Abstract:
PURPOSE:To develop a prospective baseline enhancement that compensates for intermingled background effects in Z-spectra to achieve sensitivity enhancement of peaks related to CEST and nuclear Overhauser effect. METHODS:An MRI sequence-specific compensation of background effects is achieved through variation of the pulsed saturation power, ω 1 , max , with the chemical shift, δ . After a "scout acquisition" of a standard Z-spectrum, the background is modeled through an appropriate spin system. Subsequently, an optimization procedure yields ω 1 , m a x ( δ ) values that compensate for background contributions yielding a flat baseline. Contributions from metabolites not considered in the optimization procedure are enhanced as distinct perturbations to the baseline. For experimental verification, mapping of the lactate concentration in the presence of cross-linked bovine serum albumin was performed in phantoms at 7 T. As proof of concept, explorative experiments were performed in healthy human subjects at 3 T. RESULTS:Nuisance contributions from direct water saturation, macromolecular magnetization transfer, and exchanging background protons were successfully removed from the Z-spectrum in phantoms and in brain tissue. The lactate methyl, methine, and hydroxyl peaks were readily observable in vitro. The peak areas correlated linearly with known concentrations. Improvement of the detection limit was achieved by a sparse distribution of saturation frequencies, allowing for more efficient signal averaging. CONCLUSION:An optimization framework for high-resolution metabolite mapping by means of CEST/nuclear Overhauser effect was developed. It offers full flexibility to select spin-pool moieties, whose influence on the Z-spectrum will be compensated. Deviations from this background model will provide a contrast at the respective offset frequencies.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Lenich T,Pampel A,Mildner T,Möller HEdoi
10.1002/mrm.27555subject
Has Abstractpub_date
2019-04-01 00:00:00pages
2315-2329issue
4eissn
0740-3194issn
1522-2594journal_volume
81pub_type
杂志文章abstract::A receive-only phased-array coil was designed to image the lower extremities. The array consists of four volume coils placed on two cylindrical formers. The coil array has the ability to image both legs simultaneously over a 40 cm longitudinal field of view (FOV). Experiments using phantoms show an increase in signal-...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10712
更新日期:2004-03-01 00:00:00
abstract::In vivo effective relaxation rates in normal rat liver were evaluated for four dextran coated iron oxide agents: monocrystalline iron oxide nanocolloid (MION) with a mean particle diameter of 3.9 nm, a polycrystalline agent (PION) with a larger mean diameter of 12 nm, and these two agents labeled with the asialofetuin...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910370613
更新日期:1997-06-01 00:00:00
abstract::MnCl(2) was injected intrathecally through the cisterna magna in rats, allowing infusion of divalent manganese ions (Mn(++)) into the CSF space and thence into the brain, without breaking the blood-brain barrier (BBB). Mn(++) uptake and washout dynamics in the brain were measured by serial T(1)-weighted MRI and EPI T(...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20047
更新日期:2004-05-01 00:00:00
abstract:PURPOSE:The goal of this work was to detect disease-related microstructural changes to the liver using magnetic resonance imaging. Chronic liver disease can cause microstructural changes in the liver that reduce plasma access to the perisinusoidal space--the site of exchange between the blood plasma and the hepatic par...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24619
更新日期:2013-12-01 00:00:00
abstract::Cell death by apoptosis is critical in myocardial diseases, and noninvasive detection of early, reversible apoptosis might be useful clinically. Exogenous Annexin-V (ANX) protein binds membrane phosphatidylserine, which is externalized in early apoptosis. A molecular MRI probe was constructed with superparamagnetic ir...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22876
更新日期:2011-10-01 00:00:00
abstract:PURPOSE:To determine the feasibility of employing the prior knowledge of well-separated chemical exchange saturation transfer (CEST) signals in the 9.4 T Z-spectrum to separate overlapping CEST signals acquired at 3 T, using a deep learning approach trained with 3 T and 9.4 T CEST spectral data from brains of the same ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27690
更新日期:2019-06-01 00:00:00
abstract:PURPOSE:An increasing number of studies show that magnetic susceptibility in white matter fibers is anisotropic and may be described by a tensor. However, the limited head rotation possible for in vivo human studies leads to an ill-conditioned inverse problem in susceptibility tensor imaging (STI). Here we suggest the ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25322
