Generalization of intravoxel incoherent motion model by introducing the notion of continuous pseudodiffusion variable.

Abstract:

PURPOSE:A generalized intravoxel incoherent motion (IVIM) model, called the GIVIM, was proposed to better account for complex perfusion present in the tissues having various vessels and flow regimes, such as the liver. THEORY AND METHODS:The notions of continuous pseudodiffusion variable as well as perfusion fraction density function were introduced to describe the presence of multiple perfusion components in a voxel. The mean and standard deviation of Gaussian perfusion fraction density function were then used to define two new parameters, the mean pseudodiffusivity ( D¯) and pseudodiffusion dispersion (σ). The GIVIM model was evaluated by testing whether or not it can reflect hepatic perfusion difference caused by flow-compensated imaging sequences having different diffusion times. Also, D¯ was compared with D* in the standard IVIM model. RESULTS:The values of both D* and D¯ decreased after flow compensation and further decreased when shortening diffusion time. D¯ exhibited reduced variance in comparison with D*. In addition, σ also showed its sensitivity to hepatic perfusion difference caused by the flow-compensated imaging sequences. CONCLUSION:The GIVIM model has the ability to better describe multicomponent perfusion without lengthening acquisition time and knowing in advance the number and/or the variety of perfusion components. Magn Reson Med 76:1594-1603, 2016. © 2015 International Society for Magnetic Resonance in Medicine.

journal_name

Magn Reson Med

authors

Kuai ZX,Liu WY,Zhang YL,Zhu YM

doi

10.1002/mrm.26064

subject

Has Abstract

pub_date

2016-11-01 00:00:00

pages

1594-1603

issue

5

eissn

0740-3194

issn

1522-2594

journal_volume

76

pub_type

杂志文章
  • Iterative Next-Neighbor Regridding (INNG): improved reconstruction from nonuniformly sampled k-space data using rescaled matrices.

    abstract::The reconstruction of MR images from nonrectilinearly sampled data is complicated by the fact that the inverse 2D Fourier transform (FT) cannot be performed directly on the acquired k-space data set. k-Space gridding is commonly used because it is an efficient reconstruction method. However, conventional gridding requ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10692

    authors: Moriguchi H,Duerk JL

    更新日期:2004-02-01 00:00:00

  • Counter rotating current local coils for high-resolution magnetic resonance imaging.

    abstract::A type of local coil (or surface coil) for magnetic resonance imaging and spectroscopy is described in which two circular loops of the same diameter are disposed axially with respect to each other and in which counter rotating currents (CRC) are supported in the two loops. This type of coil has been used for localized...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030412

    authors: Froncisz W,Jesmanowicz A,Kneeland JB,Hyde JS

    更新日期:1986-08-01 00:00:00

  • Machine learning improves classification of preclinical models of pancreatic cancer with chemical exchange saturation transfer MRI.

    abstract:PURPOSE:We sought to assess whether machine learning-based classification approaches can improve the classification of pancreatic tumor models relative to more simplistic analysis methods, using T1 relaxation, CEST, and DCE MRI. METHODS:The T1 relaxation time constants, % CEST at five saturation frequencies, and vascu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27439

    authors: Goldenberg JM,Cárdenas-Rodríguez J,Pagel MD

    更新日期:2019-01-01 00:00:00

  • Parallel excitation for B-field insensitive fat-saturation preparation.

    abstract::Multichannel transmission has the potential to improve many aspects of MRI through a new paradigm in excitation. In this study, multichannel transmission is used to address the effects that variations in B(0) homogeneity have on fat-saturation preparation through the use of the frequency, phase, and amplitude degrees ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23238

    authors: Heilman JA,Derakhshan JD,Riffe MJ,Gudino N,Tkach J,Flask CA,Duerk JL,Griswold MA

    更新日期:2012-08-01 00:00:00

  • Measurement of the blood-brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental concepts.

    abstract::Leakage of Gd-DTPA through a defective blood-brain barrier is measured quantitatively using dynamic MRI scanning, in which repeated scans are made after a bolus injection. Image registration artifacts are minimized; a dose of 0.1 mM/kg and an IR sequence enable enhancement to be measured quantitatively. The triexponen...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170208

    authors: Tofts PS,Kermode AG

    更新日期:1991-02-01 00:00:00

  • Direct imaging of hyperpolarized 129Xe alveolar gas uptake in a mouse model of emphysema.

