Abstract:
:Certain kinds of artifacts have been reported when projection reconstruction (PR) techniques are used in magnetic resonance imaging (MRI). These will occur if the spacing between samples in k-space is too large. It has been suggested that PR requires finer k-space sampling than does two-dimensional Fourier reconstruction, and that the usual Nyquist criterion is inadequate. This paper examines this problem, with the conclusion that the Nyquist sampling criterion is adequate to avoid aliasing effects, provided that a band-limited interpolation is used in k-space. This procedure is motivated by analysis of the PR technique as it is commonly implemented in x-ray computed tomography. A related problem is shown to be the construction of a filter function in k-space that gives proper weight to the low spatial frequencies. It is shown that a simple ¿k¿ filter does not satisfy this requirement, and a procedure for deriving a suitable filter is described. The methods are tested in simulated PR profiles of circular disks of two different sizes. It is shown that the combination of the two new methods gives virtually perfect reconstruction for disks up to the size implied by the Nyquist limit.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Joseph PMdoi
10.1002/mrm.1910400317subject
Has Abstractpub_date
1998-09-01 00:00:00pages
460-6issue
3eissn
0740-3194issn
1522-2594journal_volume
40pub_type
杂志文章abstract::Cirrhosis is an important and growing public health problem, affecting millions of Americans and many more people internationally. A pathological hallmark of the progression to cirrhosis is the development of liver fibrosis, so that monitoring the appearance and progression of liver fibrosis can be used to guide thera...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22785
更新日期:2011-04-01 00:00:00
abstract::Lower extremity peripheral vein bypass grafts (LE-PVBG) imaged with high-resolution black blood three-dimensional (3D) inner-volume (IV) fast spin echo (FSE) MRI at 1.5 Tesla possess a two-layer appearance in T1W images while only the inner layer appears visible in the corresponding T2W images. This study quantifies t...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22037
更新日期:2009-09-01 00:00:00
abstract::In some dynamic applications of MRI, only a part of the field-of-view (FOV) actually undergoes dynamic changes. A class of methods, called reduced-FOV (rFOV) methods, convert the knowledge that some part of the FOV is static or not very dynamic into an increase in temporal resolution for the dynamic part, or into a re...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(200004)43:4<549::aid-mrm9>
更新日期:2000-04-01 00:00:00
abstract::In the recently proposed technique Sweep Imaging with Fourier Transform (SWIFT), frequency-modulated radiofrequency pulses are used in concert with simultaneous acquisition to facilitate MRI of samples with very short transverse relaxation time. In the present work, sweep MRI is reviewed from a reconstruction perspect...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22516
更新日期:2010-12-01 00:00:00
abstract::The orientation dependence of the free induction decay (FID) of 1H NMR water signal in ex vivo bovine digital flexor tendon at the native level of hydration is reported. Residual dipolar coupling due to the overall tissue anisotropy produces a 6:1 change in the signal intensity as an angle between the long axis of a s...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20540
更新日期:2005-08-01 00:00:00
abstract::The resolution and homogeneity limitations of echo-planar imaging (EPI) are overcome by zoom imaging of an easily shimmed localized volume. Use of the stimulated echo enables single-shot localization. In vivo 0.5-mm resolution EPI images of selected regions of a cat brain at 4.7 T are presented. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910140225
更新日期:1990-05-01 00:00:00
abstract::For time-resolved background-subtracted contrast-enhanced magnetic resonance angiography, the bright and sparse arterial signal allows unique identification of contrast bolus arrival in the arteries. This article presents an automatic filtering algorithm using such arterial characterization for selecting arterial phas...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10358
更新日期:2002-12-01 00:00:00
abstract:PURPOSE:To enable fast and flexible high-resolution four-dimensional (4D) MRI of periodic thoracic/abdominal motion for motion visualization or motion-corrected imaging. METHODS:We proposed a Cartesian three-dimensional k-space sampling scheme that acquires a random combination of k-space lines in the ky/kz plane. A p...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26406
