Relative concentrations of proton MR visible neurochemicals in gray and white matter in human brain.

Abstract:

:The relative distributions of N-acetylaspartate (NAA) + N-acetylaspartylglutamate (NAAG), creatine + phosphocreatine (Cr/PCr), and choline (Cho) in the gray and white matter of human brain were determined by utilizing proton magnetic resonance spectroscopic imaging (SI). The SI data was processed using an automated spectroscopic image processing algorithm, and image segmentation was performed using a supervised technique. Linear regression analysis indicated that the NAA + NAAG (2.01 ppm) and Cr/PCr (3.02 ppm) peaks are greater in gray matter compared with white matter. The large intersubject variation observed in the Cho (3.20 ppm) resonance prevented the assessment of its regional distribution with confidence.

journal_name

Magn Reson Med

authors

Doyle TJ,Bedell BJ,Narayana PA

doi

10.1002/mrm.1910330603

subject

Has Abstract

pub_date

1995-06-01 00:00:00

pages

755-9

issue

6

eissn

0740-3194

issn

1522-2594

journal_volume

33

pub_type

杂志文章
  • SMS-HSL: Simultaneous multislice aliasing separation exploiting hankel subspace learning.

    abstract:PURPOSE:To develop a novel, simultaneous multislice reconstruction method that exploits Hankel subspace learning (SMS-HSL) for aliasing separation in the slice direction. METHODS:An SMS signal model with the Hankel-structured matrix was proposed. To efficiently suppress interslice leakage artifacts from a signal subsp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26527

    authors: Park S,Park J

    更新日期:2017-10-01 00:00:00

  • Projection reconstruction MR imaging using FOCUSS.

    abstract::The focal underdetermined system solver (FOCUSS) was originally designed to obtain sparse solutions by successively solving quadratic optimization problems. This article adapts FOCUSS for a projection reconstruction MR imaging problem to obtain high resolution reconstructions from angular under-sampled radial k-space ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21202

    authors: Ye JC,Tak S,Han Y,Park HW

    更新日期:2007-04-01 00:00:00

  • Utilization of an intra-oral diamagnetic passive shim in functional MRI of the inferior frontal cortex.

    abstract::Due to the presence of gross magnetic susceptibility artifacts, functional MRI (fMRI) has proved problematic in studies of the human inferior frontal cortex (IFC). There is a strong desire, therefore, to employ techniques that mitigate susceptibility artifacts in the IFC while preserving the imaging parameters of an f...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10626

    authors: Wilson JL,Jezzard P

    更新日期:2003-11-01 00:00:00

  • Perfusion-weighted imaging of interictal hypoperfusion in temporal lobe epilepsy using FAIR-HASTE: comparison with H(2)(15)O PET measurements.

    abstract::To detect perfusion abnormalities in areas of high magnetic susceptibility in the brain, an arterial spin-labeling MRI technique utilizing flow-sensitive alternating inversion recovery (FAIR) and half-Fourier single shot turbo spin-echo (HASTE) for spin preparation and image acquisition, respectively, was developed. I...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200103)45:3<431::aid-mrm1056>3.0

    authors: Liu HL,Kochunov P,Hou J,Pu Y,Mahankali S,Feng CM,Yee SH,Wan YL,Fox PT,Gao JH

    更新日期:2001-03-01 00:00:00

  • Free breathing lung T1 mapping using image registration in patients with idiopathic pulmonary fibrosis.

    abstract:PURPOSE:To assess the use of image registration for correcting respiratory motion in free breathing lung T1 mapping acquisition in patients with idiopathic pulmonary fibrosis (IPF). THEORY AND METHODS:The method presented used image registration to synthetic images during postprocessing to remove respiratory motion. S...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28342

    authors: Saunders LC,Eaden JA,Bianchi SM,Swift AJ,Wild JM

    更新日期:2020-12-01 00:00:00

  • High-resolution 3D proton spectroscopic imaging of the human brain at 3 T: SNR issues and application for anatomy-matched voxel sizes.

    abstract::In a systematic study on the interdependence of linewidth, signal-to-noise ratio (SNR), and spatial resolution in 3D proton spectroscopic imaging ((1)H-SI) at 3 T, we demonstrate reduced linewidths with increased spatial resolution due to reduced magnetic inhomogeneity within the brain. High-precision quantitative dat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10377

    authors: Gruber S,Mlynárik V,Moser E

    更新日期:2003-02-01 00:00:00

  • Stability assessment of gadolinium complexes by P-31 and H-1 relaxometry.

