Abstract:
:Aim of the study was to determine distribution and depletion patterns of intramyocellular lipids (IMCL) in leg muscles before and after two types of standardized endurance exercise. ¹H-magnetic resonance spectroscopic imaging was performed (1) in the thigh of eight-trained cyclists after exercising on an ergometer for 3 h at 52 ± 8% of maximal speed and (2) in the lower leg of eight-trained runners after exercising on a treadmill for 3 h at 49 ± 3% of maximal workload. Pre-exercise IMCL contents were reduced postexercise in 11 out of 13 investigated upper and lower leg muscles (P < 0.015 for all). A strong linear correlation with a slope of ∼0.5 between pre-exercise IMCL content and IMCL depletion was found. IMCL depletion differed strongly between muscles. Absolute and also relative IMCL reduction was significantly higher in muscles with predominantly slow fibers compared to those with fast fibers. Creatine levels and fiber orientation were stable and unchanged after exercise, while trimethyl-ammonium groups increased. This is presented in the accompanying paper. In conclusion, a systematic comparison of metabolic changes in cross sections of the upper and lower leg was performed. The results imply that pre-exercise IMCL levels determine the degree of IMCL depletion after exercise.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Vermathen P,Saillen P,Boss A,Zehnder M,Boesch Cdoi
10.1002/mrm.24168subject
Has Abstractpub_date
2012-11-01 00:00:00pages
1357-67issue
5eissn
0740-3194issn
1522-2594journal_volume
68pub_type
临床试验,杂志文章abstract:PURPOSE:To determine the feasibility of employing the prior knowledge of well-separated chemical exchange saturation transfer (CEST) signals in the 9.4 T Z-spectrum to separate overlapping CEST signals acquired at 3 T, using a deep learning approach trained with 3 T and 9.4 T CEST spectral data from brains of the same ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27690
更新日期:2019-06-01 00:00:00
abstract::Time-dependent changes of T1 in the rotating frame (T1rho), diffusion, T2, and magnetization transfer contrast on cardiac arrest-induced global ischemia in rat were investigated. T1rho, as acquired with spin lock amplitudes >0.6 G, started to increase 10-20 sec after cardiac arrest followed by an increase within 3-4 m...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1228
更新日期:2001-09-01 00:00:00
abstract::Corruption of the image time series due to interimage head motion limits the clinical utility of functional MRI. This paper presents a method for real-time prospective correction of rotation and translation in all six degrees of rigid body motion. By incorporating an orbital navigator (ONAV) echo for each of the sagit...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(200003)43:3<459::aid-mrm19
更新日期:2000-03-01 00:00:00
abstract::An array of 33 prototype polypeptides was examined as putative contrast agents that can be distinguished from each other based on the chemical exchange saturation transfer (CEST) mechanism. These peptides were chosen based on predictions of the chemical exchange rates of exchangeable amide, amine, and hydroxyl protons...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21683
更新日期:2008-10-01 00:00:00
abstract::Subject motion during scan is a major source of artifacts in MR examinations. Prospective motion correction is a promising technique that tracks subject motion and adjusts the imaging volume in real time; however, additional retrospective correction may be necessary to achieve robust image quality and compatibility wi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24269
更新日期:2013-02-01 00:00:00
abstract:PURPOSE:To improve the imaging quality of vessel walls with an endoesophageal Wireless Amplified NMR Detector (WAND). METHODS:A cylindrically shaped double-frequency resonator has been constructed with a single metal wire that is self-connected by a pair of nonlinear capacitors. The double-frequency resonator can conv...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26562
更新日期:2017-11-01 00:00:00
abstract:PURPOSE:Multiple nonlinear gradient fields offer many potential benefits for spatial encoding including reduced acquisition time, fewer artefacts and region-specific imaging, although designing a suitable trajectory for such a setup is difficult. This work aims to optimize encoding trajectories for multiple nonlinear g...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25859
更新日期:2016-07-01 00:00:00
abstract:PURPOSE:To develop a semiautomatic method for rapid segmentation of myocardial tissue phase mapping (TPM) data. METHODS:Manual segmentation of the myocardium was performed at end-diastole and end-systole. The points in both user-defined masks were then automatically tracked over the entire cardiac cycle using temporal...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26486
