Nuclear magnetic resonance parameters for monitoring coagulation of liver tissue.

Abstract:

:A new NMR parameter is suggested as a sensitive tool for monitoring thermal coagulation of liver tissue. That parameter is the proton magnetization exchange time (tau(MEX)) between water and the proteins. tau(MEX) was very sensitive to coagulation and insensitive to temperature, therefore representing only damage to the tissue, independent of effects caused by temperature fluctuations. The measurement of tau(MEX) by two different methods revealed the existence of two or more groups of proteins, characterized by their different transverse relaxation time, and tau(MEX).

journal_name

Magn Reson Med

authors

Carasso D,Eliav U,Navon G

doi

10.1002/mrm.20693

subject

Has Abstract

pub_date

2005-11-01 00:00:00

pages

1082-6

issue

5

eissn

0740-3194

issn

1522-2594

journal_volume

54

pub_type

杂志文章
  • Carotid-CNS MR flow imaging.

    abstract::The authors present their 1-year experience with the use of 3DFT, time-of-flight MR angiography for the evaluation of vascular diseases of the head and neck. Their experience with over 150 patients indicates that this examination may be performed in conjunction with standard spin-echo imaging with only a minimal incre...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910140215

    authors: Masaryk TJ,Laub GA,Modic MT,Ross JS,Haacke EM

    更新日期:1990-05-01 00:00:00

  • Design of adiabatic selective pulses using optimal control theory.

    abstract::Optimal control theory has been applied in the past for the design of RF pulses for selective excitation. This was the outcome of having established the controllability of the MR spin system for the selective excitation problem. "Minimum distance" was the main formulation used for the solution. Because of their robust...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360311

    authors: Rosenfeld D,Zur Y

    更新日期:1996-09-01 00:00:00

  • Positive contrast visualization of iron oxide-labeled stem cells using inversion-recovery with ON-resonant water suppression (IRON).

    abstract::In proton magnetic resonance imaging (MRI) metallic substances lead to magnetic field distortions that often result in signal voids in the adjacent anatomic structures. Thus, metallic objects and superparamagnetic iron oxide (SPIO)-labeled cells appear as hypointense artifacts that obscure the underlying anatomy. The ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21399

    authors: Stuber M,Gilson WD,Schär M,Kedziorek DA,Hofmann LV,Shah S,Vonken EJ,Bulte JW,Kraitchman DL

    更新日期:2007-11-01 00:00:00

  • Spiral trajectory design: a flexible numerical algorithm and base analytical equations.

    abstract:PURPOSE:Spiral-based trajectories for magnetic resonance imaging can be advantageous, but are often cumbersome to design or create. This work presents a flexible numerical algorithm for designing trajectories based on explicit definition of radial undersampling, and also gives several analytical expressions for charact...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24675

    authors: Pipe JG,Zwart NR

    更新日期:2014-01-01 00:00:00

  • Magnetic field dependence of proton relaxation rates in tissue with added Mn2+: rabbit liver and kidney.

    abstract::Since contrast in magnetic resonance imaging (MRI) is so sensitive to the magnetic relaxation rates of tissue protons, the use of paramagnetic ions to alter contrast in a tissue-specific fashion is an alluring prospect. The influence of these ions on the proton relaxation rates in homogeneous solutions is known to var...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910020206

    authors: Koenig SH,Brown RD 3rd,Goldstein EJ,Burnett KR,Wolf GL

    更新日期:1985-04-01 00:00:00

  • MR imaging with hyperpolarized 3He gas.

    abstract::Magnetic resonance images of the lungs of a guinea pig have been produced using hyperpolarized helium as the source of the MR signal. The resulting images are not yet sufficiently optimized to reveal fine structural detail within the lung, but the spectacular signal from this normally signal-deficient organ system off...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330219

    authors: Middleton H,Black RD,Saam B,Cates GD,Cofer GP,Guenther R,Happer W,Hedlund LW,Johnson GA,Juvan K

    更新日期:1995-02-01 00:00:00

  • Dissolved hyperpolarized xenon-129 MRI in human kidneys.