    abstract::Longitudinal P-31 relaxation rate enhancements of phosphate groups have been measured at pH 7-7.2 and 310 degrees K on aqueous solutions containing adenosine triphosphate (ATP), phosphocreatine (PCr), inorganic phosphate (Pi) and some lanthanide complexes (Gd-DOTA, Gd-HPDO3A, Gd-DO3A, Gd-DTPA, Gd-DTPA-BMA). The macroc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310413

    authors: Vander Elst L,Van Haverbeke Y,Goudemant JF,Muller RN

    更新日期:1994-04-01 00:00:00

  • NMR changes in experimental allergic encephalomyelitis: NMR changes precede clinical and pathological events.

    abstract::In guinea pigs immunized with myelin basic protein (MBP) in complete Freund's adjuvant, experimental allergic encephalomyelitis (EAE) shows a characteristic clinical and pathological course. This study characterized the proton nuclear magnetic resonance (NMR) properties of the central nervous system prior to the onset...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050203

    authors: O'Brien JT,Noseworthy JH,Gilbert JJ,Karlik SJ

    更新日期:1987-08-01 00:00:00

  • Investigation and modeling of magnetization transfer effects in two-dimensional multislice turbo spin echo sequences with low constant or variable flip angles at 3 T.

    abstract::Magnetization transfer effects represent a major source of contrast in multislice turbo spin echo sequences (TSE)/fast spin echo sequences. Generally, low refocusing flip angles have become common in such MRI sequences, especially to mitigate specific absorption rate problems. Since the strength of magnetization trans...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22145

    authors: Weigel M,Helms G,Hennig J

    更新日期:2010-01-01 00:00:00

  • Multi-echo length and offset VARied saturation (MeLOVARS) method for improved CEST imaging.

    abstract:PURPOSE:The aim of this study was to develop a technique for rapid collection of chemical exchange saturation transfer images with the saturation varied to modulate signal loss transfer and enhance contrast. METHODS:Multi-echo Length and Offset VARied Saturation (MeLOVARS) divides the saturation pulse of length Tsat i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25567

    authors: Song X,Xu J,Xia S,Yadav NN,Lal B,Laterra J,Bulte JW,van Zijl PC,McMahon MT

    更新日期:2015-02-01 00:00:00

  • Rapid whole-brain gray matter imaging using single-slab three-dimensional dual-echo fast spin echo: A feasibility study.

    abstract:PURPOSE:To achieve rapid, high resolution whole-brain gray matter (GM) imaging by developing a novel, single-slab three-dimensional dual-echo fast-spin-echo pulse sequence and GM-selective reconstruction. METHODS:Unlike conventional GM imaging that uses time-consuming double-inversion-recovery preparation, the propose...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26910

    authors: Lee H,Kim EY,Sohn CH,Park J

    更新日期:2017-11-01 00:00:00

  • Sources of functional apparent diffusion coefficient changes investigated by diffusion-weighted spin-echo fMRI.

    abstract::The mechanism behind previously observed changes in the apparent diffusion coefficient (ADC) during brain activation is not well understood. Therefore, we investigated the signal source and spatial specificity of functional magnetic resonance imaging (fMRI) ADC changes systematically in the visual cortex of cats using...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21074

    authors: Jin T,Zhao F,Kim SG

    更新日期:2006-12-01 00:00:00

  • Automatic in-line quantitative myocardial perfusion mapping: Processing algorithm and implementation.

    abstract:PURPOSE:Quantitative myocardial perfusion mapping has advantages over qualitative assessment, including the ability to detect global flow reduction. However, it is not clinically available and remains a research tool. Building upon the previously described imaging sequence, this study presents algorithm and implementat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27954

    authors: Xue H,Brown LAE,Nielles-Vallespin S,Plein S,Kellman P

    更新日期:2020-02-01 00:00:00

  • Designing parallel transmit head coil arrays based on radiofrequency pulse performance.

