Optimization and validation of accelerated golden-angle radial sparse MRI reconstruction with self-calibrating GRAPPA operator gridding.

Abstract:

PURPOSE:Golden-angle radial sparse parallel (GRASP) MRI reconstruction requires gridding and regridding to transform data between radial and Cartesian k-space. These operations are repeatedly performed in each iteration, which makes the reconstruction computationally demanding. This work aimed to accelerate GRASP reconstruction using self-calibrating GRAPPA operator gridding (GROG) and to validate its performance in clinical imaging. METHODS:GROG is an alternative gridding approach based on parallel imaging, in which k-space data acquired on a non-Cartesian grid are shifted onto a Cartesian k-space grid using information from multicoil arrays. For iterative non-Cartesian image reconstruction, GROG is performed only once as a preprocessing step. Therefore, the subsequent iterative reconstruction can be performed directly in Cartesian space, which significantly reduces computational burden. Here, a framework combining GROG with GRASP (GROG-GRASP) is first optimized and then compared with standard GRASP reconstruction in 22 prostate patients. RESULTS:GROG-GRASP achieved approximately 4.2-fold reduction in reconstruction time compared with GRASP (∼333 min versus ∼78 min) while maintaining image quality (structural similarity index ≈ 0.97 and root mean square error ≈ 0.007). Visual image quality assessment by two experienced radiologists did not show significant differences between the two reconstruction schemes. With a graphics processing unit implementation, image reconstruction time can be further reduced to approximately 14 min. CONCLUSION:The GRASP reconstruction can be substantially accelerated using GROG. This framework is promising toward broader clinical application of GRASP and other iterative non-Cartesian reconstruction methods. Magn Reson Med 80:286-293, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

journal_name

Magn Reson Med

authors

Benkert T,Tian Y,Huang C,DiBella EVR,Chandarana H,Feng L

doi

10.1002/mrm.27030

subject

Has Abstract

pub_date

2018-07-01 00:00:00

pages

286-293

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

80

pub_type

杂志文章
  • Strategy for lipid suppression in lactate imaging using STIR-DQCT: a study of hypoxic-ischemic brain injury.

    abstract::In vivo lactate detection using gradient enhanced double quantum coherence transfer (DQCT) was significantly improved by addition of short-time-inversion-recovery (STIR). Phantom studies demonstrated lipid suppression down to the background noise level with 33% loss of lactate signal. In vivo studies using a rabbit mo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400416

    authors: Nakai T,Rhine WD,Okada T,Stevenson DK,Spielman DM

    更新日期:1998-10-01 00:00:00

  • Radial single-shot STEAM MRI.

    abstract::Rapid MR imaging using the stimulated echo acquisition mode (STEAM) technique yields single-shot images without any sensitivity to resonance offset effects. However, the absence of susceptibility-induced signal voids or geometric distortions is at the expense of a somewhat lower signal-to-noise ratio than EPI. As a co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21401

    authors: Block KT,Frahm J

    更新日期:2008-04-01 00:00:00

  • Use of high temperature superconductor in a receiver coil for magnetic resonance imaging.

    abstract::A planar YBa2Cu3Ox (YBCO) coil has been used as a pick-up coil in a nuclear magnetic resonance imager. It was found that the quality factor (Q) of the YBCO coil was greater than its copper counterpart by approaching 50% even in a field of 0.15 T. The Q of the copper coil at 77 K and in a field of 0.15 T was 1200 while...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910200218

    authors: Hall AS,Alford NM,Button TW,Gilderdale DJ,Gehring KA,Young IR

    更新日期:1991-08-01 00:00:00

  • Pharmacological MRI of the choroid and retina: blood flow and BOLD responses during nitroprusside infusion.

    abstract::Nitroprusside, a vasodilatory nitric oxide donor, is clinically used during vascular surgery and to lower blood pressure in acute hypertension. This article reports a novel application of blood flow (BF) and blood oxygenation level dependent (BOLD) MRI on an 11.7T scanner to image the rat chorioretinal BF and BOLD cha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24112

    authors: Shih YY,Li G,Muir ER,De La Garza BH,Kiel JW,Duong TQ

    更新日期:2012-10-01 00:00:00

  • Relaxometry of brain: why white matter appears bright in MRI.

