Fast oxygen-enhanced multislice imaging of the lung using parallel acquisition techniques.

Abstract:

:The purpose of this study was to evaluate an optimized multislice acquisition technique for oxygen-enhanced MRI of the lung using slice-selective inversion and refocusing pulses in combination with parallel imaging. An inversion recovery HASTE sequence was implemented with respiratory triggering to perform imaging in end-expiration and with ECG triggering to avoid image acquisition during the systolic phase. Inversion pulses and the readout of echo trains could be interleaved to decrease acquisition time. The sequence was evaluated in 15 healthy volunteers, comparing three acquisition schemes: (1) acquisition of four slices without parallel imaging; (2) acquisition of four slices with parallel imaging; (3) acquisition of six slices with parallel imaging. These multislice acquisitions were repeated 80 times with alternating inhalation of room air and oxygen. The oxygen-induced signal increase showed no significant difference with and without parallel imaging. However, only with parallel imaging did the interleaved acquisition of six or more slices become possible, thus enabling a more complete anatomic coverage of the lung. The average required end-expiration time per repetition to acquire six slices could be significantly reduced from 4112 ms without to 2727 ms with parallel imaging. Total acquisition time varied between 8 and 13 min depending on the respiratory frequency.

journal_name

Magn Reson Med

authors

Dietrich O,Losert C,Attenberger U,Fasol U,Peller M,Nikolaou K,Reiser MF,Schoenberg SO

doi

10.1002/mrm.20495

subject

Has Abstract

pub_date

2005-06-01 00:00:00

pages

1317-25

issue

6

eissn

0740-3194

issn

1522-2594

journal_volume

53

pub_type

杂志文章
  • Stability assessment of gadolinium complexes by P-31 and H-1 relaxometry.

    abstract::Longitudinal P-31 relaxation rate enhancements of phosphate groups have been measured at pH 7-7.2 and 310 degrees K on aqueous solutions containing adenosine triphosphate (ATP), phosphocreatine (PCr), inorganic phosphate (Pi) and some lanthanide complexes (Gd-DOTA, Gd-HPDO3A, Gd-DO3A, Gd-DTPA, Gd-DTPA-BMA). The macroc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310413

    authors: Vander Elst L,Van Haverbeke Y,Goudemant JF,Muller RN

    更新日期:1994-04-01 00:00:00

  • "PINOT": time-resolved parallel magnetic resonance imaging with a reduced dynamic field of view.

    abstract::This article introduces a novel method named "Parallel Imaging and Noquist in Tandem" (PINOT) for accelerated image acquisition of cine cardiac magnetic resonance imaging. This method combines two prior information formalisms, the SPACE-RIP implementation of parallel imaging and the Noquist method for reduced-data ima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22696

    authors: Hamilton LH,Fabregat JA,Moratal D,Ramamurthy S,Lerakis S,Parks WJ,Sallee D 3rd,Brummer ME

    更新日期:2011-04-01 00:00:00

  • A strictly noninvasive MR setup dedicated to longitudinal studies of mechanical performance, bioenergetics, anatomy, and muscle recruitment in contracting mouse skeletal muscle.

    abstract::MR techniques have proven their ability to investigate skeletal muscle function in situ. Their benefit in terms of noninvasiveness is, however, lost in animal research, given that muscle stimulation and force output measurements are usually achieved using invasive surgical procedures, thereby excluding repeated invest...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22386

    authors: Giannesini B,Vilmen C,Le Fur Y,Dalmasso C,Cozzone PJ,Bendahan D

    更新日期:2010-07-01 00:00:00

  • Characterization of anomalous relaxation using the time-fractional Bloch equation and multiple echo T2 *-weighted magnetic resonance imaging at 7 T.

    abstract:PURPOSE:To study the utility of fractional calculus in modeling gradient-recalled echo MRI signal decay in the normal human brain. METHODS:We solved analytically the extended time-fractional Bloch equations resulting in five model parameters, namely, the amplitude, relaxation rate, order of the time-fractional derivat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26222

    authors: Qin S,Liu F,Turner IW,Yu Q,Yang Q,Vegh V

    更新日期:2017-04-01 00:00:00

  • Convex gradient optimization for increased spatiotemporal resolution and improved accuracy in phase contrast MRI.

    abstract:PURPOSE:To evaluate convex gradient optimization (CVX) for increased spatiotemporal resolution and improved accuracy for phase-contrast MRI (PC-MRI). METHODS:A conventional flow-compensated and flow-encoded (FCFE) PC-MRI sequence was compared with a CVX PC-MRI sequence using numerical simulations, flow phantom experim...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25059

    authors: Middione MJ,Wu HH,Ennis DB

    更新日期:2014-12-01 00:00:00

  • Feasibility of multiple-mouse dynamic contrast-enhanced MRI.

