Abstract:
:A new NMR parameter is suggested as a sensitive tool for monitoring thermal coagulation of liver tissue. That parameter is the proton magnetization exchange time (tau(MEX)) between water and the proteins. tau(MEX) was very sensitive to coagulation and insensitive to temperature, therefore representing only damage to the tissue, independent of effects caused by temperature fluctuations. The measurement of tau(MEX) by two different methods revealed the existence of two or more groups of proteins, characterized by their different transverse relaxation time, and tau(MEX).
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Carasso D,Eliav U,Navon Gdoi
10.1002/mrm.20693subject
Has Abstractpub_date
2005-11-01 00:00:00pages
1082-6issue
5eissn
0740-3194issn
1522-2594journal_volume
54pub_type
杂志文章abstract::The authors present their 1-year experience with the use of 3DFT, time-of-flight MR angiography for the evaluation of vascular diseases of the head and neck. Their experience with over 150 patients indicates that this examination may be performed in conjunction with standard spin-echo imaging with only a minimal incre...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910140215
更新日期:1990-05-01 00:00:00
abstract::Optimal control theory has been applied in the past for the design of RF pulses for selective excitation. This was the outcome of having established the controllability of the MR spin system for the selective excitation problem. "Minimum distance" was the main formulation used for the solution. Because of their robust...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910360311
更新日期:1996-09-01 00:00:00
abstract::In proton magnetic resonance imaging (MRI) metallic substances lead to magnetic field distortions that often result in signal voids in the adjacent anatomic structures. Thus, metallic objects and superparamagnetic iron oxide (SPIO)-labeled cells appear as hypointense artifacts that obscure the underlying anatomy. The ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21399
更新日期:2007-11-01 00:00:00
abstract:PURPOSE:Spiral-based trajectories for magnetic resonance imaging can be advantageous, but are often cumbersome to design or create. This work presents a flexible numerical algorithm for designing trajectories based on explicit definition of radial undersampling, and also gives several analytical expressions for charact...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24675
更新日期:2014-01-01 00:00:00
abstract::Since contrast in magnetic resonance imaging (MRI) is so sensitive to the magnetic relaxation rates of tissue protons, the use of paramagnetic ions to alter contrast in a tissue-specific fashion is an alluring prospect. The influence of these ions on the proton relaxation rates in homogeneous solutions is known to var...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910020206
更新日期:1985-04-01 00:00:00
abstract::Magnetic resonance images of the lungs of a guinea pig have been produced using hyperpolarized helium as the source of the MR signal. The resulting images are not yet sufficiently optimized to reveal fine structural detail within the lung, but the spectacular signal from this normally signal-deficient organ system off...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910330219
更新日期:1995-02-01 00:00:00
abstract:PURPOSE:To assess the feasibility of using dissolved hyperpolarized xenon-129 (129 Xe) MRI to study renal physiology in humans at 3 T. METHODS:Using a flexible transceiver RF coil, dynamic and spatially resolved 129 Xe spectroscopy was performed in the abdomen after inhalation of hyperpolarized 129 Xe gas with 3 healt...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27923
更新日期:2020-01-01 00:00:00
abstract:PURPOSE:Myocardial effective relaxation time T2* is commonly regarded as a surrogate for myocardial tissue oxygenation. However, it is legitimate to assume that there are multiple factors that influence T2*. To this end, this study investigates the relationship between T2* and cardiac macromorphology given by left vent...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26312
更新日期:2017-06-01 00:00:00
abstract::Short image acquisition times and sensitivity to magnetic susceptibility favor the use of gradient echo imaging methods in functional MRI (fMRI). However, magnetic susceptibility effects attributed to air-tissue interfaces also lead to severe signal loss in images of the large inferior frontal and lateral temporal cor...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910370304
更新日期:1997-03-01 00:00:00
abstract::For clinical 31P MR spectroscopic imaging (MRSI) studies, where signal averaging is necessary, some improvement of sensitivity and spatial response function may be achieved by acquiring data over a spherical k-space volume and varying the number of averages acquired in proportion to the desired spatial filter. Eight d...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910360321
更新日期:1996-09-01 00:00:00
abstract::For perfusion-based functional magnetic resonance imaging, the previously introduced flow-sensitive alternating inversion recovery (FAIR) technique is combined with single-shot RARE (rapid acquisition with relaxation enhancement) and GRASE (gradient and spin echo) imaging sequences. The advantages of these sequences c...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199901)41:1<132::aid-mrm18
更新日期:1999-01-01 00:00:00
abstract:PURPOSE:To significantly reduce the background phase effects, especially at the air-tissue interface, and to enhance the desirable local structures of veins in susceptibility-weighted imaging. METHODS:In the proposed reconstruction method called Magnitude of Complex Filtering, a complex-valued magnetic resonance image...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24776
更新日期:2014-03-01 00:00:00
abstract:PURPOSE:To facilitate assessment of RF power deposition and temperature rise within the breast, we present a method to seamlessly join heterogeneous breast models with standard whole-body models and demonstrate simulations at 7 T. METHODS:Finite-difference time-domain electromagnetic and bioheat simulations are perfor...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27395
更新日期:2019-02-01 00:00:00
abstract:PURPOSE:To assess the use of image registration for correcting respiratory motion in free breathing lung T1 mapping acquisition in patients with idiopathic pulmonary fibrosis (IPF). THEORY AND METHODS:The method presented used image registration to synthetic images during postprocessing to remove respiratory motion. S...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28342
更新日期:2020-12-01 00:00:00
