Preserving the accuracy and resolution of the sodium bioscale from quantitative sodium MRI during intrasubject alignment across longitudinal studies.

Abstract:

:Emerging applications of sodium bioscales derived from quantitative sodium magnetic resonance imaging assess temporal changes in regional sodium concentration over intervals that vary from hours (monitoring tissue viability in stroke) to weeks (monitoring brain tumor treatment during radiation therapy) or even years (monitoring progression of neurodegenerative disease). Accurate interpretation of such quantitative data requires precise registration between magnetic resonance imaging sessions to avoid session-to-session changes in partial volume effects between normal tissue (∼38 mM sodium concentration), lesions (variable sodium concentration), and cerebrospinal fluid (∼144 mM sodium concentration). The existing Automated Image Registration algorithm is shown to be suitable for rapid, accurate, and precise determination of the transform that aligns sodium magnetic resonance images. Implementation of this transform during image reconstruction from the k-space data is shown to produce smaller errors than conventional image-domain interpolation. Experimental results at 9.4 T and 3.0 T demonstrating this registration approach to sodium data illustrate preservation of quantification accuracy during alignment of sodium magnetic resonance images acquired from the same subject during different imaging sessions.

journal_name

Magn Reson Med

authors

Atkinson IC,Lu A,Thulborn KR

doi

10.1002/mrm.23285

subject

Has Abstract

pub_date

2012-09-01 00:00:00

pages

751-61

issue

3

eissn

0740-3194

issn

1522-2594

journal_volume

68

pub_type

杂志文章
  • Development of an inductively coupled MR coil system for imaging and spectroscopic analysis of an implantable bioartificial construct at 11.1 T.

    abstract::Developing a method to noninvasively monitor tissue-engineered constructs is critical for the optimization of construct design and for assessing therapeutic efficacy. For this purpose, NMR is a powerful technique that can be used to obtain both images and spectroscopic data. But the inherent sensitivity of NMR limits ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22268

    authors: Volland NA,Mareci TH,Constantinidis I,Simpson NE

    更新日期:2010-04-01 00:00:00

  • Dynamic 31 P spectroscopic imaging of skeletal muscles combining flyback echo-planar spectroscopic imaging and compressed sensing.

    abstract:PURPOSE:Dynamic phosphorus MR spectroscopic imaging (31 P-MRSI) experiments require temporal resolution on the order of seconds to concurrently assess different muscle groups. A highly accelerated pulse sequence combining flyback echo-planar spectroscopic imaging (EPSI) and compressed sensing was developed and tested i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27682

    authors: Santos-Díaz A,Harasym D,Noseworthy MD

    更新日期:2019-06-01 00:00:00

  • Parallel reconstruction in accelerated multivoxel MR spectroscopy.

    abstract:PURPOSE:To develop the simultaneous acquisition of multiple voxels in localized MR spectroscopy (MRS) using sensitivity encoding, allowing reduced total scan time compared to conventional sequential single voxel (SV) acquisition methods. METHODS:Dual volume localization was used to simultaneously excite voxels in both...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25718

    authors: Boer VO,Klomp DW,Laterra J,Barker PB

    更新日期:2015-09-01 00:00:00

  • Fast maximum intensity projection algorithm using shear warp factorization and reduced resampling.

    abstract::Maximal intensity projection (MIP) is routinely used to view MRA and other volumetric angiographic data. The straightforward implementation of MIP is ray casting that traces a volumetric data set in a computationally expensive manner. This article reports a fast MIP algorithm using shear warp factorization and reduced...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10114

    authors: Fang L,Wang Y,Qiu B,Qian Y

    更新日期:2002-04-01 00:00:00

  • Magnetic resonance imaging of blood vessels at high fields: in vivo and in vitro measurements and image simulation.

    abstract::Unusually high image contrast in vivo magnetic resonance imaging of the brain becomes observable at high magnetic fields when the blood oxygenation level is lowered. The cause of the contrast has been attributed to a magnetic susceptibility effect induced by paramagnetic deoxyhemoglobin in red cells. When the cylinder...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910160103

    authors: Ogawa S,Lee TM

    更新日期:1990-10-01 00:00:00

  • Gradient characterization using a Fourier-transform technique.

    abstract::This paper describes a technique for characterizing the gradient subsystem of a magnetic resonance (MR) system. The technique uses a Fourier-transform analysis to directly measure the k-space trajectory produced by an arbitrary gradient waveform. In addition, the method can be easily extended to multiple dimensions an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390411

    authors: Alley MT,Glover GH,Pelc NJ

    更新日期:1998-04-01 00:00:00

  • Minimization of dead-periods in MRI pulse sequences for imaging oblique planes.