    abstract::The remarkable success of magnetic resonance imaging of adult brain relates to the unusually large ratio of the longitudinal relaxation rates 1/T1 of white and gray matter, approximately 2:1 at physiological temperature and traditional imaging fields. Several investigators have conjectured that myelin is the source of...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910140306

    authors: Koenig SH,Brown RD 3rd,Spiller M,Lundbom N

    更新日期:1990-06-01 00:00:00

  • iDQC anisotropy map imaging for tumor tissue characterization in vivo.

    abstract::Intermolecular double quantum coherences (iDQCs), signals that result from simultaneous transitions of two or more separated spins, are known to produce images that are highly sensitive to subvoxel structure, particularly local anisotropy. Here we demonstrate how iDQCs signal can be used to efficiently detect the anis...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21925

    authors: Branca RT,Chen YM,Mouraviev V,Galiana G,Jenista ER,Kumar C,Leuschner C,Warren WS

    更新日期:2009-04-01 00:00:00

  • Continuous assessment of relative cerebral blood volume in transient ischemia using steady state susceptibility-contrast MRI.

    abstract::The utility of a noninvasive steady state susceptibility-contrast MRI technique for continuous measurement of relative cerebral blood volume (rCBV) during global transient ischemia and subsequent hyperemia in a feline ischemia model is demonstrated. The measurements were obtained during a 10-min period of occlusion an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350207

    authors: Hamberg LM,Boccalini P,Stranjalis G,Hunter GJ,Huang Z,Halpern E,Weisskoff RM,Moskowitz MA,Rosen BR

    更新日期:1996-02-01 00:00:00

  • Echo-planar time course MRI of cat brain oxygenation changes.

    abstract::When deoxygenated, blood behaves as an effective susceptibility contrast agent. Changes in brain oxygenation can be monitored using gradient-echo echo-planar imaging. With this technique, difference images also demonstrate that blood oxygenation is increased during periods of recovery from respiratory challenge. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910220117

    authors: Turner R,Le Bihan D,Moonen CT,Despres D,Frank J

    更新日期:1991-11-01 00:00:00

  • Phase-based T2 mapping with gradient echo imaging.

    abstract:PURPOSE:Transverse relaxation time (T2 ) mapping with MRI has a plethora of clinical and research applications. Current T2 mapping techniques are based primarily on spin-echo (SE) relaxometry strategies that rely on the signal magnitude, and often suffer from lengthy acquisition times. In this work, we propose a phase-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28138

    authors: Wang X,Hernando D,Reeder SB

    更新日期:2020-08-01 00:00:00

  • Multiple-coil k-space interpolation enhances resolution in single-shot spatiotemporal MRI.

    abstract:PURPOSE:Spatio-temporal encoding (SPEN) experiments can deliver single-scan MR images without folding complications and with robustness to chemical shift and susceptibility artifacts. Further resolution improvements are shown to arise by relying on multiple receivers, to interpolate the sampled data along the low-bandw...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26731

    authors: Liberman G,Solomon E,Lustig M,Frydman L

    更新日期:2018-02-01 00:00:00

  • MRI relaxation fluctuations in acute reperfused hemorrhagic infarction.

    abstract::MRI evaluations of intramyocardial hemorrhage in acute infarction have relied on T(2) and T(2)(*) shortening only. We propose a more comprehensive evaluation of hemorrhagic infarction based on the concept that fluctuations in T(2) and T(1) relaxation in acute reperfused infarction will reflect transient edema and hemo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21079

    authors: Foltz WD,Yang Y,Graham JJ,Detsky JS,Wright GA,Dick AJ

    更新日期:2006-12-01 00:00:00

  • Triple diffusion encoding MRI predicts intra-axonal and extra-axonal diffusion tensors in white matter.

    abstract:PURPOSE:To demonstrate how triple diffusion encoding (TDE) MRI can be applied to separately estimate the intra-axonal and extra-axonal diffusion tensors in white matter (WM). METHODS:Using a TDE pulse sequence with an axially symmetric b-matrix, diffusion MRI data were acquired at 3T for 3 healthy adults with an axial...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28084

    authors: Ramanna S,Moss HG,McKinnon ET,Yacoub E,Helpern JA,Jensen JH

    更新日期:2020-06-01 00:00:00

  • Suppression of physiological eye movement artifacts in functional MRI using slab presaturation.

    abstract::Reduction of image-to-image signal fluctuations and imaging artifacts is important for fMRI studies. The imaging artifacts caused by respiration, cardiac pulsation, and gross head motion and the suppression of these artifacts have been studied for many years. However, the artifacts caused by eye movement and their eff...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380407

    authors: Chen W,Zhu XH

    更新日期:1997-10-01 00:00:00

  • In vivo measurement of T2 distributions and water contents in normal human brain.

