Echo-planar time course MRI of cat brain oxygenation changes.

Abstract:

:When deoxygenated, blood behaves as an effective susceptibility contrast agent. Changes in brain oxygenation can be monitored using gradient-echo echo-planar imaging. With this technique, difference images also demonstrate that blood oxygenation is increased during periods of recovery from respiratory challenge.

journal_name

Magn Reson Med

authors

Turner R,Le Bihan D,Moonen CT,Despres D,Frank J

doi

10.1002/mrm.1910220117

subject

Has Abstract

pub_date

1991-11-01 00:00:00

pages

159-66

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

22

pub_type

杂志文章
  • Spin-echo MRI using pi/2 and pi hyperbolic secant pulses.

    abstract::Frequency-modulated (FM) pulses have practical advantages for spin-echo experiments, such as the ability to produce a broadband pi rotation, with an inhomogeneous radiofrequency (RF) field. However, such use leads to a nonlinear phase of the transverse magnetization, which is why FM pulses like the hyperbolic secant (...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21822

    authors: Park JY,Garwood M

    更新日期:2009-01-01 00:00:00

  • Evaluation of motion and realignment for functional magnetic resonance imaging in real time.

    abstract::Functional magnetic resonance imaging in real time is an emerging tool for the assessment of dynamic changes in brain activation. The short response latency (tens of seconds) renders the technique more sensitive to motion artifacts. Motion correction in real time requires computationally efficient algorithms which can...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200101)45:1<167::aid-mrm1023>3.0

    authors: Mathiak K,Posse S

    更新日期:2001-01-01 00:00:00

  • 3D-multi-spectral T2 mapping near metal implants.

    abstract:PURPOSE:Due to host-mediated adverse reaction to metallic debris, there is an increasing need for noninvasive assessment of the soft tissue surrounding large joint arthroplasties. Quantitative T 2 ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27744

    authors: Bhave S,Koff MF,Sivaram Kaushik S,Potter HG,Koch KM

    更新日期:2019-08-01 00:00:00

  • Flow-gated phase-contrast MRI using radial acquisitions.

    abstract::Phase-contrast (PC) MRI is a noninvasive method for imaging blood and tissue velocity. PC experiments are typically segmented into many cardiac cycles in order to obtain sufficient spatial and temporal resolution, and thus require a gating signal to properly combine the data from multiple cardiac cycles. Although the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20187

    authors: Thompson RB,McVeigh ER

    更新日期:2004-09-01 00:00:00

  • Mathematical optimization of contrast concentration for T1-weighted spoiled gradient echo imaging.

    abstract:PURPOSE:To develop and validate closed form mathematical expressions that predict the optimal contrast agent concentration for the maximum T1-weighted spoiled gradient echo (SGRE) signal. THEORY AND METHODS:Gadolinium and iron-based contrast agents can have significant transverse relaxivity that leads to signal dropou...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25744

    authors: Reeder SB,Smith MR,Hernando D

    更新日期:2016-04-01 00:00:00

  • Use of high temperature superconductor in a receiver coil for magnetic resonance imaging.

    abstract::A planar YBa2Cu3Ox (YBCO) coil has been used as a pick-up coil in a nuclear magnetic resonance imager. It was found that the quality factor (Q) of the YBCO coil was greater than its copper counterpart by approaching 50% even in a field of 0.15 T. The Q of the copper coil at 77 K and in a field of 0.15 T was 1200 while...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910200218

    authors: Hall AS,Alford NM,Button TW,Gilderdale DJ,Gehring KA,Young IR

    更新日期:1991-08-01 00:00:00

  • Oxygen-sensitive contrast in blood for steady-state free precession imaging.

    abstract::Steady-state free precession (SSFP) methods have gained widespread recognition for their ability to provide fast scans at high signal-to-noise ratio. This paper demonstrates that such methods are also capable of reflecting functional information, particularly blood oxygenation state. It is well known that SSFP signals...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20393

    authors: Dharmakumar R,Hong J,Brittain JH,Plewes DB,Wright GA

    更新日期:2005-03-01 00:00:00

  • Evaluation of multicontrast MRI including fat suppression and inversion recovery spin echo for identification of intra-plaque hemorrhage and lipid core in human carotid plaque using the mahalanobis distance measure.