    abstract::Dynamic contrast-enhanced (DCE-) MRI is often used to evaluate the response to experimental antiangiogenic therapies in small animal models of cancer. Unfortunately, DCE-MRI studies often require a substantial investment of both time and money to achieve the desired level of statistical significance. Multiple-mouse MR...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21348

    authors: Ramirez MS,Ragan DK,Kundra V,Bankson JA

    更新日期:2007-09-01 00:00:00

  • Nuclear magnetic resonance parameters for monitoring coagulation of liver tissue.

    abstract::A new NMR parameter is suggested as a sensitive tool for monitoring thermal coagulation of liver tissue. That parameter is the proton magnetization exchange time (tau(MEX)) between water and the proteins. tau(MEX) was very sensitive to coagulation and insensitive to temperature, therefore representing only damage to t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20693

    authors: Carasso D,Eliav U,Navon G

    更新日期:2005-11-01 00:00:00

  • MR imaging with hyperpolarized 3He gas.

    abstract::Magnetic resonance images of the lungs of a guinea pig have been produced using hyperpolarized helium as the source of the MR signal. The resulting images are not yet sufficiently optimized to reveal fine structural detail within the lung, but the spectacular signal from this normally signal-deficient organ system off...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330219

    authors: Middleton H,Black RD,Saam B,Cates GD,Cofer GP,Guenther R,Happer W,Hedlund LW,Johnson GA,Juvan K

    更新日期:1995-02-01 00:00:00

  • Intracellular bimodal nanoparticles based on quantum dots for high-field MRI at 21.1 T.

    abstract::Multimodal, biocompatible contrast agents for high magnetic field applications represent a new class of nanomaterials with significant potential for tracking of fluorescence and MR in vitro and vivo. Optimized for high-field MR applications-including biomedical imaging at 21.1 T, the highest magnetic field available f...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22441

    authors: Rosenberg JT,Kogot JM,Lovingood DD,Strouse GF,Grant SC

    更新日期:2010-09-01 00:00:00

  • Cerebrospinal fluid-suppressed high-resolution diffusion imaging of human brain.

    abstract::A cerebrospinal fluid (CSF)-suppressed flow-attenuated inversion recovery (FLAIR) double-shot diffusion echo-planar imaging (EPI) sequence was developed and used, along with a non-CSF-suppressed version of the sequence, to determine the extent of the contribution of CSF partial-volume averaging to the apparent diffusi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370117

    authors: Falconer JC,Narayana PA

    更新日期:1997-01-01 00:00:00

  • Dynamic field map estimation using a spiral-in/spiral-out acquisition.

    abstract::The long readout times of single-shot acquisitions and the high field strengths desired for functional MRI (fMRI) using blood oxygenation level-dependent (BOLD) contrast make functional scans sensitive to magnetic field inhomogeneity. If it is not corrected during image reconstruction, field inhomogeneity can cause ge...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20079

    authors: Sutton BP,Noll DC,Fessler JA

    更新日期:2004-06-01 00:00:00

  • Shielded-coaxial-cable coils as receive and transceive array elements for 7T human MRI.

    abstract:PURPOSE:To investigate the use of shielded-coaxial-cable (SCC) coils as elements for multi-channel receive-only and transceive arrays for 7T human MRI and to compare their performance with equivalently sized conventional loop coils. METHODS:The SCC coil element consists of a coaxial loop with interrupted central condu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27964

    authors: Ruytenberg T,Webb A,Zivkovic I

    更新日期:2020-03-01 00:00:00

  • Application of phase rotation to STRESS localization scheme at 3 T.

    abstract:PURPOSE:Application of phase rotation to the STRESS (=STEAM+PRESS) localization scheme, to shorten echo time, minimize J-coupling dephasing and estimate B1+ inhomogeneity. STRESS (=STEAM + PRESS) simultaneously refocuses and acquires the double spin echo (SE123 ) and stimulated echo (STE- ) pathways, combining PRESS-li...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26911

    authors: Volovyk O,Tal A

    更新日期:2018-05-01 00:00:00

  • Histogram analysis of the microvasculature of intracerebral human and murine glioma xenografts.

    abstract::The purpose of this study is to examine the usefulness of histogram analysis combined with vessel size index (VSI) magnetic resonance imaging for the specific characterization of brain tumor microvasculature in a panel of six volume-matched glioma xenografts. Using a simple descriptive histogram analysis, significant ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22675

    authors: Just N

    更新日期:2011-03-01 00:00:00

  • Continuous assessment of relative cerebral blood volume in transient ischemia using steady state susceptibility-contrast MRI.