    abstract::MRI of hyperpolarized (129)Xe dissolved in pulmonary tissues, and blood has the potential to offer a new tool for regional evaluation of pulmonary gas exchange and perfusion; however, the extremely short T2* and low magnetization density make it difficult to acquire the image. In this study, an ultrashort echo-time se...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24452

    authors: Iguchi S,Imai H,Hori Y,Nakajima J,Kimura A,Fujiwara H

    更新日期:2013-07-01 00:00:00

  • SSFP signal with finite RF pulses.

    abstract::The theoretical description of steady state free precession (SSFP) sequences is generally well accepted and unquestioned, although it is based on instantaneously acting radiofrequency (RF) pulses. In practice, however, all excitation processes are finite, thereby questioning the overall validity of the common SSFP sig...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22116

    authors: Bieri O,Scheffler K

    更新日期:2009-11-01 00:00:00

  • Reproducibility of fractional ventilation derived by Fourier decomposition after adjusting for tidal volume with and without an MRI compatible spirometer.

    abstract:PURPOSE:To reduce the influence of tidal volume on fractional ventilation (FV) derived by Fourier decomposition (FD). METHODS:Twelve volunteers were examined on a 1.5 Tesla scanner. Spoiled gradient echo imaging of coronal and sagittal slices of the lung were performed. The tidal volume variations between different ac...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26047

    authors: Voskrebenzev A,Gutberlet M,Becker L,Wacker F,Vogel-Claussen J

    更新日期:2016-11-01 00:00:00

  • Single-Voxel 1 H MR spectroscopy of cerebral nicotinamide adenine dinucleotide (NAD+ ) in humans at 7T using a 32-channel volume coil.

    abstract:PURPOSE:Reliable monitoring of tissue nicotinamide adenine dinucleotide (NAD+ ) concentration may provide insights on its roles in normal and pathological aging. In the present study, we report a 1 H MRS pulse sequence for the in vivo, localized 1 H MRS detection of NAD+ from the human brain. METHODS:Studies were carr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27971

    authors: Bagga P,Hariharan H,Wilson NE,Beer JC,Shinohara RT,Elliott MA,Baur JA,Marincola FM,Witschey WR,Haris M,Detre JA,Reddy R

    更新日期:2020-03-01 00:00:00

  • Diffusion-weighted NMR spectroscopy allows probing of 13C labeling of glutamate inside distinct metabolic compartments in the brain.

    abstract::In the present work, diffusion-weighted (DW)-NMR spectroscopy of glutamate was performed during a (13)C-labeled glucose infusion in monkey brain (six experiments). It is shown that glutamate (13)C labeling occurs significantly faster at higher diffusion weightings-slightly for glutamate in position C4, and more marked...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21661

    authors: Valette J,Chaumeil M,Guillermier M,Bloch G,Hantraye P,Lebon V

    更新日期:2008-08-01 00:00:00

  • Apparent diffusion coefficients of the five major metabolites measured in the human brain in vivo at 3T.

    abstract:PURPOSE:To measure the apparent diffusion coefficients (ADC) of five main metabolites in the human brain at 3T with PRESS and STEAM, avoiding measurement biases because of cross-terms. Cross-terms arise from interactions between slice-selection and spoiler gradients in the localized spectroscopy sequence and the diffus...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26969

    authors: Deelchand DK,Auerbach EJ,Marjańska M

    更新日期:2018-06-01 00:00:00

  • DREAM--a novel approach for robust, ultrafast, multislice B₁ mapping.

    abstract::A novel multislice B₁-mapping method dubbed dual refocusing echo acquisition mode is proposed, able to cover the whole transmit coil volume in only one second, which is more than an order of magnitude faster than established approaches. The dual refocusing echo acquisition mode technique employs a stimulated echo acqu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24158

    authors: Nehrke K,Börnert P

    更新日期:2012-11-01 00:00:00

  • Low peak power multiband spokes pulses for B1 (+) inhomogeneity-compensated simultaneous multislice excitation in high field MRI.

    abstract:PURPOSE:To design low peak and integrated power simultaneous multislice excitation radiofrequency pulses with transmit field inhomogeneity compensation in high field MRI. THEORY AND METHODS:The "interleaved greedy and local optimization" algorithm for small-tip-angle spokes pulses is extended to design multiband (MB) ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25455

    authors: Sharma A,Bammer R,Stenger VA,Grissom WA

    更新日期:2015-09-01 00:00:00

  • Reweighted ℓ1 referenceless PRF shift thermometry.

