Transient decrease in tumor oxygenation after intravenous administration of pyruvate.

Abstract:

:MRI using hyperpolarized (13) C-labeled pyruvate is a promising tool to biochemically profile tumors and monitor their response to therapy. This technique requires injection of pyruvate into tumor-bearing animals. Pyruvate is an endogenous entity but the influence of exogenously injected bolus doses of pyruvate on tumor microenvironment is not well understood. In this study, the effect of injecting a bolus of pyruvate on tumor oxygen status was investigated. EPR oxygen imaging revealed that the partial pressure of oxygen (pO(2)) in squamous cell carcinoma implanted in mice decreased significantly 30 min after [1-(13) C]pyruvate injection, but recovered to preinjection levels after 5 h. Dynamic contrast-enhanced-MRI studies showed that, at the dose of pyruvate used, no changes in tumor perfusion were noticed. Immunohistochemical analysis of hypoxic marker pimonidazole independently verified that the squamous cell carcinoma tumor transiently became more hypoxic by pyruvate injection. Efficacy of radiotherapy was suppressed when X-irradiation was delivered during the period of pyruvate-induced transient hypoxia. These results suggest importance of taking into account the transient decrease in tumor pO(2) after pyruvate injection in hyperpolarized (13) C MRI, because tumor oxygen status is an important factor in determining outcomes of therapies.

journal_name

Magn Reson Med

authors

Saito K,Matsumoto S,Devasahayam N,Subramanian S,Munasinghe JP,Morris HD,Lizak MJ,Ardenkjaer-Larsen JH,Mitchell JB,Krishna MC

doi

10.1002/mrm.23065

subject

Has Abstract

pub_date

2012-03-01 00:00:00

pages

801-7

issue

3

eissn

0740-3194

issn

1522-2594

journal_volume

67

pub_type

杂志文章
  • Localized imaging using stimulated echoes.

    abstract::Stimulated-echo localized spectroscopy was combined with phase- and frequency-encoding gradients to obtain "zoom" or magnified images of specific organs in situ. The technique requires neither surface coils nor an imaging coil arrangement that exclusively isolates the target organ. This technique can be readily applie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050412

    authors: Mills P,Chew W,Litt L,Moseley M

    更新日期:1987-10-01 00:00:00

  • A Bayesian approach for 4D flow imaging of aortic valve in a single breath-hold.

    abstract:PURPOSE:To develop and validate a data processing technique that allows phase-contrast MRI-based 4D flow imaging of the aortic valve in a single breath-hold. THEORY AND METHODS:To regularize the ill-posed inverse problem, we extend a recently proposed 2D phase-contrast MRI method to 4D flow imaging. Adopting an empiri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27386

    authors: Rich A,Potter LC,Jin N,Liu Y,Simonetti OP,Ahmad R

    更新日期:2019-02-01 00:00:00

  • The use of band-selectable digital filtering in magnetic resonance image enhancement.

    abstract::Manipulation of the data describing two-dimensional magnetic resonance (MR) images can be used to zoom an image, decrease image noise and artifacts by modeling, or emphasize object edges in the field of view. In this paper, a two-dimensional band-selectable digital filtering (2D-BSDF) technique is detailed. This can b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910090307

    authors: Mitchell DK,Nichols ST,Smith MR,Scott K

    更新日期:1989-03-01 00:00:00

  • Comparison of fitting methods and b-value sampling strategies for intravoxel incoherent motion in breast cancer.

    abstract:PURPOSE:To compare fitting methods and sampling strategies, including the implementation of an optimized b-value selection for improved estimation of intravoxel incoherent motion (IVIM) parameters in breast cancer. METHODS:Fourteen patients (age, 48.4 ± 14.27 years) with cancerous lesions underwent 3 Tesla breast MRI ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25484

    authors: Cho GY,Moy L,Zhang JL,Baete S,Lattanzi R,Moccaldi M,Babb JS,Kim S,Sodickson DK,Sigmund EE

    更新日期:2015-10-01 00:00:00

  • Perfusion-weighted imaging of interictal hypoperfusion in temporal lobe epilepsy using FAIR-HASTE: comparison with H(2)(15)O PET measurements.