    abstract::Using a 32-echo imaging pulse sequence, T2 relaxation decay curves were acquired from five white- and six gray-matter brain structures outlined in 12 normal volunteers. The water contents of white and gray matter were 0.71 (0.01) and 0.83 (0.03) g/ml, respectively. All white-matter structures had significantly higher ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370107

    authors: Whittall KP,MacKay AL,Graeb DA,Nugent RA,Li DK,Paty DW

    更新日期:1997-01-01 00:00:00

  • Indirect 17(O)-magnetic resonance imaging of cerebral blood flow in the rat.

    abstract::Proton T(1rho)-dispersion MRI is demonstrated for indirect, in vivo detection of (17)O in the brain. This technique, which may be readily implemented on any clinical MRI scanner, is applied towards high-resolution, quantitative mapping of cerebral blood flow (CBF) in the rat by monitoring the clearance of (17)O-enrich...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10403

    authors: Tailor DR,Roy A,Regatte RR,Charagundla SR,McLaughlin AC,Leigh JS,Reddy R

    更新日期:2003-03-01 00:00:00

  • A new steady-state imaging sequence for simultaneous acquisition of two MR images with clearly different contrasts.

    abstract::We present a new steady-state imaging sequence, which simultaneously allows in a single acquisition the formation of two MR images with clearly different contrasts. The contrast of the first image is FISP-like, whereas the second image is strongly T2-weighted. In principle the T2 values in the image can be calculated ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910070105

    authors: Bruder H,Fischer H,Graumann R,Deimling M

    更新日期:1988-05-01 00:00:00

  • Comparison of measuring energy metabolism by different (31) P-magnetic resonance spectroscopy techniques in resting, ischemic, and exercising muscle.

    abstract::Alternate methods to quantify mitochondrial activity or function have been extensively used for studying insulin resistance and type 2 diabetes mellitus, namely saturation transfer and phosphocreatine (PCr) recovery. As these methods are in fact determining different parameters, this study aimed to compare saturation ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23095

    authors: Schmid AI,Schrauwen-Hinderling VB,Andreas M,Wolzt M,Moser E,Roden M

    更新日期:2012-04-01 00:00:00

  • Restricted field of view magnetic resonance imaging of a dynamic time series.

    abstract::A restricted field of view (rFOV) approach for imaging a dynamic time series of volumes of limited spatial extent within a larger subject is described. The shorter readout with rFOV-MRI can be exploited to either limit image artifacts or increase spatial resolution. To accomplish rFOV imaging of a multislice volume fo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21115

    authors: Pisani L,Bammer R,Glover G

    更新日期:2007-02-01 00:00:00

  • Abnormal brain anatomical topological organization of the cognitive-emotional and the frontoparietal circuitry in major depressive disorder.

    abstract:PURPOSE:Despite the increasing understanding of major depressive disorder (MDD) using neuroimaging techniques, the topological organization of anatomical networks underlying MDD remains unclear. METHODS:The topological organization of brain anatomical networks was explored using complex network approaches. Diffusion t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25036

    authors: Qin J,Wei M,Liu H,Yan R,Luo G,Yao Z,Lu Q

    更新日期:2014-11-01 00:00:00

  • Multi-echo length and offset VARied saturation (MeLOVARS) method for improved CEST imaging.

    abstract:PURPOSE:The aim of this study was to develop a technique for rapid collection of chemical exchange saturation transfer images with the saturation varied to modulate signal loss transfer and enhance contrast. METHODS:Multi-echo Length and Offset VARied Saturation (MeLOVARS) divides the saturation pulse of length Tsat i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25567

    authors: Song X,Xu J,Xia S,Yadav NN,Lal B,Laterra J,Bulte JW,van Zijl PC,McMahon MT

    更新日期:2015-02-01 00:00:00

  • Mapping connectomes with diffusion MRI: deterministic or probabilistic tractography?

    abstract:PURPOSE:Human connectomics necessitates high-throughput, whole-brain reconstruction of multiple white matter fiber bundles. Scaling up tractography to meet these high-throughput demands yields new fiber tracking challenges, such as minimizing spurious connections and controlling for gyral biases. The aim of this study ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27471

    authors: Sarwar T,Ramamohanarao K,Zalesky A

    更新日期:2019-02-01 00:00:00

  • A double-tuned probe for metabolic NMR studies.