更新日期:2017-09-01 00:00:00
abstract:PURPOSE:To assess the feasibility of using dissolved hyperpolarized xenon-129 (129 Xe) MRI to study renal physiology in humans at 3 T. METHODS:Using a flexible transceiver RF coil, dynamic and spatially resolved 129 Xe spectroscopy was performed in the abdomen after inhalation of hyperpolarized 129 Xe gas with 3 healt...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27923
更新日期:2020-01-01 00:00:00
abstract:PURPOSE:The optic nerve (ON) represents the sole pathway between the eyes and brain; consequently, diseases of the ON can have dramatic effects on vision. However, quantitative magnetization transfer (qMT) applications in the ON have been limited to ex vivo studies, in part because of the fatty connective tissue that s...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26164
更新日期:2017-02-01 00:00:00
abstract:PURPOSE:To integrate markerless head motion tracking with prospectively corrected neuroanatomical MRI sequences and to investigate high-frequency motion correction during imaging echo trains. METHODS:A commercial 3D surface tracking system, which estimates head motion by registering point cloud reconstructions of the ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27705
更新日期:2019-07-01 00:00:00
abstract::Prospective motion correction methods using an optical system, diffusion-weighted prospective acquisition correction, or a free induction decay navigator have recently been applied to correct for motion in diffusion tensor imaging. These methods have some limitations and drawbacks. This article describes a novel techn...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.23314
更新日期:2012-10-01 00:00:00
abstract::A novel ultra-rapid gradient echo (URGE) NMR imaging technique is introduced, which is capable of continuous high resolution 3D scanning while neither subject to fast gradient switching nor excessive RF power deposition. Sampling free induction decays instead of creating spin echoes enables maintaining a workable stea...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910330123
更新日期:1995-01-01 00:00:00
abstract:PURPOSE:To improve the quality and speed of electron paramagnetic resonance imaging (EPRI) acquisition by combining a uniform sampling distribution with spinning gradient acquisition. THEORY AND METHODS:A uniform sampling distribution was derived for spinning gradient EPRI acquisition (uniform spinning sampling, USS) ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24712
更新日期:2014-02-01 00:00:00
abstract::A MultiEcho Segmented EPI with z-shimmed BAckground gradient Compensation (MESBAC) pulse sequence is proposed and validated for functional MRI (fMRI) study in regions suffering from severe susceptibility artifacts. This sequence provides an effective tradeoff between spatial and temporal resolution and reduces image d...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10219
更新日期:2002-08-01 00:00:00
abstract:PURPOSE:The purpose of the present study was to apply noninvasive methods for monitoring regeneration and mechanical properties of tissue-engineered cartilage in vivo at different growth stages using MR elastography (MRE). METHODS:Three types of scaffolds, including silk, collagen, and gelatin seeded by human mesenchy...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25745
更新日期:2016-03-01 00:00:00
abstract::In vivo lactate detection using gradient enhanced double quantum coherence transfer (DQCT) was significantly improved by addition of short-time-inversion-recovery (STIR). Phantom studies demonstrated lipid suppression down to the background noise level with 33% loss of lactate signal. In vivo studies using a rabbit mo...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910400416
更新日期:1998-10-01 00:00:00
abstract::Electron paramagnetic resonance imaging using nitroxides is a powerful method for visualizing the redox status modulated by oxidative stress in vivo. Typically, however, data acquisition times have been too slow to obtain a sufficient number of projections for three-dimensional images, when using continuous wave-elect...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22598
更新日期:2011-01-01 00:00:00
abstract:PURPOSE:Myocardial blood-flow simulation based on laws of fluid mechanics is a valuable tool for understanding tissue behavior. Our aim is to evaluate the ability of a porous-media flow model approach to reflect disturbed washout of contrast media (CM) from the myocardium as observed by cardiovascular MR. METHODS:A co...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27756