    abstract::Intra-plaque hemorrhage (IPH) and lipid core, characteristics of rupture prone carotid plaques, are often visualized in vivo with MRI using T1 weighted gradient and spin echo, respectively. Increasing magnetic field strength may help to identify IPH and lipid core better. As a proof of concept, automatic segmentation ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23191

    authors: te Boekhorst BC,van 't Klooster R,Bovens SM,van de Kolk KW,Cramer MJ,van Oosterhout MF,Doevendans PA,van der Geest RJ,Pasterkamp G,van Echteld CJ

    更新日期:2012-06-01 00:00:00

  • Phase-labeled reference EPI for frequency-segmented inhomogeneity corrections (PREFICS).

    abstract:PURPOSE:To develop a method to correct for geometric distortions in non-Cartesian echo planar imaging using data acquired in a fast prescan. METHODS:Echo planar images were obtained using a non-Cartesian density weighted k-space trajectory. In contrast to linear Cartesian acquisition, distortions arising in non-Cartes...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24737

    authors: Zeller M,Müller A,Hahn D,Köstler H

    更新日期:2014-03-01 00:00:00

  • Fast diffusion tensor imaging and tractography of the whole cervical spinal cord using point spread function corrected echo planar imaging.

    abstract::Diffusion tensor imaging has been used in a number of spinal cord studies, but severe distortions caused by susceptibility induced field inhomogeneities limit its applicability to investigate small volumes within acceptable acquisition times. A way to evaluate image distortions is to map the point spread function of t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24235

    authors: Lundell H,Barthelemy D,Biering-Sørensen F,Cohen-Adad J,Nielsen JB,Dyrby TB

    更新日期:2013-01-01 00:00:00

  • Rapid whole-brain gray matter imaging using single-slab three-dimensional dual-echo fast spin echo: A feasibility study.

    abstract:PURPOSE:To achieve rapid, high resolution whole-brain gray matter (GM) imaging by developing a novel, single-slab three-dimensional dual-echo fast-spin-echo pulse sequence and GM-selective reconstruction. METHODS:Unlike conventional GM imaging that uses time-consuming double-inversion-recovery preparation, the propose...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26910

    authors: Lee H,Kim EY,Sohn CH,Park J

    更新日期:2017-11-01 00:00:00

  • Total brain N-acetylaspartate concentration in normal, age-grouped females: quantitation with non-echo proton NMR spectroscopy.

    abstract::The intra-individual and inter-individual variations of the global N-acetylaspartate (NAA) concentration were measured in a cohort of five 42+/-5 year-old normal females. The total NAA signal from the whole head was obtained with non-localized non-echo proton spectroscopy (1H-MRS) and converted into absolute mole amou...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.1910400506

    authors: Gonen O,Viswanathan AK,Catalaa I,Babb J,Udupa J,Grossman RI

    更新日期:1998-11-01 00:00:00

  • SSFP signal with finite RF pulses.

    abstract::The theoretical description of steady state free precession (SSFP) sequences is generally well accepted and unquestioned, although it is based on instantaneously acting radiofrequency (RF) pulses. In practice, however, all excitation processes are finite, thereby questioning the overall validity of the common SSFP sig...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22116

    authors: Bieri O,Scheffler K

    更新日期:2009-11-01 00:00:00

  • Three-dimensional reconstruction of limited-view projections for contrast-enhanced magnetic resonance angiography at high temporal and spatial resolution.

    abstract::The feasibility of reconstructing three-dimensional (3D) MRI data sets from limited-view projections is investigated in phantom and in vivo animal studies to improve the temporal resolution of magnetic resonance angiography without sacrificing spatial resolution. Thirty-two pairs of orthogonal biplane projections are ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20727

    authors: Huang Y,Gurr D,Wright GA

    更新日期:2006-01-01 00:00:00

  • Hyperpolarized 13C MRI of the pulmonary vasculature and parenchyma.

    abstract::The study of lung perfusion in normal and diseased subjects is of great interest to physiologists and physicians. In this work we demonstrate the application of a liquid-phase hyperpolarized (HP) carbon-13 ((13)C) tracer to magnetic resonance imaging (MRI) of the pulmonary vasculature and pulmonary perfusion in a porc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21168

    authors: Ishii M,Emami K,Kadlecek S,Petersson JS,Golman K,Vahdat V,Yu J,Cadman RV,MacDuffie-Woodburn J,Stephen M,Lipson DA,Rizi RR

