First image from a combined positron emission tomography and field-cycled MRI system.

Abstract:

:Combining positron emission tomography and MRI modalities typically requires using either conventional MRI with a MR-compatible positron emission tomography system or a modified MR system with conventional positron emission tomography. A feature of field-cycled MRI is that all magnetic fields can be turned off rapidly, enabling the use of conventional positron emission tomography detectors based on photomultiplier tubes. In this demonstration, two photomultiplier tube-based positron emission tomography detectors were integrated with a field-cycled MRI system (0.3 T/4 MHz) by placing them into a 9-cm axial gap. A positron emission tomography-MRI phantom consisting of a triangular arrangement of positron-emitting point sources embedded in an onion was imaged in a repeating interleaved sequence of ∼1 sec MRI then 1 sec positron emission tomography. The first multimodality images from the combined positron emission tomography and field-cycled MRI system show no additional artifacts due to interaction between the systems and demonstrate the potential of this approach to combining positron emission tomography and MRI.

journal_name

Magn Reson Med

authors

Bindseil GA,Gilbert KM,Scholl TJ,Handler WB,Chronik BA

doi

10.1002/mrm.22793

subject

Has Abstract

pub_date

2011-07-01 00:00:00

pages

301-5

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

66

pub_type

杂志文章
  • Lactate imaging with Hadamard-encoded slice-selective multiple quantum coherence chemical-shift imaging.

    abstract::The ability to generate in vivo maps of lactate may have significant diagnostic utility in staging and treatment planning of a wide variety of cancers. The double selective multiple quantum filter technique (SelMQC) has been shown to be effective for nonlocalized detection of lactate with little or no interference fro...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21659

    authors: Pickup S,Lee SC,Mancuso A,Glickson JD

    更新日期:2008-08-01 00:00:00

  • Lateral geniculate activations can be detected using intersubject averaging and fMRI.

    abstract::Applications of fMRI in functional brain imaging are mainly confined to single subject designs, prohibiting the assessment of subject or group by condition interactions (i.e., differential activations) or areas of conjoint activation. In this paper a framework for fMRI group designs, using statistical parametric mappi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380502

    authors: Büchel C,Turner R,Friston K

    更新日期:1997-11-01 00:00:00

  • Two-site reproducibility of cerebellar and brainstem neurochemical profiles with short-echo, single-voxel MRS at 3T.

    abstract:PURPOSE:To determine whether neurochemical concentrations obtained at two MRI sites using clinical 3T scanners can be pooled when a highly optimized, nonvendor short-echo, single-voxel proton MRS pulse sequence is used in conjunction with identical calibration and quantification procedures. METHODS:A modified semi-LAS...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25295

    authors: Deelchand DK,Adanyeguh IM,Emir UE,Nguyen TM,Valabregue R,Henry PG,Mochel F,Öz G

    更新日期:2015-05-01 00:00:00

  • Diffusion-weighted hyperpolarized 129Xe MRI in healthy volunteers and subjects with chronic obstructive pulmonary disease.

    abstract::Given its greater availability and lower cost, (129) Xe apparent diffusion coefficient (ADC) MRI offers an alternative to (3) He ADC MRI. To demonstrate the feasibility of hyperpolarized (129) Xe ADC MRI, we present results from healthy volunteers (HV), chronic obstructive pulmonary disease (COPD) subjects, and age-ma...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22697

    authors: Kaushik SS,Cleveland ZI,Cofer GP,Metz G,Beaver D,Nouls J,Kraft M,Auffermann W,Wolber J,McAdams HP,Driehuys B

    更新日期:2011-04-01 00:00:00

  • Enhancement of respiratory navigator-gated three-dimensional spoiled gradient-recalled echo sequence with variable flip angle scheme.

    abstract:PURPOSE:To develop and demonstrate the feasibility of a new technique for respiratory-gated, fat-suppressed, three-dimensional spoiled gradient-recalled echo (3D-SPGR) with navigator gating for more accurate and robust motion detection. METHODS:A navigator-gated 3D-SPGR technique was modified to include a wait period ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24902

    authors: Iwadate Y,Brau AC,Vasanawala SS,Kabasawa H

    更新日期:2014-07-01 00:00:00

  • Non-ECG-gated myocardial perfusion MRI using continuous magnetization-driven radial sampling.