    abstract:PURPOSE:A new approach to design parallel transmit (pTx) head arrays is proposed that integrates transmit radiofrequency pulse designs with electromagnetic modeling of array coil elements. THEORY AND METHODS:An approach to design pTx head arrays is proposed that finds optimal groupings of a large number of coils into ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28068

    authors: Cao Z,Yan X,Gore JC,Grissom WA

    更新日期:2020-06-01 00:00:00

  • RF heating measurement using MR thermometry and field monitoring: Methodological considerations and first in vivo results.

    abstract:PURPOSE:A MR thermometry (MRT) method with field monitoring is proposed to improve the measurement of small temperature variations induced in brain MRI exams. METHODS:MR thermometry experiments were performed at 7 Tesla with concurrent field monitoring and RF heating. Images were reconstructed with nominal k-space tra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28501

    authors: Le Ster C,Mauconduit F,Mirkes C,Bottlaender M,Boumezbeur F,Djemai B,Vignaud A,Boulant N

    更新日期:2021-03-01 00:00:00

  • Analysis and correction of biases in cross-relaxation MRI due to biexponential longitudinal relaxation.

    abstract:PURPOSE:Cross-relaxation imaging (CRI) is a family of quantitative magnetization transfer techniques that utilize images obtained with off-resonance saturation and longitudinal relaxation rate (R1) maps reconstructed by the variable flip angle (VFA) method. It was demonstrated recently that a significant bias in an app...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24677

    authors: Mossahebi P,Yarnykh VL,Samsonov A

    更新日期:2014-02-01 00:00:00

  • Simple measurement of scanner stability for functional NMR imaging of activation in the brain.

    abstract::Functional MR imaging (fMRI) of activation in the brain is one of the more demanding applications required of an NMR imaging instrument. Since the signal changes in activation imaging are quite small, any instrumental variations can easily compromise the fMRI contrast. The authors describe a simple method for measurin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360422

    authors: Weisskoff RM

    更新日期:1996-10-01 00:00:00

  • Improved quantification of myocardial blood flow using highly constrained back projection reconstruction.

    abstract:PURPOSE:To improve quantification of myocardial blood flow using a fast T1 mapping technique using highly constrained back projection reconstruction (HYPR)-accelerated acquisition. METHODS:A major source of error in the measurement of myocardial blood flow (MBF) using MRI is the nonlinear relationship between image si...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24958

    authors: Chen D,Sharif B,Dharmakumar R,Thomson LE,Bairey Merz CN,Berman DS,Li D

    更新日期:2014-09-01 00:00:00

  • Sensitivity enhancement and reduction of Gibbs artifact in T2-weighted imaging using variable tip angle excitation.

    abstract::Introduction of a Gaussian weighting function into the phase encoding of the spin-echo imaging method via variable tip angle excitation, with concomitant optimization of the recycle delay, is shown to increase the sensitivity of T2-weighted imaging by up to 40%. In addition, the Gibbs artifact associated with sharp bo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910210216

    authors: Webb AG,Clarkson RB

    更新日期:1991-10-01 00:00:00

  • Comparison of prospective head motion correction with NMR field probes and an optical tracking system.

    abstract:PURPOSE:The aim of this study was to compare prospective head motion correction and motion tracking abilities of two tracking systems: Active NMR field probes and a Moiré phase tracking camera system using an optical marker. METHODS:Both tracking systems were used simultaneously on human subjects. The prospective head...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27343

    authors: Eschelbach M,Aghaeifar A,Bause J,Handwerker J,Anders J,Engel EM,Thielscher A,Scheffler K

    更新日期:2019-01-01 00:00:00

  • An evaluation of the effect of fasting on the exercise-induced changes in pH and Pi/PCr from skeletal muscle.

    abstract::The changes in the response of skeletal muscle to maximal dynamic exercise were investigated in going from a fasted state to a refed state by means of 31P NMR spectroscopy. It was found that in the fasted state, exercise-induced changes in Pi/PCr and in pH were both inhibited, in comparison with those in the refed sta...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030616

    authors: Lunt JA,Allen PS,Brauer M,Swinamer D,Treiber EO,Belcastro A,Eccles R,King EG

    更新日期:1986-12-01 00:00:00

  • The field dependence of NMR imaging. II. Arguments concerning an optimal field strength.

