Development of an inductively coupled MR coil system for imaging and spectroscopic analysis of an implantable bioartificial construct at 11.1 T.

Abstract:

:Developing a method to noninvasively monitor tissue-engineered constructs is critical for the optimization of construct design and for assessing therapeutic efficacy. For this purpose, NMR is a powerful technique that can be used to obtain both images and spectroscopic data. But the inherent sensitivity of NMR limits the observation of a bioartificial construct with current NMR surface coil technology. In this study, we address this limitation through the development of an inductively coupled, implantable coil system, demonstrate its use at high field (11.1 T), and investigate the use of this coil system for monitoring a bioartificial construct in vitro and in vivo. The results establish that large gains in signal to noise can be obtained with this coil system over that obtainable with a surface coil. This coil system provides a means to quantitatively analyze the structure and function of implanted bioartificial organs.

journal_name

Magn Reson Med

authors

Volland NA,Mareci TH,Constantinidis I,Simpson NE

doi

10.1002/mrm.22268

subject

Has Abstract

pub_date

2010-04-01 00:00:00

pages

998-1006

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

63

pub_type

杂志文章
  • Echo-volume imaging.

    abstract::Two single-shot volume imaging techniques are described. The first, single-echo echo-volume imaging, is essentially the echo-volume imaging (EVI) sequence suggested by Mansfield (J. Phys. C. 10, L55 (1977)). The second is a multi-spin-echo approach in which one plane of k-space is collected during each spin echo. In b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320518

    authors: Song AW,Wong EC,Hyde JS

    更新日期:1994-11-01 00:00:00

  • Enhancement of respiratory navigator-gated three-dimensional spoiled gradient-recalled echo sequence with variable flip angle scheme.

    abstract:PURPOSE:To develop and demonstrate the feasibility of a new technique for respiratory-gated, fat-suppressed, three-dimensional spoiled gradient-recalled echo (3D-SPGR) with navigator gating for more accurate and robust motion detection. METHODS:A navigator-gated 3D-SPGR technique was modified to include a wait period ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24902

    authors: Iwadate Y,Brau AC,Vasanawala SS,Kabasawa H

    更新日期:2014-07-01 00:00:00

  • 1H NMR relaxation measurements of human tissues in situ by spatially resolved spectroscopy.

    abstract::Spatially resolved spectroscopy (SPARS) is a method for obtaining high-resolution NMR spectra of well-defined volumes of human tissues in situ. This method was combined with the Carr-Purcell-Meiboom-Gill multiple-echo sequence for T2, and with inversion recovery for T1 relaxation measurements. Relaxation times obtaine...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040504

    authors: Luyten PR,Anderson CM,den Hollander JA

    更新日期:1987-05-01 00:00:00

  • Echo-planar imaging of the human fetus in utero.

    abstract::We have demonstrated that echo-planar imaging can be used to produce high-quality snapshot images of the human fetus in utero in a fraction of a second. These images are free of motional artifact or blurring and allow detailed depiction of fetal structures in normal and pathological pregnancies. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910130214

    authors: Stehling MK,Mansfield P,Ordidge RJ,Coxon R,Chapman B,Blamire A,Gibbs P,Johnson IR,Symonds EM,Worthington BS

    更新日期:1990-02-01 00:00:00

  • Automatic segmentation of the brain and intracranial cerebrospinal fluid in T1-weighted volume MRI scans of the head, and its application to serial cerebral and intracranial volumetry.

    abstract::A new fully automatic algorithm for the segmentation of the brain and total intracranial cerebrospinal fluid (CSF) from T(1)-weighted volume MRI scans of the head, called Exbrain v.2, is described. The algorithm was developed in the context of serial intracranial volumetry. A brain mask obtained using a previous versi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10436

    authors: Lemieux L,Hammers A,Mackinnon T,Liu RS

    更新日期:2003-05-01 00:00:00

  • Robust 4D flow denoising using divergence-free wavelet transform.

    abstract:PURPOSE:To investigate four-dimensional flow denoising using the divergence-free wavelet (DFW) transform and compare its performance with existing techniques. THEORY AND METHODS:DFW is a vector-wavelet that provides a sparse representation of flow in a generally divergence-free field and can be used to enforce "soft" ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25176

    authors: Ong F,Uecker M,Tariq U,Hsiao A,Alley MT,Vasanawala SS,Lustig M

    更新日期:2015-02-01 00:00:00

  • In vivo detection of 2-hydroxyglutarate in brain tumors by optimized point-resolved spectroscopy (PRESS) at 7T.