更新日期:2017-08-01 00:00:00
abstract:PURPOSE:Quantitative mapping of the native T1 of the heart using the modified look-locker inversion recovery (MOLLI) technique provides high quality diagnostic information without requiring contrast agents. Previous work has considered the effects of T2 relaxation on MOLLI T1 measurements, finding that the T1 measured ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24867
更新日期:2013-09-01 00:00:00
abstract::Flow-independent angiography is a non-contrast-enhanced technique that can generate vessel contrast even with reduced blood flow in the lower extremities. A method is presented for producing these angiograms with magnetization-prepared balanced steady-state free precession (bSSFP). Because bSSFP yields bright fat sign...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21921
更新日期:2009-06-01 00:00:00
abstract:PURPOSE:Undiagnosed dehydration compromises health outcomes across many populations. Existing dehydration diagnostics require invasive bodily fluid sampling or are easily confounded by fluid and electrolyte intake, environment, and physical activity limiting widespread adoption. We present a portable MR sensor designed...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28004
更新日期:2020-04-01 00:00:00
abstract::High-field (>or=3 T) cardiac MRI is challenged by inhomogeneities of both the static magnetic field (B(0)) and the transmit radiofrequency field (B(1)+). The inhomogeneous B fields not only demand improved shimming methods but also impede the correct determination of the zero-order terms, i.e., the local resonance fre...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22234
更新日期:2010-02-01 00:00:00
abstract::In vivo, cardiac-gated, black-blood, and ex vivo magnetic resonance microscopy (MRM) images of the aortic root, and histopathology data were obtained from 12 transgenic and wild-type (WT) mice. MRM was performed using a black-blood imaging spin-echo sequence with upstream and downstream in-flow saturation pulses to ob...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10360
更新日期:2003-02-01 00:00:00
abstract::In this high resolution magnetic resonance spectroscopic study of experimental allergic encephalomyelitis (EAE) and Semliki Forest virus (SFV) infection of the Biozzi AB/H mouse, marked increases in the initially low levels of N-trimethyl compounds in the spinal cord were observed during probable demyelinating episode...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910320603
更新日期:1994-12-01 00:00:00
abstract::Multiple images acquired simultaneously from an array of surface coils can be combined to give a composite image with an improved signal-to-noise ratio (SNR) and a large field of view. The composite images' SNR can be optimized by taking advantage of noise correlations between coils and phase shifts induced by surface...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910160202
更新日期:1990-11-01 00:00:00
abstract::A proton NMR relaxation and pulsed field gradient self-diffusion study of water in fibrin gels, plasma, and blood clots has been performed with special emphasis on the effect of the sol-gel and shrinkage transitions. Deuteron NMR in fibrin gels was also studied to supplement the proton data. It is shown that a measure...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910140111
更新日期:1990-04-01 00:00:00
abstract::Consideration of spatially variable noise fields is becoming increasingly necessary in MRI given recent innovations in artifact identification and statistically driven image processing. Fast imaging methods enable study of difficult anatomical targets and improve image quality but also increase the spatial variability...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22013
更新日期:2009-08-01 00:00:00
abstract:PURPOSE:Quantitative susceptibility map (QSM) reconstruction is ill posed due to the zero values on the "magic angle cone" that make the maps prone to streaking artifacts. We propose projection onto convex sets (POCS) in the method of steepest descent (SD) for QSM reconstruction. METHODS:Two convex projections, an obj...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25155
更新日期:2015-02-01 00:00:00
abstract::A method is presented that employs the inherent spectral selectivity of the Steady-State Free Precession (SSFP) pulse sequence to provide a spectral band of suppression. At TE = TR/2, SSFP partitions the magnetization into two phase-opposed spectral components. Z-storing one of these components simultaneously further ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20633
