Electrocardiogram acquisition during MR examinations for patient monitoring and sequence triggering.

Abstract:

:We have developed a method for measuring the electrocardiogram (ECG) continuously during MR examinations. In contrast to ECG acquisition by wires, our new method is to amplify and convert the ECG into an optical signal directly above the patient's heart. The optical signal is transmitted out of the magnet bore by optical fiber. The small and fixed dimensions of the ECG amplifier avoid interactions with the MR system because of shorter electrical structures and smaller enclosed areas. Tests of the proposed device in a 1.5 Tesla MR system show that continuous and reliable ECG monitoring and sequence triggering are possible.

journal_name

Magn Reson Med

authors

Felblinger J,Lehmann C,Boesch C

doi

10.1002/mrm.1910320416

subject

Has Abstract

pub_date

1994-10-01 00:00:00

pages

523-9

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

32

pub_type

杂志文章
  • Design of universal parallel-transmit refocusing kT -point pulses and application to 3D T2 -weighted imaging at 7T.

    abstract:PURPOSE:T2 -weighted sequences are particularly sensitive to the radiofrequency (RF) field inhomogeneity problem at ultra-high-field because of the errors accumulated by the imperfections of the train of refocusing pulses. As parallel transmission (pTx) has proved particularly useful to counteract RF heterogeneities, u...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27001

    authors: Gras V,Mauconduit F,Vignaud A,Amadon A,Le Bihan D,Stöcker T,Boulant N

    更新日期:2018-07-01 00:00:00

  • Measurement of Gd-DTPA dialysis clearance rates by using a look-locker imaging technique.

    abstract::The exponential clearance rate constant, (kappa), and filtration fraction (FF) have been measured for dialysis of Gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA) (Magnevist, Berlex, Wayne, NJ) solutions by using a Look-Locker imaging technique under conditions of flow. The measured values of kappa for the Baxt...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360412

    authors: Niendorf ER,Santyr GE,Brazy PC,Grist TM

    更新日期:1996-10-01 00:00:00

  • Analysis of phospholipid molecular species in brain by (31)P NMR spectroscopy.

    abstract::Techniques are described for the (31)P NMR analysis of glycerophospholipid (PL) headgroup and molecular species in brain. The (31)P NMR spectrum of PLs from human temporal cortex, solubilized in aqueous Na cholate, typically showed 3 major resonances, assigned to phosphatidylcholine (PC) molecular species containing 0...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200008)44:2<215::aid-mrm8>3.0.co

    authors: Pearce JM,Komoroski RA

    更新日期:2000-08-01 00:00:00

  • Dynamic activity-induced manganese-dependent contrast magnetic resonance imaging (DAIM MRI).

    abstract::Activity-induced manganese-dependent contrast (AIM) MRI is a hemodynamic-independent functional MRI method that used manganese ion as an MR-detectable contrast agent. In AIM, MnCl(2) is infused intra-arterially after the blood-brain barrier (BBB) is opened with a hyperosmolar agent. Upon functional stimulation of the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10320

    authors: Aoki I,Tanaka C,Takegami T,Ebisu T,Umeda M,Fukunaga M,Fukuda K,Silva AC,Koretsky AP,Naruse S

    更新日期:2002-12-01 00:00:00

  • Improved carotid intraplaque hemorrhage imaging using a slab-selective phase-sensitive inversion-recovery (SPI) sequence.

    abstract::Intraplaque hemorrhage in atherosclerotic plaques has been associated with accelerated plaque growth as well as exacerbation of clinical symptoms. The identification of intraplaque hemorrhage using magnetic resonance imaging primarily relies on the detection of methemoglobin on T(1) weighted images. Current techniques...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22539

    authors: Wang J,Ferguson MS,Balu N,Yuan C,Hatsukami TS,Börnert P

    更新日期:2010-11-01 00:00:00

  • Fast design of local N-gram-specific absorption rate-optimized radiofrequency pulses for parallel transmit systems.

    abstract::Designing multidimensional radiofrequency pulses for clinical application must take into account the local specific absorption rate (SAR) as controlling the global SAR does not guarantee suppression of hot spots. The maximum peak SAR, averaged over an N grams cube (local NgSAR), must be kept under certain safety limit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23049

    authors: Sbrizzi A,Hoogduin H,Lagendijk JJ,Luijten P,Sleijpen GL,van den Berg CA

    更新日期:2012-03-01 00:00:00

  • Eddy current correction in diffusion-weighted imaging using pairs of images acquired with opposite diffusion gradient polarity.