    abstract:PURPOSE:To test the efficacy of 7T MRS for in vivo detection of 2-hydroxyglutarate (2HG) in brain tumors. METHODS:The subecho times of point-resolved spectroscopy (PRESS) were optimized at 7T with density-matrix simulations and phantom validation to improve the 2HG signal selectivity with respect to the neighboring re...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26190

    authors: Ganji SK,An Z,Tiwari V,McNeil S,Pinho MC,Pan E,Mickey BE,Maher EA,Choi C

    更新日期:2017-03-01 00:00:00

  • Echo-planar imaging with prospective slice-by-slice motion correction using active markers.

    abstract::Head motion is a fundamental problem in functional magnetic resonance imaging and is often a limiting factor in its clinical implementation. This work presents a rigid-body motion correction strategy for echo-planar imaging sequences that uses micro radiofrequency coil "active markers" for real-time, slice-by-slice pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22780

    authors: Ooi MB,Krueger S,Muraskin J,Thomas WJ,Brown TR

    更新日期:2011-07-01 00:00:00

  • Potassium transport in Langendorff-perfused mouse hearts assessed by 87Rb NMR spectroscopy.

    abstract::We studied the fluxes of a potassium congener (Rb(+)) in mouse hearts by (87)Rb MRS at 8.4T. The hearts were loaded with Rb(+) by perfusion with Krebs-Henseleit buffer, in which 50% of K(+) was substituted with Rb(+). We initiated Rb(+) efflux by changing the perfusion medium to Rb(+)-free buffer. Spectra were acquire...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20450

    authors: Jilkina O,Xiang B,Kuzio B,Rendell J,Kupriyanov VV

    更新日期:2005-05-01 00:00:00

  • Comparison of k-space sampling schemes for multidimensional MR spectroscopic imaging.

    abstract::For clinical 31P MR spectroscopic imaging (MRSI) studies, where signal averaging is necessary, some improvement of sensitivity and spatial response function may be achieved by acquiring data over a spherical k-space volume and varying the number of averages acquired in proportion to the desired spatial filter. Eight d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360321

    authors: Hugg JW,Maudsley AA,Weiner MW,Matson GB

    更新日期:1996-09-01 00:00:00

  • Real-time method for motion-compensated MR thermometry and MRgHIFU treatment in abdominal organs.

    abstract:PURPOSE:Magnetic resonance-guided high-intensity focused ultrasound is considered to be a promising treatment for localized cancer in abdominal organs such as liver, pancreas, or kidney. Abdominal motion, anatomical arrangement, and required sustained sonication are the main challenges. METHODS:MR acquisition consiste...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25017

    authors: Celicanin Z,Auboiroux V,Bieri O,Petrusca L,Santini F,Viallon M,Scheffler K,Salomir R

    更新日期:2014-10-01 00:00:00

  • Free-breathing volumetric fat/water separation by combining radial sampling, compressed sensing, and parallel imaging.

    abstract:PURPOSE:Conventional fat/water separation techniques require that patients hold breath during abdominal acquisitions, which often fails and limits the achievable spatial resolution and anatomic coverage. This work presents a novel approach for free-breathing volumetric fat/water separation. METHODS:Multiecho data are ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26392

    authors: Benkert T,Feng L,Sodickson DK,Chandarana H,Block KT

    更新日期:2017-08-01 00:00:00

  • Designing hyperbolic secant excitation pulses to reduce signal dropout in gradient-echo echo-planar imaging.

    abstract:PURPOSE:To design hyperbolic secant (HS) excitation pulses to reduce signal dropout in the orbitofrontal and inferior temporal regions in gradient-echo echo-planar imaging (GE-EPI) for functional MRI (fMRI) applications. METHODS:An algorithm based on Bloch simulations optimizes the HS pulse parameters needed to give t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25444

    authors: Wastling SJ,Barker GJ

    更新日期:2015-09-01 00:00:00

  • Fast Fourier imaging.

    abstract::A new NMR imaging technique, aiming at a reduction of the data acquisition time, is described in detail. The method is applicable in all multidimensional imaging situations where at least one spatial coordinate is resolved. Discussed at some length are the point-spread function, the required bandwidth of the NMR spect...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910020304

    authors: van Uijen CM,den Boef JH,Verschuren FJ

    更新日期:1985-06-01 00:00:00

  • Online correction of respiratory-induced field disturbances for continuous MR-thermometry in the breast.