更新日期:2005-10-01 00:00:00
abstract::Magnetization transfer experiments using an off-resonance irradiation technique were performed on bovine serum albumin solutions by varying the irradiation frequency and the concentration. A transition of the magnetization transfer spectrum from Lorentzian to Gaussian line shape was observed around the critical concen...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910320406
更新日期:1994-10-01 00:00:00
abstract:PURPOSE:Diabetic nephropathy (DN) is the leading cause of renal failure; however, current clinical tests are insufficient for assessing this disease. DN is associated with changes in renal metabolites, so we evaluated the utility of chemical exchange saturation transfer (CEST) imaging to detect changes characteristic o...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26045
更新日期:2016-11-01 00:00:00
abstract::Accumulation of lipids in atherosclerotic plaques causes progressive narrowing of the arterial lumen, often followed by thrombosis and ischemia. Currently several different methods, most requiring disruption of the plaque, are used to study the physical properties of lipids accumulated in plaques, and lipid compositio...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910390204
更新日期:1998-02-01 00:00:00
abstract:PURPOSE:To demonstrate the feasibility of a novel, ellipse fitting approach, named PLANET, for simultaneous estimation of relaxation times T1 and T2 from a single 3D phase-cycled balanced steady-state free precession (bSSFP) sequence. METHODS:A method is presented in which the elliptical signal model is used to descri...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26717
更新日期:2018-02-01 00:00:00
abstract::Image selected in vivo spectroscopy (ISIS) is a volume selection method often used for in vivo (31)P MRS, since it is suitable for measurements of substances with short T(2). However, ISIS can suffer from significant signal contributions caused by T(1) smearing from regions outside the VOI. A computer model was develo...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/1522-2594(200010)44:4<546::aid-mrm8>3.0.co
更新日期:2000-10-01 00:00:00
abstract::The previously reported concept for quantitative magnetization transfer (MT) imaging using balanced steady-state free precession (SSFP) is applied to nonbalanced SSFP sequences. This offers the possibility to derive quantitative MT parameters of targets with high-susceptibility variations such as the musculoskeletal s...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22331
更新日期:2010-07-01 00:00:00
abstract::Sequential albumin-Gd-DTPA and Gd-DTPA dynamic enhancement studies were performed in an animal tumor model for the comparison of regional vascularity and permeability parameters measured by these two different sizes of contrast agents. The early albumin-Gd-DTPA enhancement arises from the vascular compartment, and the...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910340318
更新日期:1995-09-01 00:00:00
abstract:PURPOSE:MRI-guided high intensity focused ultrasound (MR-HIFU) allows noninvasive heating of deep tissues. Specifically targeting visceral fat deposits with MR-HIFU could offer an effective therapy for reversing the development of obesity, diabetes, and metabolic syndrome. METHODS:Overweight rats received either MR-HI...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25883
更新日期:2016-07-01 00:00:00
abstract::Proton-observed carbon-edited (POCE) NMR spectroscopy is commonly used to measure 13C labeling with higher sensitivity compared to direct 13C NMR spectroscopy, at the expense of spectral resolution. For weakly coupled first-order spin systems, the multiplet signal at a specific proton chemical shift in POCE spectra di...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20764
更新日期:2006-02-01 00:00:00
abstract::A new k-space direct matrix inversion (DMI) method is proposed here to accelerate non-Cartesian SENSE reconstructions. In this method a global k-space matrix equation is established on basic MRI principles, and the inverse of the global encoding matrix is found from a set of local matrix equations by taking advantage ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20974
更新日期:2006-08-01 00:00:00
abstract:PURPOSE:To develop a one-step quantification approach that accounts for joint preprocessing and quantification of whole-range kinetics (early and late-phase washout) of dynamic contrast-enhanced (DCE) MRI of indeterminate adnexal masses. METHODS:Preoperative DCE-MRI of 43 (24 benign, 19 malignant) sonographically inde...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26743
更新日期:2018-02-01 00:00:00