    abstract:PURPOSE:To assess the feasibility of using dissolved hyperpolarized xenon-129 (129 Xe) MRI to study renal physiology in humans at 3 T. METHODS:Using a flexible transceiver RF coil, dynamic and spatially resolved 129 Xe spectroscopy was performed in the abdomen after inhalation of hyperpolarized 129 Xe gas with 3 healt...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27923

    authors: Chacon-Caldera J,Maunder A,Rao M,Norquay G,Rodgers OI,Clemence M,Puddu C,Schad LR,Wild JM

    更新日期:2020-01-01 00:00:00

  • Myocardial effective transverse relaxation time T2* Correlates with left ventricular wall thickness: A 7.0 T MRI study.

    abstract:PURPOSE:Myocardial effective relaxation time T2* is commonly regarded as a surrogate for myocardial tissue oxygenation. However, it is legitimate to assume that there are multiple factors that influence T2*. To this end, this study investigates the relationship between T2* and cardiac macromorphology given by left vent...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26312

    authors: Huelnhagen T,Hezel F,Serradas Duarte T,Pohlmann A,Oezerdem C,Flemming B,Seeliger E,Prothmann M,Schulz-Menger J,Niendorf T

    更新日期:2017-06-01 00:00:00

  • Multi-gradient echo with susceptibility inhomogeneity compensation (MGESIC): demonstration of fMRI in the olfactory cortex at 3.0 T.

    abstract::Short image acquisition times and sensitivity to magnetic susceptibility favor the use of gradient echo imaging methods in functional MRI (fMRI). However, magnetic susceptibility effects attributed to air-tissue interfaces also lead to severe signal loss in images of the large inferior frontal and lateral temporal cor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370304

    authors: Yang QX,Dardzinski BJ,Li S,Eslinger PJ,Smith MB

    更新日期:1997-03-01 00:00:00

  • Comparison of k-space sampling schemes for multidimensional MR spectroscopic imaging.

    abstract::For clinical 31P MR spectroscopic imaging (MRSI) studies, where signal averaging is necessary, some improvement of sensitivity and spatial response function may be achieved by acquiring data over a spherical k-space volume and varying the number of averages acquired in proportion to the desired spatial filter. Eight d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360321

    authors: Hugg JW,Maudsley AA,Weiner MW,Matson GB

    更新日期:1996-09-01 00:00:00

  • Perfusion-based functional magnetic resonance imaging with single-shot RARE and GRASE acquisitions.

    abstract::For perfusion-based functional magnetic resonance imaging, the previously introduced flow-sensitive alternating inversion recovery (FAIR) technique is combined with single-shot RARE (rapid acquisition with relaxation enhancement) and GRASE (gradient and spin echo) imaging sequences. The advantages of these sequences c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199901)41:1<132::aid-mrm18

    authors: Crelier GR,Hoge RD,Munger P,Pike GB

    更新日期:1999-01-01 00:00:00

  • A new susceptibility-weighted image reconstruction method for the reduction of background phase artifacts.

    abstract:PURPOSE:To significantly reduce the background phase effects, especially at the air-tissue interface, and to enhance the desirable local structures of veins in susceptibility-weighted imaging. METHODS:In the proposed reconstruction method called Magnitude of Complex Filtering, a complex-valued magnetic resonance image...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24776

    authors: Lee Y,Han Y,Park H

    更新日期:2014-03-01 00:00:00

  • Toward 7T breast MRI clinical study: safety assessment using simulation of heterogeneous breast models in RF exposure.

    abstract:PURPOSE:To facilitate assessment of RF power deposition and temperature rise within the breast, we present a method to seamlessly join heterogeneous breast models with standard whole-body models and demonstrate simulations at 7 T. METHODS:Finite-difference time-domain electromagnetic and bioheat simulations are perfor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27395

    authors: Li X,Rispoli JV

    更新日期:2019-02-01 00:00:00

  • Free breathing lung T1 mapping using image registration in patients with idiopathic pulmonary fibrosis.

    abstract:PURPOSE:To assess the use of image registration for correcting respiratory motion in free breathing lung T1 mapping acquisition in patients with idiopathic pulmonary fibrosis (IPF). THEORY AND METHODS:The method presented used image registration to synthetic images during postprocessing to remove respiratory motion. S...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28342

    authors: Saunders LC,Eaden JA,Bianchi SM,Swift AJ,Wild JM

    更新日期:2020-12-01 00:00:00

  • Constrained estimation of the arterial input function for myocardial perfusion cardiovascular magnetic resonance.