    abstract:PURPOSE:Establishing a high-resolution non-ECG-gated first-pass perfusion (FPP) cardiac MRI technique may improve accessibility and diagnostic capability of FPP imaging. We propose a non-ECG-gated FPP imaging technique using continuous magnetization-driven golden-angle radial acquisition. The main purpose of this preli...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25074

    authors: Sharif B,Dharmakumar R,Arsanjani R,Thomson L,Bairey Merz CN,Berman DS,Li D

    更新日期:2014-12-01 00:00:00

  • Simultaneous image acquisition from the head (or body) coil and a surface coil.

    abstract::Any number of coils can in principle be used simultaneously and independently in magnetic resonance imaging if the mutual inductances are sufficiently small. Surface coils and head or body coils have equal sensitivity at some crossover depth of the order of 6 to 10 cm. Using a 7.5-cm-diameter surface coil that was int...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060212

    authors: Hyde JS,Froncisz W,Jesmanowicz A,Kneeland JB

    更新日期:1988-02-01 00:00:00

  • Radiofrequency energy deposition and radiofrequency power requirements in parallel transmission with increasing distance from the coil to the sample.

    abstract:PURPOSE:We investigated global specific absorption rate (SAR) and radiofrequency (RF) power requirements in parallel transmission as the distance between the transmit coils and the sample was increased. METHODS:We calculated ultimate intrinsic SAR (UISAR), which depends on object geometry and electrical properties but...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25646

    authors: Deniz CM,Vaidya MV,Sodickson DK,Lattanzi R

    更新日期:2016-01-01 00:00:00

  • A double echo ultra short echo time (UTE) acquisition for respiratory motion-suppressed high resolution imaging of the lung.

    abstract:PURPOSE:Magnetic resonance imaging is a promising alternative to computed tomography for lung imaging. However, organ motion and poor signal-to-noise ratio, arising from short T2*, impair image quality. To alleviate these issues, a new retrospective gating method was implemented and tested with an ultra-short echo time...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26891

    authors: Delacoste J,Chaptinel J,Beigelman-Aubry C,Piccini D,Sauty A,Stuber M

    更新日期:2018-04-01 00:00:00

  • Biodegradable, polymer encapsulated, metal oxide particles for MRI-based cell tracking.

    abstract::Metallic particles have shaped the use of magnetic resonance imaging (MRI) for molecular and cellular imaging. Although these particles have generally been developed for extracellular residence, either as blood pool contrast agents or targeted contrast agents, the coopted use of these particles for intracellular label...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.25263

    authors: Shapiro EM

    更新日期:2015-01-01 00:00:00

  • T2-prepared SSFP improves diagnostic confidence in edema imaging in acute myocardial infarction compared to turbo spin echo.

    abstract::T2-weighted MRI of edema in acute myocardial infarction (MI) provides a means of differentiating acute and chronic MI, and assessing the area at risk of infarction. Conventional T2-weighted imaging of edema uses a turbo spin-echo (TSE) readout with dark-blood preparation. Clinical applications of dark-blood TSE method...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21215

    authors: Kellman P,Aletras AH,Mancini C,McVeigh ER,Arai AE

    更新日期:2007-05-01 00:00:00

  • Determination of knee joint cartilage thickness using three-dimensional magnetic resonance chondro-crassometry (3D MR-CCM).

    abstract::The objective of this article was to analyze the accuracy and precision with which the quantitative distribution of articular cartilage can be determined in the knee joint using MRI. A three-dimensional (3D) technique that accounts for the out-of-plane deviation of the interface normal in strongly curved joint surface...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360213

    authors: Eckstein F,Gavazzeni A,Sittek H,Haubner M,Lösch A,Milz S,Englmeier KH,Schulte E,Putz R,Reiser M

    更新日期:1996-08-01 00:00:00

  • Improved reproducibility of right ventricular volumes and function estimation from cardiac magnetic resonance images using level-set models.

    abstract::This study aims to assess whether an alternative method, that is based on volumetric surface detection (VoSD) without tracing and is totally free of geometric assumptions, can improve the reproducibility of right ventricular (RV) volume quantification from cardiac magnetic resonance (CMR) images, in comparison with a ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21157

    authors: Catalano O,Corsi C,Antonaci S,Moro G,Mussida M,Frascaroli M,Baldi M,Caiani E,Lamberti C,Cobelli F

    更新日期:2007-03-01 00:00:00

  • Manganese-enhanced magnetic resonance imaging of mouse brain after systemic administration of MnCl2: dose-dependent and temporal evolution of T1 contrast.

