  • Diffusion dispersion imaging: Mapping oscillating gradient spin-echo frequency dependence in the human brain.

    abstract:PURPOSE:Oscillating gradient spin-echo (OGSE) diffusion MRI provides information about the microstructure of biological tissues by means of the frequency dependence of the apparent diffusion coefficient (ADC). ADC dependence on OGSE frequency has been explored in numerous rodent studies, but applications in the human b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28083

    authors: Arbabi A,Kai J,Khan AR,Baron CA

    更新日期:2020-06-01 00:00:00

  • Correction of phase errors in quantitative water-fat imaging using a monopolar time-interleaved multi-echo gradient echo sequence.

    abstract:PURPOSE:To propose a phase error correction scheme for monopolar time-interleaved multi-echo gradient echo water-fat imaging that allows accurate and robust complex-based quantification of the proton density fat fraction (PDFF). METHODS:A three-step phase correction scheme is proposed to address a) a phase term induce...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26485

    authors: Ruschke S,Eggers H,Kooijman H,Diefenbach MN,Baum T,Haase A,Rummeny EJ,Hu HH,Karampinos DC

    更新日期:2017-09-01 00:00:00

  • Myocardial effective transverse relaxation time T2* Correlates with left ventricular wall thickness: A 7.0 T MRI study.

    abstract:PURPOSE:Myocardial effective relaxation time T2* is commonly regarded as a surrogate for myocardial tissue oxygenation. However, it is legitimate to assume that there are multiple factors that influence T2*. To this end, this study investigates the relationship between T2* and cardiac macromorphology given by left vent...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26312

    authors: Huelnhagen T,Hezel F,Serradas Duarte T,Pohlmann A,Oezerdem C,Flemming B,Seeliger E,Prothmann M,Schulz-Menger J,Niendorf T

    更新日期:2017-06-01 00:00:00

  • T2-prepared SSFP improves diagnostic confidence in edema imaging in acute myocardial infarction compared to turbo spin echo.

    abstract::T2-weighted MRI of edema in acute myocardial infarction (MI) provides a means of differentiating acute and chronic MI, and assessing the area at risk of infarction. Conventional T2-weighted imaging of edema uses a turbo spin-echo (TSE) readout with dark-blood preparation. Clinical applications of dark-blood TSE method...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21215

    authors: Kellman P,Aletras AH,Mancini C,McVeigh ER,Arai AE

    更新日期:2007-05-01 00:00:00

  • Fast oxygen-enhanced multislice imaging of the lung using parallel acquisition techniques.

    abstract::The purpose of this study was to evaluate an optimized multislice acquisition technique for oxygen-enhanced MRI of the lung using slice-selective inversion and refocusing pulses in combination with parallel imaging. An inversion recovery HASTE sequence was implemented with respiratory triggering to perform imaging in ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20495

    authors: Dietrich O,Losert C,Attenberger U,Fasol U,Peller M,Nikolaou K,Reiser MF,Schoenberg SO

    更新日期:2005-06-01 00:00:00

  • Myocardial fat quantification in humans: Evaluation by two-point water-fat imaging and localized proton spectroscopy.

    abstract::Proton MR spectroscopy ((1)H-MRS) has been used for in vivo quantification of intracellular triglycerides within the sarcolemma. The purpose of this study was to assess whether breath-hold dual-echo in- and out-of-phase MRI at 3.0 T can quantify the fat content of the myocardium. Biases, including T(1), T*(2), and noi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22289

    authors: Liu CY,Redheuil A,Ouwerkerk R,Lima JA,Bluemke DA

    更新日期:2010-04-01 00:00:00

  • Assessment of bias in experimentally measured diffusion tensor imaging parameters using SIMEX.

    abstract::Diffusion tensor imaging enables in vivo investigation of tissue cytoarchitecture through parameter contrasts sensitive to water diffusion barriers at the micrometer level. Parameters are derived through an estimation process that is susceptible to noise and artifacts. Estimated parameters (e.g., fractional anisotropy...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24324

    authors: Lauzon CB,Crainiceanu C,Caffo BC,Landman BA

    更新日期:2013-03-01 00:00:00

  • In vivo 13C magnetic resonance spectroscopy of human brain on a clinical 3 T scanner using [2-13C]glucose infusion and low-power stochastic decoupling.

    abstract::This study presents the detection of [2-(13)C]glucose metabolism in the carboxylic/amide region in the human brain, and demonstrates that the cerebral metabolism of [2-(13)C]glucose can be studied in human subjects in the presence of severe hardware constraints of widely available 3 T clinical scanners and with low-po...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22044

    authors: Li S,Zhang Y,Wang S,Yang J,Ferraris Araneta M,Farris A,Johnson C,Fox S,Innis R,Shen J