    abstract::To detect perfusion abnormalities in areas of high magnetic susceptibility in the brain, an arterial spin-labeling MRI technique utilizing flow-sensitive alternating inversion recovery (FAIR) and half-Fourier single shot turbo spin-echo (HASTE) for spin preparation and image acquisition, respectively, was developed. I...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200103)45:3<431::aid-mrm1056>3.0

    authors: Liu HL,Kochunov P,Hou J,Pu Y,Mahankali S,Feng CM,Yee SH,Wan YL,Fox PT,Gao JH

    更新日期:2001-03-01 00:00:00

  • Piezoelectric-controlled tuning capacitor for surface coils.

    abstract::The design of a piezoelectric-controlled trimmer capacitor and its use as a tuning element of an MRI surface coil at 63.8 MHz are described. It is found that image quality does not depend strongly on match of the coil to the transmission line but that tuning can be a significant factor. The work is intended to lead ev...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910120106

    authors: Hyde JS,Rilling RJ,Jesmanowicz A,Kneeland JB

    更新日期:1989-10-01 00:00:00

  • Arterial spin labeling perfusion fMRI with very low task frequency.

    abstract::Functional magnetic resonance imaging (fMRI) has become the most widely used modality for visualizing regional brain activation in response to sensorimotor or cognitive tasks. While the majority of fMRI studies have used blood oxygenation level-dependent (BOLD) contrast as a marker for neural activation, baseline drif...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10437

    authors: Wang J,Aguirre GK,Kimberg DY,Roc AC,Li L,Detre JA

    更新日期:2003-05-01 00:00:00

  • More accurate estimation of diffusion tensor parameters using diffusion Kurtosis imaging.

    abstract::With diffusion tensor imaging, the diffusion of water molecules through brain structures is quantified by parameters, which are estimated assuming monoexponential diffusion-weighted signal attenuation. The estimated diffusion parameters, however, depend on the diffusion weighting strength, the b-value, which hampers t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22603

    authors: Veraart J,Poot DH,Van Hecke W,Blockx I,Van der Linden A,Verhoye M,Sijbers J

    更新日期:2011-01-01 00:00:00

  • Bayesian inference of hemodynamic changes in functional arterial spin labeling data.

    abstract::The study of brain function using MRI relies on acquisition techniques that are sensitive to different aspects of the hemodynamic response contiguous to areas of neuronal activity. For this purpose different contrasts such as arterial spin labeling (ASL) and blood oxygenation level dependent (BOLD) functional MRI tech...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21039

    authors: Woolrich MW,Chiarelli P,Gallichan D,Perthen J,Liu TT

    更新日期:2006-10-01 00:00:00

  • A double-tuned probe for metabolic NMR studies.

    abstract::A double-tuned single coil probe for high field metabolic NMR studies has been designed and tested. The resonant coil is a single-turn of copper foil wound on a quartz cylinder. It is fed by a short length of parallel strip line made of the same material; the feeder is also used as a tuning capacitance. Electrical par...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910230216

    authors: Najim E,Grivet JP

    更新日期:1992-02-01 00:00:00

  • Diffusion-weighted NMR spectroscopy allows probing of 13C labeling of glutamate inside distinct metabolic compartments in the brain.

    abstract::In the present work, diffusion-weighted (DW)-NMR spectroscopy of glutamate was performed during a (13)C-labeled glucose infusion in monkey brain (six experiments). It is shown that glutamate (13)C labeling occurs significantly faster at higher diffusion weightings-slightly for glutamate in position C4, and more marked...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21661

    authors: Valette J,Chaumeil M,Guillermier M,Bloch G,Hantraye P,Lebon V

    更新日期:2008-08-01 00:00:00

  • Real-time interactive MRI-guided cardiac surgery: aortic valve replacement using a direct apical approach.

    abstract::Minimally invasive cardiac surgery requires arresting and emptying of the heart, which compromises visualization of the surgical field. In this feasibility study a novel surgical procedure is demonstrated in which real-time MRI is used to guide the placement of a prosthetic aortic valve in the beating heart via direct...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21044

    authors: McVeigh ER,Guttman MA,Lederman RJ,Li M,Kocaturk O,Hunt T,Kozlov S,Horvath KA

    更新日期:2006-11-01 00:00:00

  • Mechanics and imaging of the macrocirculation.

    abstract::The mechanics of the macrocirculation are examined as a basis for imaging blood flow within the system. The macrocirculation is defined as that part of the circulation in which inertial forces are not negligible compared to viscous forces and as such in human subjects comprises the heart and large blood vessels. Becau...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910140204

    authors: Caro CG,Parker KH

    更新日期:1990-05-01 00:00:00

  • Improved large tip angle parallel transmission pulse design through a perturbation analysis of the Bloch equation.