更新日期:2014-09-01 00:00:00
abstract:PURPOSE:A generalized intravoxel incoherent motion (IVIM) model, called the GIVIM, was proposed to better account for complex perfusion present in the tissues having various vessels and flow regimes, such as the liver. THEORY AND METHODS:The notions of continuous pseudodiffusion variable as well as perfusion fraction ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26064
更新日期:2016-11-01 00:00:00
abstract::A modular, user-friendly computer simulation of NMR imaging was created for the DEC VAX computer. This simulation is novel in that complex imaging phenomena, such as chemical shifts and flow, may be easily studied. Other features include spin warp and backprojection imaging, movie generation, and simulation of image c...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910030302
更新日期:1986-06-01 00:00:00
abstract::Image contrast with gradient-recalled echo sequences (GRE) used for fMRI can have both blood oxygen level-dependent (BOLD) and inflow components, and the latter is often undesirable. A dual-echo technique can be used to differentiate these mechanisms, because modulation of signal from inflow is common to both echoes, ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910350306
更新日期:1996-03-01 00:00:00
abstract::In the recently proposed technique Sweep Imaging with Fourier Transform (SWIFT), frequency-modulated radiofrequency pulses are used in concert with simultaneous acquisition to facilitate MRI of samples with very short transverse relaxation time. In the present work, sweep MRI is reviewed from a reconstruction perspect...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22516
更新日期:2010-12-01 00:00:00
abstract:PURPOSE:The goal of this study was to conduct an exposure assessment for workers moving through the stray stationary field of common MRI scanners, performed according to the recent International Commission on Non-Ionizing Radiation Protection (ICNIRP) Guidelines, which aim at avoiding annoying sensory effects. THEORY ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26031
更新日期:2016-10-01 00:00:00
abstract:PURPOSE:The goal of this study was to measure and compare the apparent transverse relaxation time constants (T2 ) of five intracellular metabolites using localization by adiabatic selective refocusing (LASER) and point-resolved spectroscopy (PRESS) sequences in the human brain at 3 T. METHODS:Five healthy subjects wer...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26826
更新日期:2018-03-01 00:00:00
abstract::A comparison between contrast and signal-to-noise ratio (SNR), as obtained by both maximum entropy (ME) and 2DFT reconstruction, is reported for NMR images. Our results show that in the ME elaboration the contrast and SNR are generally increased with respect to the 2DFT elaboration. The magnitude of such an increase d...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910080310
更新日期:1988-11-01 00:00:00
abstract::The ability to generate in vivo maps of lactate may have significant diagnostic utility in staging and treatment planning of a wide variety of cancers. The double selective multiple quantum filter technique (SelMQC) has been shown to be effective for nonlocalized detection of lactate with little or no interference fro...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21659
更新日期:2008-08-01 00:00:00
abstract:PURPOSE:Accurate characterization of contrast reagent (CR) longitudinal relaxivity in whole blood is required to predict arterial signal intensity in contrast-enhanced MR angiography (CE-MRA). This study measured the longitudinal relaxation rate constants (R1 ) over a concentration range for non-protein-binding and pro...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25064
更新日期:2014-12-01 00:00:00
abstract::Uncertainty regarding the intracellular/extracellular distribution of inorganic phosphate (P(i)) in tumors has raised concerns that pH calculated from the tumor P(i) chemical shift may not accurately represent the intracellular pH (pHin). This issue was addressed in subcutaneously transplanted murine radiation induced...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910360508
更新日期:1996-11-01 00:00:00
abstract:PURPOSE:To determine the in vitro accuracy, test-retest repeatability, and interplatform reproducibility of T1 quantification protocols used for dynamic contrast-enhanced MRI at 1.5 and 3 T. METHODS:A T1 phantom with 14 samples was imaged at eight centers with a common inversion-recovery spin-echo (IR-SE) protocol and...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26903
更新日期:2018-05-01 00:00:00