    abstract::Accurate quantification of myocardial perfusion remains challenging due to saturation of the arterial input function at high contrast concentrations. A method for estimating the arterial input function directly from tissue curves in the myocardium that avoids these difficulties is presented. In this constrained altern...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22809

    authors: Fluckiger JU,Schabel MC,DiBella EV

    更新日期:2011-08-01 00:00:00

  • Analysis of multiple T2 proton relaxation processes in human head and imaging on the basis of selective and assigned T2 values.

    abstract::Two-dimensional T2-selective proton imaging of human head has been performed at 10 MHz employing Carr-Purcell-Gill-Meiboom pulse trains with echo separation of 6 and 12 msec. Using the information of 36 spin echoes and applying a recovery time of 2 sec the magnetization decay has been traced. The multi-exponential T2 ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910010406

    authors: Gersonde K,Felsberg L,Tolxdorff T,Ratzel D,Ströbel B

    更新日期:1984-12-01 00:00:00

  • Pulmonary perfusion: qualitative assessment with dynamic contrast-enhanced MRI using ultra-short TE and inversion recovery turbo FLASH.

    abstract::The accurate assessment of pulmonary perfusion is especially important in the evaluation of patients with suspected pulmonary embolism, a common and potentially lethal disorder that can be treated by aggressive anticoagulation. In this study, we demonstrate for the first time the use of MR to image pulmonary perfusion...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360402

    authors: Hatabu H,Gaa J,Kim D,Li W,Prasad PV,Edelman RR

    更新日期:1996-10-01 00:00:00

  • Theoretical model of the single spin-echo relaxation time for spherical magnetic perturbers.

    abstract:PURPOSE:Magnetically labeled cells and tissue iron deposits provide qualitative means to detect and monitor cardiovascular and cerebrovascular diseases with magnetic resonance imaging. However, to quantitatively examine the extent of pathological micromorphological changes, detailed knowledge about microstructural para...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25196

    authors: Kurz FT,Kampf T,Heiland S,Bendszus M,Schlemmer HP,Ziener CH

    更新日期:2014-05-01 00:00:00

  • Histogram analysis of the microvasculature of intracerebral human and murine glioma xenografts.

    abstract::The purpose of this study is to examine the usefulness of histogram analysis combined with vessel size index (VSI) magnetic resonance imaging for the specific characterization of brain tumor microvasculature in a panel of six volume-matched glioma xenografts. Using a simple descriptive histogram analysis, significant ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22675

    authors: Just N

    更新日期:2011-03-01 00:00:00

  • Real-time magnetic resonance imaging of laser heat deposition in tissue.

    abstract::We applied diffusion-sensitive echo planar (Instascan) imaging to study thermal changes caused by a Nd:YAG laser. Images of phantom materials and normal rabbit brain tissue in vivo, acquired in 150 ms, every 2s, clearly showed the dynamics of temperature-related signal intensity changes in the regions irradiated by th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910210116

    authors: Bleier AR,Jolesz FA,Cohen MS,Weisskoff RM,Dalcanton JJ,Higuchi N,Feinberg DA,Rosen BR,McKinstry RC,Hushek SG

    更新日期:1991-09-01 00:00:00

  • Spatial-frequency-tuned markers and adaptive correction for rotational motion.

    abstract::A common type of motion present in clinical magnetic resonance imaging examinations is rotational motion, such as that due to voluntary motion during head examinations. The correction scheme presented in this work offers a method for eliminating the effects of rotations within the imaging plane. Integral to the implem...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330511

    authors: Korin HW,Felmlee JP,Riederer SJ,Ehman RL

    更新日期:1995-05-01 00:00:00

  • Water in tendon: orientational analysis of the free induction decay.

    abstract::The orientation dependence of the free induction decay (FID) of 1H NMR water signal in ex vivo bovine digital flexor tendon at the native level of hydration is reported. Residual dipolar coupling due to the overall tissue anisotropy produces a 6:1 change in the signal intensity as an angle between the long axis of a s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20540

    authors: Krasnosselskaia LV,Fullerton GD,Dodd SJ,Cameron IL

    更新日期:2005-08-01 00:00:00

  • MR microimaging of articular cartilage and contrast enhancement by manganese ions.