    abstract::A double-tuned single coil probe for high field metabolic NMR studies has been designed and tested. The resonant coil is a single-turn of copper foil wound on a quartz cylinder. It is fed by a short length of parallel strip line made of the same material; the feeder is also used as a tuning capacitance. Electrical par...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910230216

    authors: Najim E,Grivet JP

    更新日期:1992-02-01 00:00:00

  • Moment and direction of the spoiler gradient for effective artifact suppression in RF-spoiled gradient echo imaging.

    abstract::Radiofrequency (RF) -spoiled gradient echo sequences were developed with the aim to produce images with T(1) weighted contrast within short acquisition time. Over the past two decades, this type of sequence has proven to be a robust technique and represents a reliable workhorse in clinical MRI. This study presents an ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21614

    authors: Leupold J,Hennig J,Scheffler K

    更新日期:2008-07-01 00:00:00

  • Decomposition of inflow and blood oxygen level-dependent (BOLD) effects with dual-echo spiral gradient-recalled echo (GRE) fMRI.

    abstract::Image contrast with gradient-recalled echo sequences (GRE) used for fMRI can have both blood oxygen level-dependent (BOLD) and inflow components, and the latter is often undesirable. A dual-echo technique can be used to differentiate these mechanisms, because modulation of signal from inflow is common to both echoes, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350306

    authors: Glover GH,Lemieux SK,Drangova M,Pauly JM

    更新日期:1996-03-01 00:00:00

  • Perfusion-based event-related functional MRI.

    abstract::Perfusion-based event-related functional MRI was performed by measuring flow-sensitive alternating inversion recovery (FAIR) signal changes during repeated single-trial, short visual stimulation (250 msec). In the visual cortex activation area, the blood flow increases immediately after the stimulus, reaches the maxim...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199912)42:6<1011::aid-mrm3

    authors: Liu HL,Gao JH

    更新日期:1999-12-01 00:00:00

  • One-minute whole-brain magnetization transfer ratio imaging with intrinsic B1-correction.

    abstract:PURPOSE:Magnetization transfer ratio (MTR) histograms are used widely for the assessment of diffuse pathological changes in the brain. For broad clinical application, MTR scans should not only be fast, but confounding factors should also be minimized for high reproducibility. To this end, a 1-minute whole-brain spiral ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28618

    authors: Afshari R,Santini F,Heule R,Meyer CH,Pfeuffer J,Bieri O

    更新日期:2020-12-08 00:00:00

  • RF heating measurement using MR thermometry and field monitoring: Methodological considerations and first in vivo results.

    abstract:PURPOSE:A MR thermometry (MRT) method with field monitoring is proposed to improve the measurement of small temperature variations induced in brain MRI exams. METHODS:MR thermometry experiments were performed at 7 Tesla with concurrent field monitoring and RF heating. Images were reconstructed with nominal k-space tra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28501

    authors: Le Ster C,Mauconduit F,Mirkes C,Bottlaender M,Boumezbeur F,Djemai B,Vignaud A,Boulant N

    更新日期:2021-03-01 00:00:00

  • Real-time imaging of two-dimensional cardiac strain using a harmonic phase magnetic resonance imaging (HARP-MRI) pulse sequence.

    abstract::The harmonic phase (HARP) method provides automatic and rapid analysis of tagged magnetic resonance (MR) images for quantification and visualization of myocardial strain. In this article, the development and implementation of a pulse sequence that acquires HARP images in real time are described. In this pulse sequence...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.10509

    authors: Sampath S,Derbyshire JA,Atalar E,Osman NF,Prince JL

    更新日期:2003-07-01 00:00:00

  • Unifying linear prior-information-driven methods for accelerated image acquisition.

    abstract::In the ongoing quest for faster imaging and higher spatial resolution, several methods have been developed to speed up data acquisition by incorporating prior information about the object being imaged. This study shows that many of these methods can be integrated into a single common equation. The unified framework pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1242

    authors: Tsao J,Behnia B,Webb AG

    更新日期:2001-10-01 00:00:00

  • Removal of phase artifacts from fMRI data using a Stockwell transform filter improves brain activity detection.

    abstract::A novel and automated technique is described for removing fMRI image artifacts resulting from motion outside of the imaging field of view. The technique is based on the Stockwell transform (ST), a mathematical operation that provides the frequency content at each time point within a time-varying signal. Using this tec...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10681

    authors: Goodyear BG,Zhu H,Brown RA,Mitchell JR

    更新日期:2004-01-01 00:00:00