Dehydration assessment via a portable, single sided magnetic resonance sensor.

Abstract:

PURPOSE:Undiagnosed dehydration compromises health outcomes across many populations. Existing dehydration diagnostics require invasive bodily fluid sampling or are easily confounded by fluid and electrolyte intake, environment, and physical activity limiting widespread adoption. We present a portable MR sensor designed to measure intramuscular fluid shifts to identify volume depletion. METHODS:Fluid loss is induced via a mouse model of thermal dehydration (37°C; 15-20% relative humidity). We demonstrate quantification of fluid loss induced by hyperosmotic dehydration with multicomponent T2 relaxometry using both a benchtop NMR system and MRI localized to skeletal muscle tissue. We then describe a miniaturized (~1000 cm3 ) portable (~4 kg) MR sensor (0.28 T) designed to identify dehydration-induced fluid loss. T2 relaxometry measurements were performed using a Carr-Purcell-Meiboom-Gill pulse sequence in ~4 min. RESULTS:T2 values from the portable MR sensor exhibited strong (R2 = 0.996) agreement with benchtop NMR spectrometer. Thermal dehydration induced weight loss of 4 to 11% over 5 to 10 h. Fluid loss induced by thermal dehydration was accurately identified via whole-animal NMR and skeletal muscle. The portable MR sensor accurately identified dehydration via multicomponent T2 relaxometry. CONCLUSION:Performing multicomponent T2 relaxometry localized to the skeletal muscle with a miniaturized MR sensor provides a noninvasive, physiologically relevant measure of dehydration induced fluid loss in a mouse model. This approach offers sensor portability, reduced system complexity, fully automated operation, and low cost compared with MRI. This approach may serve as a versatile and portable point of care technique for dehydration monitoring.

journal_name

Magn Reson Med

authors

Bashyam A,Frangieh CJ,Li M,Cima MJ

doi

10.1002/mrm.28004

subject

Has Abstract

pub_date

2020-04-01 00:00:00

pages

1390-1404

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

83

pub_type

杂志文章
  • Effects of acute normovolemic hemodilution on T2*-weighted images of rat brain.

    abstract::Acute normovolemic hemodilution (HD) was induced in anesthetized rats to assess the effect of changes in hematocrit (Hct) on signal intensity in T2*-weighted magnetic resonance (MR) images. Other relevant physiological parameters were maintained invariant. Two degrees of HD were induced: mild (Hct reduced from 42.6+/-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400611

    authors: Lin W,Paczynski RP,Celik A,Hsu CY,Powers WJ

    更新日期:1998-12-01 00:00:00

  • Single-Voxel 1 H MR spectroscopy of cerebral nicotinamide adenine dinucleotide (NAD+ ) in humans at 7T using a 32-channel volume coil.

    abstract:PURPOSE:Reliable monitoring of tissue nicotinamide adenine dinucleotide (NAD+ ) concentration may provide insights on its roles in normal and pathological aging. In the present study, we report a 1 H MRS pulse sequence for the in vivo, localized 1 H MRS detection of NAD+ from the human brain. METHODS:Studies were carr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27971

    authors: Bagga P,Hariharan H,Wilson NE,Beer JC,Shinohara RT,Elliott MA,Baur JA,Marincola FM,Witschey WR,Haris M,Detre JA,Reddy R

    更新日期:2020-03-01 00:00:00

  • Volumetric analysis of white matter, gray matter, and CSF using fractional volume analysis.

    abstract::Quantitative cerebral tissue volumes may be useful for an objective assessment of pathological changes in brain. Accurate determination of tissue volumes is complicated, however, by the partial volume averaging (PVA) effect. We have, therefore, developed a new pulse sequence that minimizes the PVA through the use of i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390614

    authors: Bedell BJ,Narayana PA

    更新日期:1998-06-01 00:00:00

  • Automatic in-line quantitative myocardial perfusion mapping: Processing algorithm and implementation.

    abstract:PURPOSE:Quantitative myocardial perfusion mapping has advantages over qualitative assessment, including the ability to detect global flow reduction. However, it is not clinically available and remains a research tool. Building upon the previously described imaging sequence, this study presents algorithm and implementat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27954

    authors: Xue H,Brown LAE,Nielles-Vallespin S,Plein S,Kellman P

    更新日期:2020-02-01 00:00:00

  • Simultaneous spin-echo refocusing.