    更新日期:2009-09-01 00:00:00

  • Bayesian inference of hemodynamic changes in functional arterial spin labeling data.

    abstract::The study of brain function using MRI relies on acquisition techniques that are sensitive to different aspects of the hemodynamic response contiguous to areas of neuronal activity. For this purpose different contrasts such as arterial spin labeling (ASL) and blood oxygenation level dependent (BOLD) functional MRI tech...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21039

    authors: Woolrich MW,Chiarelli P,Gallichan D,Perthen J,Liu TT

    更新日期:2006-10-01 00:00:00

  • Quantitative MRI assessment of leukoencephalopathy.

    abstract::Quantitative MRI assessment of leukoencephalopathy is difficult because the MRI properties of leukoencephalopathy significantly overlap those of normal tissue. This report describes the use of an automated procedure for longitudinal measurement of tissue volume and relaxation times to quantify leukoencephalopathy. Ima...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1002/mrm.10124

    authors: Reddick WE,Glass JO,Langston JW,Helton KJ

    更新日期:2002-05-01 00:00:00

  • Work-related factors associated with occupational exposure to static magnetic stray fields from MRI scanners.

    abstract:PURPOSE:This study aims to identify work-related and personal factors associated with workers' exposure to static magnetic fields (SMF) and motion-induced time-varying magnetic fields (TVMF) from MRI scanners. METHODS:Measurements of personal exposure to SMF and TVMF were performed among MRI staff during 439 work shif...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25720

    authors: Schaap K,Christopher-De Vries Y,Cambron-Goulet É,Kromhout H

    更新日期:2016-05-01 00:00:00

  • Iterative correction of RF envelope distortion with GRATER-measured waveforms.

    abstract:PURPOSE:To develop and evaluate a method for RF envelope correction without extra hardware or synchronization. METHODS:Transmitted RF waveforms are measured through a simple pulse sequence called the gradient reversal approach to evaluate RF (GRATER). The measured RF waveforms are used to compute predistorted RF wavef...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27930

    authors: Landes VL,Nayak KS

    更新日期:2020-01-01 00:00:00

  • A high-field superferric NMR magnet.

    abstract::Strong, extensive magnetic fringe fields are a significant problem with magnetic resonance imaging magnets. This is particularly acute with 4-T, whole-body research magnets. To date this problem has been addressed by restricting an extensive zone around the unshielded magnet or by placing external unsaturated iron shi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290107

    authors: Huson FR,Bryan RN,MacKay WW,Herrick RC,Colvin J,Ford JJ,Pissanetzky S,Plishker GA,Rocha R,Schmidt W

    更新日期:1993-01-01 00:00:00

  • Respiration based steering for high intensity focused ultrasound liver ablation.

    abstract:PURPOSE:Respiratory motion makes hepatic ablation using high intensity focused ultrasound (HIFO) challenging. Previous HIFU liver treatment had required apnea induced during general anesthesia. We describe and test a system that allows treatment of the liver in the presence of breathing motion. METHODS:Mapping a signa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24695

    authors: Holbrook AB,Ghanouni P,Santos JM,Dumoulin C,Medan Y,Pauly KB

    更新日期:2014-02-01 00:00:00

  • Atraumatic quantitation of cerebral perfusion in cats by 19F magnetic resonance imaging.

    abstract::We have noninvasively produced low-resolution, quantitative nuclear magnetic resonance images of cerebral blood flow in 2-ml voxels in eight cats. Typical signal-to-noise of 4 to 1 was obtained in cerebral voxels in 16.5-s epochs. Mean flow during normocapnia (paCO2 = 39 +/- 4 mm Hg) and hypercapnia (paCO2 = 62 +/- 4 ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910280105

    authors: Branch CA,Ewing JR,Helpern JA,Ordidge RJ,Butt S,Welch KM

    更新日期:1992-11-01 00:00:00

  • Removal of phase artifacts from fMRI data using a Stockwell transform filter improves brain activity detection.

    abstract::A novel and automated technique is described for removing fMRI image artifacts resulting from motion outside of the imaging field of view. The technique is based on the Stockwell transform (ST), a mathematical operation that provides the frequency content at each time point within a time-varying signal. Using this tec...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10681

    authors: Goodyear BG,Zhu H,Brown RA,Mitchell JR

    更新日期:2004-01-01 00:00:00

  • One-minute whole-brain magnetization transfer ratio imaging with intrinsic B1-correction.