    更新日期:2007-03-01 00:00:00

  • Free-breathing volumetric fat/water separation by combining radial sampling, compressed sensing, and parallel imaging.

    abstract:PURPOSE:Conventional fat/water separation techniques require that patients hold breath during abdominal acquisitions, which often fails and limits the achievable spatial resolution and anatomic coverage. This work presents a novel approach for free-breathing volumetric fat/water separation. METHODS:Multiecho data are ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26392

    authors: Benkert T,Feng L,Sodickson DK,Chandarana H,Block KT

    更新日期:2017-08-01 00:00:00

  • Impact of transcytolemmal water exchange on estimates of tissue microstructural properties derived from diffusion MRI.

    abstract:PURPOSE:To investigate the influence of transcytolemmal water exchange on estimates of tissue microstructural parameters derived from diffusion MRI using conventional PGSE and IMPULSED methods. METHODS:Computer simulations were performed to incorporate a broad range of intracellular water life times τin (50-∞ ms), cel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26309

    authors: Li H,Jiang X,Xie J,Gore JC,Xu J

    更新日期:2017-06-01 00:00:00

  • Variable flip angle 3D-GRASE for high resolution fMRI at 7 tesla.

    abstract:PURPOSE:To evaluate the use of variable flip angle refocusing pulse trains in single-shot three-dimensional gradient and spin-echo (3D-GRASE) to reduce blurring and increase the spatial coverage for high spatial resolution T2 -weighted functional MRI at 7 Tesla. METHODS:Variable flip angle refocusing schemes in 3D-GRA...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25979

    authors: Kemper VG,De Martino F,Yacoub E,Goebel R

    更新日期:2016-09-01 00:00:00

  • High resolution quantitative relaxation and diffusion MRI of three different experimental brain tumors in rat.

    abstract::The potential of quantitative parameter images of the relaxation times T1 and T2, the proton density rho and the apparent diffusion coefficient (ADC) to characterize three different experimental rat brain tumors (F98 glioma, RN6 Schwannoma, and E376 neuroblastoma) was studied. All parameter values, as determined in hi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340608

    authors: Eis M,Els T,Hoehn-Berlage M

    更新日期:1995-12-01 00:00:00

  • Extended graphical model for analysis of dynamic contrast-enhanced MRI.

    abstract::Kinetic analysis with mathematical models has become increasingly important to quantify physiological parameters in computed tomography (CT), positron emission tomography (PET), and dynamic contrast-enhanced MRI (DCE-MRI). The modified Kety/Tofts model and the graphical (Patlak) model have been widely applied to DCE-M...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22819

    authors: Chen H,Li F,Zhao X,Yuan C,Rutt B,Kerwin WS

    更新日期:2011-09-01 00:00:00

  • Lateral geniculate activations can be detected using intersubject averaging and fMRI.

    abstract::Applications of fMRI in functional brain imaging are mainly confined to single subject designs, prohibiting the assessment of subject or group by condition interactions (i.e., differential activations) or areas of conjoint activation. In this paper a framework for fMRI group designs, using statistical parametric mappi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380502

    authors: Büchel C,Turner R,Friston K

    更新日期:1997-11-01 00:00:00

  • Robust abdominal imaging with incomplete breath-holds.

    abstract:PURPOSE:Breath-holding is an established strategy for reducing motion artifacts in abdominal imaging. However, the breath-holding capabilities of patients are often overstrained by scans with large coverage and high resolution. In this work, a new strategy for coping with resulting incomplete breath-holds in abdominal ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24829

    authors: Gdaniec N,Eggers H,Börnert P,Doneva M,Mertins A

    更新日期:2014-05-01 00:00:00

  • Assessing transneuronal dysfunction utilizing manganese-enhanced MRI (MEMRI).

    abstract::In this study we utilized manganese-enhanced MRI (MEMRI) to evaluate the in vivo transneuronal efficiency of manganese ion (Mn(2+)) movement as a means to assess overall changes in neuronal function. We designated this extension the manganese transfer index (MTI) value. To evaluate the MTI value as an index of transne...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21648

    authors: Serrano F,Deshazer M,Smith KD,Ananta JS,Wilson LJ,Pautler RG

    更新日期:2008-07-01 00:00:00

  • Direction-averaged diffusion-weighted MRI signal using different axisymmetric B-tensor encoding schemes.