    abstract::Parallel transmission has emerged as an efficient means for implementing multidimensional spatially selective radiofrequency excitation pulses. To date, most theoretical and experimental work on parallel transmission radiofrequency (RF) pulse design is based on the small-tip-angle approximation to the Bloch equation. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22827

    authors: Zheng H,Zhao T,Qian Y,Ibrahim TS,Boada FE

    更新日期:2011-09-01 00:00:00

  • On the use of double-quantum coherence from an AX3 system (protons in lactate) for spectral editing.

    abstract::The suppression of water signals in in vivo proton spectra by means of multiple-quantum filtering can be brought about in several ways. This communication exposes the shortcomings of using purely subtractive filtering techniques to observe signals from metabolites that contain proton couplings of the form AX3. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910110314

    authors: Nosel W,Trimble LA,Shen JF,Allen PS

    更新日期:1989-09-01 00:00:00

  • Dynamic field map estimation using a spiral-in/spiral-out acquisition.

    abstract::The long readout times of single-shot acquisitions and the high field strengths desired for functional MRI (fMRI) using blood oxygenation level-dependent (BOLD) contrast make functional scans sensitive to magnetic field inhomogeneity. If it is not corrected during image reconstruction, field inhomogeneity can cause ge...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20079

    authors: Sutton BP,Noll DC,Fessler JA

    更新日期:2004-06-01 00:00:00

  • Transition from Lorentzian to Gaussian line shape of magnetization transfer spectrum in bovine serum albumin solutions.

    abstract::Magnetization transfer experiments using an off-resonance irradiation technique were performed on bovine serum albumin solutions by varying the irradiation frequency and the concentration. A transition of the magnetization transfer spectrum from Lorentzian to Gaussian line shape was observed around the critical concen...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320406

    authors: Iino M

    更新日期:1994-10-01 00:00:00

  • Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition.

    abstract::Dynamic susceptibility contrast (DSC) MRI is now increasingly used for measuring perfusion in many different applications. The quantification of DSC data requires the measurement of the arterial input function (AIF) and the deconvolution of the tissue concentration time curve. One of the most accepted deconvolution me...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200009)44:3<466::aid-mrm18>3.0.c

    authors: Calamante F,Gadian DG,Connelly A

    更新日期:2000-09-01 00:00:00

  • Pulmonary edema induced by allergen challenge in the rat: noninvasive assessment by magnetic resonance imaging.

    abstract::The course of pulmonary edema formation after an intratracheal (i.t.) instillation of ovalbumin was followed noninvasively by magnetic resonance imaging (MRI) in actively sensitized Brown Norway (BN) rats. Changes in edema volume assessed by MRI mimicked the results from the analysis of the number and activation of in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200101)45:1<88::aid-mrm1013>3.0.

    authors: Beckmann N,Tigani B,Ekatodramis D,Borer R,Mazzoni L,Fozard JR

    更新日期:2001-01-01 00:00:00

  • Radioactive microsphere validation of a volume localized continuous saturation perfusion measurement.

    abstract::Detre et al. (Magn. Reson. Med. 23, 37-45 (1992)) and Zhang et al., (Magn. Reson. Med. 25, 362 (1992)) have recently demonstrated a technique for the measurement of regional cerebral blood flow (rCBF) based on the continuous saturation (or inversion) of the arterial blood supply to the brain in rats at 4.7 T. In the w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310208

    authors: Walsh EG,Minematsu K,Leppo J,Moore SC

    更新日期:1994-02-01 00:00:00

  • Robust motion correction in CEST imaging exploiting low-rank approximation of the z-spectrum.

    abstract:PURPOSE:To introduce and evaluate an image registration technique for robust quantification of CEST acquisitions corrupted by motion. METHODS:The proposed iterative algorithm exploits a low-rank approximation of the z-spectrum (LRAZ), to gradually separate the contrast variation due to saturation at different off-reso...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27206

    authors: Wech T,Köstler H

    更新日期:2018-11-01 00:00:00

  • Novel RF coil geometry for lower extremity imaging.

    abstract::A receive-only phased-array coil was designed to image the lower extremities. The array consists of four volume coils placed on two cylindrical formers. The coil array has the ability to image both legs simultaneously over a 40 cm longitudinal field of view (FOV). Experiments using phantoms show an increase in signal-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10712

    authors: Brown R,Mareyam A,Reid E,Wang Y

    更新日期:2004-03-01 00:00:00

  • Theoretical model of the single spin-echo relaxation time for spherical magnetic perturbers.