更新日期:2019-08-01 00:00:00
abstract::For protons diffusing among a system of magnetic particles, the process by which initial phase coherence is lost depends substantially on particle size. In this article, evidence for three dephasing mechanisms is presented: an incremental process at small particle sizes (motional averaging regime), a discrete process ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22966
更新日期:2011-12-01 00:00:00
abstract::Parallel transmission has emerged as an efficient means for implementing multidimensional spatially selective radiofrequency excitation pulses. To date, most theoretical and experimental work on parallel transmission radiofrequency (RF) pulse design is based on the small-tip-angle approximation to the Bloch equation. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22827
更新日期:2011-09-01 00:00:00
abstract:PURPOSE:The purpose of this study is to increase the robustness of MR fingerprinting (MRF) toward subject motion. METHODS:A novel reconstruction algorithm, MOtion insensitive MRF (MORF), was developed, which uses an iterative reconstruction based retrospective motion correction approach. Each iteration loops through t...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27227
更新日期:2018-12-01 00:00:00
abstract::The combination of cardiac viability and functional information enhances the identification of different heart tissues in the setting of ischemic heart disease. A method has recently been proposed for obtaining black-blood delayed-enhancement (DE) viability images using the stimulated-echo acquisition mode (STEAM) MRI...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21390
更新日期:2007-10-01 00:00:00
abstract::The eigenimage filter was used to evaluate the results of a MRI study of cerebral ischemia in a rat model. This linear filter segments a desired feature in an image sequence from other features which may interfere with its observation. The animals were imaged temporally, after occlusion of the middle cerebral artery, ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910260207
更新日期:1992-08-01 00:00:00
abstract:PURPOSE:To accelerate dynamic MR applications using infimal convolution of total generalized variation functionals (ICTGV) as spatio-temporal regularization for image reconstruction. THEORY AND METHODS:ICTGV comprises a new image prior tailored to dynamic data that achieves regularization via optimal local balancing b...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26352
更新日期:2017-07-01 00:00:00
abstract:PURPOSE:Going to ultrahigh field MRI (e.g., 7 Tesla [T]), the nonuniformity of the B1+ field and the increased radiofrequency (RF) power deposition become challenging. While surface coils improve the power efficiency in B1+, its field remains nonuniform. In this work, an RF pulse was designed that uses the slab selecti...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25415
更新日期:2015-08-01 00:00:00
abstract:PURPOSE:To investigate the feasibility of estimating calibration constants (K and T2o ) in vivo for converting whole-blood T2 to blood hemoglobin oxygen saturation (HbO2 ) according to the Luz-Meiboom model, 1/T2=1/T2o+K(1-HbO2)2, where K and T2o are relaxivity and transverse relaxation time of fully saturated blood, r...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26885
更新日期:2018-04-01 00:00:00
abstract::This work helps elucidate how background noise introduces statistical artifacts in the distribution of the sorted eigenvalues and eigenvectors in diffusion tensor MRI (DT-MRI) data. Although it was known that sorting eigenvalues (principal diffusivities) by magnitude introduces a bias in their sample mean within a hom...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/1522-2594(200007)44:1<41::aid-mrm8>3.0.co;
更新日期:2000-07-01 00:00:00
abstract::A combined carbogen ultrasmall superparamagnetic iron oxide (USPIO) imaging protocol was developed and applied in vivo in two murine colorectal tumor xenograft models, HCT116 and SW1222, with established disparate vascular morphology, to investigate whether additional information could be extracted from the combinatio...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22779
更新日期:2011-07-01 00:00:00
abstract:PURPOSE:Intracranial and intraspinal compliance are parameters of interest in the diagnosis and prediction of treatment outcome in patients with normal pressure hydrocephalus and other forms of communicating hydrocephalus. A noninvasive method to estimate the spinal cerebrospinal fluid (CSF) pulse wave velocity (PWV) a...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28430
更新日期:2021-01-01 00:00:00