    abstract::MR-thermometry allows monitoring of the local temperature evolution during minimally invasive interventional therapies. However, for the particular case of MR-thermometry in the human breast, magnetic field variations induced by the respiratory cycle lead to phase fluctuations requiring a suitable correction strategy ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21954

    authors: Hey S,Maclair G,de Senneville BD,Lepetit-Coiffe M,Berber Y,Köhler MO,Quesson B,Moonen CT,Ries M

    更新日期:2009-06-01 00:00:00

  • Evaluation of multicontrast MRI including fat suppression and inversion recovery spin echo for identification of intra-plaque hemorrhage and lipid core in human carotid plaque using the mahalanobis distance measure.

    abstract::Intra-plaque hemorrhage (IPH) and lipid core, characteristics of rupture prone carotid plaques, are often visualized in vivo with MRI using T1 weighted gradient and spin echo, respectively. Increasing magnetic field strength may help to identify IPH and lipid core better. As a proof of concept, automatic segmentation ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23191

    authors: te Boekhorst BC,van 't Klooster R,Bovens SM,van de Kolk KW,Cramer MJ,van Oosterhout MF,Doevendans PA,van der Geest RJ,Pasterkamp G,van Echteld CJ

    更新日期:2012-06-01 00:00:00

  • Volumetric analysis of white matter, gray matter, and CSF using fractional volume analysis.

    abstract::Quantitative cerebral tissue volumes may be useful for an objective assessment of pathological changes in brain. Accurate determination of tissue volumes is complicated, however, by the partial volume averaging (PVA) effect. We have, therefore, developed a new pulse sequence that minimizes the PVA through the use of i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390614

    authors: Bedell BJ,Narayana PA

    更新日期:1998-06-01 00:00:00

  • On the overestimation of early wall thickening at the carotid bulb by black blood MRI, with implications for coronary and vulnerable plaque imaging.

    abstract::Black blood MRI is an attractive tool for monitoring normal and pathological wall thickening; however, limited spatial resolutions can conspire with complex vascular geometries to distort the appearance of the wall in ways hitherto unclear. To elucidate this, a thin-walled cylinder model was developed to predict the c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21758

    authors: Antiga L,Wasserman BA,Steinman DA

    更新日期:2008-11-01 00:00:00

  • In vivo and ex vivo MR imaging of slowly cycling melanoma cells.

    abstract::Slowly cycling cells are believed to play a critical role in tumor progression and metastatic dissemination. The goal of this study was to develop a method for in vivo detection of slowly cycling cells. To distinguish these cells from more rapidly proliferating cells that constitute the vast majority of cells in tumor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22917

    authors: Magnitsky S,Roesch A,Herlyn M,Glickson JD

    更新日期:2011-11-01 00:00:00

  • MR-derived cerebral blood volume maps: issues regarding histological validation and assessment of tumor angiogenesis.

    abstract::In an effort to develop MRI methods for the evaluation of tumor angiogenesis (new blood vessel formation), MRI-derived cerebral blood volume (CBV) information has been compared to histologic measures of microvessel density (MVD). Although MVD is a standard marker of angiogenesis, it is not a direct correlate of the vo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1252

    authors: Pathak AP,Schmainda KM,Ward BD,Linderman JR,Rebro KJ,Greene AS

    更新日期:2001-10-01 00:00:00

  • Cortical hypoperfusion in the B6.PS2APP mouse model for Alzheimer's disease: comprehensive phenotyping of vascular and tissular parameters by MRI.

    abstract::Function and morphology of the cerebral vasculature were studied in the amyloid (Abeta) plaque-containing double-transgenic (TG) B6.PS2APP Alzheimer's disease (AD) mouse model with MRI at an age range of 10 to 17 months. Perfusion, blood volume, and average vessel geometry were assessed in the brain and compared to ag...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21985

    authors: Weidensteiner C,Metzger F,Bruns A,Bohrmann B,Kuennecke B,von Kienlin M

    更新日期:2009-07-01 00:00:00

  • Sensitivity and source of amine-proton exchange and amide-proton transfer magnetic resonance imaging in cerebral ischemia.

    abstract:PURPOSE:Amide-proton transfer (APT) and amine-water proton exchange (APEX) MRI can be viable to map pH-decreasing ischemic regions. However, their exact contributions are unclear. METHODS:We measured APEX- and APT-weighted magnetization transfer ratio asymmetry (denoted as APEXw and APTw), apparent diffusion coefficie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24639

    authors: Zong X,Wang P,Kim SG,Jin T

    更新日期:2014-01-01 00:00:00

  • On consideration of radiated power in RF field simulations for MRI.

