Abstract:
PURPOSE:Amide-proton transfer (APT) and amine-water proton exchange (APEX) MRI can be viable to map pH-decreasing ischemic regions. However, their exact contributions are unclear. METHODS:We measured APEX- and APT-weighted magnetization transfer ratio asymmetry (denoted as APEXw and APTw), apparent diffusion coefficient, T2 , and T1 images and localized proton spectra in rats with permanent middle cerebral artery occlusion at 9.4 T. Phantoms and theoretical studies were also performed. RESULTS:Within 1-h postocclusion, APEXw and APTw maps showed hyperintensity (3.1% of M0 ) and hypointensity (-1.8%), respectively, in regions with decreased apparent diffusion coefficient. Ischemia increased lactate and gamma aminobutyric acid concentrations, but decreased glutamate and taurine concentrations. Over time, the APEXw contrast decreased with glutamate, taurine, and creatine, whereas the APTw contrast and lactate level were similar. Phantom and theoretical studies suggest that the source of APEXw signal is mainly from proteins at normal pH, whereas at decreased pH, gamma aminobutyric acid and glutamate contributions increase, inducing the positive APEXw contrast in ischemic regions. The APTw contrast is sensitive to lactate concentration and pH, but contaminated from contributions of the faster APEX processes. CONCLUSION:Positive APEXw contrast is more sensitive to ischemia than negative APTw contrast. They may provide complementary tissue metabolic information.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Zong X,Wang P,Kim SG,Jin Tdoi
10.1002/mrm.24639subject
Has Abstractpub_date
2014-01-01 00:00:00pages
118-32issue
1eissn
0740-3194issn
1522-2594journal_volume
71pub_type
杂志文章abstract::Emerging applications of sodium bioscales derived from quantitative sodium magnetic resonance imaging assess temporal changes in regional sodium concentration over intervals that vary from hours (monitoring tissue viability in stroke) to weeks (monitoring brain tumor treatment during radiation therapy) or even years (...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.23285
更新日期:2012-09-01 00:00:00
abstract:PURPOSE:Cross-term spatiotemporal encoding (xSPEN) is a single-shot approach with exceptional immunity to field heterogeneities, the images of which faithfully deliver 2D spatial distributions without requiring a priori information or using postacquisition corrections. xSPEN, however, suffers from signal-to-noise ratio...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26824
更新日期:2018-03-01 00:00:00
abstract::For sodium imaging of the human brain, Gibbs' ringing can degrade image appearance and confound image analysis; k-space filtering is generally required. In this work, the signal to noise ratio (SNR) advantage of sampling density weighted apodization (SDWA) over uniform k-space sampling with postacquisition filtering a...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21738
更新日期:2008-10-01 00:00:00
abstract::Subject motion during brain magnetic resonance spectroscopy acquisitions generally reduces the magnetic field (B₀) homogeneity across the volume of interest or voxel. This is the case even if prospective motion correction ensures that the voxel follows the head. We introduce a novel method for rapidly mapping linear v...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24129
更新日期:2012-11-01 00:00:00
abstract:PURPOSE:To test the efficacy of 7T MRS for in vivo detection of 2-hydroxyglutarate (2HG) in brain tumors. METHODS:The subecho times of point-resolved spectroscopy (PRESS) were optimized at 7T with density-matrix simulations and phantom validation to improve the 2HG signal selectivity with respect to the neighboring re...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26190
更新日期:2017-03-01 00:00:00
abstract::The potential application of gas microbubbles as a unique intravascular susceptibility contrast agent for MRI has not been fully explored. In this study, the MR susceptibility effect of an ultrasound microbubble contrast agent, Optison, was studied with rat liver imaging at 7 T. Optison suspension in two different dos...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20181