    abstract::In echo-planar-based diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI), the evaluation of diffusion parameters such as apparent diffusion coefficients and anisotropy indices is affected by image distortions that arise from residual eddy currents produced by the diffusion-sensitizing gradients. Correc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10690

    authors: Bodammer N,Kaufmann J,Kanowski M,Tempelmann C

    更新日期:2004-01-01 00:00:00

  • Determination of the optimal first-order gradient moment for flow-sensitive dephasing magnetization-prepared 3D noncontrast MR angiography.

    abstract::Flow-sensitive dephasing (FSD) magnetization preparation has been developed for black-blood vessel wall MRI and noncontrast MR angiography. The first-order gradient moment, m(1) , is a measure of the flow-sensitization imparted by an FSD preparative module. Determination of the optimal m(1) for each individual is high...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22847

    authors: Fan Z,Zhou X,Bi X,Dharmakumar R,Carr JC,Li D

    更新日期:2011-04-01 00:00:00

  • Fast gated EPR imaging of the beating heart: spatiotemporally resolved 3D imaging of free-radical distribution during the cardiac cycle.

    abstract::In vivo or ex vivo electron paramagnetic resonance imaging (EPRI) is a powerful technique for determining the spatial distribution of free radicals and other paramagnetic species in living organs and tissues. However, applications of EPRI have been limited by long projection acquisition times and the consequent fact t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24250

    authors: Chen Z,Reyes LA,Johnson DH,Velayutham M,Yang C,Samouilov A,Zweier JL

    更新日期:2013-02-01 00:00:00

  • Apparent changes of appearance of inversion-recovery images.

    abstract::This note considers the anomolous contrast in inversion recovery images produced by NMR scanners if a map of [My] is reconstructed, rather than a map of My'. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910020110

    authors: Young IR,Bailes DR,Bydder GM

    更新日期:1985-02-01 00:00:00

  • T2-prepared SSFP improves diagnostic confidence in edema imaging in acute myocardial infarction compared to turbo spin echo.

    abstract::T2-weighted MRI of edema in acute myocardial infarction (MI) provides a means of differentiating acute and chronic MI, and assessing the area at risk of infarction. Conventional T2-weighted imaging of edema uses a turbo spin-echo (TSE) readout with dark-blood preparation. Clinical applications of dark-blood TSE method...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21215

    authors: Kellman P,Aletras AH,Mancini C,McVeigh ER,Arai AE

    更新日期:2007-05-01 00:00:00

  • Simultaneous B(0)- and B(1)+-map acquisition for fast localized shim, frequency, and RF power determination in the heart at 3 T.

    abstract::High-field (>or=3 T) cardiac MRI is challenged by inhomogeneities of both the static magnetic field (B(0)) and the transmit radiofrequency field (B(1)+). The inhomogeneous B fields not only demand improved shimming methods but also impede the correct determination of the zero-order terms, i.e., the local resonance fre...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22234

    authors: Schär M,Vonken EJ,Stuber M

    更新日期:2010-02-01 00:00:00

  • High-resolution MRI with cardiac and respiratory gating allows for accurate in vivo atherosclerotic plaque visualization in the murine aortic arch.

    abstract::Genetically engineered mouse models provide enormous potential for investigation of the underlying mechanisms of atherosclerotic disease, but noninvasive imaging methods for analysis of atherosclerosis in mice are currently limited. This study aimed to demonstrate the feasibility of MRI to noninvasively visualize athe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10500

    authors: Wiesmann F,Szimtenings M,Frydrychowicz A,Illinger R,Hunecke A,Rommel E,Neubauer S,Haase A

    更新日期:2003-07-01 00:00:00

  • Inability to directly detect magnetic field changes associated with neuronal activity.

    abstract::The ability to directly detect neuronal magnetic fields by MRI would help investigators achieve the "holy grail" of neuroimaging, namely both high spatial and temporal resolution. Both positive and negative findings have been reported in the literature, with no clear consensus as to the feasibility of direct detection...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21129

    authors: Parkes LM,de Lange FP,Fries P,Toni I,Norris DG

    更新日期:2007-02-01 00:00:00

  • Interleaved variable density sampling with a constrained parallel imaging reconstruction for dynamic contrast-enhanced MR angiography.