    abstract::A new approach to spin-echo imaging is presented in which the 180 degrees RF pulse refocuses two or more spin-echoes at different positions in the readout period. When simultaneous echo refocusing (SER) is implemented using multiple 180 degrees pulses, an undesirable mixing of stimulated echoes and primary echoes from...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20587

    authors: Günther M,Feinberg DA

    更新日期:2005-09-01 00:00:00

  • Towards elimination of the dark-rim artifact in first-pass myocardial perfusion MRI: removing Gibbs ringing effects using optimized radial imaging.

    abstract:PURPOSE:Subendocardial dark-rim artifacts (DRAs) remain a major concern in first-pass perfusion (FPP) myocardial MRI and may lower the diagnostic accuracy for detection of ischemia. A major source of DRAs is the "Gibbs ringing" effect. We propose an optimized radial acquisition strategy aimed at eliminating ringing-ind...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24913

    authors: Sharif B,Dharmakumar R,LaBounty T,Arsanjani R,Shufelt C,Thomson L,Merz CN,Berman DS,Li D

    更新日期:2014-07-01 00:00:00

  • Fat-water separation based on Transition REgion Extraction (TREE).

    abstract:PURPOSE:To develop a method based on fat-water transition region extraction (TREE) for robust fat-water separation and quantification in challenging scenarios, including low signal-to-noise ratio (SNR), fast changing B0 field, and disjointed anatomies. THEORY AND METHODS:In TREE method, the phasor solutions of each pi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27710

    authors: Peng H,Zou C,Cheng C,Tie C,Qiao Y,Wan Q,Lv J,He Q,Liang D,Liu X,Liu W,Zheng H

    更新日期:2019-07-01 00:00:00

  • Detection of neural activity in functional MRI using canonical correlation analysis.

    abstract::A novel method for detecting neural activity in functional magnetic resonance imaging (fMRI) data is introduced. It is based on canonical correlation analysis (CCA), which is a multivariate extension of the univariate correlation analysis widely used in fMRI. To detect homogeneous regions of activity, the method combi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200102)45:2<323::aid-mrm1041>3.0

    authors: Friman O,Cedefamn J,Lundberg P,Borga M,Knutsson H

    更新日期:2001-02-01 00:00:00

  • Comparison of model-based arterial input functions for dynamic contrast-enhanced MRI in tumor bearing rats.

    abstract::When using tracer kinetic modeling to analyze dynamic contrast-enhanced MRI (DCE-MRI) it is necessary to identify an appropriate arterial input function (AIF). The measured AIF is often poorly sampled in both clinical and preclinical MR systems due to the initial rapid increase in contrast agent concentration and the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21959

    authors: McGrath DM,Bradley DP,Tessier JL,Lacey T,Taylor CJ,Parker GJ

    更新日期:2009-05-01 00:00:00

  • Rapid six-degree-of-freedom motion detection using prerotated baseline spherical navigator echoes.

    abstract::A new spherical navigator echo (SNAV) registration technique is presented. This technique starts by collecting a set of SNAV templates at a reference position. These templates are acquired by rotating the gradient system to result in rotation angles that uniformly cover a predefined range of rotation. The rotation ang...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22629

    authors: Liu J,Drangova M

    更新日期:2011-02-01 00:00:00

  • Transrectal probe for 1H MRI and 31P MR spectroscopy of the prostate gland.

    abstract::A transrectal probe for 1H imaging and 31P MR spectroscopy of the prostate gland is described. The probe is covered with plastic and consists of an insectional portion containing an rf coil and a handle containing a tuning and matching circuit. Using this transrectal probe, 1H MR images and the first 31P MR spectra of...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.1910110209

    authors: Narayan P,Vigneron DB,Jajodia P,Anderson CM,Hedgcock MW,Tanagho EA,James TL

    更新日期:1989-08-01 00:00:00

  • Utilization of an intra-oral diamagnetic passive shim in functional MRI of the inferior frontal cortex.

    abstract::Due to the presence of gross magnetic susceptibility artifacts, functional MRI (fMRI) has proved problematic in studies of the human inferior frontal cortex (IFC). There is a strong desire, therefore, to employ techniques that mitigate susceptibility artifacts in the IFC while preserving the imaging parameters of an f...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10626

    authors: Wilson JL,Jezzard P

    更新日期:2003-11-01 00:00:00

  • Human whole blood T2 relaxometry at 3 Tesla.

    abstract::A precise understanding of human blood spin-spin relaxation is of major importance for numerous applications, particularly functional magnetic resonance imaging (fMRI), which is increasingly performed at 3 Tesla. It is well known that T2 measured from partially deoxygenated blood depends on the Carr-Purcell Meiboom-Gi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21858

    authors: Chen JJ,Pike GB

    更新日期:2009-02-01 00:00:00

  • Perfusion-based functional magnetic resonance imaging with single-shot RARE and GRASE acquisitions.