    abstract::Manganese is a useful contrast agent for MRI of animals. Previously, it has been shown that systemic doses of MnCl(2) provide unique contrast in the rodent brain, enabling visualization of neuroarchitecture. The present work investigates the dose and temporal dependence of brain enhancement after i.v. administration o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20368

    authors: Lee JH,Silva AC,Merkle H,Koretsky AP

    更新日期:2005-03-01 00:00:00

  • In vivo multiple-mouse MRI at 7 Tesla.

    abstract::We developed a live high-field multiple-mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfitted with multiple transmit and ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20683

    authors: Bock NA,Nieman BJ,Bishop JB,Mark Henkelman R

    更新日期:2005-11-01 00:00:00

  • An evaluation of the effect of fasting on the exercise-induced changes in pH and Pi/PCr from skeletal muscle.

    abstract::The changes in the response of skeletal muscle to maximal dynamic exercise were investigated in going from a fasted state to a refed state by means of 31P NMR spectroscopy. It was found that in the fasted state, exercise-induced changes in Pi/PCr and in pH were both inhibited, in comparison with those in the refed sta...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030616

    authors: Lunt JA,Allen PS,Brauer M,Swinamer D,Treiber EO,Belcastro A,Eccles R,King EG

    更新日期:1986-12-01 00:00:00

  • Total brain N-acetylaspartate concentration in normal, age-grouped females: quantitation with non-echo proton NMR spectroscopy.

    abstract::The intra-individual and inter-individual variations of the global N-acetylaspartate (NAA) concentration were measured in a cohort of five 42+/-5 year-old normal females. The total NAA signal from the whole head was obtained with non-localized non-echo proton spectroscopy (1H-MRS) and converted into absolute mole amou...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.1910400506

    authors: Gonen O,Viswanathan AK,Catalaa I,Babb J,Udupa J,Grossman RI

    更新日期:1998-11-01 00:00:00

  • A multicontrast imaging method using steady-state free precession with alternating RF flip angles.

    abstract:PURPOSE:To obtain multicontrast images including fat-suppressed contrast image, a novel multicontrast imaging method using an SSFP sequence with alternating RF flip angles is proposed. METHODS:The proposed method uses the balanced SSFP sequence with 2 flip angles. In general, the conventional balanced SSFP sequence ha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27342

    authors: Kim J,Seo H,So S,Park H

    更新日期:2018-10-01 00:00:00

  • Shielded-coaxial-cable coils as receive and transceive array elements for 7T human MRI.

    abstract:PURPOSE:To investigate the use of shielded-coaxial-cable (SCC) coils as elements for multi-channel receive-only and transceive arrays for 7T human MRI and to compare their performance with equivalently sized conventional loop coils. METHODS:The SCC coil element consists of a coaxial loop with interrupted central condu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27964

    authors: Ruytenberg T,Webb A,Zivkovic I

    更新日期:2020-03-01 00:00:00

  • Free-breathing volumetric fat/water separation by combining radial sampling, compressed sensing, and parallel imaging.

    abstract:PURPOSE:Conventional fat/water separation techniques require that patients hold breath during abdominal acquisitions, which often fails and limits the achievable spatial resolution and anatomic coverage. This work presents a novel approach for free-breathing volumetric fat/water separation. METHODS:Multiecho data are ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26392

    authors: Benkert T,Feng L,Sodickson DK,Chandarana H,Block KT

    更新日期:2017-08-01 00:00:00

  • Driving mutually coupled gradient array coils in magnetic resonance imaging.

    abstract:PURPOSE:In contrast to conventional linear gradients, gradient coil arrays with arbitrary spatial dependency might experience strong mutual coupling. Although conventional gradient power amplifiers with feedback loop might compensate the effect of coupling, required voltages for the compensation are generally unknown a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27768

    authors: Ertan K,Taraghinia S,Atalar E

    更新日期:2019-09-01 00:00:00

  • Transient decrease in tumor oxygenation after intravenous administration of pyruvate.

    abstract::MRI using hyperpolarized (13) C-labeled pyruvate is a promising tool to biochemically profile tumors and monitor their response to therapy. This technique requires injection of pyruvate into tumor-bearing animals. Pyruvate is an endogenous entity but the influence of exogenously injected bolus doses of pyruvate on tum...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23065

    authors: Saito K,Matsumoto S,Devasahayam N,Subramanian S,Munasinghe JP,Morris HD,Lizak MJ,Ardenkjaer-Larsen JH,Mitchell JB,Krishna MC

    更新日期:2012-03-01 00:00:00

  • Three-dimensional diffusion tensor microimaging for anatomical characterization of the mouse brain.