更新日期:2004-09-01 00:00:00
abstract::The combination of a frequency nonselective excitation suppression method (1331 sequence) with selective excitation followed by gradient-induced dephasing of water transverse magnetization yielded suppression ratios of greater than 10,000:1. The need for gradient preemphasis and correction of B0 field shifts is discus...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910090114
更新日期:1989-01-01 00:00:00
abstract:PURPOSE:Recently, natural d-glucose was suggested as a potential biodegradable contrast agent. The feasibility of using d-glucose for dynamic perfusion imaging was explored to detect malignant brain tumors based on blood brain barrier breakdown. METHODS:Mice were inoculated orthotopically with human U87-EGFRvIII gliom...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25995
更新日期:2015-12-01 00:00:00
abstract::Echo-planar spectroscopic imaging (EPSI) can be used for fast spectroscopic imaging of water and fat resonances at high resolution to improve structural and functional imaging. Because of the use of oscillating gradients during the free induction decay (FID), spectra obtained with EPSI are often degraded by Nyquist gh...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10485
更新日期:2003-06-01 00:00:00
abstract::Double wave vector diffusion weighting uses gradients along two different directions between excitation and acquisition. It has been shown theoretically that for restricted diffusion the signal amplitude in such an experiment can depend on the angle between the two gradient vectors. The highest amplitude is obtained w...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21514
更新日期:2008-07-01 00:00:00
abstract::Manganese-enhanced MRI has previously been used for visualization of brain architecture and functional mapping of neural pathways. The present work investigated the potential of manganese-enhanced MRI for noninvasive imaging of salivary glands in living subjects. Marked shortening of T(1) was observed in salivary glan...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22452
更新日期:2010-09-01 00:00:00
abstract::A novel method based on selective detection of rapidly changing DeltaB(0) magnetic fields and suppression of slowly changing DeltaB(0) fields is presented. The ultimate goal of this work is to present a method that may allow detection of transient and subtle changes in B(0) in cortical tissue associated with electrica...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10159
更新日期:2002-06-01 00:00:00
abstract::In guinea pigs immunized with myelin basic protein (MBP) in complete Freund's adjuvant, experimental allergic encephalomyelitis (EAE) shows a characteristic clinical and pathological course. This study characterized the proton nuclear magnetic resonance (NMR) properties of the central nervous system prior to the onset...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910050203
更新日期:1987-08-01 00:00:00
abstract::In this study we utilized manganese-enhanced MRI (MEMRI) to evaluate the in vivo transneuronal efficiency of manganese ion (Mn(2+)) movement as a means to assess overall changes in neuronal function. We designated this extension the manganese transfer index (MTI) value. To evaluate the MTI value as an index of transne...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21648
更新日期:2008-07-01 00:00:00
abstract::Short image acquisition times and sensitivity to magnetic susceptibility favor the use of gradient echo imaging methods in functional MRI (fMRI). However, magnetic susceptibility effects attributed to air-tissue interfaces also lead to severe signal loss in images of the large inferior frontal and lateral temporal cor...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910370304
更新日期:1997-03-01 00:00:00
abstract::Functional magnetic resonance imaging (fMRI) was conducted to observe the effects of cocaine administration on the physiological fluctuations of fMRI signal in two brain regions. Seven long-term cocaine users with an average age of 32 years and 8 years of cocaine use history were recruited for the study. A T2*-weighte...