    abstract::With the advent of breath-hold MR cardiac imaging techniques, the minimization of TR and TE for oblique planes has become a critical issue. The slew rates and maximum currents of gradient amplifiers limit the minimum possible TR and TE by adding dead-periods to the pulse sequences. We propose a method of designing gra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320613

    authors: Atalar E,McVeigh ER

    更新日期:1994-12-01 00:00:00

  • Phase-labeled reference EPI for frequency-segmented inhomogeneity corrections (PREFICS).

    abstract:PURPOSE:To develop a method to correct for geometric distortions in non-Cartesian echo planar imaging using data acquired in a fast prescan. METHODS:Echo planar images were obtained using a non-Cartesian density weighted k-space trajectory. In contrast to linear Cartesian acquisition, distortions arising in non-Cartes...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24737

    authors: Zeller M,Müller A,Hahn D,Köstler H

    更新日期:2014-03-01 00:00:00

  • Bulk volume susceptibility difference between deoxyhemoglobin and oxyhemoglobin for HbA and HbS: A comparative study.

    abstract:PURPOSE:Sickle cell anemia is a blood disorder that alters the morphology and the oxygen affinity of the red blood cells. Cerebral oxygen extraction fraction measurements using quantitative BOLD contrast have been used for assessing inadequate oxygen delivery and the subsequent risk of ischemic stroke in sickle cell an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28668

    authors: Eldeniz C,Binkley MM,Fields M,Guilliams K,Ragan DK,Chen Y,Lee JM,Ford AL,An H

    更新日期:2021-01-21 00:00:00

  • Fast model-based T2 mapping using SAR-reduced simultaneous multislice excitation.

    abstract:PURPOSE:To obtain whole-brain high-resolution T2 maps in 2 minutes by combining simultaneous multislice excitation and low-power PINS (power independent of number of slices) refocusing pulses with undersampling and a model-based reconstruction. METHODS:A multi-echo spin-echo sequence was modified to acquire multiple s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27890

    authors: Hilbert T,Schulz J,Marques JP,Thiran JP,Krueger G,Norris DG,Kober T

    更新日期:2019-12-01 00:00:00

  • Three-dimensional whole body imaging of spin probes in mice by time-domain radiofrequency electron paramagnetic resonance.

    abstract::Imaging of stable paramagnetic spin probes in phantom objects and in vivo was evaluated using a RF time domain EPR spectrometer/imager operating at 300 MHz. Projections were collected using static magnetic field gradients and images were reconstructed using filtered back-projection techniques. Results from phantom obj...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200003)43:3<375::aid-mrm9>

    authors: Afeworki M,van Dam GM,Devasahayam N,Murugesan R,Cook J,Coffin D,Larsen JH,Mitchell JB,Subramanian S,Krishna MC

    更新日期:2000-03-01 00:00:00

  • Gradient field switching as a source for artifacts in MR imaging of metallic stents.

    abstract::Metallic implants, such as stents, have long been a concern in magnetic resonance imaging (MRI). In addition to safety issues, they are commonly associated with image artifacts. The mechanisms of radiofrequency- (RF) and susceptibility-induced artifacts have been thoroughly investigated. However, gradient-switching-in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20294

    authors: Shenhav A,Azhari H

    更新日期:2004-12-01 00:00:00

  • Human whole-blood (1)H2O longitudinal relaxation with normal and high-relaxivity contrast reagents: influence of trans-cell-membrane water exchange.

    abstract:PURPOSE:Accurate characterization of contrast reagent (CR) longitudinal relaxivity in whole blood is required to predict arterial signal intensity in contrast-enhanced MR angiography (CE-MRA). This study measured the longitudinal relaxation rate constants (R1 ) over a concentration range for non-protein-binding and pro...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25064

    authors: Wilson GJ,Woods M,Springer CS Jr,Bastawrous S,Bhargava P,Maki JH

    更新日期:2014-12-01 00:00:00

  • Quantification of perfusion in murine myocardium: A retrospectively triggered T1 -based ASL method using model-based reconstruction.