    abstract::Diffusion tensor imaging is gaining increasing importance for anatomical imaging of the developing mouse brain. However, the application of diffusion tensor imaging to mouse brain imaging at microscopic levels is hindered by the limitation on achievable spatial resolution. In this study, fast diffusion tensor microima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22426

    authors: Aggarwal M,Mori S,Shimogori T,Blackshaw S,Zhang J

    更新日期:2010-07-01 00:00:00

  • MR-guided interstitial cryotherapy of the liver with a novel, nitrogen-cooled cryoprobe.

    abstract::The purpose of the study was to test a newly developed, MR-compatible, liquid nitrogen-cooled cryoprobe. The probe has an outer diameter of 3.5 mm and was specifically developed for percutaneous, MR-guided, interstitial cryotherapy. The probe was inserted percutaneously into the livers of 10 rabbits. The cryotherapy p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390304

    authors: Tacke J,Adam G,Speetzen R,Brucksch K,Bücker A,Heshel I,Prescher A,van Vaals JJ,Hunter DW,Rau G,Günther RW

    更新日期:1998-03-01 00:00:00

  • A comprehensive approach for correcting voxel-wise b-value errors in diffusion MRI.

    abstract:PURPOSE:In diffusion MRI, the actual b-value played out on the scanner may deviate from the nominal value due to magnetic field imperfections. A simple image-based correction method for this problem is presented. METHODS:The apparent diffusion constant (ADC) of a water phantom was measured voxel-wise along 64 diffusio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28078

    authors: Lee Y,Kettinger AO,Wilm BJ,Deichmann R,Weiskopf N,Lambert C,Pruessmann KP,Nagy Z

    更新日期:2020-06-01 00:00:00

  • Generalized matched filtering for time-resolved MR angiography of pulsatile flow.

    abstract::Generating flow-specific images (arteriograms, venograms) with optimal signal-to-noise ratios for time-resolved MR angiography is a conditional maximum problem, and its solutions are generalized matched filters. We have investigated six matched filters, corresponding to all possible combinations of three flow suppress...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300511

    authors: Wang Y,Weber DM,Korosec FR,Mistretta CA,Grist TM,Swan JS,Turski PA

    更新日期:1993-11-01 00:00:00

  • Analysis of multiple T2 proton relaxation processes in human head and imaging on the basis of selective and assigned T2 values.

    abstract::Two-dimensional T2-selective proton imaging of human head has been performed at 10 MHz employing Carr-Purcell-Gill-Meiboom pulse trains with echo separation of 6 and 12 msec. Using the information of 36 spin echoes and applying a recovery time of 2 sec the magnetization decay has been traced. The multi-exponential T2 ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910010406

    authors: Gersonde K,Felsberg L,Tolxdorff T,Ratzel D,Ströbel B

    更新日期:1984-12-01 00:00:00

  • Robust 4D flow denoising using divergence-free wavelet transform.

    abstract:PURPOSE:To investigate four-dimensional flow denoising using the divergence-free wavelet (DFW) transform and compare its performance with existing techniques. THEORY AND METHODS:DFW is a vector-wavelet that provides a sparse representation of flow in a generally divergence-free field and can be used to enforce "soft" ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25176

    authors: Ong F,Uecker M,Tariq U,Hsiao A,Alley MT,Vasanawala SS,Lustig M

    更新日期:2015-02-01 00:00:00

  • MRI monitoring of focused ultrasound sonications near metallic hardware.

    abstract:PURPOSE:To explore the temperature-induced signal change in two-dimensional multi-spectral imaging (2DMSI) for fast thermometry near metallic hardware to enable MR-guided focused ultrasound surgery (MRgFUS) in patients with implanted metallic hardware. METHOD:2DMSI was optimized for temperature sensitivity and applied...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27034

    authors: Weber H,Ghanouni P,Pascal-Tenorio A,Pauly KB,Hargreaves BA

    更新日期:2018-07-01 00:00:00

  • Rapid T1 mapping of mouse myocardium with saturation recovery Look-Locker method.

    abstract::Dynamic contrast-enhanced MRI using gadolinium or manganese provides unique characterization of myocardium and its pathology. In this study, an electrocardiography (ECG) triggered saturation recovery Look-Locker method was developed and validated for fast cardiac T(1) mapping in small animal models. By sampling the in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22544

    authors: Li W,Griswold M,Yu X

    更新日期:2010-11-01 00:00:00