    abstract::In numerical analyses of radiofrequency (RF) fields for MRI, RF power is often permitted to radiate out of the problem region. In reality, RF power will be confined by the magnet bore and RF screen enclosing the magnet room. We present numerical calculations at different frequencies for various surface and volume coil...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24244

    authors: Liu W,Kao CP,Collins CM,Smith MB,Yang QX

    更新日期:2013-01-01 00:00:00

  • Characterization of estrogen-receptor-targeted contrast agents in solution, breast cancer cells, and tumors in vivo.

    abstract::The estrogen receptor (ER) is a major prognostic biomarker of breast cancer, currently determined in surgical specimens by immunohistochemistry. Two new ER-targeted probes, pyridine-tetra-acetate-Gd chelate (PTA-Gd) conjugated either to 17β-estradiol (EPTA-Gd) or to tamoxifen (TPTA-Gd), were explored as contrast agent...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24442

    authors: Pais A,Biton IE,Margalit R,Degani H

    更新日期:2013-07-01 00:00:00

  • Fast gated EPR imaging of the beating heart: spatiotemporally resolved 3D imaging of free-radical distribution during the cardiac cycle.

    abstract::In vivo or ex vivo electron paramagnetic resonance imaging (EPRI) is a powerful technique for determining the spatial distribution of free radicals and other paramagnetic species in living organs and tissues. However, applications of EPRI have been limited by long projection acquisition times and the consequent fact t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24250

    authors: Chen Z,Reyes LA,Johnson DH,Velayutham M,Yang C,Samouilov A,Zweier JL

    更新日期:2013-02-01 00:00:00

  • Towards elimination of the dark-rim artifact in first-pass myocardial perfusion MRI: removing Gibbs ringing effects using optimized radial imaging.

    abstract:PURPOSE:Subendocardial dark-rim artifacts (DRAs) remain a major concern in first-pass perfusion (FPP) myocardial MRI and may lower the diagnostic accuracy for detection of ischemia. A major source of DRAs is the "Gibbs ringing" effect. We propose an optimized radial acquisition strategy aimed at eliminating ringing-ind...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24913

    authors: Sharif B,Dharmakumar R,LaBounty T,Arsanjani R,Shufelt C,Thomson L,Merz CN,Berman DS,Li D

    更新日期:2014-07-01 00:00:00

  • Removal of phase artifacts from fMRI data using a Stockwell transform filter improves brain activity detection.

    abstract::A novel and automated technique is described for removing fMRI image artifacts resulting from motion outside of the imaging field of view. The technique is based on the Stockwell transform (ST), a mathematical operation that provides the frequency content at each time point within a time-varying signal. Using this tec...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10681

    authors: Goodyear BG,Zhu H,Brown RA,Mitchell JR

    更新日期:2004-01-01 00:00:00

  • A new approach to Z-spectrum acquisition: prospective baseline enhancement (PROBE) for CEST/Nuclear Overhauser Effect.

    abstract:PURPOSE:To develop a prospective baseline enhancement that compensates for intermingled background effects in Z-spectra to achieve sensitivity enhancement of peaks related to CEST and nuclear Overhauser effect. METHODS:An MRI sequence-specific compensation of background effects is achieved through variation of the pul...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27555

    authors: Lenich T,Pampel A,Mildner T,Möller HE

    更新日期:2019-04-01 00:00:00

  • Two-dimensional imaging in a lightweight portable MRI scanner without gradient coils.

    abstract:PURPOSE:As the premiere modality for brain imaging, MRI could find wider applicability if lightweight, portable systems were available for siting in unconventional locations such as intensive care units, physician offices, surgical suites, ambulances, emergency rooms, sports facilities, or rural healthcare sites. METH...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25147

    authors: Cooley CZ,Stockmann JP,Armstrong BD,Sarracanie M,Lev MH,Rosen MS,Wald LL

    更新日期:2015-02-01 00:00:00

  • Sliding time of flight: sliding time of flight MR angiography using a dynamic image reconstruction method.

    abstract:PURPOSE:To obtain three-dimensional (3D) MR angiography having high contrast between vessel and stationary background tissue, a novel technique called sliding time of flight (TOF) is proposed. METHODS:The proposed method relies on the property that flow-related enhancement (FRE) is maximized at the blood-entering slic...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25215

    authors: Choi J,Seo H,Lim Y,Han Y,Park H

    更新日期:2015-03-01 00:00:00