    abstract::For perfusion-based functional magnetic resonance imaging, the previously introduced flow-sensitive alternating inversion recovery (FAIR) technique is combined with single-shot RARE (rapid acquisition with relaxation enhancement) and GRASE (gradient and spin echo) imaging sequences. The advantages of these sequences c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199901)41:1<132::aid-mrm18

    authors: Crelier GR,Hoge RD,Munger P,Pike GB

    更新日期:1999-01-01 00:00:00

  • Contrast-enhanced MRI of brown adipose tissue after pharmacological stimulation.

    abstract::A non-invasive method for studying the modifications induced in lipid depots by hormonal stimulation could extend knowledge of adipose tissues. We studied the effect of adrenergic stimulation on interscapular brown adipose tissue (IBAT) of rats using contrast-enhanced MRI. Controls and rats pre-treated with adrenaline...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20851

    authors: Sbarbati A,Cavallini I,Marzola P,Nicolato E,Osculati F

    更新日期:2006-04-01 00:00:00

  • Pharmacological MRI of the choroid and retina: blood flow and BOLD responses during nitroprusside infusion.

    abstract::Nitroprusside, a vasodilatory nitric oxide donor, is clinically used during vascular surgery and to lower blood pressure in acute hypertension. This article reports a novel application of blood flow (BF) and blood oxygenation level dependent (BOLD) MRI on an 11.7T scanner to image the rat chorioretinal BF and BOLD cha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24112

    authors: Shih YY,Li G,Muir ER,De La Garza BH,Kiel JW,Duong TQ

    更新日期:2012-10-01 00:00:00

  • Effect of lanthanide ions on dynamic nuclear polarization enhancement and liquid-state T1 relaxation.

    abstract::In the dynamic nuclear polarization process, microwave irradiation facilitates exchange of polarization from a radical's unpaired electron to nuclear spins at cryogenic temperatures, increasing polarization by >10,000. Doping samples with Gd(3+) ions further increases the achievable solid-state polarization. However, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24207

    authors: Gordon JW,Fain SB,Rowland IJ

    更新日期:2012-12-01 00:00:00

  • Spiral trajectory design: a flexible numerical algorithm and base analytical equations.

    abstract:PURPOSE:Spiral-based trajectories for magnetic resonance imaging can be advantageous, but are often cumbersome to design or create. This work presents a flexible numerical algorithm for designing trajectories based on explicit definition of radial undersampling, and also gives several analytical expressions for charact...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24675

    authors: Pipe JG,Zwart NR

    更新日期:2014-01-01 00:00:00

  • Automatic segmentation of the brain and intracranial cerebrospinal fluid in T1-weighted volume MRI scans of the head, and its application to serial cerebral and intracranial volumetry.

    abstract::A new fully automatic algorithm for the segmentation of the brain and total intracranial cerebrospinal fluid (CSF) from T(1)-weighted volume MRI scans of the head, called Exbrain v.2, is described. The algorithm was developed in the context of serial intracranial volumetry. A brain mask obtained using a previous versi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10436

    authors: Lemieux L,Hammers A,Mackinnon T,Liu RS

    更新日期:2003-05-01 00:00:00

  • Super-resolution for upper abdominal MRI: Acquisition and post-processing protocol optimization using brain MRI control data and expert reader validation.

    abstract:PURPOSE:Magnetic resonance (MR) cholangiopancreatography (MRCP) is an established specialist method for imaging the upper abdomen and biliary/pancreatic ducts. Due to limitations of either MR image contrast or low through-plane resolution, patients may require further evaluation with contrast-enhanced computed tomograp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27852

    authors: Ebner M,Patel PA,Atkinson D,Caselton L,Firmin L,Amin Z,Bainbridge A,De Coppi P,Taylor SA,Ourselin S,Chouhan MD,Vercauteren T

    更新日期:2019-11-01 00:00:00

  • MR microscopy of lung airways with hyperpolarized 3He.

    abstract::A technique using hyperpolarized (HP) 3He to image the small airways of the lung by using moderate flip angles and a short scanning period during early inspiration is demonstrated. Flip angles (alpha) ranging from 10-90 degrees were used in guinea pig experiments with scanning during the entire inspiration period. A s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390113

    authors: Chen XJ,Chawla MS,Hedlund LW,Möller HE,MacFall JR,Johnson GA

    更新日期:1998-01-01 00:00:00

  • T1 rho relaxation and its application to MR histology.