    abstract::For MR applications such as contrast-enhanced MR angiography, it is desirable to achieve simultaneously high spatial and temporal resolution. The current clinical standard uses view-sharing methods combined with parallel imaging; however, this approach still provides limited spatial and temporal resolution. To improve...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22814

    authors: Wang K,Busse RF,Holmes JH,Beatty PJ,Brittain JH,Francois CJ,Reeder SB,Du J,Korosec FR

    更新日期:2011-08-01 00:00:00

  • Simulation-based investigation of partially parallel imaging with a linear array at high accelerations.

    abstract::Partially parallel imaging strategies such as SMASH, SENSE, and PILS rely on the sensitivity distribution of phased array RF coils to reduce MRI imaging time. Using an N-element phased array, these techniques allow maximum accelerations, L, such that L < or = N, with acceleration defined as the factor by which scan ti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10113

    authors: Bankson JA,Wright SM

    更新日期:2002-04-01 00:00:00

  • Measurement of myocardial frequency offsets during first pass of a gadolinium-based contrast agent in perfusion studies.

    abstract::MRI of myocardial perfusion observed with an extracellular contrast agent has proven valuable for the detection of coronary artery disease. During contrast enhancement transient dark rim artifacts are sometimes visible, complicating diagnosis and quantification. In this work a quantification of the frequency offsets c...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.21723

    authors: Ferreira P,Gatehouse P,Bucciarelli-Ducci C,Wage R,Firmin D

    更新日期:2008-10-01 00:00:00

  • Diffusion tensor imaging of in vivo and excised rat spinal cord at 7 T with an icosahedral encoding scheme.

    abstract::Regional values of fractional anisotropy (FA) and mean diffusivity (D(av)) of in vivo and excised rat spinal cords were measured using an iscosahedral encoding scheme that is based on 21 uniformly distributed and alternating gradient directions with an echo planar imaging (EPI) readout. Based on the water phantom stud...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20304

    authors: Madi S,Hasan KM,Narayana PA

    更新日期:2005-01-01 00:00:00

  • Removal of nuisance signals from limited and sparse 1H MRSI data using a union-of-subspaces model.

    abstract:PURPOSE:To remove nuisance signals (e.g., water and lipid signals) for (1) H MRSI data collected from the brain with limited and/or sparse (k, t)-space coverage. METHODS:A union-of-subspace model is proposed for removing nuisance signals. The model exploits the partial separability of both the nuisance signals and the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25635

    authors: Ma C,Lam F,Johnson CL,Liang ZP

    更新日期:2016-02-01 00:00:00

  • MRI-guided radiofrequency thermal ablation of implanted VX2 liver tumors in a rabbit model: demonstration of feasibility at 0.2 T.

    abstract::Successful radiofrequency (RF) thermal ablation was performed on VX2 tumors implanted in 23 rabbit livers under magnetic resonance (MR) guidance using a C-arm-shaped low-field 0.2 T system. RF application and immediate postprocedure MRI of all animals was performed [T2-weighted, turbo short tau inversion recovery (STI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199907)42:1<141::aid-mrm19

    authors: Merkle EM,Boll DT,Boaz T,Duerk JL,Chung YC,Jacobs GH,Varnes ME,Lewin JS

    更新日期:1999-07-01 00:00:00

  • Phase-based T2 mapping with gradient echo imaging.

    abstract:PURPOSE:Transverse relaxation time (T2 ) mapping with MRI has a plethora of clinical and research applications. Current T2 mapping techniques are based primarily on spin-echo (SE) relaxometry strategies that rely on the signal magnitude, and often suffer from lengthy acquisition times. In this work, we propose a phase-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28138

    authors: Wang X,Hernando D,Reeder SB

    更新日期:2020-08-01 00:00:00

  • Articular cartilage deformation determined in an intact tibiofemoral joint by displacement-encoded imaging.

    abstract::This study demonstrates the in vitro displacement and strain of articular cartilage in a cyclically-compressed and intact joint using displacement-encoded imaging with stimulated echoes (DENSE) and fast spin echo (FSE). Deformation and strain fields exhibited complex and heterogeneous patterns. The displacements in th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21927

    authors: Chan DD,Neu CP,Hull ML

    更新日期:2009-04-01 00:00:00

  • 3D single-shot VASO using a Maxwell gradient compensated GRASE sequence.