    abstract:PURPOSE:A method for the quantification of perfusion in murine myocardium is demonstrated. The method allows for the reconstruction of perfusion maps on arbitrary time points in the heart cycle while addressing problems that arise due to the irregular heart beat of mice. METHODS:A flow-sensitive alternating inversion ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25526

    authors: Gutjahr FT,Kampf T,Winter P,Meyer CB,Williams T,Jakob PM,Bauer WR,Ziener CH,Helluy X

    更新日期:2015-12-01 00:00:00

  • Impact of incidental magnetization transfer effects on inversion-recovery sequences that use a fast spin-echo readout.

    abstract::Multislice MR images obtained using a fast spin-echo (FSE) readout are strongly affected by magnetization transfer (MT) effects, which will cause a decrease in the observed longitudinal relaxation times for tissues with a large bound water component. This is pertinent for FSE-based inversion-recovery (IR) sequences, a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21338

    authors: Meara SJ,Barker GJ

    更新日期:2007-10-01 00:00:00

  • Sampling errors in projection reconstruction MRI.

    abstract::Certain kinds of artifacts have been reported when projection reconstruction (PR) techniques are used in magnetic resonance imaging (MRI). These will occur if the spacing between samples in k-space is too large. It has been suggested that PR requires finer k-space sampling than does two-dimensional Fourier reconstruct...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400317

    authors: Joseph PM

    更新日期:1998-09-01 00:00:00

  • A 13C NMR study of the application of [U-13C]succinate for metabolic investigations in rabbit renal proximal convoluted tubular cells.

    abstract::The fate of the 13C label arising from [U-13C]succinate in rabbit renal proximal convoluted tubular (PCT) cells, incubated with [U-13C]succinate, was investigated by 13C NMR spectroscopy of the perchloric acid extracts of the cell pellets. The 13C label of [U-13C]succinate was predominantly metabolized into glutamate,...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910140114

    authors: Jans AW,Willem R

    更新日期:1990-04-01 00:00:00

  • Spiral trajectory design: a flexible numerical algorithm and base analytical equations.

    abstract:PURPOSE:Spiral-based trajectories for magnetic resonance imaging can be advantageous, but are often cumbersome to design or create. This work presents a flexible numerical algorithm for designing trajectories based on explicit definition of radial undersampling, and also gives several analytical expressions for charact...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24675

    authors: Pipe JG,Zwart NR

    更新日期:2014-01-01 00:00:00

  • Repeatability and variability of myocardial perfusion imaging techniques in mice: Comparison of arterial spin labeling and first-pass contrast-enhanced MRI.

    abstract:PURPOSE:Preclinical imaging of myocardial blood flow (MBF) can elucidate molecular mechanisms underlying cardiovascular disease. We compared the repeatability and variability of two methods, first-pass MRI and arterial spin labeling (ASL), for imaging MBF in mice. METHODS:Quantitative perfusion MRI in mice was perform...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25769

    authors: Naresh NK,Chen X,Moran E,Tian Y,French BA,Epstein FH

    更新日期:2016-06-01 00:00:00

  • Polymetallic macromolecules are potential contrast agents of improved efficiency.

    abstract::The commercial synthetic homopolypeptide polyaspartate (average MW = 30,000, approximately 220 monomers) in solution quantitatively binds up to 40 mol Gd3+ ions per mole of polyaspartate. The water proton relaxivity of the solutions is far higher than that of clinically used or commonly investigated gadolinium(III) co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310109

    authors: Cavagna F,Luchinat C,Scozzafava A,Xia Z

    更新日期:1994-01-01 00:00:00

  • Statistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise.

    abstract::This work helps elucidate how background noise introduces statistical artifacts in the distribution of the sorted eigenvalues and eigenvectors in diffusion tensor MRI (DT-MRI) data. Although it was known that sorting eigenvalues (principal diffusivities) by magnitude introduces a bias in their sample mean within a hom...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200007)44:1<41::aid-mrm8>3.0.co;

    authors: Basser PJ,Pajevic S

    更新日期:2000-07-01 00:00:00

  • Single-shot half k-space high-resolution gradient-recalled EPI for fMRI at 3 Tesla.

    abstract::Half k-space gradient-recalled echo-planar imaging (GR-EPI) is discussed in detail. T2* decay during full k-space GR-EPI gives rise to unequal weighting of the lines of k-space, loss of signal intensity at the center of k-space, and a point-spread function that limits resolution. In addition, the long readout time for...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400517

    authors: Jesmanowicz A,Bandettini PA,Hyde JS

    更新日期:1998-11-01 00:00:00

  • Interleaved diffusion-weighted improved by adaptive partial-Fourier and multiband multiplexed sensitivity-encoding reconstruction.