    abstract::Saline solutions of manganese ions (Mn2+) were used as articular contrast agents in magnetic resonance microscopy (9.4 T) of cartilage of chicken femoral condyles and pig temporomandibular joints. The diffusion of Mn2+ from the articular surface into the cartilage matrix led to a strong contrast enhancement in the car...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910240114

    authors: Kusaka Y,Gründer W,Rumpel H,Dannhauer KH,Gersonde K

    更新日期:1992-03-01 00:00:00

  • Noninvasive in vivo oximetric imaging by radiofrequency FT EPR.

    abstract::A novel method, called relaxo-oximetry, for rapid spatially resolved in vivo measurements of oxygen concentration using time-domain radiofrequency (RF) electron paramagnetic resonance (EPR) is described. Time-domain data from triaryl methyl (TAM)-based single-electron contrast agents were processed by systematic delet...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10133

    authors: Subramanian S,Yamada K,Irie A,Murugesan R,Cook JA,Devasahayam N,Van Dam GM,Mitchell JB,Krishna MC

    更新日期:2002-05-01 00:00:00

  • 2H double quantum filtered (DQF) NMR spectroscopy of the nucleus pulposus tissues of the intervertebral disc.

    abstract::Deuterium (2H) double-quantum filtered (DQF) NMR spectroscopy of nucleus pulposus (NP) tissues from human intervertebral discs is reported. The DQF spectral intensities, DQ build-up rates, and DQF-detected rotating-frame spin-lattice relaxation times are sensitive to the degree of hydration of the NP tissue, and displ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21231

    authors: Perea W,Cannella M,Yang J,Vega AJ,Polenova T,Marcolongo M

    更新日期:2007-06-01 00:00:00

  • A computer simulation of nuclear magnetic resonance imaging.

    abstract::A modular, user-friendly computer simulation of NMR imaging was created for the DEC VAX computer. This simulation is novel in that complex imaging phenomena, such as chemical shifts and flow, may be easily studied. Other features include spin warp and backprojection imaging, movie generation, and simulation of image c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030302

    authors: Summers RM,Axel L,Israel S

    更新日期:1986-06-01 00:00:00

  • Impact of capped and uncapped abandoned leads on the heating of an MR-conditional pacemaker implant.

    abstract:PURPOSE:To assess the risk of radiofrequency (RF)-induced heating in patients with MR-conditional pacemaker (PM) systems, in the presence of another lead abandoned from a previous implant. METHODS:Four commercial pacemaker leads were placed beside a MR-conditional PM system, inside a human trunk simulator. The phantom...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25106

    authors: Mattei E,Gentili G,Censi F,Triventi M,Calcagnini G

    更新日期:2015-01-01 00:00:00

  • Effects of polar sampling in k-space.

    abstract::Magnetic resonance imaging allows numerous k-space sampling schemes such as cartesian, polar, spherical, and other non-rectilinear trajectories. Non-rectilinear MR acquisitions permit fast scan times and can suppress motion artifacts. Still, these sampling schemes may adversely affect the image characteristics due to ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360617

    authors: Lauzon ML,Rutt BK

    更新日期:1996-12-01 00:00:00

  • Decomposed direct matrix inversion for fast non-cartesian SENSE reconstructions.

    abstract::A new k-space direct matrix inversion (DMI) method is proposed here to accelerate non-Cartesian SENSE reconstructions. In this method a global k-space matrix equation is established on basic MRI principles, and the inverse of the global encoding matrix is found from a set of local matrix equations by taking advantage ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20974

    authors: Qian Y,Zhang Z,Wang Y,Boada FE

    更新日期:2006-08-01 00:00:00

  • Improved device definition in interventional magnetic resonance imaging using a rotated stripes keyhole acquisition.

    abstract::Keyhole acquisition techniques have been used to reduce image acquisition times primarily in contrast agent studies and via simulation in interventional MRI procedures. More recent simulations have suggested that improved definition of an interventional device [e.g., biopsy needles, radio frequency (RF) electrodes] co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199909)42:3<554::aid-mrm18

    authors: Hwang KP,Lim J,Wendt M,Merkle E,Lewin JS,Duerk JL

    更新日期:1999-09-01 00:00:00