    abstract::The utility of a noninvasive steady state susceptibility-contrast MRI technique for continuous measurement of relative cerebral blood volume (rCBV) during global transient ischemia and subsequent hyperemia in a feline ischemia model is demonstrated. The measurements were obtained during a 10-min period of occlusion an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350207

    authors: Hamberg LM,Boccalini P,Stranjalis G,Hunter GJ,Huang Z,Halpern E,Weisskoff RM,Moskowitz MA,Rosen BR

    更新日期:1996-02-01 00:00:00

  • Evaluation of multicontrast MRI including fat suppression and inversion recovery spin echo for identification of intra-plaque hemorrhage and lipid core in human carotid plaque using the mahalanobis distance measure.

    abstract::Intra-plaque hemorrhage (IPH) and lipid core, characteristics of rupture prone carotid plaques, are often visualized in vivo with MRI using T1 weighted gradient and spin echo, respectively. Increasing magnetic field strength may help to identify IPH and lipid core better. As a proof of concept, automatic segmentation ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23191

    authors: te Boekhorst BC,van 't Klooster R,Bovens SM,van de Kolk KW,Cramer MJ,van Oosterhout MF,Doevendans PA,van der Geest RJ,Pasterkamp G,van Echteld CJ

    更新日期:2012-06-01 00:00:00

  • Real-time method for motion-compensated MR thermometry and MRgHIFU treatment in abdominal organs.

    abstract:PURPOSE:Magnetic resonance-guided high-intensity focused ultrasound is considered to be a promising treatment for localized cancer in abdominal organs such as liver, pancreas, or kidney. Abdominal motion, anatomical arrangement, and required sustained sonication are the main challenges. METHODS:MR acquisition consiste...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25017

    authors: Celicanin Z,Auboiroux V,Bieri O,Petrusca L,Santini F,Viallon M,Scheffler K,Salomir R

    更新日期:2014-10-01 00:00:00

  • Rapid T2 estimation with phase-cycled variable nutation steady-state free precession.

    abstract::Variable nutation SSFP (DESPOT2) permits rapid, high-resolution determination of the transverse (T2) relaxation constant. A limitation of DESPOT2, however, is the presence of T2 voids due to off-resonance banding artifacts associated with SSFP images. These artifacts typically occur in images acquired with long repeti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20159

    authors: Deoni SC,Ward HA,Peters TM,Rutt BK

    更新日期:2004-08-01 00:00:00

  • Calculation of signal intensities in hybrid sequences for fast NMR imaging.

    abstract::A number of techniques that recently have been used for fast NMR-imaging are based on a hybrid sequence of echo planar imaging (EPI) and FLASH imaging: after each NMR excitation several k-space lines are measured. The complete k-space is covered by performance of several excitations. It has been observed that there is...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340328

    authors: Deichmann R,Adolf H,Nöth U,Kuchenbrod E,Schwarzbauer C,Haase A

    更新日期:1995-09-01 00:00:00

  • Real-time interactive MRI-guided cardiac surgery: aortic valve replacement using a direct apical approach.

    abstract::Minimally invasive cardiac surgery requires arresting and emptying of the heart, which compromises visualization of the surgical field. In this feasibility study a novel surgical procedure is demonstrated in which real-time MRI is used to guide the placement of a prosthetic aortic valve in the beating heart via direct...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21044

    authors: McVeigh ER,Guttman MA,Lederman RJ,Li M,Kocaturk O,Hunt T,Kozlov S,Horvath KA

    更新日期:2006-11-01 00:00:00

  • In vivo measurement of volumetric strain in the human brain induced by arterial pulsation and harmonic waves.

    abstract::Motion-sensitive phase contrast magnetic resonance imaging and magnetic resonance elastography are applied for the measurement of volumetric strain and tissue compressibility in human brain. Volumetric strain calculated by the divergence operator using a biphasic effective-medium model is related to dilatation and com...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24499

    authors: Hirsch S,Klatt D,Freimann F,Scheel M,Braun J,Sack I

    更新日期:2013-09-01 00:00:00

  • A flexible 32-channel receive array combined with a homogeneous transmit coil for human lung imaging with hyperpolarized 3He at 1.5 T.