    abstract:PURPOSE:Magnetically labeled cells and tissue iron deposits provide qualitative means to detect and monitor cardiovascular and cerebrovascular diseases with magnetic resonance imaging. However, to quantitatively examine the extent of pathological micromorphological changes, detailed knowledge about microstructural para...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25196

    authors: Kurz FT,Kampf T,Heiland S,Bendszus M,Schlemmer HP,Ziener CH

    更新日期:2014-05-01 00:00:00

  • Rapid radiofrequency field mapping in vivo using single-shot STEAM MRI.

    abstract::Higher field strengths entail less homogeneous RF fields. This may influence quantitative MRI and MRS. A method for rapidly mapping the RF field in the human head with minimal distortion was developed on the basis of a single-shot stimulated echo acquisition mode (STEAM) sequence. The flip angle of the second RF pulse...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21676

    authors: Helms G,Finsterbusch J,Weiskopf N,Dechent P

    更新日期:2008-09-01 00:00:00

  • Capillarization of the sinusoids in liver fibrosis: noninvasive assessment with contrast-enhanced MRI in the rabbit.

    abstract::Sinusoidal capillarization induces microcirculatory changes in liver cirrhosis and fibrosis. The purpose of this study was to assess whether contrast-enhanced MRI can be used to demonstrate the effects of sinusoidal capillarization in liver fibrosis. Dynamic MRI after injection of a low-molecular-weight contrast agent...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10420

    authors: Van Beers BE,Materne R,Annet L,Hermoye L,Sempoux C,Peeters F,Smith AM,Jamart J,Horsmans Y

    更新日期:2003-04-01 00:00:00

  • In vivo measurement of volumetric strain in the human brain induced by arterial pulsation and harmonic waves.

    abstract::Motion-sensitive phase contrast magnetic resonance imaging and magnetic resonance elastography are applied for the measurement of volumetric strain and tissue compressibility in human brain. Volumetric strain calculated by the divergence operator using a biphasic effective-medium model is related to dilatation and com...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24499

    authors: Hirsch S,Klatt D,Freimann F,Scheel M,Braun J,Sack I

    更新日期:2013-09-01 00:00:00

  • A unique anisotropic R2 of collagen degeneration (ARCADE) mapping as an efficient alternative to composite relaxation metric (R2 -R1 ρ ) in human knee cartilage study.

    abstract:PURPOSE:Anisotropic transverse R2 (1/T2 ) relaxation of water proton is sensitive to cartilage degenerative changes. The purpose is to develop an efficient method to extract this relaxation metric in clinical studies. METHODS:Anisotropic R2 can be measured inefficiently by standard R2 mapping after removing an isotrop...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27621

    authors: Pang Y,Palmieri-Smith RM,Malyarenko DI,Swanson SD,Chenevert TL

    更新日期:2019-06-01 00:00:00

  • Evidence that both fast and slow water ADC components arise from intracellular space.

    abstract::Evaluation of water diffusion in the brain has revealed both fast- and slow-diffusing water populations. It has been suggested that these populations represent extra- and intracellular water, respectively. We have identified and characterized both populations in the intracellular space of the Xenopus oocyte. We have a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10301

    authors: Sehy JV,Ackerman JJ,Neil JJ

    更新日期:2002-11-01 00:00:00

  • Quantitative 1 H MRI and MRS of fatty acid composition.

    abstract::Adipose tissue as well as other depots of fat (triglycerides) are increasingly being recognized as active contributors to the human function and metabolism. In addition to the fat concentration, also the fatty acid chemical composition (FAC) of the triglyceride molecules may play an important part in diseases such as ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.28471

    authors: Peterson P,Trinh L,Månsson S

    更新日期:2021-01-01 00:00:00

  • Compartmental study of T(1) and T(2) in rat brain and trigeminal nerve in vivo.

    abstract::The integrated T(1)-T(2) characteristics of rat brain and trigeminal nerve water were studied in vivo using a rapid method for acquiring a series of images that depend on T(1) and T(2) relaxation times. Gray matter regions showed only one signal component in both the T(1) and T(2) domains. Trigeminal nerve, however, w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10060

    authors: Does MD,Gore JC

    更新日期:2002-02-01 00:00:00