    abstract::Temperature estimation in proton resonance frequency (PRF) shift MR thermometry requires a reference, or pretreatment, phase image that is subtracted from image phase during thermal treatment to yield a phase difference image proportional to temperature change. Referenceless thermometry methods derive a reference phas...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22502

    authors: Grissom WA,Lustig M,Holbrook AB,Rieke V,Pauly JM,Butts-Pauly K

    更新日期:2010-10-01 00:00:00

  • Spin-locking versus chemical exchange saturation transfer MRI for investigating chemical exchange process between water and labile metabolite protons.

    abstract::Chemical exchange saturation transfer (CEST) and spin-locking (SL) experiments were both able to probe the exchange process between protons of nonequivalent chemical environments. To compare the characteristics of the CEST and SL approaches in the study of chemical exchange effects, we performed CEST and SL experiment...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22721

    authors: Jin T,Autio J,Obata T,Kim SG

    更新日期:2011-05-01 00:00:00

  • Electrocardiogram acquisition during MR examinations for patient monitoring and sequence triggering.

    abstract::We have developed a method for measuring the electrocardiogram (ECG) continuously during MR examinations. In contrast to ECG acquisition by wires, our new method is to amplify and convert the ECG into an optical signal directly above the patient's heart. The optical signal is transmitted out of the magnet bore by opti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320416

    authors: Felblinger J,Lehmann C,Boesch C

    更新日期:1994-10-01 00:00:00

  • System identification theory in pharmacokinetic modeling of dynamic contrast-enhanced MRI: influence of contrast injection.

    abstract::Optimization of experimental settings of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), like the contrast administration protocol, is of great importance for reliable quantification of the microcirculatory properties, such as the volume transfer-constant K(trans). Using system identification theory an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21575

    authors: Aerts HJ,van Riel NA,Backes WH

    更新日期:2008-05-01 00:00:00

  • Observing curved flow using RUFIS.

    abstract::The rotating ultra-fast imaging sequence (RUFIS) is used to image spins flowing through the curved portion of a 180 degrees U-tube with a circular cross section and a ratio of inner diameter to curvature diameter of 0.41. A velocity-encoding preparation sequence is used with RUFIS to measure quantitatively the axial v...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199906)41:6<1258::aid-mrm2

    authors: Gach HM,Lowe IJ

    更新日期:1999-06-01 00:00:00

  • Skeletal muscle ¹H MRSI before and after prolonged exercise. I. muscle specific depletion of intramyocellular lipids.

    abstract::Aim of the study was to determine distribution and depletion patterns of intramyocellular lipids (IMCL) in leg muscles before and after two types of standardized endurance exercise. ¹H-magnetic resonance spectroscopic imaging was performed (1) in the thigh of eight-trained cyclists after exercising on an ergometer for...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.24168

    authors: Vermathen P,Saillen P,Boss A,Zehnder M,Boesch C

    更新日期:2012-11-01 00:00:00

  • Real-time interactive MRI-guided cardiac surgery: aortic valve replacement using a direct apical approach.

    abstract::Minimally invasive cardiac surgery requires arresting and emptying of the heart, which compromises visualization of the surgical field. In this feasibility study a novel surgical procedure is demonstrated in which real-time MRI is used to guide the placement of a prosthetic aortic valve in the beating heart via direct...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21044

    authors: McVeigh ER,Guttman MA,Lederman RJ,Li M,Kocaturk O,Hunt T,Kozlov S,Horvath KA

    更新日期:2006-11-01 00:00:00

  • Improved activation maps via the elimination of motion effects through time-domain mixing of data in conventional gradient echo functional MRI.

    abstract::To date, most functional imaging centers have relied on ultrafast imaging approaches such as echo-planar imaging (EPI) techniques for acquiring functional brain activation data. These methods require specialized hardware and are not yet installed widely on clinical MR imagers, thus limiting the application of function...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380417

    authors: Constable RT

    更新日期:1997-10-01 00:00:00

  • In vitro 1H NMR "mapping" of human intervertebral discs.