    abstract::The application of T1 rho an an alternative contrast parameter in high-field magnetic resonance histology (MRH) has been investigated. Spectroscopic measurements of T1 rho were performed on 5.75% agar and 1.0 mM MnCI2 phantoms at 9.4 T to validate the accuracy of the imaging measurements. Image studies were performed ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350520

    authors: Engelhardt RT,Johnson GA

    更新日期:1996-05-01 00:00:00

  • Design of spectral-spatial phase prewinding pulses and their use in small-tip fast recovery steady-state imaging.

    abstract:PURPOSE:Spectrally selective "prewinding" radiofrequency pulses can counteract B0 inhomogeneity in steady-state sequences, but can only prephase a limited range of off-resonance. We propose spectral-spatial small-tip angle prewinding pulses that increase the off-resonance bandwidth that can be successfully prephased by...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26794

    authors: Williams SN,Nielsen JF,Fessler JA,Noll DC

    更新日期:2018-03-01 00:00:00

  • Cellular imaging and texture analysis distinguish differences in cellular dynamics in mouse brain tumors.

    abstract:PURPOSE:The heterogeneous tumor cell population and dynamic microenvironment within a tumor lead to regional variations in cell proliferation, migration, and differentiation. In this work, MRI and optical projection tomography were used to examine and compare the redistribution of a cellular label in two mouse glioma m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24790

    authors: Gazdzinski LM,Nieman BJ

    更新日期:2014-04-01 00:00:00

  • Selective excitation of two-dimensional arbitrarily shaped voxels with parallel excitation in spectroscopy.

    abstract::Parallel excitation is being studied intensively for applications in MR imaging and in particular for selecting arbitrary shapes as regions of interest. In this work, parallel excitation was applied to arbitrarily shaped voxel selection in spectroscopy and investigated for different excitation k-space trajectories (ra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23018

    authors: Snyder J,Haas M,Hennig J,Zaitsev M

    更新日期:2012-02-01 00:00:00

  • A cylindrically symmetric magnetic shield for a large-bore 3.0 Tesla magnet.

    abstract::A 3.0 Tesla, 0.80-m bore magnet replaced our previous 1.9 Tesla, 0.76-m magnet. The 3.0 Tesla replacement magnet had a dipole moment of 1.7 with respect to that of the 1.9 Tesla magnet. The pre-existing cylindrically symmetric passive steel shielding was modified to confine the fringe fields of the replacement magnet ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290319

    authors: Ewing JR,Warner R,Helpern JA

    更新日期:1993-03-01 00:00:00

  • 3D coronary artery imaging with phase reordering for improved scan efficiency.

    abstract::Three-dimensional (3D) coronary imaging has the potential to overcome problems resulting from vessel tortuosity and to reduce partial volume effects. With these techniques, however, acquisition times are long and respiratory motion artifacts problematical. This work describes the development of a method that applies p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199903)41:3<555::aid-mrm19

    authors: Jhooti P,Keegan J,Gatehouse PD,Collins S,Rowe A,Taylor AM,Firmin DN

    更新日期:1999-03-01 00:00:00

  • First image from a combined positron emission tomography and field-cycled MRI system.

    abstract::Combining positron emission tomography and MRI modalities typically requires using either conventional MRI with a MR-compatible positron emission tomography system or a modified MR system with conventional positron emission tomography. A feature of field-cycled MRI is that all magnetic fields can be turned off rapidly...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22793

    authors: Bindseil GA,Gilbert KM,Scholl TJ,Handler WB,Chronik BA

    更新日期:2011-07-01 00:00:00

  • Oxygen-sensitive contrast in blood for steady-state free precession imaging.

    abstract::Steady-state free precession (SSFP) methods have gained widespread recognition for their ability to provide fast scans at high signal-to-noise ratio. This paper demonstrates that such methods are also capable of reflecting functional information, particularly blood oxygenation state. It is well known that SSFP signals...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20393

    authors: Dharmakumar R,Hong J,Brittain JH,Plewes DB,Wright GA

    更新日期:2005-03-01 00:00:00

  • pH mapping in living tissues: an application of in vivo 31P NMR chemical shift imaging.

    abstract::Chemical shifts were extracted from in vivo 3-dimensional 31P NMR CSI data and pH images were constructed. The images could spatially resolve tissue pH ranging from 5.8 to 7.2 (with uncertainty of 0.11-0.17 pH unit) in an ischemia-reperfusion model of diabetic rat calf muscles. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290214

    authors: Morikawa S,Inubushi T,Kito K,Kido C

    更新日期:1993-02-01 00:00:00