    abstract:PURPOSE:We report a series of techniques to reliably eliminate artifacts in interleaved echo-planar imaging (EPI) based diffusion-weighted imaging (DWI). METHODS:First, we integrate the previously reported multiplexed sensitivity encoding (MUSE) algorithm with a new adaptive Homodyne partial-Fourier reconstruction alg...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25318

    authors: Chang HC,Guhaniyogi S,Chen NK

    更新日期:2015-05-01 00:00:00

  • Robust motion correction in CEST imaging exploiting low-rank approximation of the z-spectrum.

    abstract:PURPOSE:To introduce and evaluate an image registration technique for robust quantification of CEST acquisitions corrupted by motion. METHODS:The proposed iterative algorithm exploits a low-rank approximation of the z-spectrum (LRAZ), to gradually separate the contrast variation due to saturation at different off-reso...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27206

    authors: Wech T,Köstler H

    更新日期:2018-11-01 00:00:00

  • 16-channel bow tie antenna transceiver array for cardiac MR at 7.0 tesla.

    abstract:PURPOSE:To design, evaluate, and apply a bow tie antenna transceiver radiofrequency (RF) coil array tailored for cardiac MRI at 7.0 Tesla (T). METHODS:The radiofrequency (RF) coil array comprises 16 building blocks each containing a bow tie shaped λ/2-dipole antenna. Numerical simulations were used for transmission fi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25840

    authors: Oezerdem C,Winter L,Graessl A,Paul K,Els A,Weinberger O,Rieger J,Kuehne A,Dieringer M,Hezel F,Voit D,Frahm J,Niendorf T

    更新日期:2016-06-01 00:00:00

  • Whole-heart chemical shift encoded water-fat MRI.

    abstract:PURPOSE:To develop and evaluate a free-breathing chemical-shift-encoded (CSE) spoiled gradient-recalled echo (SPGR) technique for whole-heart water-fat imaging at 3 Tesla (T). METHODS:We developed a three-dimensional (3D) multi-echo SPGR pulse sequence with electrocardiographic gating and navigator echoes and evaluate...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24982

    authors: Taviani V,Hernando D,Francois CJ,Shimakawa A,Vigen KK,Nagle SK,Schiebler ML,Grist TM,Reeder SB

    更新日期:2014-09-01 00:00:00

  • Variable density incoherent spatiotemporal acquisition (VISTA) for highly accelerated cardiac MRI.

    abstract:PURPOSE:For the application of compressive sensing to parallel MRI, Poisson disk sampling (PDS) has been shown to generate superior results compared with random sampling methods. However, due to its limited flexibility to incorporate additional constraints, PDS is not readily extendible to dynamic applications. Here, w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25507

    authors: Ahmad R,Xue H,Giri S,Ding Y,Craft J,Simonetti OP

    更新日期:2015-11-01 00:00:00

  • Highly accelerated submillimeter resolution 3D GRASE with controlled T 2 blurring in T 2 -weighted functional MRI at 7 Tesla: A feasibility study.

    abstract:PURPOSE:To achieve highly accelerated submillimeter resolution T 2 -weighted functional MRI at 7T by developing a three-dimensional gradient and spin echo imaging (GRASE) with inner-volume sel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28589

    authors: Park S,Torrisi S,Townsend JD,Beckett A,Feinberg DA

    更新日期:2020-11-24 00:00:00

  • T2 measurement in articular cartilage: impact of the fitting method on accuracy and precision at low SNR.

    abstract::T2 relaxation time is a promising MRI parameter for the detection of cartilage degeneration in osteoarthritis. However, the accuracy and precision of the measured T2 may be substantially impaired by the low signal-to-noise ratio of images available from clinical examinations. The purpose of this work was to assess the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22178

    authors: Raya JG,Dietrich O,Horng A,Weber J,Reiser MF,Glaser C

    更新日期:2010-01-01 00:00:00

  • Magnetic susceptibility measurement of insoluble solids by NMR: magnetic susceptibility of bone.

    abstract::Measurements of the volume magnetic susceptibility of solids using the classical Gouy balance approach are hampered by variations in apparent density of the packed powder. In this paper a quantitative NMR measurement of the volume magnetic susceptibility of powdered solids is described and the volume susceptibility of...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370404

    authors: Hopkins JA,Wehrli FW

    更新日期:1997-04-01 00:00:00