    abstract::Human intervertebral discs were investigated by 1H NMR in vitro. The measured parameters of samples differently located in discs give the "maps" of discs. The spin-lattice relaxation-time maps show similar structure to dry matter and bound water maps, which might mean the future possibility to detect certain disc proc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030122

    authors: Furó I,Bobest M,Pócsik I,Tompa K

    更新日期:1986-02-01 00:00:00

  • Intracellular bimodal nanoparticles based on quantum dots for high-field MRI at 21.1 T.

    abstract::Multimodal, biocompatible contrast agents for high magnetic field applications represent a new class of nanomaterials with significant potential for tracking of fluorescence and MR in vitro and vivo. Optimized for high-field MR applications-including biomedical imaging at 21.1 T, the highest magnetic field available f...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22441

    authors: Rosenberg JT,Kogot JM,Lovingood DD,Strouse GF,Grant SC

    更新日期:2010-09-01 00:00:00

  • Biexponential diffusion attenuation in various states of brain tissue: implications for diffusion-weighted imaging.

    abstract::Diffusion-weighted single voxel experiments conducted at b-values up to 1 x 10(4) smm-2 yielded biexponential signal attenuation curves for both normal and ischemic brain. The relative fractions of the rapidly and slowly decaying components (f1, f2) are f1 = 0.80 +/- 0.02, f2 = 0.17 +/- 0.02 in healthy adult rat brain...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360607

    authors: Niendorf T,Dijkhuizen RM,Norris DG,van Lookeren Campagne M,Nicolay K

    更新日期:1996-12-01 00:00:00

  • Measurement of tibiofemoral kinematics using highly accelerated 3D radial sampling.

    abstract::This study investigated the use of dynamic, volumetric MRI to measure 3D skeletal motion. Ten healthy subjects were positioned on a MR-compatible knee loading device and instructed to harmonically flex and extend their knee at 0.5 Hz. The device induced active quadriceps loading with knee flexion, similar to the load ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24362

    authors: Kaiser J,Bradford R,Johnson K,Wieben O,Thelen DG

    更新日期:2013-05-01 00:00:00

  • T2 accuracy on a whole-body imager.

    abstract::MR oximetry requires a T2 measurement that is accurate within 5% in vivo. Simple methods are susceptible to signal loss and tend to underestimate T2. Current methods utilize RF pulses or RF cycling patterns that prevent signal loss at each data acquisition. However, using these methods with imperfect pulses, T2 tends ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380512

    authors: Foltz WD,Stainsby JA,Wright GA

    更新日期:1997-11-01 00:00:00

  • Image contrast using the secondary and tertiary eigenvectors in diffusion tensor imaging.

    abstract::Diffusion tensor imaging (DTI) is a new imaging modality that can provide unique information on brain white matter anatomy. Measurements of water diffusion constant along multiple axes are fitted to a tensor model, from which the diffusion anisotropy and dominant fiber orientation can be estimated. Even though the ten...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20767

    authors: Zhang J,van Zijl PC,Mori S

    更新日期:2006-02-01 00:00:00

  • Utilization of an intra-oral diamagnetic passive shim in functional MRI of the inferior frontal cortex.

    abstract::Due to the presence of gross magnetic susceptibility artifacts, functional MRI (fMRI) has proved problematic in studies of the human inferior frontal cortex (IFC). There is a strong desire, therefore, to employ techniques that mitigate susceptibility artifacts in the IFC while preserving the imaging parameters of an f...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10626

    authors: Wilson JL,Jezzard P

    更新日期:2003-11-01 00:00:00

  • Metabolic changes in activated T cells: an NMR study of human peripheral blood lymphocytes.

    abstract::Using NMR spectroscopy, we studied purified, human T lymphocytes in a serum-free medium. Purified cells were entrapped inside agarose beads and induced to proliferate by the mitogens phorbol-12-myristate-13-acetate and ionomycin. T lymphocytes in standard culture and inside agarose beads exhibit comparable viability, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290307

    authors: Bental M,Deutsch C

    更新日期:1993-03-01 00:00:00

  • Quantitative diffusion imaging in implanted human breast tumors.

    abstract::Quantitative diffusion measurements were performed in tumors arising from inoculation of nude mice with two human breast cancer cell lines (MCF7 and T47D) to evaluate the specificity of this technique for characterizing solid tumors. ADC maps were compared to histology and correlated well with gross tumor morphology. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370417

    authors: Maier CF,Paran Y,Bendel P,Rutt BK,Degani H

    更新日期:1997-04-01 00:00:00