journal_title:Magnetic resonance in medicine
pub_type: 临床试验,杂志文章
doi:10.1002/(sici)1522-2594(200001)43:1<45::aid-mrm6>3
更新日期:2000-01-01 00:00:00
abstract::For time-resolved background-subtracted contrast-enhanced magnetic resonance angiography, the bright and sparse arterial signal allows unique identification of contrast bolus arrival in the arteries. This article presents an automatic filtering algorithm using such arterial characterization for selecting arterial phas...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10358
更新日期:2002-12-01 00:00:00
abstract::T1 is often ill-determined. This means that an Ernst angle excitation often cannot be precisely defined for the simple pulse and acquire experiment. Here, published 31P T1 values of metabolites in human muscle, liver, heart, and brain are archived, some new data on heart and brain added, and overall confidence interva...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910320120
更新日期:1994-07-01 00:00:00
abstract::Cervical spinal cord spectroscopy has the potential to add metabolic information to spinal cord MRI and improve the clinical evaluation and research investigation of spinal cord diseases, such as multiple sclerosis (MS) and intraspinal tumors. However, in vivo proton MR spectroscopy ((1)H-MRS) of the spinal cord is di...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21113
更新日期:2007-01-01 00:00:00
abstract:PURPOSE:MRI can produce quantitative liver fat fraction (FF) maps noninvasively, which can help to improve diagnoses of fatty liver diseases. However, most sequences acquire several two-dimensional (2D) slices during one or more breath-holds, which may be difficult for patients with limited breath-holding capacity. A w...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26028
更新日期:2016-11-01 00:00:00
abstract:PURPOSE:To obtain whole-brain high-resolution T2 maps in 2 minutes by combining simultaneous multislice excitation and low-power PINS (power independent of number of slices) refocusing pulses with undersampling and a model-based reconstruction. METHODS:A multi-echo spin-echo sequence was modified to acquire multiple s...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27890
更新日期:2019-12-01 00:00:00
abstract::The somatotopical organization of the human somatosensory cortex was analyzed with echo-planar imaging at 1.5 Tesla, utilizing deoxyhemoglobin as an endogenous contrast medium. Scrubbing stimulation at a frequency of 3 Hz was applied to one of three cutaneous areas: toes, fingertips, and tongue tip. Parasagittal echo-...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910330521
更新日期:1995-05-01 00:00:00
abstract:PURPOSE:To develop methods for characterizing materials used in screen-printed MRI coils and improve signal-to-noise ratio (SNR) with new lower-loss materials. METHODS:An experimental apparatus was created to characterize dielectric properties of plastic substrates used in receive coils. Coils were fabricated by scree...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26399
更新日期:2017-08-01 00:00:00
abstract::In an effort to develop MRI methods for the evaluation of tumor angiogenesis (new blood vessel formation), MRI-derived cerebral blood volume (CBV) information has been compared to histologic measures of microvessel density (MVD). Although MVD is a standard marker of angiogenesis, it is not a direct correlate of the vo...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1252
更新日期:2001-10-01 00:00:00
abstract::A technique using hyperpolarized (HP) 3He to image the small airways of the lung by using moderate flip angles and a short scanning period during early inspiration is demonstrated. Flip angles (alpha) ranging from 10-90 degrees were used in guinea pig experiments with scanning during the entire inspiration period. A s...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910390113
更新日期:1998-01-01 00:00:00
abstract::A current limitation of many myocardial tag acquisitions employing SPAMM encoding is the relatively rapid loss of tag contrast over the cardiac cycle. Acquisition schemes that apply line tags produce prolonged tag contrast compared with directly excited grid tags. However, a grid-tag series can be generated by combini...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910370519
更新日期:1997-05-01 00:00:00
abstract::Multislice, two-dimensional phosphorus 31 spectroscopic imaging (SI) of human brain was performed in 15 normal volunteers on a 3-Tesla magnetic resonance system. Images of free magnesium concentrations and pH as well as phosphoesters, inorganic phosphate, phosphocreatine, and adenosine triphosphate (ATP), were calcula...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199902)41:2<400::aid-mrm26
更新日期:1999-02-01 00:00:00
abstract::The signals of water in the different compartments of rat sciatic nerve are resolved in the (2)H double-quantum-filtered NMR spectrum, due to their different quadrupolar splittings and relaxation rates. This resolution allowed the independent measurement of the water diffusion coefficients in the different compartment...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199909)42:3<461::aid-mrm8>
更新日期:1999-09-01 00:00:00
abstract::The effects of macroscopic background field gradients upon 2D gradient echo images of inhaled (3)He in the human lung were investigated at 1.5 T. Effective compensation of in-slice signal loss in (3)He gradient echo images was then demonstrated using a multiple acquisition interleaved single gradient echo sequence. Th...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10549
更新日期:2003-08-01 00:00:00
abstract:PURPOSE:To investigate the effect of realistic microstructural geometry on the susceptibility-weighted MR signal in white matter (WM), with application to demyelination. METHODS:Previous work has modeled susceptibility-weighted signals under the assumption that axons are cylindrical. In this study, we explored the imp...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26689