    abstract::Some of the factors involved in the choice of field strength for NMR imaging are examined. The influences of relaxation times and chemical shift upon image quality and signal-to-noise ratio are highlighted, and power deposition is introduced as a significant factor which may limit the flexibility and information avail...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030509

    authors: Hoult DI,Chen CN,Sank VJ

    更新日期:1986-10-01 00:00:00

  • Calcium-induced structural changes of cartilage proteoglycans studied by H NMR relaxometry and diffusion measurements.

    abstract::1H transverse nuclear magnetic relaxation times (T2) and self-diffusion coefficients (SDCs) of water were measured in isolated proteoglycan aggregates from pig articular cartilage. The influence of varying osmotic pressure, as well as of different calcium concentrations, on the samples was investigated. Due to a struc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199901)41:1<43::aid-mrm8>3

    authors: Werner A,Gründer W

    更新日期:1999-01-01 00:00:00

  • Multi-band MR fingerprinting (MRF) ASL imaging using artificial-neural-network trained with high-fidelity experimental data.

    abstract:PURPOSE:We aim to leverage the power of deep-learning with high-fidelity training data to improve the reliability and processing speed of hemodynamic mapping with MR fingerprinting (MRF) arterial spin labeling (ASL). METHODS:A total of 15 healthy subjects were studied on a 3T MRI. Each subject underwent 10 runs of a m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28560

    authors: Fan H,Su P,Huang J,Liu P,Lu H

    更新日期:2021-04-01 00:00:00

  • Application of phase rotation to STRESS localization scheme at 3 T.

    abstract:PURPOSE:Application of phase rotation to the STRESS (=STEAM+PRESS) localization scheme, to shorten echo time, minimize J-coupling dephasing and estimate B1+ inhomogeneity. STRESS (=STEAM + PRESS) simultaneously refocuses and acquires the double spin echo (SE123 ) and stimulated echo (STE- ) pathways, combining PRESS-li...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26911

    authors: Volovyk O,Tal A

    更新日期:2018-05-01 00:00:00

  • Implementation of vascular-space-occupancy MRI at 7T.

    abstract::Vascular-space-occupancy (VASO) MRI exploits the difference between blood and tissue T1 to null blood signal and measure cerebral blood volume changes using the residual tissue signal. VASO imaging is more difficult at higher field because of sensitivity loss due to the convergence of tissue and blood T1 values and in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24334

    authors: Hua J,Jones CK,Qin Q,van Zijl PC

    更新日期:2013-04-01 00:00:00

  • Effects of the acoustic noise of the gradient systems on fMRI: a study on auditory, motor, and visual cortices.

    abstract::MR acoustic, or sound, noise due to gradient pulsing has been one of the problems in MRI, both in patient scanning as well as in many areas of psychiatric and neuroscience research, such as brain fMRI. Especially in brain fMRI, sound noise is one of the serious noise sources that obscures the small signals obtainable ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390224

    authors: Cho ZH,Chung SC,Lim DW,Wong EK

    更新日期:1998-02-01 00:00:00

  • Improved myocardial tagging contrast.

    abstract::Myocardial tagging is a new noninvasive MRI method that allows the study of myocardial motion with high accuracy. However, with conventional tagging techniques tagging contrast is impaired at later heart phases due to longitudinal relaxation. An improved method, called Complementary SPAtial Modulation of Magnetization...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300207

    authors: Fischer SE,McKinnon GC,Maier SE,Boesiger P

    更新日期:1993-08-01 00:00:00

  • Reduction of resonant RF heating in intravascular catheters using coaxial chokes.

    abstract::The incorporation of RF coils into the tips of intravascular devices has been shown to enable the localization of catheters and guidewires under MR guidance. Furthermore, such coils can be used for endoluminal imaging. The long cable required to connect the coil with the scanner input inadvertently acts as a dipole an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200004)43:4<615::aid-mrm19

    authors: Ladd ME,Quick HH

    更新日期:2000-04-01 00:00:00

  • Improved large tip angle parallel transmission pulse design through a perturbation analysis of the Bloch equation.

    abstract::Parallel transmission has emerged as an efficient means for implementing multidimensional spatially selective radiofrequency excitation pulses. To date, most theoretical and experimental work on parallel transmission radiofrequency (RF) pulse design is based on the small-tip-angle approximation to the Bloch equation. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22827

    authors: Zheng H,Zhao T,Qian Y,Ibrahim TS,Boada FE

    更新日期:2011-09-01 00:00:00