    abstract:PURPOSE:It has been shown, theoretically and in vivo, that using the Stejskal-Tanner pulsed-gradient, or linear tensor encoding (LTE), and in tissue exhibiting a "stick-like" diffusion geometry, the direction-averaged diffusion-weighted MRI signal at high b-values ( ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28191

    authors: Afzali M,Aja-Fernández S,Jones DK

    更新日期:2020-09-01 00:00:00

  • Voxelwise analysis of simultaneously acquired and spatially correlated 18 F-fluorodeoxyglucose (FDG)-PET and intravoxel incoherent motion metrics in breast cancer.

    abstract:PURPOSE:Diffusion-weighted imaging (DWI) and 18 F-fluorodeoxyglucose-positron emission tomography (18 F-FDG-PET) independently correlate with malignancy in breast cancer, but the relationship between their structural and metabolic metrics is not completely understood. This study spatially correlates diffusion, perfusio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26505

    authors: Ostenson J,Pujara AC,Mikheev A,Moy L,Kim SG,Melsaether AN,Jhaveri K,Adams S,Faul D,Glielmi C,Geppert C,Feiweier T,Jackson K,Cho GY,Boada FE,Sigmund EE

    更新日期:2017-09-01 00:00:00

  • Parallel transmit capability of various RF transmit elements and arrays at 7T MRI.

    abstract:PURPOSE:In this work, 22 configurations for remote radiofrequency (RF) coil arrays consisting of different transmit element designs for 7 Tesla (T) ultrahigh-field MRI are compared by numerical simulations. METHODS:Investigated transmit RF element types are rectangular loops, micro striplines, micro striplines with me...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26704

    authors: Rietsch SHG,Orzada S,Bitz AK,Gratz M,Ladd ME,Quick HH

    更新日期:2018-02-01 00:00:00

  • Pattern recognition analysis of 1H NMR spectra from perchloric acid extracts of human brain tumor biopsies.

    abstract::Pattern recognition techniques (factor analysis and neural networks) were used to investigate and classify human brain tumors based on the 1H NMR spectra of chemically extracted biopsies (n = 118). After removing information from lactate (because of variable ischemia times), unsupervised learning suggested that the sp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390604

    authors: Maxwell RJ,Martínez-Pérez I,Cerdán S,Cabañas ME,Arús C,Moreno A,Capdevila A,Ferrer E,Bartomeus F,Aparicio A,Conesa G,Roda JM,Carceller F,Pascual JM,Howells SL,Mazucco R,Griffiths JR

    更新日期:1998-06-01 00:00:00

  • RACER-GRASP: Respiratory-weighted, aortic contrast enhancement-guided and coil-unstreaking golden-angle radial sparse MRI.

    abstract:PURPOSE:To develop and evaluate a novel dynamic contrast-enhanced imaging technique called RACER-GRASP (Respiratory-weighted, Aortic Contrast Enhancement-guided and coil-unstReaking Golden-angle RAdial Sparse Parallel) MRI that extends GRASP to include automatic contrast bolus timing, respiratory motion compensation, a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27002

    authors: Feng L,Huang C,Shanbhogue K,Sodickson DK,Chandarana H,Otazo R

    更新日期:2018-07-01 00:00:00

  • Eddy current correction in diffusion-weighted imaging using pairs of images acquired with opposite diffusion gradient polarity.

    abstract::In echo-planar-based diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI), the evaluation of diffusion parameters such as apparent diffusion coefficients and anisotropy indices is affected by image distortions that arise from residual eddy currents produced by the diffusion-sensitizing gradients. Correc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10690

    authors: Bodammer N,Kaufmann J,Kanowski M,Tempelmann C

    更新日期:2004-01-01 00:00:00

  • Spectral baseline correction using CLEAN.

    abstract::Baseline distortion in NMR spectroscopy, caused by the "dead time" between signal excitation and detection, makes quantitative interpretation difficult and is aesthetically displeasing. Here the use of the CLEAN algorithm for deconvolving the effect of signal dead time to produce a distortionless baseline is discussed...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910130113

    authors: McKinnon GC,Burger C,Boesiger P

    更新日期:1990-01-01 00:00:00