    abstract::Parallel imaging presents a promising approach for MRI of hyperpolarized nuclei, as the penalty in signal-to-noise ratio typically encountered with (1)H MRI due to a reduction in acquisition time can be offset by an increase in flip angle. The signal-to-noise ratio of hyperpolarized MRI generally exhibits a strong dep...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22962

    authors: Deppe MH,Parra-Robles J,Marshall H,Lanz T,Wild JM

    更新日期:2011-12-01 00:00:00

  • Coherence transfer by isotropic mixing in Carr-Purcell-Meiboom-Gill imaging: implications for the bright fat phenomenon in fast spin-echo imaging.

    abstract::It is well known that when compared to conventional spin-echo (CSE) imaging for equivalent effective echo times, fast spin-echo (FSE) imaging experiments yield higher signal intensities for coupled spin systems, such as that for lipid. One hypothesis put forth for this phenomenon is the removal of scalar coupling-base...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350409

    authors: Williamson DS,Mulken RV,Jakab PD,Jolesz FA

    更新日期:1996-04-01 00:00:00

  • Hyperpolarized 13C MRI of the pulmonary vasculature and parenchyma.

    abstract::The study of lung perfusion in normal and diseased subjects is of great interest to physiologists and physicians. In this work we demonstrate the application of a liquid-phase hyperpolarized (HP) carbon-13 ((13)C) tracer to magnetic resonance imaging (MRI) of the pulmonary vasculature and pulmonary perfusion in a porc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21168

    authors: Ishii M,Emami K,Kadlecek S,Petersson JS,Golman K,Vahdat V,Yu J,Cadman RV,MacDuffie-Woodburn J,Stephen M,Lipson DA,Rizi RR

    更新日期:2007-03-01 00:00:00

  • Simultaneous Quantification of Bone Edema/Adiposity and Structure in Inflamed Bone Using Chemical Shift-Encoded MRI in Spondyloarthritis.

    abstract:PURPOSE:To evaluate proton density fat fraction (PDFF) and R2* as markers of bone marrow composition and structure in inflamed bone in patients with spondyloarthritis. METHODS:Phantoms containing fat, water, and trabecular bone were constructed with proton density fat fraction (PDFF) and bone mineral density (BMD) val...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26729

    authors: Bray TJP,Bainbridge A,Punwani S,Ioannou Y,Hall-Craggs MA

    更新日期:2018-02-01 00:00:00

  • Spiral trajectory design: a flexible numerical algorithm and base analytical equations.

    abstract:PURPOSE:Spiral-based trajectories for magnetic resonance imaging can be advantageous, but are often cumbersome to design or create. This work presents a flexible numerical algorithm for designing trajectories based on explicit definition of radial undersampling, and also gives several analytical expressions for charact...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24675

    authors: Pipe JG,Zwart NR

    更新日期:2014-01-01 00:00:00

  • Impact of incidental magnetization transfer effects on inversion-recovery sequences that use a fast spin-echo readout.

    abstract::Multislice MR images obtained using a fast spin-echo (FSE) readout are strongly affected by magnetization transfer (MT) effects, which will cause a decrease in the observed longitudinal relaxation times for tissues with a large bound water component. This is pertinent for FSE-based inversion-recovery (IR) sequences, a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21338

    authors: Meara SJ,Barker GJ

    更新日期:2007-10-01 00:00:00

  • Echo shape analysis and image size adjustment on the level of echoes: improvement of parameter-selective proton images.

    abstract::Parameter-selective imaging for tissue characterization is performed at low magnetic fields (0.24-0.28 T) employing echo trains with a large number of echoes (less than or equal to 50), high-power pulses, and the projection reconstruction method. Preprocessing of the raw echoes is important for the quality of the echo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030306

    authors: Staemmler M,Gersonde K

    更新日期:1986-06-01 00:00:00

  • Multiple-coil k-space interpolation enhances resolution in single-shot spatiotemporal MRI.

    abstract:PURPOSE:Spatio-temporal encoding (SPEN) experiments can deliver single-scan MR images without folding complications and with robustness to chemical shift and susceptibility artifacts. Further resolution improvements are shown to arise by relying on multiple receivers, to interpolate the sampled data along the low-bandw...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26731

    authors: Liberman G,Solomon E,Lustig M,Frydman L

    更新日期:2018-02-01 00:00:00

  • The impact of the relaxivity definition on the quantitative measurement of glycosaminoglycans in cartilage by the MRI dGEMRIC method.

    abstract::The relaxivities (R-values) of the gadolinium diethylene triamine pentaacetic acid (Gd(DTPA)2-) ions in a series of skim-milk solutions at 0-40% milk concentrations were measured using NMR spectroscopy. The R-value was found to be approximately linearly proportional to the concentration of the solid component in the m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22169

    authors: Zheng S,Xia Y

    更新日期:2010-01-01 00:00:00