abstract::Accurate quantification of myocardial perfusion remains challenging due to saturation of the arterial input function at high contrast concentrations. A method for estimating the arterial input function directly from tissue curves in the myocardium that avoids these difficulties is presented. In this constrained altern...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22809
更新日期:2011-08-01 00:00:00
abstract::Two-dimensional T2-selective proton imaging of human head has been performed at 10 MHz employing Carr-Purcell-Gill-Meiboom pulse trains with echo separation of 6 and 12 msec. Using the information of 36 spin echoes and applying a recovery time of 2 sec the magnetization decay has been traced. The multi-exponential T2 ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910010406
更新日期:1984-12-01 00:00:00
abstract::The accurate assessment of pulmonary perfusion is especially important in the evaluation of patients with suspected pulmonary embolism, a common and potentially lethal disorder that can be treated by aggressive anticoagulation. In this study, we demonstrate for the first time the use of MR to image pulmonary perfusion...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910360402
更新日期:1996-10-01 00:00:00
abstract:PURPOSE:Magnetically labeled cells and tissue iron deposits provide qualitative means to detect and monitor cardiovascular and cerebrovascular diseases with magnetic resonance imaging. However, to quantitatively examine the extent of pathological micromorphological changes, detailed knowledge about microstructural para...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25196
更新日期:2014-05-01 00:00:00
abstract::The purpose of this study is to examine the usefulness of histogram analysis combined with vessel size index (VSI) magnetic resonance imaging for the specific characterization of brain tumor microvasculature in a panel of six volume-matched glioma xenografts. Using a simple descriptive histogram analysis, significant ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22675
更新日期:2011-03-01 00:00:00
abstract::We applied diffusion-sensitive echo planar (Instascan) imaging to study thermal changes caused by a Nd:YAG laser. Images of phantom materials and normal rabbit brain tissue in vivo, acquired in 150 ms, every 2s, clearly showed the dynamics of temperature-related signal intensity changes in the regions irradiated by th...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910210116
更新日期:1991-09-01 00:00:00
abstract::A common type of motion present in clinical magnetic resonance imaging examinations is rotational motion, such as that due to voluntary motion during head examinations. The correction scheme presented in this work offers a method for eliminating the effects of rotations within the imaging plane. Integral to the implem...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910330511
更新日期:1995-05-01 00:00:00
abstract::The orientation dependence of the free induction decay (FID) of 1H NMR water signal in ex vivo bovine digital flexor tendon at the native level of hydration is reported. Residual dipolar coupling due to the overall tissue anisotropy produces a 6:1 change in the signal intensity as an angle between the long axis of a s...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20540
更新日期:2005-08-01 00:00:00
abstract::Saline solutions of manganese ions (Mn2+) were used as articular contrast agents in magnetic resonance microscopy (9.4 T) of cartilage of chicken femoral condyles and pig temporomandibular joints. The diffusion of Mn2+ from the articular surface into the cartilage matrix led to a strong contrast enhancement in the car...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910240114
更新日期:1992-03-01 00:00:00
abstract::A novel method, called relaxo-oximetry, for rapid spatially resolved in vivo measurements of oxygen concentration using time-domain radiofrequency (RF) electron paramagnetic resonance (EPR) is described. Time-domain data from triaryl methyl (TAM)-based single-electron contrast agents were processed by systematic delet...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10133
更新日期:2002-05-01 00:00:00
abstract::Deuterium (2H) double-quantum filtered (DQF) NMR spectroscopy of nucleus pulposus (NP) tissues from human intervertebral discs is reported. The DQF spectral intensities, DQ build-up rates, and DQF-detected rotating-frame spin-lattice relaxation times are sensitive to the degree of hydration of the NP tissue, and displ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21231
更新日期:2007-06-01 00:00:00
abstract::A modular, user-friendly computer simulation of NMR imaging was created for the DEC VAX computer. This simulation is novel in that complex imaging phenomena, such as chemical shifts and flow, may be easily studied. Other features include spin warp and backprojection imaging, movie generation, and simulation of image c...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910030302
更新日期:1986-06-01 00:00:00
abstract:PURPOSE:To assess the risk of radiofrequency (RF)-induced heating in patients with MR-conditional pacemaker (PM) systems, in the presence of another lead abandoned from a previous implant. METHODS:Four commercial pacemaker leads were placed beside a MR-conditional PM system, inside a human trunk simulator. The phantom...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25106
更新日期:2015-01-01 00:00:00
abstract::Magnetic resonance imaging allows numerous k-space sampling schemes such as cartesian, polar, spherical, and other non-rectilinear trajectories. Non-rectilinear MR acquisitions permit fast scan times and can suppress motion artifacts. Still, these sampling schemes may adversely affect the image characteristics due to ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910360617
更新日期:1996-12-01 00:00:00
abstract::A new k-space direct matrix inversion (DMI) method is proposed here to accelerate non-Cartesian SENSE reconstructions. In this method a global k-space matrix equation is established on basic MRI principles, and the inverse of the global encoding matrix is found from a set of local matrix equations by taking advantage ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20974
更新日期:2006-08-01 00:00:00
abstract::Keyhole acquisition techniques have been used to reduce image acquisition times primarily in contrast agent studies and via simulation in interventional MRI procedures. More recent simulations have suggested that improved definition of an interventional device [e.g., biopsy needles, radio frequency (RF) electrodes] co...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199909)42:3<554::aid-mrm18
更新日期:1999-09-01 00:00:00