    abstract::The vascular space occupancy (VASO) method was recently proposed as a functional MRI (fMRI) method that is capable of detecting activation-related changes in blood volume (CBV), without the need for a blood-pool contrast agent. In the present work we introduce a new whole-brain VASO technique that is based on a parall...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22000

    authors: Poser BA,Norris DG

    更新日期:2009-07-01 00:00:00

  • Assessing transneuronal dysfunction utilizing manganese-enhanced MRI (MEMRI).

    abstract::In this study we utilized manganese-enhanced MRI (MEMRI) to evaluate the in vivo transneuronal efficiency of manganese ion (Mn(2+)) movement as a means to assess overall changes in neuronal function. We designated this extension the manganese transfer index (MTI) value. To evaluate the MTI value as an index of transne...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21648

    authors: Serrano F,Deshazer M,Smith KD,Ananta JS,Wilson LJ,Pautler RG

    更新日期:2008-07-01 00:00:00

  • NOE enhancements and T1 relaxation times of phosphorylated metabolites in human calf muscle at 1.5 Tesla.

    abstract::Nuclear Overhauser effect (NOE) enhancements and relaxation times of 31P metabolites in human calf were measured in 12 volunteers (4 men and 8 women) at 1.5 T using a dual tuned four-ring birdcage. The NOE enhancements of inorganic phosphate (Pi), phosphocreatine (PCr), gamma-, alpha-, and beta-nucleoside triphosphate...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330316

    authors: Brown TR,Stoyanova R,Greenberg T,Srinivasan R,Murphy-Boesch J

    更新日期:1995-03-01 00:00:00

  • A 7Li NMR study of visibility, spin relaxation, and transport in normal human erythrocytes.

    abstract::The behavior of the lithium (Li) ion in normal human erythrocytes has been studied by 7Li NMR. The uptake of Li into the cells was followed as a function of solution conditions, temperature, hematocrit, and blood age using dysprosium tripolyphosphate shift reagent. Under our conditions the uptake of Li increases with ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910200207

    authors: Gullapalli RP,Hawk RM,Komoroski RA

    更新日期:1991-08-01 00:00:00

  • Measurement of perfusion and permeability from dynamic contrast-enhanced MRI in normal and pathological vertebral bone marrow.

    abstract::Dynamic contrast-enhanced MRI data in vertebral bone marrow (vBM) are currently analyzed with descriptive indices. The purpose of this study was to develop and evaluate a quantitative approach, considering the tissue composition of vBM. Therefore, a measurement of the water fraction, f(wat), and the precontrast relaxa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22415

    authors: Biffar A,Sourbron S,Schmidt G,Ingrisch M,Dietrich O,Reiser MF,Baur-Melnyk A

    更新日期:2010-07-01 00:00:00

  • Response of choline metabolites to docetaxel therapy is quantified in vivo by localized (31)P MRS of human breast cancer xenografts and in vitro by high-resolution (31)P NMR spectroscopy of cell extracts.

    abstract::Choline-containing compounds (CCCs) are elevated in breast cancer, and detected in vivo by the (1)H MRS total choline (tCho) resonance (3.25 ppm) and the (31)P MRS phosphomonoester (PME) resonance (3.8 ppm). Both the tCho and PME resonances decrease early after initiation of successful therapy. The single major compon...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21333

    authors: Morse DL,Raghunand N,Sadarangani P,Murthi S,Job C,Day S,Howison C,Gillies RJ

    更新日期:2007-08-01 00:00:00

  • Intravoxel incoherent motion imaging using steady-state free precession.

    abstract::IVIM MR imaging is a method which generates images of diffusion and perfusion in vivo. Until now, intravoxel incoherent motion (IVIM) images have been obtained using spin-echo sequences with extragradient pulses, resulting in long acquisition times (typically 2 x 8 min 32 s). A new method is proposed here, using stead...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910070312

    authors: Le Bihan D

    更新日期:1988-07-01 00:00:00

  • A flexible fast spin echo triple-echo Dixon technique.

    abstract:PURPOSE:To develop a flexible fast spin echo (FSE) triple-echo Dixon (FTED) technique. METHODS:An FSE pulse sequence was modified by replacing each readout gradient with three fast-switching bipolar readout gradients with minimal interecho dead time. The corresponding three echoes were used to generate three raw image...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26186

    authors: Son JB,Hwang KP,Madewell JE,Bayram E,Hazle JD,Low RN,Ma J

    更新日期:2017-03-01 00:00:00