abstract:PURPOSE:The aim of this work was to quantify the extent of lipid-rich necrotic core (LRNC) and intraplaque hemorrhage (IPH) in atherosclerotic plaques. METHODS:Patients scheduled for carotid endarterectomy underwent four-point Dixon and T1-weighted magnetic resonance imaging (MRI) at 3 Tesla. Fat and R2* maps were gen...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26359
更新日期:2017-07-01 00:00:00
abstract::Designing multidimensional radiofrequency pulses for clinical application must take into account the local specific absorption rate (SAR) as controlling the global SAR does not guarantee suppression of hot spots. The maximum peak SAR, averaged over an N grams cube (local NgSAR), must be kept under certain safety limit...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.23049
更新日期:2012-03-01 00:00:00
abstract::When deoxygenated, blood behaves as an effective susceptibility contrast agent. Changes in brain oxygenation can be monitored using gradient-echo echo-planar imaging. With this technique, difference images also demonstrate that blood oxygenation is increased during periods of recovery from respiratory challenge. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910220117
更新日期:1991-11-01 00:00:00
abstract::A previously developed eigenvector formalism is adapted to off-resonance in the transient response of quasiperiodic steady-state free precession (SSFP) sequences, including TrueFISP as a special case. The effective relaxation rates for essentially parallel and perpendicular deviations from the steady state are determi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20173
更新日期:2004-08-01 00:00:00
abstract:PURPOSE:To assess the use of image registration for correcting respiratory motion in free breathing lung T1 mapping acquisition in patients with idiopathic pulmonary fibrosis (IPF). THEORY AND METHODS:The method presented used image registration to synthetic images during postprocessing to remove respiratory motion. S...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28342
更新日期:2020-12-01 00:00:00
abstract::A new strategy for a quantitative measurement of regional pulmonary ventilation using hyperpolarized helium-3 (3He) MRI has been developed. The method employs the build-up of the signal intensity after a variable number of (3)He breaths. A mathematical model of the signal dynamics is presented, from which the local ve...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10206
更新日期:2002-08-01 00:00:00
abstract::High polarization of nuclear spins in liquid state through hyperpolarized technology utilizing dynamic nuclear polarization has enabled the direct monitoring of (13)C metabolites in vivo at a high signal-to-noise ratio. Acquisition time limitations due to T(1) decay of the hyperpolarized signal require accelerated ima...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22233
更新日期:2010-02-01 00:00:00
abstract:PURPOSE:For ultrahigh field (UHF) MRI, the expected local specific absorption rate (SAR) distribution is usually calculated by numerical simulations using a limited number of generic body models and adding a safety margin to take into account intersubject variability. Assessment of this variability with a large model d...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27518
更新日期:2019-03-01 00:00:00
abstract:PURPOSE:To present and validate a new method that formalizes a direct link between k-space and wavelet domains to apply separate undersampling and reconstruction for high- and low-spatial-frequency k-space data. THEORY AND METHODS:High- and low-spatial-frequency regions are defined in k-space based on the separation o...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24592
更新日期:2013-11-01 00:00:00
abstract:PURPOSE:To present a double diffusion encoding MRI sequence on a clinical scanner to analyze micro-structure and micro-vasculature of tumors. METHODS:The sequence was tested on phantoms, asparaguses, and 2 tumors allografts in a rodent. Results were analyzed using an adapted VERDICT model to estimate microstructural p...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28012
更新日期:2020-04-01 00:00:00
abstract::In this study, the precision and accuracy of a new method for measuring axial rotations of the lumbar vertebrae, which are thought to be increased in patients with degenerative spinal instability, were estimated. A standard image registration algorithm involving a user-selected center of rotation was adapted for this ...
journal_title:Magnetic resonance in medicine
pub_type: 临床试验,杂志文章
doi:10.1002/mrm.10319
更新日期:2002-12-01 00:00:00
abstract::Three-dimensional (3D) coronary imaging has the potential to overcome problems resulting from vessel tortuosity and to reduce partial volume effects. With these techniques, however, acquisition times are long and respiratory motion artifacts problematical. This work describes the development of a method that applies p...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199903)41:3<555::aid-mrm19
更新日期:1999-03-01 00:00:00