    abstract:PURPOSE:Magnetization transfer ratio (MTR) histograms are used widely for the assessment of diffuse pathological changes in the brain. For broad clinical application, MTR scans should not only be fast, but confounding factors should also be minimized for high reproducibility. To this end, a 1-minute whole-brain spiral ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28618

    authors: Afshari R,Santini F,Heule R,Meyer CH,Pfeuffer J,Bieri O

    更新日期:2020-12-08 00:00:00

  • The use of band-selectable digital filtering in magnetic resonance image enhancement.

    abstract::Manipulation of the data describing two-dimensional magnetic resonance (MR) images can be used to zoom an image, decrease image noise and artifacts by modeling, or emphasize object edges in the field of view. In this paper, a two-dimensional band-selectable digital filtering (2D-BSDF) technique is detailed. This can b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910090307

    authors: Mitchell DK,Nichols ST,Smith MR,Scott K

    更新日期:1989-03-01 00:00:00

  • Time-dependent effects of hormone-deprivation therapy on prostate metabolism as detected by combined magnetic resonance imaging and 3D magnetic resonance spectroscopic imaging.

    abstract::Combined MRI and 3D spectroscopic imaging (MRI/3D-MRSI) was used to study the metabolic effects of hormone-deprivation therapy in 65 prostate cancer patients, who underwent either short, intermediate, or long-term therapy, compared to 30 untreated control patients. There was a significant time-dependent loss of the pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1159

    authors: Mueller-Lisse UG,Swanson MG,Vigneron DB,Hricak H,Bessette A,Males RG,Wood PJ,Noworolski S,Nelson SJ,Barken I,Carroll PR,Kurhanewicz J

    更新日期:2001-07-01 00:00:00

  • Evidence for enhanced functional activity of cervical cord in relapsing multiple sclerosis.

    abstract::Functional MRI (fMRI) was used to assess proprioceptive-associated cervical cord activity in 24 relapsing multiple sclerosis (MS) patients and 10 controls. Cord and brain conventional and diffusion tensor (DT) MRI were also acquired. fMRI was performed using a block design during a proprioceptive stimulation consistin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21595

    authors: Agosta F,Valsasina P,Rocca MA,Caputo D,Sala S,Judica E,Stroman PW,Filippi M

    更新日期:2008-05-01 00:00:00

  • Water in tendon: orientational analysis of the free induction decay.

    abstract::The orientation dependence of the free induction decay (FID) of 1H NMR water signal in ex vivo bovine digital flexor tendon at the native level of hydration is reported. Residual dipolar coupling due to the overall tissue anisotropy produces a 6:1 change in the signal intensity as an angle between the long axis of a s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20540

    authors: Krasnosselskaia LV,Fullerton GD,Dodd SJ,Cameron IL

    更新日期:2005-08-01 00:00:00

  • Single acquisition electrical property mapping based on relative coil sensitivities: A proof-of-concept demonstration.

    abstract:PURPOSE:All methods presented to date to map both conductivity and permittivity rely on multiple acquisitions to compute quantitatively the magnitude of radiofrequency transmit fields, B1+. In this work, we propose a method to compute both conductivity and permittivity based solely on relative receive coil sensitivitie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25399

    authors: Marques JP,Sodickson DK,Ipek O,Collins CM,Gruetter R

    更新日期:2015-07-01 00:00:00

  • A unique anisotropic R2 of collagen degeneration (ARCADE) mapping as an efficient alternative to composite relaxation metric (R2 -R1 ρ ) in human knee cartilage study.

    abstract:PURPOSE:Anisotropic transverse R2 (1/T2 ) relaxation of water proton is sensitive to cartilage degenerative changes. The purpose is to develop an efficient method to extract this relaxation metric in clinical studies. METHODS:Anisotropic R2 can be measured inefficiently by standard R2 mapping after removing an isotrop...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27621

    authors: Pang Y,Palmieri-Smith RM,Malyarenko DI,Swanson SD,Chenevert TL

    更新日期:2019-06-01 00:00:00

  • Fast, three-dimensional free-breathing MR imaging of myocardial infarction: a feasibility study.

    abstract::Imaging delayed hyperenhancement of myocardial infarction is most commonly performed using an inversion recovery (IR) prepared 2D breathhold segmented k-space gradient echo (FGRE) sequence. Since only one slice is acquired per breathhold in this technique, 12-16 successive breathholds are required for complete anatomi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20061

    authors: Saranathan M,Rochitte CE,Foo TK

    更新日期:2004-05-01 00:00:00